Test: Oracle StorageTek SL3000 Installation Consultant Online Assessment

Review your answers, feedback, and question scores below. An asterisk (*) indicates
a correct answer.
This 40-question assessment test is the final on-line component of the Oracle
StorageTek SL3000 Installation Consultant guided learning path. This assessment
will allow you to test your knowledge level of the information learned from the
StorageTek SL3000 courses. Passing at >80% of this assessment makes you eligible to
become an Oracle Installation Consultant for this subject matter.
SL3000 Mod Library
Five SL3000 Modules
(Answer all questions in this section)

1. Which of the following statements is FALSE? Mark for Review


(1) Points

Host partition connections can use either SCSI or HLI

Storage cells and drives not allocated to any partition can be accessed by
any host (*)

Storage cells and tape drives allocated to a partition can be used only by
the host(s) assigned to that partition.

For SCSI host connections, the entire CAP can be allocated for exclusive use
by the partition or they can be left unallocated for common use by all SCSI
partitions

The remote SLC must be used for partitioning setup.

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

2. Which card is the backplane for all other cards in the ECM?
Mark for Review
(1) Points

HBB

HBCR

PUM (*)

PUN
[Correct] Correct

3. Which card controls the tape drives? Mark for Review


(1) Points

PUN

HBCR

HBT (*)

HBB

[Correct] Correct

4. What happens if the module ID block is incorrect? Mark for


Review
(1) Points

Initialization takes too long.

The library will fail to initialize. (*)

The TallBot will become unmanageable.

Nothing

[Correct] Correct

5. What is being done when the following procedure is executed? Add


another PDU of the same rating, Balance the number of required drive DC power
supplies for each PDU, Move the power supply in the Rail Module Assembly from the
second slot to the third slot, Move the ECM cPCI power supply from one side of the
center line to the other, Turn on both PDU power switches, Turn on both ECM power
switches. Mark for Review
(1) Points

Converting from N+1 to 2N power. (*)

Adding extra PDUs to the rail power supply


Adding extra PDUs to the base power supplies

Converting from N+1 to 2N+1 power.

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

Page 1 of 8
=============================================================================

Test: Oracle StorageTek SL3000 Installation Consultant Online Assessment

Review your answers, feedback, and question scores below. An asterisk (*) indicates
a correct answer.
This 40-question assessment test is the final on-line component of the Oracle
StorageTek SL3000 Installation Consultant guided learning path. This assessment
will allow you to test your knowledge level of the information learned from the
StorageTek SL3000 courses. Passing at >80% of this assessment makes you eligible to
become an Oracle Installation Consultant for this subject matter.
SL3000 Mod Library
Five SL3000 Modules
(Answer all questions in this section)

6. Which of the following is NOT a licensed feature of the SL3000?


Mark for Review
(1) Points

Service

Dual ports

Dual TallBots

Partitioning

Native fibre channel (*)

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

7. The Select Active Cells tool is used in which instance? Mark


for Review
(1) Points

If the entire library is licensed.


If the library has not been partitioned

If the library is being partitioned (*)

This tool is always required

[Correct] Correct

8. Where is the documentation for Power Distribution and Cooling


requirements found? Mark for Review
(1) Points

The Tape Support Web Site (*)

The System Assurance Center

My Oracle Support

The Customer Portal

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

9. Which of these statement is true for SL3000 license keys? Mark


for Review
(1) Points

Generated at the time of the sales order, based on the serial number of the
base and must be installed by a service technician

Generated at the time of sale, based on the library serial number, and can be
installed by the customer (*)

Generated at any time, based on the library serial number and must be
installed by a service technician

Generated at the time of installation and based on the serial number of the
Base
[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular
Library training for more information.

