Вы находитесь на странице: 1из 49

SPG35

Silos for storing powders

1
SF.SPG35.T.A2.0911.EN

Technical Catalogue
SF.SPG35.T.A2.0911.EN

INDEX

DESCRIPTION AND FUNCTION..........................................................................................................3


DESIGN AND EXECUTION STANDARDS...........................................................................................4

STANDARD SILOS: Materials and finishes.....................................................................................5


OPTIONS: Materials and finishes....................................................................................................6
ACCESSORIES: Materials and finishes..........................................................................................7

MODULAR CODE.................................................................................................................................8

STANDARD SUPPLY............................................................................................................................9
RANGE..........................................................................................................................................10
SPG35.035....................................................................................................................................11
SPG35.050...................................................................................................................................12
SPG35.065...................................................................................................................................13
SPG35.080...................................................................................................................................14
SPG35.095.....................................................................................................................................15
SPG35.110.....................................................................................................................................16
SPG35.125....................................................................................................................................17
SEISMIC ZONE.............................................................................................................................18

OPTIONS............................................................................................................................................19
VERSION......................................................................................................................................19
LEGS.............................................................................................................................................20
PROVISION FOR FILTER.............................................................................................................22
PROVISION FOR VCP..................................................................................................................24
PROVISION FOR IPX...................................................................................................................25
FILLING PIPE................................................................................................................................26
SLEEVES ON CAP........................................................................................................................27
BOTTOM CONE............................................................................................................................28
FLUIDIZATION..............................................................................................................................30
FLANGE AT OUTLET....................................................................................................................31
LADDER........................................................................................................................................32
RAILING........................................................................................................................................34
CONNECTING GANGWAY...........................................................................................................37
SURFACE TREATMENT AND SHADES......................................................................................38

ACCESSORIES..................................................................................................................................39
LEGS EXTENSION.......................................................................................................................39
FILLING PIPE AND EXHAUST PIPE EXTENSION .....................................................................40
LADDER AND CABLE GLAND TUBE EXTENSION.....................................................................41
SUPPORTING FRAME.................................................................................................................42
ADAPTERS FOR FILTER.............................................................................................................45
COMMERCIAL COMPONENTS PRESENT IN SILOS.................................................................46
RECOMMENDED ACCESSORIES TO BE MOUNTED ON SILO................................................47

2 1-Technical Catalogue
1-Technical Catalogue

DESCRIPTION AND FUNCTION

The silo is a tank for the collection and storage of bulk solid materials in powder or granular form, with varying
particle size (cement, sand, limestone, lime, fly ash, etc.).
It is mainly used in the building sector.
Filling is done by means of a pneumatic pumping system, by means of a tube provided for the purpose in the
silo.
The pressure generated inside during pneumatic conveying passses through a filter placed on the silo roof or
on the ground.
The silos are located mainly outdoors and are fixed to a concrete platform.
The customer is responsible for sizing and construction of the afore-mentioned structure.
NOTE: If material other than cement, or material with special fluidity or granulometry features is to be
stored, contact the Manufacturer.


The silo can be equipped with various accessories, which, in certain circumstances become obligatory, such
as the dust filter.
In fact, in the light of the recent regulatory standards concerning environmental safety it is important to install
dust filters on silos containing dusty materials.
If the above-mentioned filters are installed at the top, ladders with rest landing must be provided to be able to
reach the top of the tank in complete safety to allow operators to carry out inspections and maintenance.

An inspection cover is provided at the top of the silos for inspection inside

SF.SPG35.T.A2.0911.EN 3
SF.SPG35.T.A2.0911.EN

DESIGN AND EXECUTION STANDARDS

Design and execution standards

Silos and accessories are designed and constructed according to the following standards:
1. ENV 1991-1:1996, Eurocode 1-1, Calculation basis and actions on structures
2. ENV 1991-2-1:1996, Eurocode 1-2, Actions on structures-Densities, self-weights and imposed loads
3. ENV 1991-2-3:1996, Eurocode 1-2-3, Actions on structures-Snow loads
4. ENV 1991-2-4:1997, Eurocode 1-2-4, Actions on structures-Wind actions
5. ENV 1991-4:1997, Eurocode 1-4, Calculation basis and actions on structures-actions on silos and
tanks
6. ENV 1993-1-1: 1994/A1:1998, Eurocode 3-1-1, Design of steel structures, general rules and rules for
buildings
7. ENV 1993-4-1:2002, Eurocode 4-1, Silos, tanks and pipelines-Silos
8. ENV 1998-1-1:1997, Eurocode 8-1-1 Design of structures for earthquake resistance -Seismic actions and
general requirements for the structures
9. ENV 1998-4:2000, Eurocode 8-4 Silos, tanks and pipelines
10. UNI EN 131/1 1994 ,Ladders: terminology, types and functional sizes
11. EN ISO 14122-3 : 2001 Stairs, step ladders and guard-rails and subsequent updates.

