Вы находитесь на странице: 1из 1

Service & Repair Simulating On/Off Control

Simulating On/Off: 6000B TU:


To simulate a manual switching ON of TU in case ECM PCB
the system is not able to turn on from the CU:
Locate pin 8 (Supply_ON) on TU-CU Bus
connector.
Use a screwdriver with its tip touches pin 8
and body momentarily touches chassis.
Both TU & CU should turn ON.

Screw drivers
tip on pin-8
Body touches
chassis.

6000A TU:
Control/Interconn
PCB

209 SAILOR 6000A/B Series MF/HF 2016 Revxxx E-2 2-Feb-17 Cobham SATCOM