Вы находитесь на странице: 1из 36

Vickers

Pressure Relief

Sequence, Unloading, Back Pressure,


Counterbalance, and Reducing Valves
R, UR, and X 03/06/10/12 Series
Pressures to 210 bar (3000 psi) Flows to 284 l/min (75 USgpm)

Released 7/94 686


Introduction

R Series Sequence, overrunning. A remote P version is also system, the valve cuts out automatically
available for use in braking circuits. when the accumulator pressure reaches
Unloading, Back adjusted maximum. At cut-in pressure
Pressure, and Counterbalance (approximately 85% of adjusted
maximum), the valve directs delivery to
Counterbalance Valves Vickers Hydrocushion type
the accumulator and the hydraulic
counterbalance valves are used for the
There are several configurations of this system automatically.
control of unloading and sequence of oil
basic valve which can be made by
flow in hydraulic systems, induced by
changing cover positions. The following In a double pump system, the valve
pressure rise either directly or by remote
outlines each type of function. automatically sequences the pumps to
means. They are available in the
following types: counterbalance valve, deliver a large volume of oil at low
Sequence and Unloading pressure and a small volume of oil at
Type 1internally operated;
Vickers Hydrocushion type pressure counterbalance valve, Type 4remotely high pressure.
control valves are used for the control of controlled. These valves are usually
unloading and sequence of oil flow in applied in a system to keep a vertical Models designated URT have threaded
hydraulic systems, induced by a load from falling. All models provide free ports and require a separate check
pressure rise, directly or by remote reverse flow by means of an integral valve to function as an unloading circuit.
means. They are available in the check valve. (Refer to valves without
following types: sequence valve, Type integral check when reverse free flow is X Series Pressure
2directly operated; sequence valve,
Type 3remotely controlled; unloading
not required.) Reducing Valves
valve, Type 4remotely controlled. These pressure reducing valves
UR Series Unloading maintain a reduced level of outlet
Back Pressure Relief Valves with pressure regardless of variations in inlet
pressure above the pressure setting of
Back pressure valves are designated as Integral Check Module the valve. The valves also allow reverse
Type 1internally operated. They are An integral check valve prevents return free flow at pressures below the setting
used to provide back pressure on the flow from the accumulator through the of the valve.
hydraulic actuator to prevent unloading valve. In an accumulator

Table of Contents
Series R(C)*-03/06/10/12 Sequence, Unloading, Back Pressure, and Counterbalance Valves . . . . . . . . . . . . . . . . . . . . . . . . . 3

Series URT*-06/10 Unloading Relief Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Series URG*-06/10 Unloading Relief Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Series XSL/XTL-03 Pressure Reducing Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Series XGL-03 Pressure Reducing Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Series X(C)*-03/06/10 Pressure Reducing Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

2
Series R(C)*-03/06/10/12 Sequence, Unloading,
Back Pressure, and Counterbalance Valves

Ratings
Rated Pressure (Maximum)* 210 bar (3000 psi)
Rated Capacity (Maximum)**
R*-03 45 l/min (12 USgpm)
R*-06 114 l/min (30 USgpm)
R*-10 and R*-12 284 l/min (75 USgpm)
* 140 bar (2000 psi) permitted on the full piston area at the bottom cover (P connection),
and at the top cover (spring chamber). See tank drain information on page 4.
** Rated capacities are based on using fluid with a specific gravity of 0.865 and a viscosity of
20 cSt (100 SUS).

Model Code

1 2 3 4 5 6 7 8 9

1 Special seals 5 Valve size 7 Remote control connection


F3 For mineral oil and fire resistant 03 3/
8 pipe or 0.7500-16 UNF-2B P Auxiliary remote pressure
fluids. Mounting face seals of straight thread (0.500 tubing) control connection (not
RCG model are standard 06 3/4 pipe or 1.0625-12 UN-2B available with X, Y, or Z
Buna-N unless specified as F3. straight thread (0.750 tubing) pressure ranges or in
Blank Omit for standard, R(C)S, and 10 11/4 pipe or 1.6250-12 UN-2B R(C)G-03 models)
R(C)T models. straight thread (1.250 tubing) Blank Omit if not required
12 11/2 pipe or 1.8750-12 UN-2B
straight thread (1.500 tubing)
2 Valve type (not available in R(C)G models) 8 Valve application type
R Pressure control valve 1 Internal drain directly operated
2 External drain directly operated
6 Pressure range
3 External drain remotely operated
3 Integral check valve X 0,7 to 2,1 bar (10 to 30 psi) 4 Internal drain remotely operated
C Reverse free flow check Y 2,1 to 4,1 bar (30 to 60 psi)
Z 4,1 to 8,5 bar (60 to 125 psi)
A 5,2 to 17,2 bar (80 to 250 psi) 9 Design number
4 Connections B 8,5 to 35 bar (125 to 500 psi) Subject to change. Installation dimensions
D 17,2 to 70 bar (250 to 1000 psi) same for designs 30 through 39.
G Manifold or subplate mounting
F 35 to 140 bar (475 to 2000 psi)
S SAE straight thread
T NPTF thread*
*Not recommended

3
Series R(C)*-03/06/10/12 Sequence, Unloading,
Back Pressure, and Counterbalance Valves

General Data Auxiliary Remote Pressure When the load is being accelerated,
pressure is maximum at the motor inlet
Vickers hydrocushion type pressure Control P and under the large area of the brake
control valves are used to control the All models (except R(C)G -03 and those valve spool, holding it in the full open
sequencing, unloading, back pressure, with an X, Y, or Z pressure position and permitting free flow from
and counterbalancing of oil flow in adjustment range in their model code) the exhaust port of the motor.
hydraulic systems. Control is initiated by are available with an auxiliary remote
a pressure rise which can be sensed control connection. Required pressure When the motor gets up to speed, load
either internally (directly) or remotely. at the auxiliary connection is 1/16 of the pressure still holds the brake valve open
Models are available with or without normally required control pressure for unless the load tries to run away. If this
integral reverse free flow checks. the F pressure range and 1/8 of the happens, the pressure falls off at the motor
normally required control pressure for inlet and in the remote control pressure
Pressure Adjustment the A, B, and D pressure ranges. passage. The spring force tends to close
Pressure ranges (see model code (This applies to -22 design and up.) the valve, thus increasing the back
page 3) are maximum controllable, and pressure on the motor, tending to brake it.
each model selected should be well Brake Valve
within the range given to afford fine A brake valve is used in the exhaust line When the directional valve is shifted to
increments of adjustment. Pressure of a hydraulic motor to: 1) prevent neutral, inertia may cause the motor to
setting must be at least 17 bar (250 psi) overspeeding when an overrunning load continue rotating against the brake valve.
lower than the system relief valve setting. is applied to the motor shaft; and 2) Until the motor stops turning, it will
prevent excessive pressure buildup operate as a pump, drawing fluid from
Pressure can be adjusted by loosening when decelerating or stopping a load. the motor outlet through the directional
a jam nut and turning an adjustment valve and circulating it back to the motor
screw. Turning clockwise increases When the RC valve is used as a brake inlet. Motor leakage oil will be made up
pressure, and turning counterclockwise valve, it has a solid spool (no drain hole by drawing oil into the loop through the
decreases pressure. through the center), and there is a tank port of the valve. At this time,
remote operating pressure connection in pressure at the motor outlet tending to
Installation Data the bottom cover directly under the spool. bring it to a stop will be whatever is
Mounting This connection is teed into the supply required under the small piston to
Because all R(C)T and R(C)S models line to the motor. The internal control overcome the brake valve setting.
have optional pressure inlets connected connection is also used under the small
by a through passage, the valves may be piston and senses pressure from the
mounted in-line. The valves may also be primary port of the RC valve, which is
teed to a line by using either one of the connected to the motor exhaust port.
pressure inlets and plugging the other.

The remote pressure control connection


Typical Application: Brake Valve
on type 3 and 4 valves must be
connected to an external pilot pressure a A B b
source sufficient to operate the valve at
the desired pressure setting and flow P T
conditions.