The following environmental data have also been taken into consideration for the design:
- wind load: 150 kg/m2.
- snow load: 300 kg/m2.
In cases where the actual values are higher than the theoretical data, the Customer must inform the
Manufacturer immediately.

2.2 Documentation and certifications


- Calculation report:
will be supplied if required, on payment, once the seismicity class, wind speed and the maximum snow load
of the Municipality in which the silo is installed are known. The original will be issued (triple copy), directly by
the qualified design engineer.
- Declaration concerning the Standards adopted for the design and production.
- EC Certification:
the European standards do not envisage this type of certification since the silo is an ordinary container for
powders filled by gravity.
It is not a machine because it does not have a mechanical motive power.

Attention
The silos are not designed for use as pressurized containers.
In fact, since there is a possibility of pressure or air flow rate conditions exceeding the normal parameters dur-
ing the filling phase, in order to prevent damage, it is advisable to install:
- an overpressure control Kit
- a relief valve
- a dust filter

Contraindications
Silos are not designed for storing materials that are harmful by contact and/or inhalation, or hazardous from the
bacteriological and viral point of view. Inform the Manufacturer if these needs are to be satisfied.

4 1-Technical Catalogue
1-Technical Catalogue

STANDARD SILOS: Materials and finishes

Material Thickness from-to


Pos. DESCRIPTION FINISH
/
1 Cylinder sections Iron 2.5 to 4 mm Painting
2 Nuts and bolts Steel Galvanization
3 Gasket Polymer material 4 mm
4 Legs Iron HEA140, 160, 180 Painting
5 Provision for filter Iron 800 mm Painting
6 Provision for valve Iron 273 mm Painting
7 Filling pipe Iron 114 mm Painting
8 Bottom cone Iron 3 mm Painting
Painting,
9 Fluidization with sleeves Iron 2 inches galvanized
plug
10 Outlet flange Iron 300 mm Painting

SF.SPG35.T.A2.0911.EN 5
SF.SPG35.T.A2.0911.EN

OPTIONS: Materials and finishes

Material Thickness from-to


Pos. DESCRIPTION FINISH
/
1 Ladder Iron Galvanization
2 Railing Iron Galvanization
3 Provision for IPX Iron 160 mm Painting
4 Connecting gangway Iron 5 mm Galvanization

6 1-Technical Catalogue
1-Technical Catalogue

ACCESSORIES: Materials and finishes

Pos. DESCRIPTION Material Thickness from-to / FINISH


1 Legs extension Iron HEA140, 160, 180 Painting
2 Filling pipes extensions Iron 114 mm Painting
3 Ladder extensions Iron Galvanization
4 Cable gland tube Iron 60 mm Painting
5 Supporting frame Iron Painting
6 Adapter for DUSTSHAKE Iron 2 mm Painting
7 Adapter for FC 1000 mm Iron 2 mm Painting

SF.SPG35.T.A2.0911.EN 7
SF.SPG35.T.A2.0911.EN

MODULAR CODE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
SPG 35

35 = 35 m3 95 = 95 m3
50 = 50 m3 110 = 110 m3 Capacity
65 = 65 m3 125 = 125 m3
80 = 80 m3

3 = Seismic Class 2 (ex S9) Seismic Class


4 = Seismic Class 4 (ex S0)

1 = Standard Version
2 = Heavy

+ = Without Legs
1 = Standard
+++ = Without UF6 = Provision for FC2J13V Provision for filter
TSF = Exhaust pipe UF8 = Provision for FC3J20V
SIL = Provision
for Silotop
+ = Without Provision for VCP
1 = Provision VCP2731C
2 = Provision VCP3751C Provision for IPX
+ = Without
1 = IPX
+ = Without Filling
2 = Inlet spout 219
C= With filling pipe 114 pipe
3 = Inlet spout 273
1 = Inlet spout 168

+ = Without
1 = No.1 2 1/2 sleeve Sleeves (on cap)
2 = No.2 1 1/2 sleeves
3 = both sleeves

+ = Without 5 = Provision for BA150


Bottom cone
1 = Standard (56) 8 = Provision for BA180
D=Twin outlet

+++ = Without V08 = No. 8 holes ( 23 mm)


