This document contains 6 questions related to the design of reinforced concrete structural elements. Question 1 asks to design the roof slab, wall, and base slab of a circular overhead water tank. Question 2 asks to design the circular ring beam of another overhead water tank. The remaining questions follow a similar pattern of providing design parameters and asking to size reinforced concrete elements and sketch reinforcement details.
This document contains 6 questions related to the design of reinforced concrete structural elements. Question 1 asks to design the roof slab, wall, and base slab of a circular overhead water tank. Question 2 asks to design the circular ring beam of another overhead water tank. The remaining questions follow a similar pattern of providing design parameters and asking to size reinforced concrete elements and sketch reinforcement details.
This document contains 6 questions related to the design of reinforced concrete structural elements. Question 1 asks to design the roof slab, wall, and base slab of a circular overhead water tank. Question 2 asks to design the circular ring beam of another overhead water tank. The remaining questions follow a similar pattern of providing design parameters and asking to size reinforced concrete elements and sketch reinforcement details.
Q. 1) The R.C.C. overhead circular water tank has an internal diameter 7.5m and height of wall is 4.0 m. The base slab of tank is supported over its periphery by a circular ring beam. Using M20 concrete and Fe415 steel, design the roof slab, wall and base slab. Sketch reinforcement details. Assume freeboard of 0.3m.
Q.2) The bottom circular ring beam of R.C.C. overhead water
tank has mean diameter of 7.0m and supported over six columns which are symmetrically provided. Design the ring beam for following data :- i) size of each column 450mm dia. ii) U.D.L. on circular beam 250 KN/m (inclusive S.W.) iii) width of beam 400mm iv) The standard coefficients are for support B.M. = 0.089, for mid span B.M. = 0.045 v) For maximum twisting moment =0.009 at 12.75 0 Support. vi) Use M20 and Fe 415 steel.
Q.3) The R.C.C. overhead circular water tank has an internal
diameter 8.0m and height of wall is 4.5 m. The base slab of tank is supported over its periphery by a circular ring beam. Using M20 concrete and Fe415 steel, design the roof slab, wall and base slab. Sketch reinforcement details. Assume freeboard of 0.3m.
Q.4) The bottom circular ring beam of R.C.c. overhead water
tank has mean diameter of 7.5m and supported over six columns which are symmetrically provided. Design the ring beam for following data :- i) size of each column 450mm dia. ii) U.D.L. on circular beam 275 KN/m (inclusive S.W.) iii) width of beam 425mm iv) The standard coefficients are for support B.M. = 0.089, for mid span B.M. = 0.045 v) For maximum twisting moment =0.009 at 12.75 0Support. vi) Use M20 and Fe 415 steel. vii)
Q.5) The R.C.C. overhead circular water tank has an internal
diameter 8.0m and height of wall is 4.5 m. The base slab of tank is supported over its periphery by a circular ring beam. Using M20 concrete and Fe415 steel, design the roof slab, wall and base slab. Sketch reinforcement details. Assume freeboard of 0.3m.
Q.6) The bottom circular ring beam of R.C.c. overhead water
tank has mean diameter of 8.0m and supported over six columns which are symmetrically provided. Design the ring beam for following data :- i) size of each column 450mm dia. ii) U.D.L. on circular beam 250 KN/m (inclusive S.W.) iii) width of beam 400mm iv) The standard coefficients are for support B.M. = 0.089, for mid span B.M. = 0.045 For maximum twisting moment =0.009 at 12.75 0Support. v) Use M20 and Fe 415 steel.
Unit - 2 :-R.C.C Deck Slab Bridge.
Q. 1) State classification of IRC loading for highway bridge with their salient features.
Q. 2) Design R.C.C. bridge deck slab to suit following data :-
i) Carriageway Two lane 7.5mm wide ii) Clear span 5.0m iii) Footpath 1200mm wide on either side iv) Width of bearing 450mm v) Wearing coat 80mm vi) Loading IRC class AA tracked vehicle vii) Use M20 concrete and Fe415 steel ix) Impactor for 5m span is 25% and linearly decreasing to 10% for 9m span. Draw reinforcement details. Q. 3) Design R.C.C. bridge deck slab to suit following data :- i) Carriageway Two lane 7.5mm wide ii) Clear span 5.0m iii) Footpath 1200mm wide on either side iv) Width of bearing 450mm v) Wearing coat 80mm vi) Loading IRC class AA Wheel Load. vii) Use M20 concrete and Fe415 steel ix) Impactor for 5m span is 25% and linearly decreasing to 10% for 9m span. Draw reinforcement details.
Q. 4) Design R.C.C. bridge deck slab to suit following data :-
i) Carriageway Two lane 7.5mm wide ii) Clear span 5.0m iii) Footpath 1200mm wide on either side iv) Width of bearing 450mm v) Wearing coat 80mm vi) Loading IRC class A -loading vii) Use M20 concrete and Fe415 steel ix) Impactor for 5m span is 25% and linearly decreasing to 10% for 9m span. Draw reinforcement details.
Q. 5) Design R.C.C. bridge deck slab to suit following data :-
i) Carriageway Two lane 7.5mm wide ii) Clear span 5.0m iii) Footpath 1200mm wide on either side iv) Width of bearing 450mm v) Wearing coat 80mm vi) Loading IRC class B Loading vii) Use M20 concrete and Fe415 steel ix) Impactor for 5m span is 25% and linearly decreasing to 10% for 9m span. Draw reinforcement details.
Unit - 3 :-Portal Frames.
