Вы находитесь на странице: 1из 4

After Sales Service International

Servicing Information
Servicing Information no. 39/2002 LHG/TKD-KH/22.12.02

List of thermostat switching values

This Servicing Information supersedes Circular no. 16/99

Notes on the table

o Cold Off and On is measured with the control at the highest setting (as far as it will go
to the right).
o Warm Off and On is measured with the control at the lowest setting (as far as it will
go to the left).
o Signal above Cold On/Warm On: The alarm contact closes as soon as the
temperature at the sensor has risen above the set temperature by the corresponding
amount.
Example: If Warm On is -15C and Signal above Cold On/Warm On is 4C, the
alarm triggers at -11C.
o Defrost is the switch-on value for thermostats with a semi-automatic defrost function.

Important notes on checking the switching value

o Always use an accurate digital thermometer (min. 1C accuracy) to measure the


temperature.
o There must always be good thermal contact between the measuring sensor on your
thermometer and the immediate sensor point on the thermostat.
o When measuring the switch-off value, greater tolerances may occur as a result of the
thermal contact with your measuring sensor.
o Thermostats should always be checked with the control at the highest setting so that
the appliance is definitely in switching mode.

Replacement thermostats

Please note that replacement thermostats must always have the same switching values as
the original thermostat.

Page 1/4 39200200SI


Servicing Information no. 39/2002 LHG/TKD-KH/22.12.02

Ranco type Liebherr Capillary Cold Off Cold On Warm Off Warm On Signal above Defrost
part no. tube length CO/WO
Atea A11 0080 6151 002 2350 -25.0 1.5 +5.0 1.0 -10.0 2.0 +5.0 1.0 / /
K54-H1101-001 6151 083 1200 -34.0 2.2 -28.0 ref. -19.0 1.0 -15.0 1.0 4.0 1.5 /
K54-H1103-001 or 6151 084 1200 -34.0 2.0 / -24.0 1.0 -20.0 1.0 4.0 1.5 /
Atea: A04 PR 2047C
K54-H1102-001 6151 085 2500 -38.0 2.2 / -23.5 1.0 -18.0 1.0 4.5 1.5 /
K59-L1287-000 or 6151 086 900 -23.0 1.5 +3.5 1.0 -8.0 2.0 +3.5 1.0 / /
K59-H1300-001
K59-L2621-000 or 6151 087 900 -29.0 1.5 +5.0 1.1 -18.0 2.0 +5.0 1.1 / /
K59-L2800-001
K54-H1107-001 6151 088 900 -32.0 2.0 / -21.0 1.0 -16.0 1.0 4.0 2.0 /
K54-H1118-001 6151 089 1600 -36.0 2.2 / -20.0 1.0 -16.0 1.0 4.0 1.5 /