F04 = No. 4 holes ( 14 mm) M04 = No. 4 2 sleeves with plugs Fluidization
F08 = No. 8 holes ( 14 mm) M08 = No. 8 2 sleeves with plugs
V04 = No. 4 holes ( 23 mm)

+ = Without
Flange at outlet
1 = Standard for V2FS300SN and V2FF300F19N
2 = For VLC/VLQ 300 (XKF751)

+ = Without 3 = With gate at the bottom of the stairs


Ladder
1 = With ladder 4 = With both gates
2 = With gate at the top of the stairs

+ = Without 4 = Two openings (180)


Railing
1 = With one opening 5 = Two openings (90)
2 = With two openings 6 = Three openings ("T")
3 = With three openings

+ = Without 4 = 3950 mm
1 = 3660 mm 5 = 4050 to 4200 mm Connecting gangway
2 = 3750 mm 6 = 4200 to 4350 mm
3 = 3850 mm 7 = 4350 to 4500 mm

+ = Without
1 = Standard cycle Surface treatment
2 = High protection cycle
3 = Hot galvanization

2 = Ral 1013
6 = Ral 5012
D = Ral 5010
H = Ral 7032
G = Ral 7035 Shade
Q = Ral 7044
L = Ral 9001
M = Ral 9002
S = Ral 9016
V = Ral 9006 per T: 100-150

8 1-Technical Catalogue
1-Technical Catalogue

STANDARD SUPPLY


The standard supply of the Silo SPG35 consists of:

- Panels with flanges


- Provision for filter
- Inspection cover
- Provision for relief valve
- Provision for filling pipe
- Filling pipe
- No. 2 2 sleeves for level indicators
- Bottom cone (56 inclination)
- Outlet spout diameter 300mm with round flange
- Legs complete with wind bracing
- Nuts and bolts: Class 8.8 glavanized steel.
- Polymer gasket
- Fluidization 4 sleeves
- Standard inside and outside finish

SF.SPG35.T.A2.0911.EN 9
SF.SPG35.T.A2.0911.EN

RANGE

3588
(external)

380

1158
SPG35.125

1508
SPG35.110

400
1508
SPG35.095
1508

SPG35.080
1508
12064

SPG35.065
10556

1508
9048

SPG35.050
H

7540

1508
6032

SPG35.035
4524

1508
3016

1508

400
2517
3917

1200
1400

Throughput Capacity Cylinder sec-


Code H Panels
m (*)
3
T (**) tions
SPG35.035 7313 35 50 2 8
SPG35.050 8821 50 70 3 12
SPG35.065 10329 65 90 4 16
SPG35.080 11837 80 112 5 20
SPG35.095 13345 95 135 6 24
SPG35.110 14853 110 150 7 28
SPG35.125 16361 120 170 8 32

(*) Silo internal volume


(**) Specific weight of reference material (cement): 1.4 kg/dm3
10 1-Technical Catalogue
1-Technical Catalogue

RANGE: SPG35.035

3468

1150
400
3016

1508
2800
8241
7311

2517
400
2400

3420

2548
1400
1200

50
33

25
94

15

Nominal flow rate Max. theoretical flow Max. useful flow Min. useful flow
internal
Code [ m3 ] rate rate rate
[ mm ]
[ m3 ] [ m3 ] [ m3 ]
SPG35.035 3468 35 37 33 11.85

SF.SPG35.T.A2.0911.EN 11
SF.SPG35.T.A2.0911.EN

RANGE: SPG35.050

3468

1150
400
4524
9749

1508
2800
8819

400

2517
2400

3420

2387
1400
1200
33

50
25
94

15

Nominal flow rate Max. theoretical flow Max. useful flow Min. useful flow
internal
Code [ m3 ] rate rate rate
[ mm ]
[ m3 ] [ m3 ] [ m3 ]
SPG35.050 3468 50 51 47 11.85

12 1-Technical Catalogue
1-Technical Catalogue

RANGE: SPG35.065

3468

1150
400
6048
11257
10327

400

1508
2800

2517
2400

3420

2204
1400
1200
33

50
94

25
15

Nominal flow rate Max. theoretical flow Max. useful flow Min. useful flow
internal
Code [ m3 ] rate rate rate
[ mm ]
[ m3 ] [ m3 ] [ m3 ]
SPG35.065 3468 65 65 61 11.85

SF.SPG35.T.A2.0911.EN 13
SF.SPG35.T.A2.0911.EN

RANGE: SPG35.080

3468

1150
400
7540
12765
11835

400

1508
2517
2400

3420
2588

1400
1200
33

50
25
94

2400
15

Nominal flow rate Max. theoretical flow Max. useful flow Min. useful flow
internal
Code [ m3 ] rate rate rate
[ mm ]
[ m3 ] [ m3 ] [ m3 ]
SPG35.080 3468 80 79 75 11.85

