The reliable solution THD is held within two percent Inherent redundancy option:
When at or below 50% capacity,
of nominal specification for
When it comes to reliability, the 9395's uninterruptible power
linear loads, and within five modules (UPMs) automatically
the 9395 leaves competitive
percent for nonlinear loads act as N+1 redundant systems
UPSs in the dust. Providing
making the 9395 ideal for
high availability for your critical
supporting equipment that is
systems at all times, the 9395
sensitive to a distorted voltage
was designed with numerous
input. Additionally, the 9395
technological advancements
excels at supporting leading
that create an unprecedented
power factor loads, which are
level of reliability while
becoming more prevalent in
emphasizing serviceability
new or updated data centers.
lowering MTTR and
The 9395 handles leading
enhancing availability.
loads, down to 0.9 power factor
Double-conversion without derating.
design offers the highest
protection possible Inherent redundancy option
Unlike some other commercially Surveys focused on efficiency in
available UPS technologies, data centers reveal that UPSs are
the double-conversion design often under-loadedfrequently at
completely isolates output less than 50 percent. To capitalize
power from all input power on this trend and create even
anomalies and delivers greater reliability, you have the
100-percent conditioned, perfect option to configure the 9395 with
sine-wave outputregulating inherent redundancy. Traditional
both voltage and frequency. UPS manufacturers cannot
Even when presented with deliver this additional availability
the most severe power without adding a more costly
disturbances, power output second UPS module.
remains stable. Output voltage UPM #1 UPM #2
www.eaton.com/9395 1.800.356.5794 2
Batteries: The heart of every UPS Service and support enhance performance
When a utility power outage causes a UPS to switch to battery Eaton recognizes that superior power reliability requires flawless
power, it is imperative that those batteries are healthy, charged and execution from its services team. Every 9395 includes an on-site
up to the task. Improper battery management is the number one startup from a factory-trained field technician to insure proper
cause of downtime. Many UPS batteries on the market today are installation, operation, and customer training. In addition, we
constantly trickle-chargeda process that degrades the batterys include a full year of on-site 7x24 parts and labor warranty and
internal chemical composition over time, reducing potential battery service protection plan coverage at no extra charge. Finally,
service life by as much as 50 percent. To address this, the 9395 our experts will remotely diagnose, trend, and proactively spot
uses a sensing circuit and an innovative three-stage charging problems and expedite field technicians with appropriate parts
technique to significantly extend battery service life and optimize when required during the first year with our advanced eNotify
recharge time. In addition, temperature-compensated charging Remote Monitoring Service. Included at no extra charge with
monitors temperature changes, and adjusts the rate of charge to every 9395:
prolong battery life.
7x24x365 startup service and customer training
Monitor batteries for optimum readiness One-year limited factory warranty1
Advances in firmware and digital technology enable the 9395 to Service protection plan 7x24 coverage, eight-hour response
offer sophisticated battery monitoring and management features (upgrade to four- or two-hour where available), parts and labor,
that you might expect to find only on expensive add-on systems, unlimited on-site emergency response support
including: eNotify Remote Monitoring Service: 7x24 critical
alarm notification and monthly reports on UPS and battery health
Battery runtime remaining monitor uses system loading and 7x24 technical support access
trended battery discharge data plus internal sensing points for
voltage and current data to calculate runtime remaining
Battery circuit test performs a periodic full-load test of the
battery string to ensure that there are no open circuits or weak
cells that would jeopardize battery performance and system
availability
UPS output power will turn off after the configured delay period
Low battery alarm present
UPS hardware fault detected
UPS battery completely discharged
UPS inverter fault detected
UPS internally bypassed
UPS output has been turned off
UPS shutdown imminent alarm condition exists
The failure of one or more fuses has been detected Sent via email to as many as six site contacts, the eNotify monthly
A relay, contactor, or breaker has failed Customer Monitoring Report provides a summary of the top 10
performance and environmental parameters, battery events, availability
percentage, and comparative status against recommended specification.