K54-H1119-001 6151 090 2500 -35.0 2.2 / -22.0 1.0 -16.0 1.0 4.5 1.5 /
K57-H5521-001 6151 091 900 -19.6 1.8 +4.0 1.8 -3.0 2.5 +13.5 2.5 / /
K59-L2622-000 or 6151 097 600 -25.5 1.5 +5.0 1.0 -10.5 2.0 +5.0 1.0 / /
K59-H2816-001
K50-P6072-001 or 6151 098 900 -28.0 2.5 -11.4 2.5 -14.0 1.5 -1.5 1.5 / /
K50-L6543-000 orK50-
L6537-000
K50-P6073-003 6151 099 2000 -14.0 1.8 +2.0 1.8 / +14.0 2.5 / /
K60-L2069-000 6151 100 900 -29.5 1.6 -13.1 / -5.0 2.5 / 5
K50-H2027-001 6151 101 1500 < -33.0 / -22.0 1.5 -18.0 1.5 / /
K60-L2068-000 or 6151 102 900 -25.0 2.5 -11.0 ref. -11.5 1.5 -1.0 1.5 / 5.8
K60-L2129-000
K50-H5656-001 6151 103 / -16 -11 / / / /
K50-H2026-001 6151 104 1200 < -33.0 / -21.0 1.5 -16.0 1.5 / /
K50-H2029-001 6151 105 1200 -1.0 1.5 +4.0 1.5 / +10.0 2.0 / /
K50-H2028-001 6151 106 1200 -31.5 1.5 -27.0 1.5 -10.5 ref. -8.0 2.0 / /
K54-H1430-001 6151 107 2000 -38.0 2.2 / -23.5 1.0 -18.0 1.0 4.5 1.5 /
K50-H2036-001 6151 110 2000 -2.0 1.0 +4.0 1.0 / +19.0 2.0 / /
ETR16(4) Koch 6151 111 / / / 24 22 / /
K61-H3510-001 6151 112 920 -0.8 1.0 Diff. 3.0 +7.0 ref. +9.3 2.0 / /
1.0
K54-H1439-001 6151 113 1600 -36.0 2.2 / -24.0 1.0 -19.5 1.0 8.5 2.0 /
K61-H3511-001 6151 114 / -1.6 D5 7 ref.. 11.6 / /
K54-H1447-001 6151 115 900 -28 -11 -14 -1.5 8.5 /
K52-L2512-000 6151 116 / 1 5 7 5 / /
K57-H5528-001 or 6151 117 900 -28.0 2.5 -11.0 2.5 -14.0 1.5 -1.5 1.5 / /
K57-L5841-000 or
Atea: A11 PR 2047B
K56-H1029-001 6151 118 1200 -38.0 2.2 / -22.0 1.0 -18.0 1.0 4.0 1.5 /
K57-H5527-001 or 6151 119 900 -19.5 1.0 +2.0 1.0 -9.5 2.0 +8.0 2.0 / /
K57-L5840-000
K54-L7515-000 6151 120 2320 -32 / -19 -14.5 C-2.5 /
K54-L7517-000 6151 121 1600 -34 / -19 -14.5 C-2.5 /
K52-L1541-000 6151 122 1200/ 700 1 3 12 7.5 / /
K59-H2841-001 6151 124 900 -29.0 1.5 +5.0 1.1 -21.0 2.5 +5.0 1.1 / /
K59-L1288-000 or 6151 125 600 -23.0 1.5 +5.5 1.0 -10.0 2.0 +5.5 1.0 / /
K59-H1347-001
K54-P1196-000 6151 126 1200 -39.0 2.0 / -29.0 1.0 -20.0 1.0 4.0 1.5 /
K57-P5700-000 6151 129 / / / / / / /
K59-L2571-000 or 6151 132 900 -27.0 1.5 +5.0 1.1 -10.0 2.0 +5.0 1.1 / /
K59-L2629-000 or
Atea: A13 PR 2047A
K54-H1118-002 6151 134 1600 -36.0 2.2 / -20.0 1.0 -16.0 1.0 4.5 1.5 /
K54-H1119-003 6151 136 2500 -35.0 2.2 / -22.0 1.0 -16.0 1.0 4.5 1.5 /
K54-P1224-000 6151 140 900 -35.0 2.2 / -22.0 1.0 -16.0 1.0 4.5 1.5 /