14 1-Technical Catalogue
1-Technical Catalogue

RANGE: SPG35.095

3468

1150
400
9048
14273
13343

400

1508
2400

2517
3420
1956

1400
1200

50
33

2400 25
94

15

Nominal flow rate Max. theoretical flow Max. useful flow Min. useful flow
internal
Code [ m3 ] rate rate rate
[ mm ]
[ m3 ] [ m3 ] [ m3 ]
SPG35.095 3468 95 93 89 11.85

SF.SPG35.T.A2.0911.EN 15
SF.SPG35.T.A2.0911.EN

RANGE: SPG35.110

3468

1150
400
10556
15781
14851

400

1508
2517
2400

3420

2249
1400
1200

50
33

2400 25
49

15

Nominal flow rate Max. theoretical flow Max. useful flow Min. useful flow
internal
Code [ m3 ] rate rate rate
[ mm ]
[ m3 ] [ m3 ] [ m3 ]
SPG35.110 3468 110 107 103 11.85

16 1-Technical Catalogue
1-Technical Catalogue

RANGE: SPG35.035

3468

1150
400
12064
17289
16359

400

1508
2517
2400

3420

2632
1400
1200

50
33

2400 25
94

15

Nominal flow rate Max. theoretical flow Max. useful flow Min. useful flow
internal
Code [ m3 ] rate rate rate
[ mm ]
[ m3 ] [ m3 ] [ m3 ]
SPG35.125 3468 125 121 117 11.85

SF.SPG35.T.A2.0911.EN 17
SF.SPG35.T.A2.0911.EN

Seismic zone

Three versions are available, suitable for the following ag (horizontal seismic acceleration) values envisaged
by the European regulatory standards on the matter of seismicity.

Code Zone [ ag ]
S9 2 0.25 g
S6 3 0.15 g
S0 4 0.05 g

18 1-Technical Catalogue
1-Technical Catalogue

OPTIONS: Version

Standard and Heavy duty


In addition to the standard version, the heavy duty version is also available.
HEAVY DUTY SILO
- The four 4mm thick panels which form the first cylinder section are identified by a metal tag fixed to the flanges
by means of a tie.
- The number 4 is stamped on this tag.
- This cylinder section must be the first starting from the bottom, i.e. it must be positioned between the cylinder
cone and the subsequent cylinder sections.
- During the assembly of the panels and the cylinder sections, the sealant or the gasket provided must be ap-
plied according to the procedures described on page 13.
- The individual cylinder sections must be assembled on the ground thereby saving time.

SPG35.035 SPG35.050 SPG35.065 SPG35.080 SPG35.095 SPG35.110 SPG35.120

(*) 4 mm cylinder section - Silomantelschuss 4 mm - Virole de 4 mm - Virola di 4 mm

SF.SPG35.T.A2.0911.EN 19
SF.SPG35.T.A2.0911.EN

OPTIONS: Legs

SUPPORTING LEGS
Made of HEA sections.
The section depends on the size of the silo and its degree of earthquake resistance.

1- LEGS MADE OF HEA 140
The Table showing the specific models and plan drawing is given below.

Models in version for zone 4 Models in version for zones 2 and 3


SPG35.035 -
SPG35.050 -
SPG35.065 -
SPG35.080 -

92 115
2400
92

8
20
2
1
400
300
2400

115

300
400
23
2

2- LEGS MADE OF HEA 160


The Table showing the specific models and plan drawing is given below.

Models in version for zone 4 Models in version for zones 2 and 3


SPG35.095 SPG35.035
SPG35.110 SPG35.050
SPG35.125 SPG35.065
SPG35.080

92 115
2400
92

8
20

2
1
400
300
2400

115

300
400
23
2

20 1-Technical Catalogue
1-Technical Catalogue

3- LEGS MADE OF HEA 180


The Table showing the specific models and plan drawing is given below.

Models in version for zone 4 Models in version for zones 2 and 3


SPG35.095
SPG35.110
SPG35.125

400
65 87
2400

65
8
2

400
300
2400

18

87
2

300
21
3

WIND BRACING
The special layout of the wind bracing makes it possible to have a vast area through which the screw conveyors
can project out.
As a result, significant variations in the inclinations and lateral movements of the screw conveyors are permitted
at the work site

SF.SPG35.T.A2.0911.EN 21
SF.SPG35.T.A2.0911.EN

OPTIONS: Provision for filter

COVER
The dust filter is installed on this cover, if required.


