General
General description
System / Type of drive The conveying direction of the carrier is set through an external blower sta-
tion, which can switch between vacuum and pressure. Since the station DST
can receive as well as send, the conveying direction of the carrier is both
sided (single tube reversing principle)
Station-selection The operation is done menu-controlled by a keyboard and a clear text dis-
play. (individually programmable target numbers and addresses). The key-
board offers the user a 5-digit target selection with an accompanying 16-
digit user text.
Carrier store Selecting a target station is possible in every condition of the unit. The target
is saved in case of a busy system.
Target confirmation The system controls the condition of the receiving station, if sending to the
selected receiving station is possible.
Control Microprocessor-controlled.
Power failure The system is built in a way that after a power failure it is self-examining and
if necessary self-repairing.
System diagnosis A self-disturbance program, a control of the condition of the unit and the
course of operation make a safe operation possible.
Mounting
Safety requirements The station was tested according to the office- and industry standards. (EMV
etc.)
Accessories Wire basket, arrival signal AKS, holding device for carriers
Datasheet
Technical data
Electric supply The station is supplied over the power supply unit with 30V
Electricity uptake of the station when ready for operation120 mA
Electricity uptake of the station when receiving or sending1,2 -1.5 A
Electricity limitation of the station4 A
Noise level Measurement at a 1meter distance under standard test environment and
suitable instruments. Carrier dispatching through bypass / transit tube:
65dbA Carrier receiving at incoming tube:67dbA
Dispatch and receipt weight The carrier can be loaded with a maximal capacity of 5kg.
DST-END terminal
Type 2: End terminal with top forwarding tube connection
The following mounting dimensions of the station must be observed
thoroughly:
Special Codes
There are two additional special codes. It is the special code 99991 and special code 99992.
Code 99991
Entering special code 99991 + PTT, the system displays:
99997 READY
Entering the right password (e.g. code) followed by PTT key, the system
WRONG NUMBER
(LCU) changes to TEST status. This works only when system is in READY
status.
Once in TEST status, it is possible to get the control to any station
equipped with display and keyboard by entering the right code and PTT
key. If so, diagnostic functions are available as described in 3.3.9. The
only difference is, that every control key has to be confirmed by PTT
key.
Entering the special code 99991 + PTT during TEST status, the system
changes to INIT (first phase only), followed by REDAY status.
Code 99992
99992 READY Entering special code 999992 + PTT, the system displays:
SELFSELECT
Pressing the PTT key again, starts the station a transit to itself. The car-
rier enters the system and should return in few moments. This works
only when system is in READY status.