Seite 2/4
Servicing Information no. 39/2002 LHG/TKD-KH/22.12.02

Ranco type Liebherr Capillary Cold Off Cold On Warm Off Warm On Signal above Defrost
part no. tube length CO/WO
K59-P3121-000 6151 142 900 -29.0 1.5 +7.5 1.1 -21.5 2.5 +7.5 1.1 / /
K57-L5816-000 6151 144 530 -19.5 1.0 +2.0 1.0 -9.0 2.0 +8.0 2.0 / /
K56-L1870-000 6151 146 1750 -36.0 2.2 / -19.0 1.0 -15.0 1.0 4.0 1.5 /
K56-L1871-000 6151 148 2650 -35.0 2.2 / -22.0 1.0 -16.0 1.0 4.5 1.5 /
K57-L5818-000 or 6151 150 2250 -19.5 1.0 +2.0 1.0 -9.0 2.0 +8.0 2.0 / /
Atea: A11 0080
K59-L1255-000 6151 152 2250 -23.0 1.5 +3.5 1.0 -8.0 2.0 +3.5 1.0 / /
K59-L1256-000 or 6151 154 2250 -25.0 1.5 +5.5 1.0 -10.0 2.0 +5.5 1.0 / /
Atea: A13 0553
K57-L5829-000 6151 158 900 -13.0 1.0 +3.0 1.0 -4.0 2.0 +9.5 2.0 / /
K57-L5835-000 6151 160 1600 -19.5 1.0 +2.0 1.0 -9.0 2.0 +8.0 2.0 / /
K52-L1566-000 6151 162 750/700 +1.0 1.0 +3.0 1.0 +12.0 2.0 +7.5 2.0 / /
K59-L2619-000 6151 164 900 / / / / / /
K54-L1991-000 6151 168 1200 -35.0 2.0 / -25.0 1.0 -16.0 1.0 4.0 1.5 /
K59-L1962-000 6151 170 1700 -32.5 1.5 +4.8 1.0 -18.4 2.0 +4.8 1.0 / /
K57-L5861-000 6151 172 1800 -13.5 1.0 +2.0 1.0 -4.5 1.0 +8.0 2.0 / /
Atea: A11 0081
K59-L1995-000 6151 174 1500 -25.0 1.5 +5.5 1.0 -10.0 2.0 +5.5 1.0 / /
K59-L2664-000 6151 176 450 -32.5 1.5 +4.8 1.1 -23.0 2.0 +4.8 1.1 / /
K59-L2665-000 6151 178 450 -32.5 1.5 +4.0 1.1 -18.4 2.0 +4.0 1.1 / /
K57-L5883-000 6151 180 / -25.0 2.5 -11.0 ref. -11.8 1.5 -1.0 1.5 / /
K57-L5882-000 6151 182 / -19.5 1.0 +2.0 1.0 -9.5 2.0 +8.0 2.0 / /
K57-L5887-000 6151 184 800 -28.0 2.5 -11.0 2.5 -14.0 1.5 -1.5 1.5 / /
K59-L2677-000 6151 186 600 -29.0 1.5 +5.0 1.1 -10.5 2.5 +5.0 1.1 / /
K59-L2684-000 6151 188 900 -29.0 1.5 +5.0 1.0 -10.5 2.0 +5.0 1.0 / /
K57-L5537-000 6151 190 900 -24.0 1.0 +2.0 1.0 -13.5 2.0 +8 20 / /
Atea: A13 PR 2185 6113192 450 -25.0 1.5 +3.5 1.0 -12.0 1.2 +3.5 1.0 / /
Atea: A11 0081 6113194 450 -19.5 1.0 +2.0 1.0 -12.0 1.2 +8.0 2.0 / /
K59-L2118-000 6151196 900 -26.0 1.5 +5.0 1.0 -5.0 2.0 +5.0 1.0 / /
K59-L2696-000 6151 799 630 -25.5 1.5 +5.0 1.1 - 10.5 2.0 +5.0 1.0 / /
K50-H2041-001 6151 900 1200 -9.0 1.0 -2.0 1.0 / +16.0 2.5 / /
K50-H2042-001 6151 901 1200 -36.0 2.0 / -21.0 1.0 -12.0 1.0 / /
K50-H2051-001 6151 904 2100 -5.5 1.0 -2.0 1.0 / +17.0 2.0 / /
K50-H2052-001 6151 905 2100 -40.0 2.5 / -16.5 1.0 -12.0 1.0 / /
K50-H2053-002 6151 907 2000 +6.0 2.0 / +19.0 1.0 Diff. max. / /
2.5
KC 250 6151 908 / / / 19 Diff. max. / /
2.5
K50-H2058-001 6151 909 2500 -35.0 2.0 -26.5 ref. -14.0 1.0 -8 / /
K50-H2065-001 6151 910 / -3 -6.5 ref.. 11 -14 / /
K54-H6200-001 6151 911 1800 -14.0 1.8 +2.0 1.8 / +14.0 2.5 4.0 2.0 /
K59-H1348-001 6151 913 / -26 6.5 1 -10 6.5 / /
K57-P5701-001 6151 915 800 -16.5 1.5 +6.0 1.5 -4.5 ref. +13.0 2.5 / /
K59-L2691-000 6151 939 700 -22.0 1.5 +5.0 1.1 - 10.5 2.0 +5.0 1.0 / /
K57-L5540-000 6151 941 750 -23.2 1.0 +1.8 1.0 -13.0 2.0 +8.4 2.0 / /
K57-L2848-000 6151 943 2000 -2.8 1.0 +4.5 1.0 +11.9 ref.. +17.0 2.0 / /
K59-L2688-000 6151 949 700 -32.5 1.5 +4.8 1.1 - 23.9 2.0 +4.8 1.1 / /
K59-L2686-000 6151 951 700 -30.0 1.5 +4.8 1.1 - 18.4 2.0 +4.8 1.0 / /
K59-L2685-000 6151 953 700 -25.5 1.5 +5.0 1.1 - 10.5 2.0 +5.0 1.0 / /
K57-L5843-000 6151 957 1700 -33.0 2.5 / -15.5 1.0 -10.0 1.0 / /
K59-L2655-000 6151 959 600 -19.0 1.5 +5.0 1.0 -10.02.0 +5.0 1.0 / /
K59-L2655-000 6151 961 600 -19.0 1.5 +5.0 1.0 -9 +5.0 1.0