Tank Drain
The discharge outlet of valve types 1 and
4 must be piped to tank at atmospheric
pressure. The drain connection on types
2 and 3 must be piped directly to tank at
atmospheric pressure. Any pressure at
the drain port must be added to the
pressure setting of the valve.
DR

4
Series R(C)*-03/06/10/12 Sequence, Unloading,
Back Pressure, and Counterbalance Valves

Pressure Drop
The following table lists approximate
Maximum Total Leakage vs. Pressure Drop
pressure drops (P) when passing flow The following graph shows the relationship between maximum total leakage and
of fluid with a specific gravity of 0.865 pressure drop for fluid with a specific gravity of 0.865 and a viscosity of 20 cSt
and a viscosity of 20 cSt (100 SUS). (100 SUS). Leakage is approximately proportional to viscosity in centistokes.

Reverse Free Flow INLET TO OUTLET PRESSURE DROP psi


Pressure Drop 0 500 1000 1500 2000
1200
Flow P 70
Valve l/min (USgpm) bar (psi)
RC*-03 45 (12) 5,5 (80)
1000
60
RC*-06 114 (30) 3,4 (50) R**-06
RC*-10 189 (50) 2,8 (40)

TOTAL OUTLET LEAKAGE in3 /min


TOTAL OUTLET LEAKAGE cc/min 50
RC*-12 189 (50) 2,4 (35) 800

R**-10/12
For any other flow rate (Q1), the
40
approximate pressure drop (P1) can be 600
calculated using the following formula:
P1 = P (Q1 / Q2)2. 30
R**-03
For any other viscosity of fluid, the 400
pressure drop will change according to 20
the following table:
200
Viscosity Approximate 10
cSt (SUS) % of P
14 (75) 93
0 0
0 25 50 75 100 125 150
27 (150) 111
INLET TO OUTLET PRESSURE DROP bar
38 (200) 119
46 (250) 126
56 (300) 132
64 (350) 137
74 (400) 141

For any other specific gravity (G1), the


approximate pressure drop (P1) can be
calculated using the following formula:
P1 = P (G1 / G).

The specific gravity of fluid may be


obtained from its producer. The value is
higher for fire-resistant fluids than for oil.

5
Series R(C)*-03/06/10/12 Sequence, Unloading,
Back Pressure, and Counterbalance Valves

Installation Dimensions
Millimeters (inches)
Subplate or Manifold Mounted Models
RG- * * - * * -30 Without Check

6,35 (0.25)*

NOTES
Sequence valve shown (remotely
controlled, external drain, type 3).
A sq.
* See mounting subplates for locating
dimensions.
**.4375-20 UNF-2B straight thread for
0.250
O.D. tubing.
B Pressure
C adjustme
nt control

Secondary
outlet port
10,3 (0.406) thru
15,1 (0.594)
Secondary counterbore
pressure gage Drain port* H number of holes
6,35
connection** (see Tank for mounting*
(0.25)*
E Drain,
Fully page 2)
extended Rest pin*

Primary
pressure gage Remote pressure
connection** control port*
F
G
Pressure inlet port

D
Auxiliary remote
pressure control port
(P models only)*

Model A B C D E F G H J NFPA Interface


57,2 36,6 68,1 55,9 178,6 47,5 30,0 90,4
R(C)G-03-**-30 4 P03
(2.25) (1.44) (2.68) (2.20) (7.03) (1.87) (1.18) (3.56)
71,4 41,1 79,2 73,7 201,4 67,6 45,2 98,6
R(C)G-06-**-30 4 P06
(2.81) (1.62) (3.12) (2.90) (7.93) (2.66) (1.78) (3.88)
95,2 50,8 100,1 90,2 282,2 71,6 44,4 130,0
R(C)G-10-**-30 6 P10
(3.75) (2.00) (3.94) (3.55) (11.11) (2.82) (1.75) (5.12)

6
Series R(C)*-03/06/10/12 Sequence, Unloading,
Back Pressure, and Counterbalance Valves

RCG- * * - * * -30 With Check

NOTE
Sequence valve shown (remotely
controlled, external drain, type 3).

7
Series R(C)*-03/06/10/12 Sequence, Unloading,
Back Pressure, and Counterbalance Valves

Threaded Port Models


RS/T- * * - * * -30 Without Check

NOTES
Sequence valve shown (directly operated,
F external drain, type 2).
V All external connections are straight thread
D wrench flats
sq. E H (3 places) (except inlet and outlet ports of R(C)T
models).
G
*.4375-20 UNF-2B straight thread for 0.250
O.D. tubing.

J **.5627-18 UNF-2B thread


K Pressure
adjustment
control
System
connections
Secondar
S or T thd.
y outlet
(3 places)

C
L
A Secondary
Fully pressure
extended N gage
conneciton*

R Primary
M
B pressure
System gage
connections conneciton*
S or T thd.
(3 places) Auxiliary remote
pressure control
Remote pressure connection (P
control connection** models only)**

Model A B C D E F G H J K
178,6 53,3 96,8 59,4 35,1 29,7 39,6 70,9 35,1 69,8
R(C)S/T-03-**-30
(7.03) (2.12) (3.81) (2.34) (1.38) (1.17) (1.56) (2.79) (1.38) (2.75)
201,4 75,4 97,8 74,7 47,8 37,3 50,8 88,1 47,8 95,2
R(C)S/T-06-**-30
(7.93) (2.97) (3.85) (2.94) (1.88) (1.47) (2.00) (3.47) (1.88) (3.75)
282,2 84,1 154,2 98,6 82,6 49,3 68,3 117,6 53,8 108,0
R(C)S/T-10-**-30
(11.11) (3.31) (6.07) (3.88) (3.25) (1.94) (2.69) (4.63) (2.12) (4.25)
282,2 84,1 154,2 98,6 82,6 49,3 68,3 117,6 53,8 108,0
R(C)S/T-12-**-30
(11.11) (3.31) (6.07) (3.88) (3.25) (1.94) (2.69) (4.63) (2.12) (4.25)

8
Series R(C)*-03/06/10/12 Sequence, Unloading,
Back Pressure, and Counterbalance Valves

RCS/T- * * - * * -30 With Check

NOTE
Sequence valve shown (remotely
controlled, external drain, type 3).

Model L M N P R S Str. Thd. T Str. Thd. V


RS and RCS RT and RCT
Models Models
58,7 42,9 23,1 93,7 38,9 35,1
R(C)S/T-03-**-30 .750016 UNF2B 3/8
(2.31) (1.69) (0.91) (3.69) (1.53) (1.38)
79,5 57,2 27,2 108,0 46,7 3/ 50,8
R(C)S/T-06-**-30 1.062512 UN2B 4
(3.13) (2.25) (1.07) (4.25) (1.84) (2.00)
80,3 70,6 28,7 147,6 57,2 86,4
R(C)S/T-10-**-30 1.625012 UN2B 11/4
(3.16) (2.78) (1.13) (5.81) (2.25) (3.40)
80,3 70,6 28,7 147,6 57,2 86,4
R(C)S/T-12-**-30 1.875012 UN2B 11/2
(3.16) (2.78) (1.13) (5.81) (2.25) (3.40)
 For P models only. See model code.
 Not recommended.