15
1150

1200
1150
1100

1150
5
14
n.24
250

3
1200

In compliance with the current anti-pollution standards in force, it is obligatory to fit a dust removal system which
could be positioned on the ground or on the top of the silos.

1 - FILTER ON SILO
If positioned at the top of the silo, the material collected during the cleaning cycle is unloaded directly into the
silo. For more information on filters see page 48 .
NOTE: It is advisable to fit a separate filter on each silo.
The range includes three models.
Standard mounting position is shown below.

Code Pos. Type


Code e f i h A A1
Component Filter
UF600 FNC1 1 FC2J13V 633 / 608 190 1075 1860
UF800 FNC2 2 FC3J20V 813 / 788 240 7075 1860
UFN8001 SIL 3 SILOTOP 833 808 783 229 1340 2090
A = filter+filter flange dimensions
A1 = dimensions with filter open for maintenance
22 1-Technical Catalogue
1-Technical Catalogue

EXHAUST PIPE
It is necessary if the filter is positioned on a hopper placed on the ground. Silo and hopper will be connected by
means of a flexible duct. The product can be recovered by inserting a container under the hopper.

114.3

171

8
540

156
155 200

1
8

114.3

220
180

1
8
8

115.5
1200

XKF 10.1

L
Type Composition of outlet tubes
[ mm ]
SPG35.035 No. 1 x 6.020 6.020
SPG35.050 No. 1 x 6.020 No. 1 x 1.530 7.550
SPG35.065 No. 1 x 6.020 No. 1 x 3.040 9.060
SPG35.080 No. 1 x 6.020 No. 1 x 4.510 10.530
SPG35.095 No. 2 x 6.020 12.040
SPG35.110 No. 2 x 6.020 No. 1 x 1.530 13.570
SPG35.125 No. 2 x 6.020 No. 1 x 3.040 15.100

SF.SPG35.T.A2.0911.EN 23
5.0 OPTIONS
SF.SPG35.T.A2.0911.EN

OPTIONS: Provision for VCP - Relief valve

The relief valve has the function of preventing pressure excesses, during the silos filling phase or fluidization
of material, or under-pressure during the emptying.
Two types of fitting are available for the relief valve:
25 25
- 273
- 375
A VCP pressure control valve is added to the stub pipe. For more information see page 48.
65

2
856
2200


65

65

50
120

120
4

273 356

24 1-Technical Catalogue
1-Technical Catalogue

OPTIONS: Provision for IPX


Suitable for pressure indicator device. If required, it is supplied complete with blind flange.

6
321

196
n.6 8.5 220
holes
160
Bohrungen
trous
fori
25

50
R5
90
25

0
20
110
0

SF.SPG35.T.A2.0911.EN 25
SF.SPG35.T.A2.0911.EN

OPTIONS: Filling pipe

FILLING STUB PIPE


Instead of filling pipe.
This accessory is generally used if loading is mechanical (screw conveyor, chain conveyor, belt conveyor, etc.).
A blind counter flange is always provided.

114.3
171

Composition of filling L
8

Type
540 pipes [ mm ]
156

SPG35.035 No. 1 x 6.020 6.020


SPG35.050 No. 1 x 6.020 No. 1 x 1.530 7.550
200
SPG35.065 No. 1 x 6.020 No. 1 x 3.040 9.060
155

1
8 SPG35.080 No. 1 x 6.020 No. 1 x 4.510 10.530
114.3 SPG35.095 No. 2 x 6.020 12.040
SPG35.110 No. 2 x 6.020 No. 1 x 1.530 13.570
220
SPG35.125 No. 2 x 6.020 No. 1 x 3.040 15.100
180

8
1
8

115.5
1200

XKF 10.1

Used for storing material inside the silo .


It is positioned outside by means of special plates to be bolted to the flanges of the panels that comprise the
cylinder.
In the absence of a filling pipe the stub pipe complete with blind flange is supplied.
8
321

221

B C Holes
centre internal
A
distance
Spout external No.
between
B

holes
0
R55
90

168 220 200 170 4 13.5


C
219 278 250 221 4 13.5
A
273 328 300 275 8 13.5

1428

26 1-Technical Catalogue
1-Technical Catalogue

OPTIONS: Sleeves on cap

Two models are available:


- 2 boss (complete with plug)
Suitable for maximum level indicator blade.
- 1 boss (complete with plug)
Suitable for continuous level indicator in place of minimum level.
Consists of a 2 boss + reduction.