10. The Drive Expansion Module can house how many tape drives? Mark
for Review
(1) Points

16

48

32 (*)

56

24

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

Page 2 of 8
=======================================================================

Test: Oracle StorageTek SL3000 Installation Consultant Online Assessment

Review your answers, feedback, and question scores below. An asterisk (*) indicates
a correct answer.
This 40-question assessment test is the final on-line component of the Oracle
StorageTek SL3000 Installation Consultant guided learning path. This assessment
will allow you to test your knowledge level of the information learned from the
StorageTek SL3000 courses. Passing at >80% of this assessment makes you eligible to
become an Oracle Installation Consultant for this subject matter.
SL3000 Mod Library
Five SL3000 Modules
(Answer all questions in this section)

11. Where do direct power and control signals for the TallBot come
from and how are these terminated? Mark for Review
(1) Points

Power and control signals for the TallBot come from the Base Module and power
terminators are stored at the beginning of each rail.

Power and control signals for the TallBot come from the ECM which is directly
connected to the TallBot. Rail terminators are stored at the beginning of each
rail.
Power and control signals for the TallBot come from the DEM and power
terminators are stored at the end of each rail.

Power and control signals come from two copper strips separated by an
insulator. Rail power terminators are installed at each end of the power strips.
(*)

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

12. Assuming an SL3000 with a Base, DEM, and three CEMs, what is the
maximum number of cleaning cartridges that can be stored in the reserved system
cells. Mark for Review
(1) Points

35

38

15

27 (*)

30

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

13. Where can card and component functions as well as LED status
indicators and their meaning be found? Mark for Review
(1) Points

The Oracle SPLAT WebSite

StorageTek System Assurance Guide located on the Tape Support Website

StorageTek SL3000 Modular Library System Principles of Operation found on the


Tape Support Website (*)

My Oracle Support
[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular
Library training for more information.

14. What does the HBB card do? Mark for Review
(1) Points

It is the library controller.

It is the processor card for the TallBot. (*)

It is the tape drive controller.

It is the safety interface controller.

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

15. Which card provides the Safety interface controls and power
distribution for accessories? Mark for Review
(1) Points

HBB

HBCR

PUN (*)

PUK

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

Page 3 of 8
=============================================

Test: Oracle StorageTek SL3000 Installation Consultant Online Assessment

Review your answers, feedback, and question scores below. An asterisk (*) indicates
a correct answer.
This 40-question assessment test is the final on-line component of the Oracle
StorageTek SL3000 Installation Consultant guided learning path. This assessment
will allow you to test your knowledge level of the information learned from the
StorageTek SL3000 courses. Passing at >80% of this assessment makes you eligible to
become an Oracle Installation Consultant for this subject matter.
SL3000 Mod Library
Five SL3000 Modules
(Answer all questions in this section)

16. The SL3000 has both positive and negative numbering for slot and
drive columns. Where is the center line or reference point and what is the highest
column number possible? Mark for Review
(1) Points

On the left edge of the Base module. The highest column number possible is
-18 and +18 in the AEM.

On the left edge of the PEM module. The highest column number possible is -18
and +18 in the AEM

On the left edge of the Base module. The highest column number possible is
-31 and +31 in the AEM. (*)

On the right edge of the Base module. The highest column number possible is
-1 and +1 in the PEM.

[Correct] Correct

17. How is the Reach Safe Sensor used in the TallBot? Mark for
Review
(1) Points

To sense whether or not a cartridge is present in the CAP.

To determine a safe clearance exists between the hand and the cartridge
walls. (*)

To ensure the TallBot doesnt cause electrical shock to service support


personnel when touching the TallBot.

To ensure the rail doesnt cause electrical shock to service support


personnel when touching the TallBot

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

18. What is the main purpose of a library audit? Mark for Review
(1) Points
To ensure the Dynamic World Wide Names are properly assigned (including the
elevator, the PTP and the CAP).

To make sure the customer is charged correctly for their service contract.

To help determine the number of cartridges the customer has stored in the
Base Module.