9
Series R(C)*-03/06/10/12 Sequence, Unloading,
Back Pressure, and Counterbalance Valves
Mounting Subplates P
When a subplate is not used, N
EE
a machined pad (as DD
indicated by shaded area) K straight thd. (from
must be provided for reverse side) 2 holes
mounting. The pad must be M
flat within 0,013 mm (0.0005 P subplates for P model
L
in) and smooth within 1,6 mm valves only. Straight thread
(63 microinch). Mounting port subplates are not
bolts provided by the available with P port option.
.37516 UNC2B
customer should be SAE thd. CC number U
grade 7 or better. T 10,31 (0.406) thru
of mounting holes 15,09 (0.594) counterbore
PP BB
Z AA 9,65 (0.38) deep 4 holes
RR
LL

GG SS
JJ
KK U
MM X U
V HH Y R

W rad.
7,14 (0.281) for rest
pin 7,87 (0.31) deep FF 2 ports Drain port for RG
TT
4,76 (0.1875) drill thru and
.562518 UNF2B thd. S rad. 2 places RCG-**-*2/3-30
(from reverse side) models

Model K Tube L M N P R S T U V
O.D.
RXGM-03S-(P)-20 .750016 1 25,4 19,0 63,5 127,0 76,2 23,9 43,7 87,4 63,5
/2
UNF2B (1.00) (0.75) (2.50) (5.00) (3.00) (0.94) (1.72) (3.44) (2.50)
RXGM-06SX-(P)-20 1.31251 31,8 19,0 73,2 146,0 117,3 39,6 50,8 101,6 82,6
1
2 UN2B (1.25) (0.75) (2.88) (5.75) (4.62) (1.56) (2.00) (4.00) (3.25)
RXGM-10S-(P)-30 1.62501 1 47,8 22,4 79,2 158,8 146,0 47,8 58,7 117,3 104,6
1 /4
2 UN2B (1.88) (0.88) (3.12) (6.25) (5.75) (1.88) (2.31) (4.62) (4.12)

Model W X 0,13 Z AA BB CC DD 0,013 FF GG


Y (0.005) EE(0.005)
10,4 35,8 42,87 25,4 33,3 66,5 53,1 106,37 14,2 21,3
RXGM-03S-(P)-20 4
(0.41) (1.41) (1.688) (1.00) (1.31) (2.62) (2.09) (4.188) (0.56) (0.84)
10,2 49,3 60,32 33,3 39,6 79,2 62,0 123,82 23,1 20,6
RXGM-06SX-(P)-20 4
(0.44) (1.94) (2.375) (1.31) (1.56) (3.12) (2.44) (4.875) (0.91) (0.81)
10,4 67,6 84,12 44,4 48,5 96,8 69,1 138,12 28,4 24,6
RXGM-10S-(P)-30 6
(0.41) (2.66) (3.312) (1.75) (1.91) (3.81) (2.72) (5.438) (1.12) (0.97)

Model HH JJ KK LL MM PP RR SS TT UU NFPA


Interface
28,4 31,8 4,8 38,1 6,4 10,4 25,4 21,3
RXGM-03S-(P)-20 P03
(1.12) (1.25) (0.19) (1.50) (0.25) (0.41) (1.00) (0.84)
38,1 44,4 6,4 53,8 17,5 11,2 16,8 33,3 39,6
RXGM-06SX-(P)-20 P06
(1.50) (1.75) (0.25) (2.12) (0.69) (0.44) (0.66) (1.31) (1.56)
50,8 42,2 62,7 7,9 76,2 20,6 10,4 24,6 44,4 59,4
RXGM-10S-(P)-30 P10
(2.00) (1.66) (2.47) (0.31) (3.00) (0.81) (0.41) (0.97) (1.75) (2.34)
 RXGM-03S/06SX require 4 valve mounting screws. RXGM-10S requires 6 valve mounting screws.

10
Series R(C)*-03/06/10/12 Sequence, Unloading,
Back Pressure, and Counterbalance Valves

Graphical Symbols
Type P Back Pressure and Counterbalance Valves
Auxiliary remote control operated with P connection
Internal drain (model *P1 shown)

R(C)G Valves R(C)S/T Valves

Back Pressure (RG) Back Pressure (RS/T)

Plug in
place
P Conn P Conn

Counterbalance (RCG) Counterbalance (RCS/T)

Auxiliary remote Auxiliary remote


P Conn pressure control P Conn pressure control
port for P port for P
models only models only

Type 1 Back Pressure and Counterbalance Valves


Internally operated Internal drain

R(C)G Valves R(C)S/T Valves

Back Pressure (RG) Back Pressure (RS/T)

Plug in
place

Counterbalance (RCG) Counterbalance (RCS/T)

Plug in
place

11
Series R(C)*-03/06/10/12 Sequence, Unloading,
Back Pressure, and Counterbalance Valves

Type 2 Sequence Valves


Internally operated External drain

R(C)G Valves R(C)S/T Valves

(RG) (RS/T)

Drain Drain
port connection

(RCG) (RCS/T)

Plug in
place

Type 3 Sequence Valves


Remote control operated External drain

R(C)G Valves R(C)S/T Valves

(RG) (RS/T)

Drain Drain
port connection

(RCG) (RCS/T)

Remote Remote
pressure pressure
control port control
connection

12
Series R(C)*-03/06/10/12 Sequence, Unloading,
Back Pressure, and Counterbalance Valves

Type 4 Unloading and Counterbalance Valves


Remote control operated Internal drain

R(C)G Valves R(C)S/T Valves

Unloading (RG) Unloading (RS/T)

Plug in
place

Counterbalance (RCG) Counterbalance (RCS/T)

Remote Remote
pressure pressure
control port control
connection

13
Series URT*-06/10 Unloading Relief Valves

Ratings
Rated Pressure (Maximum) 210 bar (3000 psi)
Rated Capacity (Maximum)
URT*-06 76 l/min (20 USgpm)
URT*-10 189 l/min (50 USgpm)

Model Code

1 2 3 4 5 6 7 8 9

1 Special seals 4 Connections 7 Cutout pressure range


F3 For mineral oil and fire resistant T NPTF thread* B 24 to 70 bar (350 to 1000 psi)
fluids C 35 to 140 bar (500 to 2000 psi)
*Not recommended
Blank Omit for standard models F 103 to 210 bar (1500 to 3000 psi)

5 Drain
2 Valve function 1 Externally drained
8 High vent spring
U Unloading valve 2 Internally drained V Optional high vent spring
installed
Blank Omit if not required
3 Valve type 6 Valve size
R Pressure control valve 06 3/4 pipe
10 11/4 pipe
9 Design number
Subject to change. Installation dimensions
same for designs 10 through 19.

General Data hydraulic system. The valve may also Pressure Adjustment
be used with a double pump to deliver a
These valves are used in oil hydraulic Pressure can be adjusted by loosening
large volume of oil to the system at low
circuits where a pressure regulator is a jam nut and turning an adjustment
pressure and a small volume at high
required to automatically unload the screw. Turning clockwise increases
pressure, serving the same function as
pump by diverting the pump delivery to pressure, and turning counterclockwise
an unloading valve. A separate right
the reservoir, at low pressure, when the decreases pressure.
angle check valve, C2-815 (3/4) or
accumulator pressure reaches the
C2-825 (11/4) must be provided to
desired maximum (or cut out)
maintain accumulator hydraulic charge
pressure. When the accumulator
or unloading of high volume pump and
pressure drops to the cut in pressure
prevent back flow when pump is
(approximately 85% of the desired
unloaded.
maximum), the valve directs pump
delivery to the accumulator and

14
Series URT*-06/10 Unloading Relief Valves

Installation Data CAUTION Connections


Tank Drain For series URT1 only, the drain must Pressure inlet and outlet connections
Back pressure at the tank discharge port be connected to tank through a are connected by a through passage
of the URT1 series (externally drained) surge free line so there will be no which permits use of either connection
valves will not effect the operation at up back pressure at this drain. Failure as an inlet.
to 85% of the inlet pressure. Back to connect drain can result in infinite
pressure at the tank discharge port of system pressures and machine
the URT2 series (internally drained) damage. Series URT2 has internal
valves must not exceed 5% of the inlet drain and this port is not used.
pressure.

Approximate Minimum Venting Pressures bar (psi) at


Various Percentages of Maximum Rated Capacity
Model 25% 50% 75% 100%
URT*-06-*-10 0,7 (10) 0,8 (11) 1,0 (15) 1,6 (23)
URT*-06-*V-10 3,9 (56) 3,9 (57) 4,1 (59) 4,3 (63)
URT*-10-*-10 0,4 (6) 0,7 (10) 1,6 (23) 2,7 (39)
URT*-10-*V-10 3,6 (52) 3,7 (54) 3,9 (57) 4,1 (59)

Typical Applications

Double Pump Circuit Accumulator Circuit

To hydraulic
system
Accumulator
Unloading For best results, check
relief valve valve should be To
located in close hydraulic
proximity to URT* Unloading system
Discharge valve.
to tank relief valve Delivery
from pump
Drain For best results,
Discharg check valve and
(optional)
Pump high e to tank accumulator should
external Pump low
drain pressure, pressure, low be located in close
volume delivery Drain (optional) proximity to URT*
high volume
external drain valve.
delivery

15
Series URT*-06/10 Unloading Relief Valves

Installation Dimensions
Millimeters (inches)
URT1 and URT2 with Threaded Connections
for 3/4 and 11/4 Piping
Pressure
adjustment
control
Pilot pressure connection
for unloading pump 1/4
NPTF thd.

