THE SOUTl-lERN NEVADA REGIONAL HOUS1NGAUTHORI1Y • 340 N. 11. STREET. lAS VEGAS, NV 89101~3611
This Requestfor Quole numberis Q10106 for the following:
Rehabilitationand EnergyUpgrades@ 1632MazzantiWay, Henderson.NV
NeighborhoodStabilizationProgram(NSP)

QUOTE FORM

Scope of Work
1832 Mazzanti Way, Henderson, NV 89014

Work listed below shall meet the following standards:


1. Home Perfomnance Standards for Warm Climates (HPSFWC)
2. Clark County Optional Specifications for Water Saving Measures, October 2009 (WSM)
3. Clark County Housing Rehabilitation Specification Manual
4. Southern Nevada Regional Housing Authority specifications
5. Standard Materials/Appliance List included in this Work Scope
~ 11
6. Other requirements specifically listed in this Work Scope (incl. Installation Notes) ~
7. Local building codes and amendments for new or substantially altered work
8. Saturn Mechanical Systems Field Guide, Chapter 6 (2006)
';J/7 \ '/: ("" "3./-
".."'V'- .~ \:f
S
9. NSP Rental Project Standards Draft 5/25/2010 ~ I' U'"
10. Guidelines for Complying with BPI's Technical Standards for the Air Conditionin and Heat Pump vJ 0
t1 0
Professional . .' .
11. When the above documents contain multiple or confhcllng requirements, the most tnngent shall ap $\ Y

SCOPE OF WORK

Health Safe & Bulldln Code Measures $


Hard wire smoke detectors with battery backup in 3 Quantity = 3
bedrooms and near kitchen and test

Install CO detector(s) per manufacture(s specifications. Quantity = 1


Detectors to be linked to each other, hard wired with battery
backup.
Provide mechanical ventilation per AHSRAE 62.2-2003 Install Panasonic FV-04VE1 Whisper
based on all installed building shell sealing and energy Comfort Spot ERV Ceiling Insert
efficiency measures ) \ c1' 0 \ tJ tfJ Ventilator with Balance Ventilation and
Patent-Pending Capillary Core (set for
165'0
44 cfm continuous
Insulate exposed hot and cold water pipes with foam pipe Preformed foam (e.g. closed cell
insulation (R-4 min). Ensure 3" space between single wall polyethylene) conforming to ASTM
vent pipe. Use correct diameter of insulation sleeve so it fits C534. Tape seams, joints and ends of
tightly. Seal at wall penetrations. pipe sleeves. Use gun foam/caulk.

Install arc fault breakers for bedrooms (3)


Laundry: Replace existing assembly with metal washing e.g. Watts Water Technologies 2T-M2
machine shut off valve with hammer arrestor.
Add two seismic straps to DHW Heater, secured to studs. Straps - Upper 1/3 and Lower 1/3 or 4"
above controls
Add approved cover, gasket and seal outside electrical (Approx 3) e.g. Taymac MM410W (2-
outlets and switches. Re uires GFCI 3/4" Dee
Ensure electrical on outside of home to addition conforms Estimate based on improvements
with current code needed
Remove and replace non code shower entry at hall bath
Combustion Appliance Zone test out and repair (to be done Required when air sealing or duct
by contractor or subcontractor) sealing.

Electrical Panel
Legibly label all breakers in panel to clearly indicate area
served
THE SOUTHERN NEVADA REGIONAL HOUSING AUTHORITY. 340 N, 11''' STREET. LAs VEGAS, NV 89101.3611

This Requestfor Quotenumber,s 010106 for the following:


Rehabilitationand Energy Upgrades@ 1832MazzantiWay. Henderson.NV
NeighborhoodStabilizationProgram(NSP)
QUOTE FORM
Page 2 of6

Energy Efficiency Measures


J nfit
I ra t"Ion ,.
Reduce air leakage of the building shell to 1049 CFM50 See Insulation. yffl.J
Seal all outdoor light fIXtures to wall. Leave bottom of fixture
unsealed ~CL.
Weatherstrip doors /50
Windows Approx. 211 sq. ft.
Remove existing film and Install Solar Film (CP Film N1040
SR CDF\ 'or comnarable
HVAC & Insulation