25 25

65

2
856
2200


65

65

50

DN65 2 sleeves UNI/DIN EN 10241 medium series


Outer diameter d = 82 mm
Height h = 65 mm
DN40 1 sleeves UNI/DIN EN 10241 medium series
Outer diameter d = 54.5 mm
Height h = 48 mm

SF.SPG35.T.A2.0911.EN 27
SF.SPG35.T.A2.0911.EN

OPTIONS: Bottom cone

It is provided with four brackets, welded at 90 to one another, and the wind bracing must be bolted to these.
400

10
2517

1215
3917

272
249

8
1400

UPPER AND LOWER FLANGE DIMENSIONS


Upper flange

n.60
holes
Bohrungen
trous
fori

198
8

n.8 350
holes
Bohrungen
trous
fori

300
500


13

1913
2070

28 1-Technical Catalogue
1-Technical Catalogue

Some variations are available which, however, only concern the bottom cone.

CONE WITH FLANGE FOR VIBRATING BIN EXTRACTOR BA 150

454
1495

CONE WITH FLANGE FOR VIBRATING BIN EXTRACTOR BA 180


244
1568

CONES WITH DOUBLE OUTLET SPOUT


Dimension of sleeves 2.
These are supplied complete with plugs.
In the order phase, the customer must inform the Manufacturer if 1 fluidization nozzles are to be used, so that
2 to 1 reductions can be supplied.
The positions of the holes are shown in the attached drawings.

2"

DN50 2 sleeves UNI/DIN EN 10241 medium series


Outer diameter 66mm
Height 56mm
SF.SPG35.T.A2.0911.EN 29
SF.SPG35.T.A2.0911.EN

OPTIONS: Fluidization
ACCESSORIES FOR FLUIDIZATION
In applications where a fluidization system is provided, the cones may be supplied with holes or sleeves, de-
pending on the type of fluidizer used.

1- HOLES FOR FLUIDIZERS
Suitable for plates and for vibrating bin aerators (for diameter, quantity and position, see attached Table). For
more information regarding fluidizers see page 48.

10
1215
272
30
60

0
0

9
71

63
5
2030

Plates Vibrating bin aerators


Code Holes Code Holes
No. No.
F04 4 14 V04 4 23
F08 8 14 V08 8 23

2- SLEEVES
FOR FLUIDIZERS

2.1-SIMPLE CONES
Dimension of sleeves 2. These are supplied complete with plugs.
In the order phase, the customer must inform the Manufacturer if 1 fluidization nozzles are to be used, so that
2 to 1 reductions can be supplied.
The positions of the holes are shown in the attached drawings.

Plates
Code
No. of Holes Dimensions of sleeves
M04 4
2
M08 8

30 1-Technical Catalogue
1-Technical Catalogue

OPTIONS: Flange at outlet

Square flange
Suitable for gate valve

6
433
24 385 24

24
128.3

433
385
25
3
5
2.
1

n.60
holes
Bohrungen 24
trous flange
Round
fori
Suitable for butterfly valve

n.8 350
holes
Bohrungen
trous
fori 1 4

300
500

13

A series of valves can be connected to the


flange. For more information see page 46

SF.SPG35.T.A2.0911.EN 31
SF.SPG35.T.A2.0911.EN

OPTIONS: Ladder

32 1-Technical Catalogue
1-Technical Catalogue

HOOP LADDER
1- LADDER
Used for reaching the top of the roof.
It is constructed according to the latest European provisions in terms of operator safety (consult page 5).
A hoop guard is provided 2000-2500mm from the ground.
The guard arches have a radius of 350 mm and are present every 1120 mm
The 450mm long steps are made of 3+2 non-slip checker plate or safety tread plate.

The inverted C shape facing downwards, the type of sheet metal used and the two side openings prevent
water and mud stagnation, ensuring the operator a safe hold while climbing up and coming down.
The centre distance between one step and the next is 285mm. The Table shows the distances of the rest land-
ing from the ground. According to the standards, this value must be < 10 m.
Type H [ mm ] Note
SPG35.035 / n.p.
SPG35.050 / n.p.
SPG35.065 4430
SPG35.080 5930
SPG35.095 7451
SPG35.110 6716
SPG35.125 8223

Its shape prevents the operator from leaning over dangerously beyond the guard while moving from the lower
ladder upwards. It may be defined as a safety cage.