1/ NPTF thd. (see 88,9 (3.50) fully


4 D extended
CAUTION, page 15)

System
connections
P - NPTF
F thd. 3 places
G
A
Pressure line Pressure line
Pressure gage flow inlet flow outlet
connection 1/4
NPTF thd. E
J

C
J B

Discharge to tank
(see Tank Drain, page 18)

Model P Piping Nominal A B C D E F G H J


Thd. Size Capacity
NPTF l/min (USgpm)

3/ 158,8 108,0 53,8 77,7 65,0 68,3 46,0 76,2 57,2


URT*-06-*-10 4 76 (20)
(6.25) (4.25) (2.12) (3.06) (2.56) (2.69) (1.81) (3.00) (2.25)
189,0 127,0 63,5 95,2 77,7 87,4 60,5 95,2 76,2
URT*-10-*-10 11/4 189 (50)
(7.44) (5.00) (2.50) (3.75) (3.06) (3.44) (2.38) (3.75) (3.00)

16
Series URG*-06/10 Unloading Relief Valves

Ratings
Rated Pressure (Maximum) 210 bar (3000 psi)
Rated Capacity (Maximum)
URT*-06 95 l/min (25 USgpm)
URT*-10 246 l/min (65 USgpm)

Model Code

1 2 3 4 5 6 7 8 9

1 Special seals 4 Connections 7 Cutout pressure range


F3 For mineral oil and fire resistant G Manifold or subplate mounted B 24 to 70 bar (350 to 1000 psi)
fluids C 35 to 140 bar (500 to 2000 psi)
Blank Omit for standard models F 103 to 210 bar (1500 to 3000 psi)
5 Drain
1 Externally drained
2 Valve function 8 High vent spring
2 Internally drained
U Unloading valve V Optional high vent spring
installed
6 Valve size Blank Omit if not required
3 Valve type
06 3/4 pipe
R Pressure control valve 10 11/4 pipe
9 Design number
Subject to change. Installation dimensions
same for designs 10 through 19.

General Data The valve may also be used with a


double pump to deliver a large volume
These valves are used in oil hydraulic
of oil to the system at low pressure and
circuits where a pressure regulator is
a small volume at high pressure, serving
required to automatically unload the
the same function as a separate
pump by diverting the pump delivery to
unloading valve and check valve.
the reservoir, at low pressure, when the
accumulator reaches the desired Pressure Adjustment
maximum (or cut out) pressure. When
Pressure can be adjusted by loosening
the accumulator pressure drops to the
a jam nut and turning an adjustment
cut in pressure (approximately 85% of
screw. Turning clockwise increases
the desired maximum), the valve
pressure, and turning counterclockwise
directs pump delivery to the
decreases pressure.
accumulator and hydraulic system. An
integral check valve prevents return
flow from the accumulator through the
unloading valve.

17
Series URG*-06/10 Unloading Relief Valves

Installation Data CAUTION


Tank Drain For series URG1 only, the drain must
Back pressure at the tank discharge be connected to the tank through a
port of the URG1 series (externally surge free line so there will be no
drained) valves will not effect the back pressure at this drain. Failure to
operation at up to 85% of the inlet connect drain can result in infinite
pressure. Back pressure at the system pressures and machine
discharge port of the URG2 series damage. Series URG2 has internal
(internally drained) valves must not drain and this port is not used.
exceed 5% of the inlet pressure.

Approximate Pressure Drop bar (psi)


Nominal Capacity Cut Out Pressure Range Via Check To
Model l/min (USgpm) bar (psi) Unloading Accumulator
URG*-06-B-10 24 to 70 (350 to 1000)
URG*-06-C-10 95 ((25)) 35 to 140 (500 to 2000) 5,9
, ((85)) 2,4
, ((35))
URG*-06-F-10 103 to 207 (1500 to 3000)
URG*-10-B-10 24 to 70 (350 to 1000)
URG*-10-C-10 246 ((65)) 35 to 140 (500 to 2000) 2,4
, ((35)) 1,1
, ((16))
URG*-10-F-10 103 to 207 (1500 to 3000)

Typical Applications

Double Pump Circuit Accumulator Circuit

To
hydraulic Unloading relief valve
system Accumulator
Relief valve
To hydraulic
system Unloading relief valve
To tank To tank

To tank
Vent
connection
Drain (optional)
external drain Vent
connection
Drain
(optional)
Delivery external drain
High pressure, Low pressure, Large from
low volume volume (delivery) pump
(delivery)

18
Series URG*-06/10 Unloading Relief Valves

Installation Dimensions Pressure inlet


connection Discharge to tank (see
Millimeters (inches) Accumulator or
system connection Tank Drain, page 18)
P rad.
URG*-06/10 Valve
50,8
NOTES A (2.00)
* See mounting subplates for locating
dimensions. B

** Keep plugged except when circuit


1.25 hex
indicates connection for venting valve.
0.56 hex

Q thru
R counterbore
S deep
6 holes for mounting*
C
Pressure Vent connection Pressure gage
adjustment control
1/ NPTF**
4 AZ connection (pump
pressure) 1/4 NPTF
D
1/
4
NPTF
(see
CAUTION,
page 15)

L
(fully
K extended)
N J E

6,35 6,35 2 rest pins F


(0.25) M (0.25)

Model A B C D E F G H J
50,8 101,6 139,7 76,2 134,9 160,3 25,4 91,9 124,0
URG*-06-*-10
(2.00) (4.00) (5.50) (3.00) (5.31) (6.31) (1.00) (3.62) (4.88)
60,5 120,6 179,3 95,2 168,1 217,4 33,3 117,3 157,2
URG*-10-*-10
(2.38) (4.75) (7.06) (3.75) (6.62) (8.56) (1.31) (4.62) (6.19)

Model K L M N P Q R S AZ
153,9 180,8 44,4 76,2 15,7 16,8 25,4 15,7 3,0
URG*-06-*-10
(6.06) (7.12) (1.75) (3.00) (0.62) (0.66) (1.00) (0.62) (0.12)
179,3 206,2 63,5 95,2 19,0 17,8 29,5 19,0 1,5
URG*-10-*-10
(7.06) (8.12) (2.50) (3.75) (0.75) (0.78) (1.16) (0.75) (0.06)

19
Series URG*-06/10 Unloading Relief Valves

Mounting Subplates

AC
T thru AD
V UNC2B thd. thru (6 holes) AE
AL AF
AS thru AK AG W X deep
AT AV deep
AW NPTF thd.* (from rear) AJ AH
Y thru Z deep AA
NPTF thd.* (from
rear)

7,9 (0.31)
7,9 (0.31) deep
AQ 2 holes for rest pins
AM AN AP

AR
P rad.