Replace eXIsting HVAC System based on provided Amana AMV9 series 95 AFUE 2-stage
supporting load calc's & install programmable,
communicating thermostat
variable speed closed combustion gas
furnace. Amana ASX series 16 SEER 82>50
system, with Amana communicating
thermostat and matching evaporator
coil. Systems shall have minimum 5
vears narts warranty
Lower ductwork, bury in blown cellulose after sealing ducts (1) System
to < 6% ILeakaae to Outsidel ...1!JOO
Right Size Air Conditioning/Heating System: Manual J, D S
S l!.- f.. 5t!.& ,:prz-oF€r.r II .;.
Change supply grills with operable curve blades to improve
throw. Seal all boot to drvwall connections. ::rrJ CL..
Seal all attic ventilation. 'IW~
Remove existing batt and blown insulation and air seal
penetrations. Re-install fiberglass batts around FAU without
voids or gaps (compression is permitted). Add blown
cellulose to remainder of attic to increase to R-50
Knee Walls: Remove existing batt insulation and air seal
penetrations. Re-install fiberglass batts to R-19 without
voids or gaps and strap in place and install FSK material as
six sided assembly.
Install transfer grilles above each bedroom door (3) mimmum of 16" x 8"
IrlC.L.
Lighting
Replace all incandescent light bulbs with compact General. Eco-Smart 14w Soft White or
fluorescent bulbs (CFL) Use appropriate style for fixture. If equivalent Lamps to have min. 7 year
fixture will not support a CFL, replace fixture with warranty. Provide appropriate lamp
comparable CFL fixture format for fixture.
Replace all existing light fIxtures with Energy Star rated (3) Bedrooms - Portfolio 2-Light Rustic
fixtures. Brown Ceiling Flush mount, model
nO.LC0463RB
Install Energy Star rated bath light f,xtures in all baths Approx 3
Replace T-12 lamps and ballasts in kitchen with T-8
Replace entryway and rear patio light f,xtures with Energy
Star rated f,xlures
THE SOUTHERN NEVADA REGIONA.L HOUSING AUTHORITY • 340 N 11'~ STREET. LAS VEGAS, NV 89101.3611
This Request for Quote number is 010106 for the following
Rehabilitation and Energy Upgrades@ 1832 Mazzanti Way, Henderson, NV
Neighborhood Stabilization Program (NSP)
QUOrE FORM
Page 4 of 6

Install new Range GE 30 In. Freestanding Gas Range


Mooel # JGBS07DEMee
Install over the oven microwave GE Spacemaker@ Over-the-Range
Microwave Oven, Model #:
JVM1540DNWW
(exhaust vented to outside min. 120
cfm)
Exterior
Patch and touch up paint exterior walls and trim Low voe paints
Garage
Finish drywall and paint Garage walls and ceiling. Low voe paints.
Landscaping
Remove all dead plants and trim all plantings as needed. Bring grade up in rear to cover footing
General weed and clean of yard and. Front and rear.
Add 0/." rock to match existing to back yard.
Other
Install electrical plates as needed throughout
Install door hardware as needed. To match eXlstinQ.
Replace attic access hatch with new piece of drywall.
Texture to match eXlstlnQ and paint
Remove any mold/mildew and caulk all showers, baths,
countertops and vinyl areas (2) Bathrooms and kitchen.
Total Non-Enerav Efficlencv Measures
SNRHA Typical Work Items for NSP Properties (any items not
included above)
TesllnglMisc.
Perform blower door test per attached Testing Schedule and
provide written report
Perform duct leakage for all HVAC systems test after work is
completed and duct sealing specifications have been met and
provide written report
Test and calibrate all systems for proper operation per codes,
manufacturer's specifications and HPSWFC Ch. 5, provide written
report of items tested and results. Adjust equipment to comply with
operational standards.
/6,
Test combustion eqUIpment and adjust/repair as needed (per BPI
Performance Specificallons and HPSFWC Ch. 6), provide written
report of items tested and results
• Subcontracted Professionals: $

• Structural Engineer (as applicablelif not included in above work) $

• Mechanical Engineer (as applicable/if not included in above


work) $ /050
• Certified Energy Consultant (as applicable/if not included in
above work) $ A&oVf
Total Testing/Subcontracted Professional $