1
D 2890 92 (2003)
2
D 2890 92 (2003)
would, in the long run, in the normal and correct operation of 204C), and end points in the range 430 to 535F (221 to 279C). Each
the test method, exceed the following value only in one case in laboratory determined the required distillation and gravity data in dupli-
twenty: cate, and performed the procedures graphically once for each of the two
sets of determined data for each sample. Heat capacities of the fuels were
0.01 Btu/lb F ~0.04 kJ/kg K! (2) not determined during the cooperative program.
8.1.2 ReproducibilityThe difference between two, single 8.2 The accuracy of this test method has been reported3 as
and independent results, obtained by different operators work- within 4 % for straight-run petroleum fractions and approxi-
ing in different laboratories on identical test material, would, in mately 8 % for pure olefins.
the long run, in the normal and correct operation of the test 8.3 BiasSince there is no accepted reference material
method, exceed the following value only one case in twenty: suitable for determining bias for this test method, no statement
0.02 Btu/lb F ~0.08 kJ/kg K! (3) of bias can be made.
NOTE 3The preceding repeatability and reproducibility were obtained
from results submitted by seven laboratories that cooperatively tested four
9. Keywords
turbine fuels with initial boiling points in the range 320 to 400F (160 to 9.1 liquid heat capacity; petroleum distillate
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org).