AY 15,7
13,5 thru AB
(0.62)
rad.
AX (0.53)
4 holes for mounting
* Not recommended

Model P T V W X Y Z AA AB AC
15,7 14,0 23,1 31,8 3/ 144,5 112,71
URG1M-06-10 .62511 4
(0.62) (0.55) (0.91) (1.25) (5.69) (4.438)
19,0 16,8 28,4 11,2 38,1 30,5 177,8 146,05
URG1M-10-10 .75010 11/4
(0.75) (0.66) (1.12) (0.44) (1.50) (1.12) (7.00) (5.750)

Model AD AE AF AG AH AJ AK AL AM AN
66,5 55,6 33,3 11,2 10,2 33,3 46,0 46,0 162,1 130,18
URG1M-06-10
(2.62) (2.19) (1.31) (0.44) (0.44) (1.31) (1.81) (1.81) (6.38) (5.125)
88,9 76,2 44,4 19,0 12,7 38,1 50,8 53,8 184,1 152,40
URG1M-10-10
(3.50) (3.00) (1.75) (0.75) (0.50) (1.50) (2.00) (2.12) (7.25) (6.000)

Model AP AQ AR AS AT AV AW AX AY
69,8 35,1 30,2 23,1 3/ 31,8 25,4
URG1M-06-10 4
(2.75) (1.38) (1.19) (0.91) (1.25) (1.00)
82,6 41,1 35,1 28,4 38,1 30,2 38,1 31,8
URG1M-10-10 11/4
(3.25) (1.62) (1.38) (1.12) (1.50) (1.19) (1.50) (1.25)

20
Series XSL/XTL-03 Pressure Reducing Valves

Ratings
Rated Capacity (Maximum) 30 l/min (8 USgpm)
Adjustable Pressure Range 3,4 to 70 bar (50 to 1000 psi)*
Inlet Pressure (Maximum) 140 bar (2000 psi)
* X*L-03-B-10-S21 model has adjustable pressure range of 1,7 to 21 bar (25 to 300 psi) with
maximum inlet pressure of 70 bar (1000 psi).

Model Code

1 2 3 4 5 6 7 8

1 Special seals 4 Pressure level 7 Design number


F3 For mineral oil and fire resistant L Low pressure type Subject to change. Installation dimensions
fluids same for designs 10 through 19.
Blank Omit for standard models
5 Valve size
8 Special feature suffix
03 3/8 pipe
2 Valve type
S21 Adjustable pressure range of
X Pressure reducing valve 1,7 to 21 bar (25 to 300 psi)
6 Pressure range with maximum inlet pressure of
B 3,4 to 70 bar (50 to 1000 psi) 70 bar (1000 psi)
3 Connections Blank Omit if not required
S SAE straight thread
T NPTF thread*
* Not recommended

General Data Pressure Adjustment Drain Connection


The operation of these Vickers reducing A differential of at least 1,7 bar (25 psi) The drain connection must be piped
valves is such that reduced outlet between inlet and outlet pressure must directly to tank. Any pressure at this port
pressure remains constant regardless of be maintained for proper functioning. must be added to the valve pressure
variation of inlet pressure above the setting.
selected pressure setting. Reverse free Adjustment of reduced outlet pressure is
flow is allowable, providing the pressure accomplished by loosening jam nut and
at the reduced pressure port does not turning pressure adjustment control.
exceed the reduced pressure setting of Clockwise rotation increases pressure.
the valve. Counterclockwise rotation decreases
pressure. Control adjustment has stops
for minimum and maximum pressures.

21
Series XSL/XTL-03 Pressure Reducing Valves

Installation Dimensions NOTES


Millimeters (inches) Model XSL-03-B-10 is supplied with 7/814
straight thread system connections and a
XS/TL-03-B-10 Valve 9/ 18 straight thread drain connection.
16

X*L-03-B-10-S21 model has adjustable pressure


range of 1,7 to 21 bar (25 to 300 psi) with
maximum inlet pressure of 70 bar (1000 psi).
Pressure
adjustment * Not recommended.
control can be
rotated to 3 ** Reduced pressure may be adjusted
position 90 apart remotely by connecting this port to
pressure inlet port of CGR-02-*-20 valve
or C-175-*-10 valve. Pressure setting of
main valve must be higher than that of
remote control.

Pressure adjustment control

35,1
57,2 (1.38)
(2.25) 35,1 69,8
(1.38) (2.75)

Jam nut 106,4


(4.19)

102,4 (4.03)
fully
Adjustable reduced pressure Remote control
extended
62,0 44,4 outlet 3/8 NPTF thd.* or 7/814 connection 3/8
(2.44) (1.75) UNF2B straight thd. NPTF thd.**
Drain
Reduced pressure gage connection 1/4
connection 1/4 NPTF thd. NPTF thd.

119,1 80,3
147,6
(4.69) (3.16)
(5.81)

54,9 54,9
(2.16) 32,5 31,8 (2.16)
(1.28) (1.25)
High pressure inlet
41,1 3/ NPTF thd.* or
High pressure 8
(1.62) 7/ 14 UNF2B
gage connection 8
1/ NPTF thd. straight thd.
4
82,6 (3.25)

84,1 (3.31)

22
Series XGL-03 Pressure Reducing Valves

Ratings
Rated Capacity (Maximum) 30 l/min (8 USgpm)
Adjustable Pressure Range 1,7 to 70 bar (25 to 1000 psi)
Inlet Pressure (Maximum) 140 bar (2000 psi)

Model Code

1 2 3 4 5 6 7

1 Special seals 3 Connections 6 Pressure range


F3 For mineral oil and fire resistant G Manifold or subplate mounting B 1,7 to 70 bar (25 to 1000 psi)
fluids
Blank Omit for standard models
4 Pressure level 7 Design number
L Low pressure type Subject to change. Installation dimensions
2 Valve type
same for designs 10 through 19.
X Pressure reducing valve
5 Valve size
03 3/8 nominal size

General Data Pressure Adjustment Drain Connection


The operation of these reducing valves A differential of at least 1,7 bar (25 psi) The drain connection must be piped
is such that reduced outlet pressure between inlet and outlet pressure must directly to tank. Any pressure at this
remains constant regardless of variation be maintained for proper functioning. port must be added to the valve
of inlet pressure above the selected pressure setting.
pressure setting. Reverse free flow is Adjustment of reduced outlet pressure is
allowable, providing the pressure at the accomplished by loosening jam nut and
reduced pressure port does not exceed turning pressure adjustment control.
the reduced pressure setting of the valve. Clockwise rotation increases pressure.
Counterclockwise rotation decreases
pressure. Control adjustment has stops
for minimum and maximum pressures.

23
Series XGL-03 Pressure Reducing Valves

Installation Dimensions
Millimeters (inches)

XGL-03-B-10 Valve

Pressure adjustment control


NOTE
35,1 * Reduced pressure may be adjusted
(1.38) remotely by connecting this port to
57,2 50,8 pressure inlet port of CGR-02-*-20 valve
(2.25) 69,8
(2.00) (2.75) or C-175-*-10 valve. Pressure setting of
main valve must be higher than that of
remote control.
Jam nut
96,8 (3.81) 4,83 2 rest pins
(0.19)

fully 102,4 (4.03)


extended 35,1 Remote control
62,0 (1.38) connection 3/8
(2.44) Remote control NPTF thd.*
connection 3/8 NPTF thd.* Drain
connection

Adjustable
147,6 reduced
(5.81) pressure 30,2
119,1 38,1 outlet (1.19)
(4.69) (1.50) 112,8
(4.44) 26,2
Reduced (1.03)
pressure gage 47,8
connection 1/4 (1.88) 31,8
NPTF thd. (1.25)
High
6,4 pressure
High pressure (0.25)
gage connection inlet
1/ NPTF thd. 31,8
4
(1.25)
62,0
(2.4
4)
74,7
(2.94)

24
Series XGL-03 Pressure Reducing Valves

Mounting Subplate

Model XGLM-10S-03-10

73,03
10,4 (0.41) thru (2.875)
15,0 (0.59) counterbore 12,7 5/
9,7 (0.38) deep 38,10 1618 UNC2B
(0.50) thd. thru 4 places
4 places (1.500)
3/16

9,7
(0.38)
35,1 109,5
(1.38) 25,40
(4.31)
(1.000)
88,90
(3.500)
25,40
35,1 (1.000)
(1.38)

6,4
rad.
(0.25)
8,73
rad. 3,0
(0.344) 12,7
(0.12) (0.50)
15,7 26,2 30,2
(0.62) (1.03) (1.19) 7/16
6,35 81,0 (3.19)
(0.2 5,6 (0.22)
5) 7,9 (0.31) deep
93,7 (3.69)
2 places

1,57 2,38 1,57


(0.062) (0.094) (0.062)

26,9
19,8 19,05 15,7 (1.06)
(0.78) (0.75) (0.62)