2- SAFETY ACCESSORIES
2.1- Safety grille
Applied at the lower end of the ladder. Prevents access to the work site by outsiders. It must be fixed to the
bottom ring of the guard by means of a padlock.
2.2- Door for upper railing
Applied to the railing at the entrance to the ladder. Prevents accidental fall through it. (Fig. 1)

Fig.1 Fig.2
SF.SPG35.T.A2.0911.EN 33
SF.SPG35.T.A2.0911.EN

OPTIONS: Railing

A railing can be mounted at the top of the silos so that operators can move safely.
A railing is indispensable when it is necessary to get to the top of the silos with a certain frequency. It must
always be connected with the hoop ladder.
If no guards are present, the operator must use the necessary means for safe access to the roof.

643 428 212


1158

1158

1158
158

158

158

Because of the modular composition the order can be placed depending on the number of openings necessary.
Ladders or gangways may be positioned at these openings.

Guard with one opening suitable for ladder or gangway


12 MP1 sectors 856mm long, are provided (Fig.1).

Fig.1

34 1-Technical Catalogue
1-Technical Catalogue

Guard with two openings


Suitable for silo provided with ladder + a gangway
11 MP1 sectors 856mm long, are provided (Fig.2).

Fig.2

Guard with three openings


Suitable for silo with hoop ladder and two gangways
9 MP1 sectors 856mm long, 1 MP2 sector 643mm long and 1 MP4 sector 212mm long are provided (Fig.3).

Fig.3

Guard with two opposite openings (at 180).


Suitable for two gangways (Code PAR 35.4).
10 MP1 sectors 856mm long, and 2 MP3 sectors 428mm long are provided (Fig.4).

Fig.4

SF.SPG35.T.A2.0911.EN 35
SF.SPG35.T.A2.0911.EN

Guard with two openings (at 90).


Suitable for silo with two gangways (Code PAR 35.5).
10 MP1 sectors 856mm long, 1 MP2 sector 643mm long and 1 MP4 sector 212mm long are provided (Fig.5).

Fig.5

Guard with three T shaped openings (Code PAR 35.6).


Suitable for silo with three gangways.
8 MP1 sectors 856mm long, 1 MP2 sector 643mm long, 2 MP3 sectors 428mm long and 1 MP4 sector
212mm long are provided (Fig.6).

Fig.6

36 1-Technical Catalogue
1-Technical Catalogue

OPTIONS: Connecting gangway

Serves to connect the roofs of two or more silos positioned side by side. If the standard model is to be used,
while preparing the plant lay-out, make sure the fixed centre distance is 3660mm.

Finish: hot galvanization

3660

Alternatively, it is possible to have the following centre distances (see Table 1):

I
Silos centre distances [ mm ]
3750
3850
3950
4050 to 4200

I
4200 to 4350
4350 to 4500

Tab. 1

SF.SPG35.T.A2.0911.EN 37
SF.SPG35.T.A2.0911.EN

OPTIONS: Surface treatment and colours

SURFACE TREATMENT

EXTERNAL
+ = none (unfinished silo)
1 = Standard cycle
SA 21/2 + single-component synthetic alkyd primer (80 micron)
+ single-component alkyd enamel (40 micron)
(total thickness 120 micron)
2 = High protection cycle
SA 21/2 + epoxy primer containing zinc phosphate (80 micron)
+ bicomponent polyurethane enamel (40 micron)
(total thickness 120 micron)
3 = Hot galvanization

INTERNAL (standard)
SA 2 1/2 + single-component synthetic alkyd primer (80 micron thickness)

COLOUR

COLOUR RAL

2 RAL 1013
6 RAL 5012
D RAL 5010
H RAL 7032
G RAL 7035
Q RAL 7044
L RAL 9001
M RAL 9002
N RAL 9010
S RAL 9016
V RAL 9006 for T: 100-150 purple

38 1-Technical Catalogue
1-Technical Catalogue

ACCESSORIES: Legs extension

Everytime the customer requires a distance of the outlet spout from the ground more than the standard (1,400
mm), the legs must be extended.
A maximum distance of 2,540 mm is permitted, which can be obtained by adding stub pipes of varying heights
(at 285 mm steps) as shown in the following diagrams.
For distances more than 2,540 mm an intermediate floor must be used.
Obviously it will be necessary to extend the hoop ladder, filling pipe and/or the exhaust pipe, if present .
15

1140
285
570
855
15
30 0

40 0
40

0
30
0

2
8
173

178

The stub pipes must be positioned as shown in the drawing. With this accessory and the wind bracings there
are no modifications.

Finish: like the silo

standard leg

HEA220

Extension height Distance of outlet spout from


Code kg
[ mm ] ground
0285 285 1685 200
0570 570 1970 256
0855 855 2255 312
1140 1140 2540 372

SF.SPG35.T.A2.0911.EN 39
SF.SPG35.T.A2.0911.EN

ACCESSORIES: Filling pipe and exhaust pipe extension

Everytime the customer requires a distance of the outlet spout from the ground more than the standard (1,400
mm), the filling pipe and/or exhaust pipe will also have to be extended.
A series of extensions in various lengths are available.