To create a cartridge database and to ensure the integrity of the cartridge


database by checking each accessible cell location (*)

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

19. There can only be one of these in a library system and it must be
placed to the left of the Base. It is similar in structure to the Base Module but
its primary function is to add more drive bays. It contains 153 to 521 additional
physical slots, and an optional CAP. Mark for Review
(1) Points

BASE

DEM (*)

AEM

PEM

CEM

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

20. Which of the following are components of the TallBot? Mark


for Review
(1) Points

Preloaded CAP, gears and motors, copper strips for grounding the library,
brushes, proximity sensor and bar code scanner

Preloaded transfer mechanisms with short-term storage, gear and track, copper
strips for power and signal, brushes, proximity sensor and bar code scanner
Preload assembly, reach safe sensor, brushes, proximity sensor and bar code
scanner (*)

Preloaded transfer mechanisms with short-term storage, gear and track, copper
strips for power and signal, brushes, proximity sensor and bar code scanner

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

Page 4 of 8
=============================================================

Test: Oracle StorageTek SL3000 Installation Consultant Online Assessment

Review your answers, feedback, and question scores below. An asterisk (*) indicates
a correct answer.
This 40-question assessment test is the final on-line component of the Oracle
StorageTek SL3000 Installation Consultant guided learning path. This assessment
will allow you to test your knowledge level of the information learned from the
StorageTek SL3000 courses. Passing at >80% of this assessment makes you eligible to
become an Oracle Installation Consultant for this subject matter.
SL3000 Mod Library
Five SL3000 Modules
(Answer all questions in this section)

21. Why arent drive trays replaced if a tape drive is faulty? Mark
for Review
(1) Points

They are tied to entitlement and therefore, if a drive has problems, the
entire drive tray is decommissioned.

It is common for a drive tray to be replaced.

They are tied to entitlement, only the drives within the tray are replaced.
(*)

Replacing them is too laborious. If a drive has problems, the entire drive
tray is decommissioned.

[Correct] Correct

22. What panel numbers are associated with a Base, a DEM, and two
CEMs (one to the left of the DEM and one to the right of the Base)? Mark for
Review
(1) Points
Panels 8, 10, 12, and 14

Panels 10 - 17

Panels 1 - 8

Panels 8 - 15 (*)

Panels 1 - 4

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

23. What does a Cartridge Presence sensor do? Mark for Review
(1) Points

It lets the hand assembly know that a cartridge is present inside the hand
assembly. (*)

It terminates the power and control signal to the TallBot is a Cartridge is


present.

It determines whether or not the reach is safe to get or put the cartridge in
a cell.

It tells the ECM to supply power to the rail for the TallBot.

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

24. Which of the following correctly describes the function of the


Module ID block in each module? Mark for Review
(1) Points

It consists of four bar code labels used to identify the module configuration
and is located in the same area in all modules. (*)

It contains all logical addresses in a library.

It is non-essential but can sometimes be useful.


he Module ID block is only located in the Base Module of the library and has
1to 4 cartridges.

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

25. Which card is tied to the library serial number, contains flash
memory that stores the library configuration information, retains a list of
features and module upgrades, and provides library security? It also contains a
database of activation passwords and stores library user passwords. Mark for
Review
(1) Points

PUN

PUM

PKZ

PUK (*)

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

Page 5 of 8
=====================================================

Test: Oracle StorageTek SL3000 Installation Consultant Online Assessment

Review your answers, feedback, and question scores below. An asterisk (*) indicates
a correct answer.
This 40-question assessment test is the final on-line component of the Oracle
StorageTek SL3000 Installation Consultant guided learning path. This assessment
will allow you to test your knowledge level of the information learned from the
StorageTek SL3000 courses. Passing at >80% of this assessment makes you eligible to
become an Oracle Installation Consultant for this subject matter.
SL3000 Mod Library
Five SL3000 Modules
(Answer all questions in this section)

26. Which card acts as the Cap serial port interface used to
communicate with the library controller (HBC) and other CAP? Mark for Review
(1) Points

PUM
PUN

PUZ (*)

PUK

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

27. Which statement describes this configuration: A Base module with


eight drives, no operator panel or window. One DEM with eight drives and no
operator panel, window or CAP. Eight CEMs with cartridge slots only, dual TallBots
with two AEMs. Mark for Review
(1) Points

This configuration is not possible with that much storage capacity.

. (*)

This configuration provides the minimum storage capacity.

This configuration provides average storage capacity.

[Correct] Correct

28. If you convert a Cartridge Expansion Module to a Parking


Expansion Module, you will lose how many cartridge slots? Mark for Review
(1) Points

548

312

624

620 (*)

552
[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular
Library training for more information.