7/ 9/
814 UNF2B straight 1618 UNF2B straight thd.
thd. for 5/8 O.D. tube for 3/8 O.D. tube

25
Series X(C)*-03/06/10 Pressure Reducing Valves

Ratings
Rated Capacity (Maximum) 530 l/min (140 USgpm)
Inlet Pressure (Maximum) 210 bar (3000 psi)

Model Code

1 2 3 4 5 6 7 8 9

1 Special seals 5 High-flow designation 8 Maximum rated flow capacity


F3 For mineral oil and fire resistant H High-flow valve B* Size Flow l/min (USgpm)
fluids Size Flow l/min (USgpm) 03 26,5 (7)
Blank Omit for standard models 03 114 (30) 06 57 (15)
06 265 (70) 10 189 (50)
10 530 (140) F Size Flow l/min (USgpm)
2 Valve type Blank Omit for B and F models 03 53 (14)
X Pressure reducing valve 06 114 (30)
10 284 (75)
6 Valve size Blank Omit for H high-flow models
3 Integral check valve 03 3/8 pipe or 0.7500-16 UNF-2B * Not available with 3 maximum adjustable
C Reverse free flow check straight thread (0.500 tubing) pressure.
06 3/4 pipe or 1.0625-12 UN-2B
straight thread (0.750 tubing)
4 Connections 10 11/4 pipe or 1.6250-12 UN-2B 9 Design number
straight thread (1.250 tubing) Subject to change. Installation dimensions
G Manifold or subplate mounting
S SAE straight thread same for designs 30 through 39.
T NPTF thread* 7 Maximum adjustable pressure
* Not recommended 1 70 bar (1000 psi)
2 140 bar (2000 psi)
3 210 bar (3000 psi)*
* 10,3 bar (150 psi) pressure drop across
valve minimum recommended. Not available
with B flow capacity.

26
Series X(C)*-03/06/10 Pressure Reducing Valves

General Data Contact your Vickers representative if pressure. Control adjustment has stops
maximum inlet pressure is needed with for minimum and maximum pressures.
The operation of these reducing valves is
minimum rated reduced pressure.
such that reduced outlet pressure remains
Drain Connection
constant regardless of variation of inlet
Adjustment of reduced outlet pressure is The drain connection must be piped
pressure above the selected pressure
accomplished by loosening jam nut and directly to tank through a surge free line.
setting. Reverse free flow from reduced
turning pressure adjustment control. Any continuous drain line pressure must
pressure outlet connection to high
Clockwise rotation increases pressure. be known and that value added to the
pressure inlet connection is provided by
Counterclockwise rotation decreases valve pressure setting.
optional integral check valve.

Pressure Adjustment
A differential of at least 10,3 bar (150 psi)
between inlet and outlet pressure must
be maintained for proper functioning.

Graphical Symbols

XS-**-*-30 XCS-**-*-30
Remote
control

Remote
control
Gage Drain Gage Drain

Gage
Gage

XG-**-*-30 XCG-**-*-30

Gage Gage
Remote Remote
control control

Gage Gage

Drain Drain

27
Series X(C)*-03/06/10 Pressure Reducing Valves

Performance Curves
Based on fluid with specific gravity of 0.865 and viscosity of 20 cSt (100 SUS)

Outlet Pressure vs. Flow


210 bar (3000 psi) inlet
X**-03-**-30 Valve Pressure Drop vs. Flow
3000
200
 X*G valves
03-3F H03-3  X*S/T valves 18
2500 250
16
REDUCED PRESSURE psi

03 size 06 size

REDUCED PRESSURE bar


150

REDUCED PRESSURE bar


14

REDUCED PRESSURE psi


2000 200
03-2B 10 size
03-2F H03-2 12

1500 100 150 10

8
1000 100
6
03-1B 03-1F H03-1 50
4
500 50
2

0 0 0 0
0 5 10 15 20 25 30 35 0 20 40 60 80 100 120 140
OUTLET FLOW USgpm OUTLET FLOW USgpm

X**-10-**-30 Check Valve Pressure Drop vs. Reverse Free Flow


3000
200

10-3F XC*-***-**-30 18
2500 250
H10-3 16
REDUCED PRESSURE psi

REDUCED PRESSURE bar

150 03 size

REDUCED PRESSURE bar


14
REDUCED PRESSURE psi

2000 200

10-2B 10-2F 12

1500 100 150 10


H10-2
06 size 8
1000 100
6
50 06 size
10-1B 10-1F 4
500 50
H10-1 2

0 0 0 0
0 20 40 60 80 100 120 140 0 20 40 60 80 100 120 140
OUTLET FLOW USgpm OUTLET FLOW USgpm

X**-06-**-30 Drain (Control) Flow vs. Valve Pressure Drop


3000
200 (InletOutlet) at Any Flow Condition
06-3F H06-3 18
2500 250
16
REDUCED PRESSURE psi

REDUCED PRESSURE bar

150
REDUCED PRESSURE bar

2000 200 14
DRAIN FLOW in3 /min

06-2B 06-2F H06-2 12

1500 100 150 Typical range 10

8
1000 100
6
06-1B 50
06-1F H06-1 4
500 50
2

0 0 0 0
0 10 20 30 40 50 60 70 0 20 40 60 80 100 120 140
OUTLET FLOW USgpm PRESSURE DROP psi

28
Series X(C)*-03/06/10 Pressure Reducing Valves

Minimum Adjustable Pressure vs. Flow


140 bar (2000 psi) inlet

X**-*03-**-30 X**-*10-**-30
400 400
25 25
REDUCED PRESSURE psi

REDUCED PRESSURE psi


REDUCED PRESSURE bar

REDUCED PRESSURE bar


300 20 300 20

15 15
200 H03 200 H10
10-*F
03-*F 10 10
100 100
5 5
10-*F
03-*F
0 0 0 0
0 5 10 15 20 25 30 35 0 20 40 60 80 100 120 140
OUTLET FLOW USgpm OUTLET FLOW USgpm

X**-*06-**-30
400
25
REDUCED PRESSURE psi

REDUCED PRESSURE bar

300 20

15
200 H06
06-*F 10
100
5
06-*F
0 0
0 10 20 30 40 50 60 70
OUTLET FLOW USgpm

Valve Pressure Adjustment 2. Turn pressure adjustment control all 4. Tighten 1.125 hex nut against body
the way in so .562 jam nut and to lock maximum pressure setting in
Maximum pressure for each specific
pressure adjustment control head place.
pressure range is pre-set at the factory
are tight against end of large screw.
with the large screw and held in place
1. Back out pressure adjustment
by the 1.125 hex nut.
3. With 1.125 hex nut backed-off for control to desired working pressure
clearance, continue turning pressure and lock in place with .562 jam nut.
Sensitivities for the different pressure
adjustment control (with large screw
ranges are: a)185 psi/rev for 1000 psi
locked to it) until desired maximum
max. pressure (5.4 turns total); b) 295
pressure is reached.
psi/rev for 2000 psi max. pressure (6.8
turns total); and c) 485 psi/rev for 3000 .562 jam
1.125 hex nut Pressure
psi max. pressure (6.2 turns total). To nut
adjustment


lower the maximum pressure: Large screw
control

1. Start large screw approximately 2 to





3 turns into body, then assemble



1.125 hex nut, pressure adjustment
control, and .562 jam nut.


