Fast Response,
High-Performance,
Immersible Thermal
Gas Mass Flow Meter
Features
www.sierrainstruments.com
Dimensional Specifications Tables
1/2-inch
9.0
NPT
L09
(228.6)
0.55
0.55 (14.0)
(14.0) L
13.0
L L13
(330.2)
NEMA 4X with Junction Box Side View (EN4) NEMA 4X with Junction BoxFront View (EN4)
0.70 3.93
2.38 (99.8)
(60.5) (17.8)
.90 .05
(22.9) (1.3)
3.93
2.46 (99.8)
(62.5)
CL 1/2-inch 0.55
NPT (14.0)
L
0.275 0.375
(7.0) (9.5)
Per Customer
Cable Length Requirement,
100 Feet Maximum
All dimensions are inches. Millimeters are in parentheses . Certified drawings are available on request.
Performance Specifications Operating Specifications (continued)
Accuracy of Point Velocity Alarms
+/- 1% of full scale Hard contact user-adjustable high and low
Repeatability Dead band adjustable with Smart Interface software
+/- 0.2% of full scale Relay ratings Maximum 42 VAC or 42 VDC, 140 mA
Digital Communication
Modbus RTU
Viton, Neoprene, Kalrez, and Teflon are registered trademarks of Dupont. Windows and Excel are registered trademark of Microsoft.
ORDERING INFORMATION
Features Options
620S - - - - - - - - -
1 2 3 4 5 6 1 2 3
Instructions: To order a 620S please fill in each number block by selecting the codes from the corresponding features
below and following pages.
Parent Number
620S FastFlo Insertion Mass Flow Meter. 18-30 VDC input power with a 3/8-inch in diameter probe. Includes "Smart Electronics" with PC configuration
software, calibrated temperatures up to 176F (80C) and pressures up to 150 psig (10.34 barg). 200 msec response. CE approved. 4-20 mA, 0-10 VDC or
0-5 VDC linear output
NOTE: ALL slpm flow ranges also available in nlpm. * Flow bodies are sized for nitrogen flow rates. Other gases must be converted to equivalent nitrogen flow. Use K-factor and size accordingly.
NR No readout
DD Digital display. 2 x 12 digit, backlit, LCD display indicates
flow rate and totalized mass in engineering units. Simplifies Feature 6: Gas
configuration settings and provides system status information 0 Air
1 Argon
Option 1: Digital Communications 2 Carbon dioxide
PULSE Totalizer pulse output (1 Hz max) 6 Helium
MB Modbus communications protocol
10 Nitrogen
99 Other--consult factory
Serra Instruments, North America 5 Harris Court, Building L Monterey, California (800) 866-0200 (831) 373-0200 Fax (831) 373-4402 www.sierrainstruments.com
Serra Instruments, Europe Bijlmansweid 2 1934RE Egmond aan den Hoef The Netherlands +31 72 5071400 Fax: +31 72 5071401
Serra Instruments, Asia Second Floor Building 5 Senpu Industrial Park 25 Hangdu Road Hangtou Town Pu Dong New District Shanghai, P.R. China 201316 +8621 5879 8521/22 Fax: +8621 5879 8586
620S B I 8/15