29. In SL3000 addressing, which is true of the DEM? Mark for


Review
(1) Points

DEM column numbers are positive because DEMS are always to the right of the
base in the firmware addresses.

DEM column numbers are negative because DEMS are always to the right of the
base in the firmware addresses.

38

DEM column numbers are negative because DEMS are always to the left of the
base in the firmware addresses. (*)

DEM column numbers are positive because DEMS are always to the left of the
base in the firmware addresses.

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

30. Which is the following describes the TallBot? Mark for Review
(1) Points

The TallBot is a FRU. (*)

Most parts on the TallBot can be replaced.

All parts on the TallBot can be replaced.

The TallBot is a CRU.

The TallBot is a CRU or FRU.

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

Page 6 of 8
==============================================

Test: Oracle StorageTek SL3000 Installation Consultant Online Assessment

Review your answers, feedback, and question scores below. An asterisk (*) indicates
a correct answer.
This 40-question assessment test is the final on-line component of the Oracle
StorageTek SL3000 Installation Consultant guided learning path. This assessment
will allow you to test your knowledge level of the information learned from the
StorageTek SL3000 courses. Passing at >80% of this assessment makes you eligible to
become an Oracle Installation Consultant for this subject matter.
SL3000 Mod Library
Five SL3000 Modules
(Answer all questions in this section)

31. What is the advantage of a 2N versus an N + 1 Power


Configuration? Mark for Review
(1) Points

It provides extra power to the rails and is therefore more efficient.

It provides AC and DC Power redundancy. (*)

It provides extra power to the DEM and is therefore more efficient

There is no advantage it is simply a customer preference.

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

32. Assume that a library has a Base, a DEM, and a CEM (located
beside the DEM) and the DEM has one drive bay, how many media slots will there be
on the back wall of the DEM? Mark for Review
(1) Points

195

234

198

180

216 (*)
[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular
Library training for more information.

33. What does the TallBot do if a cartridge is not fully retracted


into the hand shell? Mark for Review
(1) Points

Nothing, the TallBot can maneuver around any obstacle in the library.

It is deemed an unsafe move by the Reach Safe Sensor so the TallBot will not
move because the cartridge is likely to strike something in the library. (*)

An alarm sounds and the TallBot maneuvers around any obstacle in the library.

The TallBot doesnt do anything but the operator must reach in the CAP and
fix the problem.

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

34. Which card is the library controller? Mark for Review


(1) Points

PUN

HBB

PUK

HBCR (*)

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

35. Which circuit card in the SL3000 is the most difficult to remove
and replace? Mark for Review
(1) Points

PUF (*)

PUW
PUZ

PUK

PUN

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

Page 7 of 8
================================================

Test: Oracle StorageTek SL3000 Installation Consultant Online Assessment

Review your answers, feedback, and question scores below. An asterisk (*) indicates
a correct answer.
This 40-question assessment test is the final on-line component of the Oracle
StorageTek SL3000 Installation Consultant guided learning path. This assessment
will allow you to test your knowledge level of the information learned from the
StorageTek SL3000 courses. Passing at >80% of this assessment makes you eligible to
become an Oracle Installation Consultant for this subject matter.
SL3000 Mod Library
Five SL3000 Modules
(Answer all questions in this section)

36. If the TallBot hand gripper does not fully release a cartridge
when it is placed in a slot, what prevents the cartridge from being pulled back
out? Mark for Review
(1) Points

Proximity Sensors prevent cartridges from being pulled out.

There are no features that can prevent this occurrence cartridges always
get pulled out if this happens.

Cartridge retention features know if the grippers wont release and dont
allow the TallBot to enter cartridges into the slot.