Body

29
Series X(C)*-03/06/10 Pressure Reducing Valves

Installation Dimensions NOTES


Millimeters (inches) Optional adjustment control positions obtained by
Subplate or Manifold Mounted Models rotating cover assembly. Position #1 is standard.
Position #2 cannot be used. Position #3 can be
XG- * * - * -30 Without Check
used (if it does not interfere with the manifold)
Control
F position #4 providing that the external drain in the cover is
connected.
Control Optional remote control connection*
position #3 .562518 UNF2B straight thd. * Available with (H)06 and (H)10 models
Jam nut only.
** See mounting subplates for locating
53,8 dimensions.
E sq.
(2.12)  .5625-18 UNF-2B straight thread. Reduced
K pressure may be adjusted remotely by
Control connecting this port to pressure inlet port
position #2 Control of CGR-02-*-20 valve or C-175-*-10 valve.
position #1 Pressure setting of main valve must be
6,35 higher than that of remote control.
(0.25)** 13,2 120,6 (4.76)
(0.52) fully extended to minimum  .4375-20 UNF-2B straight thread.
pressure stop
Remote Pressure adjustment control (knob
control can be backed out beyond
connection L minimum pressure stop)
Optional
external drain
High pressure
inlet
Adjustable
High pressure gage reduced
connection pressure outlet
Port
A Reduced not
pressure gage Drain (see Drain used
H Connection,
connection
page 27)
M
N 10,3 (0.406) thru B
15,1 (0.594) counterbore C
D number of holes for
mounting**

6,35 J
(0.25)
G

NFPA
Model A B C D E F G H J K L M N Interface
142,2 46,7 29,5 57,2 36,6 68,1 116,8 55,9 28,4 24,6 66,0 41,9
X(C)G-03-*-30 4 P03
(5.60) (1.84) (1.16) (2.25) (1.44) (2.68) (4.60) (2.20) (1.12) (0.97) (2.60) (1.65)
176,5 66,8 44,7 71,4 41,1 79,2 151,1 68,6 35,8 29,5 96,8 65,0
X(C)G-06-*-30 4 P06
(6.95) (2.63) (1.76) (2.81) (1.62) (3.12) (5.95) (2.70) (1.41) (1.16) (3.81) (2.56)
211,3 71,4 44,7 95,2 50,8 100,1 182,6 90,2 47,8 41,4 101,6 72,4
X(C)G-10-*-30 6 P10
(8.32) (2.81) (1.76) (3.75) (2.00) (3.94) (7.19) (3.55) (1.88) (1.63) (4.00) (2.85)

30
Series X(C)*-03/06/10 Pressure Reducing Valves

Subplate or Manifold Mounted Models (continued)


XCG- * * - * -30 With Check
(See previous page for other details and dimensions)

Reversed free
flow outlet

Reversed
free flow inlet

R
P

Model G P R
90,4 41,9 66,0
XCG-03-*-30
(3.56) (1.65) (2.60)
98,6 59,7 85,9
XCG-06-*-30
(3.88) (2.35) (3.38)
130,3 72,4 101,6
XCG-10-*-30
(5.13) (2.85) (4.00)

31
Series X(C)*-03/06/10 Pressure Reducing Valves

Threaded Port Models Control position #2


Drain connection* (see NOTES
XT- * * - * -30 L Optional adjustment control positions
G Drain Connection,
Without Check obtained by rotating cover assembly. Position
page 27)
#1 is standard. Position #2 cannot be used on
Jam nut Control XS/T-10 models. Position #3 cannot be used.
J position #3 * .5625-18 UNF-2B straight thread.

53,8 ** Available with (H)06 and (H)10 models


M only.
(2.12)
 .5625-18 UNF-2B straight thread. Reduced
pressure may be adjusted remotely by
Control
connecting this port to pressure inlet port
position #1
of CGR-02-*-20 valve or C-175-*-10 valve.
13,2 Pressure setting of main valve must be
Control F Optional
(0.52) higher than that of remote control.
position #4 D sq. remote control
connection**  .4375-20 UNF-2B straight thread.
120,6 (4.76)
fully extended to minimum
pressure stop Remote control
connection

High pressure
gage connection

Pressure adjustment
control (knob can be A
backed out beyond C High pressure
B
minimum pressure stop) inlet (either
side)
Reduced S
pressure outlet K Reduced pressure
R
gage connection
System connections
T thd. 3 places
E wrench flat
3 places

Model A B C D E F G H J
142,2 116,8 23,1 59,4 35,1 29,7 39,6 24,6 35,1
X(C)S/T-03-*-30
(5.60) (4.60) (0.91) (2.34) (1.38) (1.17) (1.56) (0.97) (1.38)
176,5 151,1 26,9 74,7 50,8 37,3 50,8 29,5 47,8
X(C)S/T-06-*-30
(6.95) (5.95) (1.06) (2.94) (2.00) (1.47) (2.00) (1.16) (1.88)
211,3 182,6 28,4 98,6 86,4 49,3 68,3 41,4 53,8
X(C)S/T-10-*-30
(8.32) (7.19) (1.12) (3.88) (3.40) (1.94) (2.69) (1.63) (2.12)

T for X(C)T
Model K L M R S T for X(C)S models models
46,0 70,9 69,9 41,9 66,0 .750016 UNF2B str thd. 3/
X(C)S/T-03-*-30 8 NPTF thd.
(1.81) (2.79) (2.75) (1.65) (2.60) (1/2 O.D. tubing)
69,8 88,1 95,3 65,0 96,8 1.062512 UNF2B strr thd. 3/
X(C)S/T-06-*-30 4 NPTF thd.
(2.75) (3.47) (3.75) (2.56) (3,81) (3/4 O.D. tubing)
81,0 117,3 108,0 72,4 101,6 1.625012 UNF2B strr thd.
X(C)S/T-10-*-30 11/4 NPTF thd.
(3.19) (4.62) (4.25) (2.85) (4.00) (11/4 O.D. tubing)
 Not recommended

32
Series X(C)*-03/06/10 Pressure Reducing Valves

Threaded Port Models (continued)


XCS/T- * * - * -30 With Check
(See previous page for other details and dimensions)
L

Reversed free
flow outlet

Reversed
free flow inlet

P
N

Model L N P
93,7 41,9 66,0
XCS/T-03-*-30
(3.69) (1.65) (2.60)
108,0 59,7 84,6
XCS/T-06-*-30
(4.25) (2.35) (3.33)
147,6 72,4 101,6
XCS/T-10-*-30
(5.81) (2.85) (4.00)

33
Series X(C)*-03/06/10 Pressure Reducing Valves

Mounting Subplates P
N
When a subplate is not used, a E
machined pad (as indicated by D E K straight thd. (from
shaded area) must be provided D reverse side) 2 holes
for mounting. The pad must be M
flat within 0,013 mm (0.0005 in) P subplates for P model
and smooth within 1,6 mm (63 L valves only. Straight thread
microinch). Mounting bolts port subplates are not
provided by the customer should available with P port option.
be SAE grade 7 or better.
U 10,31 (0.406) thru
.37516 UNC2B thd. CC T
number of mounting holes B 15,09 (0.594) counterbore
PP Z B A 9,65 (0.38) deep 4 holes
RR A
LL
GG SS
JJ
KK UU
MM X
V H Y R
H

7,14 (0.281) for rest pin 7,87 W rad.


(0.31) dp
4,76 (0.1875) drill thru TT FF 2 ports Drain port for RG and
.562518 UNF2B thd. (from RCG-**-*2/3-30 models
reverse side) S rad. 2 places

Tube
Model K O.D. L M N P R S T U V
.750016 1 25,4 19,0 63,5 127,0 76,2 23,9 43,7 87,4 63,5
RXGM-03S-(P)-20 /2
UNF2B (1.00) (0.75) (2.50) (5.00) (3.00) (0.94) (1.72) (3.44) (2.50)
1.31251 31,8 19,0 73,2 146,0 117,3 39,6 50,8 101,6 82,6
RXGM-06SX-(P)-20 1
2 UN2B (1.25) (0.75) (2.88) (5.75) (4.62) (1.56) (2.00) (4.00) (3.25)
1.62501 1 47,8 22,4 79,2 158,8 146,0 47,8 58,7 117,3 104,6
RXGM-10S-(P)-30 1 /4
2 UN2B (1.88) (0.88) (3.12) (6.25) (5.75) (1.88) (2.31) (4.62) (4.12)

0,13 0,013
Model W X Y (0.005) Z AA BB CC DD EE(0.005) FF GG
10,4 35,8 42,87 25,4 33,3 66,5 53,1 106,37 14,2 21,3
RXGM-03S-(P)-20 4
(0.41) (1.41) (1.688) (1.00) (1.31) (2.62) (2.09) (4.188) (0.56) (0.84)
10,2 49,3 60,32 33,3 39,6 79,2 62,0 123,82 23,1 20,6
RXGM-06SX-(P)-20 4
(0.44) (1.94) (2.375) (1.31) (1.56) (3.12) (2.44) (4.875) (0.91) (0.81)
10,4 67,6 84,12 44,4 48,5 96,8 69,1 138,12 28,4 24,6
RXGM-10S-(P)-30 6
(0.41) (2.66) (3.312) (1.75) (1.91) (3.81) (2.72) (5.438) (1.12) (0.97)

