Spring 2003
PIPE FRICTION
Objective
To estimate the fluid pressure drops and roughness specifications for copper tubing of
four different diameters.
Lab
The schematic of the apparatus is shown in appendix 1. The pressure drop will be
estimated for the four copper tubes by measuring four different flow-rates. The pressure
drops will also be measured using the differential pressure measurement device installed
on the apparatus. The results will be compared to identify the pipe roughness
specifications for the copper tubing.
Theory
In a horizontal pipeline flowing full, the head loss (hL) between any two points is given
by:
p − p2
hL = 1 (1)
γ
1
The friction factor, f, for flow of liquids in pipelines is defined as:
hL
f = (2)
L V2
D 2g
where L and D are the length and inside diameter of the pipe.
The value of the friction factor is a function of the Reynolds Number (Re) and relative
roughness (ε/D). Figure 2 shows the functional dependence of f on Re and ε/D and is
called the Moody Diagram. Some salient features of the Moody Diagram are: (i) for
very smooth pipes and for laminar flow, f is a function of Re only, and (ii) for wholly
turbulent flow (as the Reynolds number becomes very high), f is a function of ε/D only.
Experimental Procedure
When the system has not been in use for quite some time, air bubbles will form in the
vertical differential manometer tubes and the pipelines. The system should be purged of
the air bubbles by following the procedure given below.
2
Pipe 1 - 3/8” Copper Tubing (10.922 mm I.D.)
Open valves 13, 17, 18, 19, 52 and 44. Close valve 10 and all Manifold valves,
except valve 22 on Manifold 1 and valve 30 on Manifold 2.
When the appropriate valves are opened, the following procedure should be followed:
(1) Reduce the flowrate using valve 52.
(2) Record the flowrate from the flow meter and the pressure difference from the
manometer.
(3) Use four different flow rates for each pipeline.
Results
1. Calculate the Reynolds Number, Re, and the friction factor, f for each of the runs on
the four pipes.
2. Identify the roughness specifications (e.g., could the tubing be considered as Smooth
Pipe? or estimate a relative roughness, ε/D, and the absolute roughness, ε, for each pipe)
3. Compare the results with values for new copper tubing and discuss your results.
3
4
5
Figure 3.
Appendix 2
Pipe 1: I.D. =
Q hL V f Re ε/D ε
(litre/min)
Pipe 2: I.D. =
Q hL V f Re ε/D ε
(litre/min)
Pipe 3: I.D. =
Q hL V f Re ε/D ε
(litre/min)
Pipe 4: I.D. =
Q hL V f Re ε/D ε
(litre/min)