Cartridge retention features that have small speed bumps that help prevent
a cartridge from being pulled out. (*)

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

37. In the HLI-PRC numbering system for tape drives, the only numbers
that are significant are those pertaining to the: Mark for Review
(1) Points

Drive and Column

LSM and Drive

LSM and Row

Panel and Column

Panel and Drive (*)

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

38. The SL3000 provides two 1-rack unit spaces in the Base and DEM
that can be used for: Mark for Review
(1) Points

The Service Delivery Platform (SDP)

Customer hubs

Optional Ethernet switches (*)

Routers

Any of the above devices

[Correct] Correct

39. What is the difference between N+1 and 2N power configuration in


the SL3000? Mark for Review
(1) Points

N+1 power uses one extra rail supply.

N+1 power uses two PDUs and one more than required DC supplies, while 2N uses
twice the number of DC supplies.
N+1 power is redundant for drives while 2N is redundant for all devices.

N+1 power uses one PDU and provides one more than required DC supply for
drives and rails, while 2N is fully redundant power at AC and DC level. (*)

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

40. If you were having a problem with a series of CAPs on either the
left or the right side of the Base, it would be prudent to start by checking the
LEDs on which two circuit cards? Mark for Review
(1) Points

PUN & HBC

PUF & PUN

PUW & PUZ (*)

HBS & PUZ

PUM & HBS

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.

Page 8 of 8
=======================================
6. To support the dual Tallbot feature, an SL3000 must have this minimum power.
Mark for Review
(1) Points

240V, 2N (*)

120V, 2N

240V, 2N+1

240V, N+1

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.
=======================================
Inside the Tallbot hand, the proximity sensor is comprised of two parts: a
transmitter and a receiver. The transmitter sends out a pulsed frequency signal and
the receiver detects this signal when it is reflected off of a surface. When a
signal detected by the receiver matches the signal sent by the transmitter, what
happens? Mark for Review
(1) Points

The reach safe sensor is triggered and the TallBot stops until an operator
can move the robot safely.

A valid surface is detected indicating tape cartridge presence. (*)

The Cartridge Present sensor sends an electronic signal to the host to eject
the media.

The TallBot goes to the CAP to eject a cartridge.

=======================================================
15. Assume the customer ordered a dual TallBot configuration and wants non-
disruptive replacement of the faulty TallBot. Which of the following should they
do? Mark for Review
(1) Points

Use the DEM as a parking garage so faulty TallBot replacements are non-
disruptive.

Use the AEM as a parking garage so faulty TallBot replacements are non-
disruptive. (*)

Convert a DEM to a PEM by changing the module ID at the host.

Convert two CEMs to PEMs by changing the module ID labels shipped with the
dual TallBot feature of the CEMs.

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.
16. The Base module ships with the following components installed: Mark for
Review
(1) Points

CAP

PDUs
DC power supplies (for a single TallBot and eight tape drives) (*)

Choices 1 & 3

Choices 1, 2, and 3

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.
================================================
18. When this module is placed to the left of the Base module, the left-most
column in the library is inaccessible to the TallBot but only if it is the last
column in the library and there is nothing to the left of it. Mark for Review
(1) Points

DEM

AEM

PEM

CEM (*)

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.
=========================================================
25. Which is the correct list of tape drives supported by the SL3000? Mark
for Review
(1) Points

LTO Gen 3, 4, 5; 9840 C & D, 9940C, T10K A, B, C, D

LTO Gen 4, 5, 6; 9840 C & D, 9940C, T10K A, B, C, D

LTO Gen 3, 4, 5, 6; 9840 C & D, SDLT600, T10K A, B, C, D

LTO Gen 3,4, 5, 6; 9840 C & D, T10K A, B, C, D (*)

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.
==========================================================
31. There is always one of these modules in the library and it is the only module
that can stand alone. It contains two DC power supplies, an Electronics Control
Module and a Drive Array with eight drives. Two additional arrays may be ordered
for this module. Mark for Review
(1) Points

AEM

BASE (*)

PEM

DEM

CEM

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.
===============================================
31. There is always one of these modules in the library and it is the only module
that can stand alone. It contains two DC power supplies, an Electronics Control
Module and a Drive Array with eight drives. Two additional arrays may be ordered
for this module. Mark for Review
(1) Points

AEM

BASE (*)

PEM

DEM

CEM

[Incorrect] Incorrect. Please refer to the appropriate SL3000 Modular


Library training for more information.
==============================================

Вам также может понравиться