NFPA
Model HH JJ KK LL MM PP RR SS TT UU Interface
28,4 31,8 4,8 38,1 6,4 10,4 25,4 21,3
RXGM-03S-(P)-20 P03
(1.12) (1.25) (0.19) (1.50) (0.25) (0.41) (1.00) (0.84)
38,1 44,4 6,4 53,8 17,5 11,2 16,8 33,3 39,6
RXGM-06SX-(P)-20 P06
(1.50) (1.75) (0.25) (2.12) (0.69) (0.44) (0.66) (1.31) (1.56)
50,8 42,2 62,7 7,9 76,2 20,6 10,4 24,6 44,4 59,4
RXGM-10S-(P)-30 P10
(2.00) (1.66) (2.47) (0.31) (3.00) (0.81) (0.41) (0.97) (1.75) (2.34)
 RXGM-03S/06SX require 4 valve mounting screws. RXGM-10S requires 6 valve mounting screws.

34
Application Data

Weights The following table lists the approximate The following table lists the appropriate
weight of each subplate in the catalog: subplate for use with each manifold or
The following table lists the approximate
subplate mounted valve in the catalog:
weight of each valve in the catalog:
Weight
Subplate kg (lbs) Valve Subplate
Weight
Valve kg (lbs) RXGM-03S-20 1,5 (3.25) RG-03-*-30 RXGM-03S-20
RS/T-03-*-30 2,7 (6.0) RXGM-06SX-20 2,9 (6.50) RG-06-*-30 RXGM-06SX-20
RS/T-06-*-30 5,7 (12.5) RXGM-10S-30 5,0 (11.00) RG-10/12-*-30 RXGM-10S-30
RS/T-10/12-*-30 12,0 (26.5) URG1M-06-10 5,7 (12.5) RCG-03-*-30 RXGM-03S-20
RCS/T-03-*-30 2,9 (6.5) URG1M-10-10 9,3 (20.5) RCG-06-*-30 RXGM-06SX-20
RCS/T-06-*-30 5,9 (13.0) XGLM-10S-03-10 1,4 (3.0) RCG-10/12-*-30 RXGM-10S-30
RCS/T-10/12-*-30 12,9 (28.5) URG*-06-*-10 URG1M-06-10
Fluids and Seals
RG-03-*-30 3,6 (8.0) URG*-10-*-10 URG1M-10-10
For best results, oil viscosity should
RG-06-*-30 6,4 (14.0) range between 32 cSt and 49 cSt (150 XGL-03-B-10 XGLM-10S-03-10
RG-10/12-*-30 11,8 (26.0) SUS and 225 SUS) at 38C (100F) with XG-03-*-30 RXGM-03S-20
a maximum operating temperature of
RCG-03-*-30 3,9 (8.5) 68C (155F). Water glycol, water-in-oil XG-06-*-30 RXGM-06SX-20
RCG-06-*-30 6,6 (14.5) emulsions, and petroleum oil may be XG-10-*-30 RXGM-10S-30
used with non-F3 models, which are
RCG-10/12-*-30 12,7 (28.0) XCG-03-*-30 RXGM-03S-20
furnished with Buna-N seals for the
URT*-06-*-10 4,5 (10.0) mounting surface and fluorocarbon XCG-06-*-30 RXGM-06SX-20
URT*-10-*-10 9,1 (20,0) seals internally. Add F3 prefix when XCG-10-*-30 RXGM-10S-30
phosphate ester type fluids or blends
URG*-06-*-10 11,3 (25.0) are to be used. Refer to 694 for The following table lists the appropriate
URG*-10-*-10 22,0 (48.5) hydraulic fluid and temperature bolt kit for each subplate mounted valve
recommendations. in the catalog:
XS/TL-03-B-10 4,1 (9.0)
XGL-03-B-10 4,1 (9.0) The use of synthetic, fire-resistant fluids
Valve Bolt Kit
XG-03-*-30 3,9 (8.5) requires a valve with special seals.
R(C)G-03-*-30 BKRX03660
XG-06-*-30 6,1 (13.5) Subplates and Bolt Kits R(C)G-06-*-30 BKRX06661
XG-10-*-30 11,8 (26.0) Valves, subplates, and mounting bolts
R(C)G-10-*-30 BKRX10662
XCG-03-*-30 4,1 (9.0) must be ordered separately.
URG*-06-*-10 BKUR06682
XCG-06-*-30 6,4 (14.0) Example: URG*-10-*-10 BKUR10683
XCG-10-*-30 12,2 (27.0) (1) URG*-06-12 valve
(1) URG1M-06-10 subplate XGL-03-B-10 BKXL03663
XS/T-03-*-30 3,2 (7.0) (1) BKUR06682 bolt kit (consisting of X(C)G-03-*-30 BKRX03660
XS/T-06-*-30 5,7 (12.5) two bolts, 5/811 x 2.50, and four bolts,
5/ 11 x 5.25) X(C)G-06-*-30 BKRX06661
XS/T-10-*-30 11,3 (25.0) 8
X(C)G-10-*-30 BKRX10662
XCS/T-03-*-30 3,4 (7.5)
XCS/T-06-*-30 5,9 (13.0) When a subplate is not used, a machined
pad (as indicated by shaded area on
XCS/T-10-*-30 11,8 (26.0) subplate installation dimensions pages)
must be provided for mounting. The pad
must be flat within 0,013 mm (0.0005 in)
and smooth within 1,6 mm (63 microinch).
Mounting bolts provided by the customer
should be SAE grade 7 or better.

35
Application Data

Fluid Cleanliness contacting Vickers, Incorporated. Vickers products, as any components,


Recommendations on filtration and the will operate with apparent satisfaction in
Proper fluid condition is essential for
selection of products to control fluid fluids with higher cleanliness codes than
long and satisfactory life of hydraulic
condition are included in 561. those described. Other manufacturers
components and systems. Hydraulic
will often recommend levels above
fluid must have the correct balance of
Recommended cleanliness levels, using those specified. Experience has shown,
cleanliness, materials, and additives for
petroleum oil under common conditions, however, that life of any hydraulic
protection against wear of components,
are based on the highest fluid pressure component is shortened in fluids with
elevated viscosity, and inclusion of air.
levels in the system and are coded in the higher cleanliness codes than those
chart below. Fluids other than petroleum, listed below. These codes have been
Essential information on the correct
severe service cycles, or temperature proven to provide a long, trouble-free
methods for treating hydraulic fluid is
extremes are cause for adjustment of service life for the products shown,
included in Vickers publication 561
these cleanliness codes. See Vickers regardless of the manufacturer.
Vickers Guide to Systemic
publication 561 for exact details.
Contamination Control available from
your local Vickers distributor or by

System Pressure Level


bar (psi)
Product <70 (<1000) 70-207 (1000-3000) 207+ (3000+)
Vane Pumps Fixed 20/18/15 19/17/14 18/16/13
Vane Pumps Variable 18/16/14 17/15/13
Piston Pumps Fixed 19/17/15 18/16/14 17/15/13
Piston Pumps Variable 18/16/14 17/15/13 16/14/12
Directional Valves 20/18/15 20/18/15 19/17/14
Pressure/Flow Control Valves 19/17/14 19/17/14 19/17/14
CMX Valves 18/16/14 18/16/14 17/15/13
Servo Valves 16/14/11 16/14/11 15/13/10
Proportional Valves 17/15/12 17/15/12 15/13/11
Cylinders 20/18/15 20/18/15 20/18/15
Vane Motors 20/18/15 19/17/14 18/16/13
Axial Piston Motors 19/17/14 18/16/13 17/15/12
Radial Piston Motors 20/18/14 19/17/13 18/16/13

36

Вам также может понравиться