The eNotify Remote Monitoring Service provides confidence that
Eaton is continually watching your 9395 and will combine its tech-
nical resources and field technicians as needed to quickly respond Unmatched green power performance
to critical alarms. The innovative design of the 9395 delivers the industrys best
performance combination of high efficiency, low input current
distortion and high power factor. The 9395 operates at greater than
94 percent efficiency, reducing utility costs and extending battery
runtimes. Higher system efficiency also results in cooler operating
conditions, which reduces facility air conditioning cost, extends
The innovative design of the the life of UPS components, and increases overall reliability, avail-
Eaton 9395 delivers the industrys ability, and performance. A new input circuit design within the
9395 keeps input current THD low and input power factor near
best performance combination of unity without compromising overall efficiency. As a result, the UPS
high efficiency, low input current allows maximum transfer of power between the power source and
distortion and high power factor. the protected load and is exceptionally compatible with multiple
power sources, especially auxiliary generators. On the output side,
the ultra high-speed switching pulse width modulation (PWM)
inverter enables the 9395 to provide its full rated power capability
to the load whether the load power factor is 0.9 lagging, unity, or
0.9 leading.
The use of sustainable materials and highly efficient manufacturing
technology results in dramatic savings in carbon footprint versus
similar UPS products.
www.eaton.com/9395 1.800.356.5794 4
Measuring power performance: Efficiency, power factor, and THD
Power performance, which is measured by system efficiency, output power factor, and THD, is the
foundation of the Eaton 9395. It is the UPSs robust combination of these three elements that make
it stand out as the premier UPS in its class. The table below demonstrates how the 9395 with Energy
Saver System compares to competitive UPS models. Most manufacturers must use input filters,
which lower their efficiency rating. The 9395, on the other hand, does not require input filters to obtain
excellent input THD.
As an example, a large data center (2.2 MVA) would realize the following savings by using a 9395 in
Energy Saver System (ESS) compared to traditional N+1 systems:
Additional energy savings: 2917 MW hours
Additional carbon savings: 2523 tons
Annual cost savings: $315,708
Eaton 9395 (with ESS) ANNUAL Power SAVINGS vs. The Competition
Model kVA rating Full load Half load power savings Cooling power savings Total savings at half load
annual power savings at half load (power and cooling)
Eaton 9395 1100
vs. Competitor A 1000 $66,300 $35,700 $23,800 $59,500
vs. Competitor B 1000 $20,400 $15,300 $10,200 $25,500
costs calculated at industry average of $.10 per KWH
Model kVA rating KW per sq. foot Annual space cost savings (at $1000 per sq. foot)
Eaton 9395 1100 25.5
vs. Competitor A 1000 16.6 $15,000
vs. Competitor B 1000 16.9 $20,000
UPS EFFICIENCIES
EATON UPS WITH ESS
100%
EATON UPS
LEGACY UPS
UPS EFFICIENCY
90%
80%
TYPICAL
OPERATION
70%
20% 30% 40% 50% 60% 70% 80% 90% 100%
UPS LOAD
Scalable, redundant archi- 275 kVA UPM 825 kVA ISBM 275 kVA UPM 275 kVA UPM 275 kVA UPM
tecture meets current and
future requirements
The 9395 combines the reliability
and redundancy of a multi-module
UPS into an integrated, pre-wired
solution. With a unique, flexible
design that provides scalability,
the UPS can adapt to future
changes in load demands and
new requirements for higher
reliability without requiring the
purchase of an additional UPS.
For example, the 9395 UPS
enables you to add a 275 kVA
UPM in the field for N+1 redun-
dancy or capacity. Eaton 9395 825 kVA
www.eaton.com/9395 1.800.356.5794 6
System Bypass Module: customizable cabinet features system controls/monitoring Peer-to peer architecture which
unparalleled flexibility for a 10 inch color LCD screen to section may also be deployed operates the parallel system
your parallel UPS system display status for up to 32 of in custom or third party without the need for master
Four decades of experience in the UPM modules, and provides switchgear, to ensure that load share or master synchro-
paralleling large UPS systems an intuitive user operation the most reliable monitoring nization controls. The system
is incorporated in this newest interface. and user-friendly controls are operates with NO centralized
System Bypass Module included with alternative power control circuit.