Q. 1) A large hall is to be provided with rectangular frames for following data i) Centre to centre of frames 3.5m ii) Centre to centre of column 3.5m iii) Height of frame from top of footing to centre line of beam 6.0m iv) size of beam 250mm x 500mm v) Ibeam = 2.0 Icolumn vi) Overall thickness of slab = 125mm vi) Live load on slab = 2.5 KN/m2 vii) M20 concrete and Fe415 steel is used Analyze interior frame, draw B.M.D. and design the beam. Sketch reinforcement details of beam
Q. 2) A large hall is to be provided with rectangular frames for
following data i) Centre to centre of frames 4.00 m ii) Centre to centre of column 3.5m iii) Height of frame from top of footing to centre line of beam 6.0m iv) size of beam 250mm x 550mm v) Ibeam = 2.0 Icolumn vi) Overall thickness of slab = 125mm viii) Live load on slab = 2.5 KN/m2 ix) M20 concrete and Fe415 steel is used Analyze interior frame, draw B.M.D. and design the beam. Sketch reinforcement details of beam
Q. 3) A large hall is to be provided with rectangular frames for
following data i) Centre to centre of frames 3.5m ii) Centre to centre of column 4.0m iii) Height of frame from top of footing to centre line of beam 6.0m iv) size of beam 300mm x 500mm v) Ibeam = 2.0 Icolumn vi) Overall thickness of slab = 125mm x) Live load on slab = 2.5 KN/m2 xi) M20 concrete and Fe415 steel is used Analyze interior frame, draw B.M.D. and design the beam. Sketch reinforcement details of beam
Q. 4) A large hall is to be provided with rectangular frames for
following data i) Centre to centre of frames 3.0m ii) Centre to centre of column 3.0m iii) Height of frame from top of footing to centre line of beam 6.0m iv) size of beam 250mm x 400mm v) Ibeam = 2.0 Icolumn vi) Overall thickness of slab = 125mm xii) Live load on slab = 2.5 KN/m2 xiii) M20 concrete and Fe415 steel is used Analyze interior frame, draw B.M.D. and design the beam. Sketch reinforcement details of beam
Q. 5) A large hall is to be provided with rectangular frames for
following data i) Centre to centre of frames 3.25m ii) Centre to centre of frames 3.25m iii) Height of frame from top of footing to centre line of beam 6.0m iv) size of beam 250mm x 450mm v) Ibeam = 2.0 Icolumn vi) Overall thickness of slab = 125mm xiv) Live load on slab = 2.5 KN/m2 xv) M20 concrete and Fe415 steel is used Analyze interior frame, draw B.M.D. and design the beam. Sketch reinforcement details of beam
Unit - 4 :-Cylindrical Shell.
Q.1) Design an interior panel of a cylindrical shell roof covering plan area of 12m x 30m (effective) by beam method. The semi-central angle is 380 . Assume suitable size of edge beam and thickness. Live load on shell is 1KN/m2. Use M20 concrete and Fe415 steel. Draw reinforcement details. Q.2) Design a suitable footing for following data :- a) Axial load through column due to D.L. 700 KN due to D.L. 300 KN b) The B.M. (Uniaxial on footing due to D.L. 45 KN due to D.L. 25 KN c) The size of column is 500mm x 300mm d) The safe bearing capacity of soil is 275KN/m2 e) Use M20 Concrete and Fe415 steel sketch reinforcement details. Q.3) Design an interior panel of a cylindrical shell roof covering plan area of 10m x 30m (effective) by beam method. The semi-central angle is 360 . Assume suitable size of edge beam and thickness. Live load on shell is 1KN/m2. Use M20 concrete and Fe415 steel. Draw reinforcement details. Q.4) Design a suitable footing for following data :- a) Axial load through column due to D.L. 750 KN due to D.L. 350 KN b) The B.M. (Uniaxial on footing due to D.L. 50 KN due to D.L. 30 KN c) The size of column is 500mm x 300mm d) The safe bearing capacity of soil is 275KN/m2 e) Use M20 Concrete and Fe415 steel sketch reinforcement details. Q.5) Design an interior panel of a cylindrical shell roof covering plan area of 12m x 32m (effective) by beam method. The semi-central angle is 400 . Assume suitable size of edge beam and thickness. Live load on shell is 1KN/m2. Use M20 concrete and Fe415 steel. Draw reinforcement details.
Q.6) Design an interior panel of a cylindrical shell roof
covering plan area of 10m x 25m (effective) by beam method. The semi-central angle is 300 . Assume suitable size of edge beam and thickness. Live load on shell is 1KN/m2. Use M20 concrete and Fe415 steel. Draw reinforcement details.
Q.7) Design a suitable footing for following data :-
a) Axial load through column due to D.L. 800 KN due to D.L. 400 KN b) The B.M. (Uniaxial on footing due to D.L. 60 KN due to D.L. 40 KN c) The size of column is 500mm x 300mm d) The safe bearing capacity of soil is 275KN/m2 e) Use M20 Concrete and Fe415 steel sketch reinforcement details
Q.8) Design an interior panel of a cylindrical shell roof
covering plan area of 10m x 25m (effective) by beam method. The semi-central angle is 380 . Assume suitable size of edge beam and thickness. Live load on shell is 1KN/m2. Use M20 concrete and Fe415 steel. Draw reinforcement details. Q.9) Design a suitable footing for following data :- a) Axial load through column due to D.L. 750 KN due to D.L. 350 KN b) The B.M. (Uniaxial on footing due to D.L. 45 KN due to D.L. 25 KN c) The size of column is 500mm x 300mm d) The safe bearing capacity of soil is 275KN/m2 e) Use M20 Concrete and Fe415 steel sketch reinforcement details
A Short Guide to the Types and Details of Constructing a Suspension Bridge - Including Various Arrangements of Suspension Spans, Methods of Vertical Stiffening and Wire Cables Versus Eyebar Chains