Distance of outlet spout from Height of


Module
Code ground frame/s
[ mm ] [ mm ] TPR1710 TPR2280 TPR2850

TPR35.1710 3110 1710 X

TPR35.2280 3680 2280 X

TPR35.2850 4250 2850 X

3420
TPR35.3420 4820 XX
(1710+1710)
3990
TPR35.3990 5390 X X
(1710+2280)
4560
TPR35.4560 5960 XX
(2280+2280)
5130
TPR35.5130 6530 X X
(2280+2850)
5700
TPR35.5700 7100 XX
(2850+2850)

40 1-Technical Catalogue
1-Technical Catalogue

ACCESSORIES: Ladder and cable gland tube extension

Ladder extension

H = 285 mm H = 570 mm H = 855 mm H = 1140 mm


Cable gland tube

60 x 2.9 mm

SF.SPG35.T.A2.0911.EN 41
SF.SPG35.T.A2.0911.EN

ACCESSORIES: Supporting frame

In applications where the distance of the outlet spout from the ground must be 3.1 and 7.1 m, supporting frames
can be used which can be combined appropriately to satisfy these needs.
For maintenance on machines downline of the silo (valves, fluidization, screw conveyors, etc.) an intermediate
floor consisting of a treading floor made of metal grating, surrounding protective railing and ladder for access
are available.

Version with single frame Version with double frame

42 1-Technical Catalogue
1-Technical Catalogue

As shown in the following diagrams, there are three types, all made of HEA 220 sections.

h1
COMBINATIONS TABLE
The possible combinations are shown in the following Table:

Distance of outlet spout from Height of


Module
Code ground frame/s
[ mm ] [ mm ] h1= 1710 h1= 2280 h1= 2850
STP 1 3110 1710 X
STP 2 3680 2280 X
STP 3 4250 2850 X
3420
STP 4 4820 XX
(1710+1710)
3990
STP 5 5390 X X
(1710+2280)
4560
STP 6 5960 XX
(2280+2280)
5130
STP 7 6530 X X
(2280+2850)
5700
STP 8 7100 XX
(2850+2850)

Finish: like the silo

SF.SPG35.T.A2.0911.EN 43
SF.SPG35.T.A2.0911.EN

From the treading floor it is possible to take the ladder to access the roof.
The treading floor is made of non-slip metal grating in order to prevent stagnation of water, snow or mud.
For intermediate heights, for e.g. 4.3 m, the raised feet Kit can be used (see page 40).

Finish: Hot galvanization

All the models are supplied dismantled and complete with nuts and bolts.

Obviously, if these accessories are present, the filling pipe and/or exhaust pipe will also have to be extended.

44 1-Technical Catalogue
1-Technical Catalogue

ACCESSORIES: Adapters for filter

The accessories include two adapters: one for round clamped filter 1000, the other for a DUSTSHAKE
polygonal filter. For information regarding filters, see page 48.

Adapter for round filter

Adapter for DUSTSHAKE

SF.SPG35.T.A2.0911.EN 45
SF.SPG35.T.A2.0911.EN

Commercial components present in silos

INSPECTION COVER
Standard

485
100

2 1.5

400
n.15
holes
Bohrungen
trous
fori

Description
- Gasket on ETB65 ANTIOIL 4mm thick.
- No. 15 M8x20 screws (galvanized)
Finish
- Painted

ADHESIVE GASKET

ADHESIVE GASKET
The standard supply includes an adhesive gasket consisting of closed-cell polymer material.
If applied between the cylinder components, it isolates the material stored inside the silo completely from the
outside environment.

46 1-Technical Catalogue
1-Technical Catalogue

6.8 Recommended accesories to be mounted on the silo

BA Bin activator Cylindrical dust filter SILO-


(cat. WA.13 T.) TOP
(cat. WA. 3505.02 T.)

Butterfly valve
(cat. WA. 03041)
Round filter WAMECO
(cat. WA. 03505 T.)

Butterfly valve with square


flange
(cat. WA. 3005 T.)

Dust filter
DUSTSHAKE
(cat. WA. 03510.40 T.)

Butterfly valve
(cat. WA. 3010 T.)

Slide valve
(cat. WA. 03020)

VCP Pressure control valve


Pneumatic descent systems
(cat. WA. 03041)

SF.SPG35.T.A2.0911.EN 47
NOTE:. The data given in this catalogue are not binding and may undergo changes at any time.