(SBM) from Eaton. For use The touch sensitive SBM circuit components.
with multi-module paralleled display shows a graphical Control Area Network (CAN)
9395 systems, the switchgear view of the entire system The Eaton SBM incorporates bus architecture to ensure pre-
enclosure encompasses a one-line diagram, with intuitive the following hallmarks of cise load sharing <3% at full
centralized static switch. controls and quick access to Powerware Hot Sync paralleling system load.
It is orderable with either key information like battery technology, which has defined
Designed with no single
momentary or continuous duty time remaining, event/alarm Eatons most mission-critical
point failure in powertrain
rating, along with system-level history, system metering for UPS configurations for decades:
or control.
circuit breakers for bypass, kW and kVA, voltage, current,
Multiple UPS synchroniza-
UPS system output, feedback frequency, power factor and
tion and load sharing accom-
protection and maintenance, phase balance. The SBM also
plished without dependence
or wrap-around bypass provides terminal connec-
inter-module wiring networks.
functions. Four ratings are tions for system-level building
available as standard: 1200A, alarm inputs and relay outputs.
2000A, 3000A and 4000A. This To enhance flexibility, the
Tie Tie
400
400 kVA
kVA 400 kVA 400 kVA400 kVA or or
Batt
Batt Batt400 kVA
Batt Batt Batt
SBM UPSSBM
Dist
Dist Dist
Dist Dist Dist Output
AC Input AC Bypass
All compo-
nents for
redundant,
multi-module
UPS are
included
Double-conversion
X-Slot Communications
topology converter/
(4 slots)
inverter section
ConnectUPS-X
Web/SNMP Card
8-line
Backlit
LCD
AC Input
Redundant Power
and Output
Supplies
Connections
Top or
Bottom
Entry
Static Bypass
(continuous duty) Input and Output
Contactors
www.eaton.com/9395 1.800.356.5794 10
Technical specifications2
General characteristics
UPS rating (0.9 power factor) Control panel (LCD) 8 lines x 40 characters
kVA 225 275 450 500 550 650 750 825 1000 1100 Battery startup Standard
kW 202 250 405 450 500 585 675 750 900 1000 Frequency conversion Standard
Multi-language Standard
General characteristics Building alarm inputs 5 (galvanic isolated)
Efficiency >94%
Parallel capability 4 distributed, 32 with SBM Options
Max modules per size Up to 3 modules, 550 kVA, up to 4 modules, 825/1100 kVA External maintenance bypass
Audible noise <76dBA @ 1 meter PDU, RPP, and STS
Altitude (max) 2000m at 40C (104F) Maintenance bypass module, matching cabinet, 2/3/4 breaker
N+1 redundancy capable Yes DC disconnects
Field upgradeable Yes 65 or 100 kAIC input breakers
System bypass module Included
Certifications
Input characteristics Safety UL1778, cUL
Voltage 480V standard; and 400V available EMC IEC 62040-2, EN50091 Class A (restricted access)
Voltage range +10% / -15%
Frequency range 45-65 Hz eNotify remote monitoring
Power factor 0.99 (minimum) 7x24 remote monitoring of UPS and battery alarms, daily heartbeat check
Input current distortion <3.5% (no input filter required) and monthly report. eNotify requires the ConnectUPS-X Web/SNMP Card and
Environmental Monitoring Probe.
Soft start capability Yes
Internal backfeed Yes
protection
Communications
Software compatibility: Power Xpert
Output characteristics Communications cards: Four communication bays standard. The following connectivity
Voltage 480V standard; and 400V available options can be installed at any time:
- ConnectUPS-X Web/SNMP Card (included)
Regulation 1% - ModBus RTU card
Inverter PWM with IGBT switching - AS/400 Relay card
- Industrial Relay card
Voltage THD <2% (100% linear load); <5% (non-linear load)
- Powerware HotSync CAN Bridge card
Load power factor range Up to a .9 power factor leading without derating - Environmental Monitoring Probe (included)
- Modem card
Battery Remote inputs/outputs: Five building alarm inputs and one summary alarm contact
(5A @ 120V) standard
Battery types VRLA, AGM, Gel, Wet Cell
Remote monitor panel: Eight backlit status indicator lamps plus an audible horn
Battery voltage 480V
1. Due to continuing improvements, specifications are subject to change without notice.
Temperature compensation Optional 2. Please refer to Eaton 9395 technical documents for specific configuration guidelines and features.