Seite 3/4
Servicing Information no. 39/2002 LHG/TKD-KH/22.12.02

Ranco type Liebherr Capillary Cold Off Cold On Warm Off Warm On Signal above Defrost
part no. tube length CO/WO
K59-L2656-000 6151 963 700 -27.5 1.5 +5.0 1.0 -10.5 2.5 +5.0 1.0 / /
K54-L1998-000 6151 965 900 -32.0 2.0 / -21.0 1.0 -16.0 1.0 4.0 2.0 /
K57-L2838-000 6151 967 1700 -4.0 1.0 +4.0 1.0 / +16.0 2.0 / /
K57-L5853-000 6151 969 700 -36.0 2.0 / -14.7 1.0 -4.8 1.0 / /
K56-L1895-000 6151 971 1750 -36.0 2.2 / -19.0 1.0 -15.0 1.0 4.0 1.5 /
K57-L2835-000 6151 973 2000 -4.0 1.0 +2.0 1.0 +13.0 ref.. +17.0 2.0 / /
K57-L5845-000 6151 975 1100 -15.0 1.0 +2.5 1.0 -6.0 2.0 +8.2 2.0 / /
K50-L3280-000 6151 981 2000 -4.5 1.0 +1.5 1.0 / +19.0 2.0 / /
K56-L1885-000 6151 983 1750 -37.0 2.2 / -20.0 1.0 -14.0 1.0 4.0 1.5 /
K50-L6538-000 6151 985 700 -37.0 2.0 / -15.0 1.0 -5.0 1.0 / /
K59-L2610-000 6151 987 700 -29.5 1.5 +4.8 1.1 -18.4 2.0 +4.8 1.1 / /
K52-L1564-000 6151 989 1200 -1.5 1.0 +3.0 1.0 +12.0 2.0 +7.5 2.0 / /
K50-L3263-000 6151 991 1200/1500 -28.0 1.0 -21.0 1.0 -19.0 2.0 -12.0 2.0 / /
K50-H2053-001 6151 993 2000 +6.0 2.0 / +19.0 1.0 Diff. max. / /
2.5
K50-P6073-001 6151 995 2000 -14.0 1.8 +2.0 1.8 / +14.0 2.5 / /
K50-L3252-000 6151 997 1700 -4.0 1.0 +4.0 1.0 / +16.0 2.0 / /
Pre-set, cannot be 9801 701 2000 / / -13.5 2.3 / /
adjusted
Pre-set, cannot be 9801 703 2000 / / -3.4 2.5 / /
adjusted
Pre-set, cannot be 9801 699 2000 / / -13.5 2.3 / /
adjusted
Pre-set, cannot be 9801 931 2000 / / -1 4.7 / /
adjusted

Seite 4/4

Вам также может понравиться