Вы находитесь на странице: 1из 3

EDS / EFS Series Cl. I. Div.

1 & 2, Groups B*, C, D Explosionproof 4C


Cl. II, Div. 1, Groups E, F, G Dust-Ignitionproof
Control Stations Cl. II, Div. 2, Groups F, G Raintight
DSD Cover and Device Cl. III Wet Locations
Sub-assemblies NEMA 3, 7B*CD, 9EFG

For use with EDSCM modular control device


bodies see page519 and EDS/EDSC back Standard Finishes:
boxes. b)HUDOR\HOHFWURJDOYDQL]HGDQG
aluminum acrylic paint
b&RSSHUIUHHDOXPLQXPQDWXUDO
Features:
b/DUJHPDFKLQHVFUHZVIRUIDVWHQLQJ
covers to bodies
b/RFNRXWKROHIRUSDGORFNKDYLQJ1/4
hasp is provided when used with covers
IRUIURQWOHYHUDQGVLGHURFNHUW\SH
operation Options:
b/RFNRXWSURYLVLRQVRQIURQWRSHUDWHG 7KHIROORZLQJVSHFLDORSWLRQVDUHDYDLODEOHE\DGGLQJVXIIL[WR&DWb
pushbutton (marked STOP and OFF) Description Suffix
and all selector switch covers b/RFNRXWSURYLVLRQRQIURQWRSHUDWHGSXVKEXWWRQFRYHU VWDQGDUGRQEXWWRQV
b)RUFRYHUVZLWKIURQWOHYHUDQGVLGH marked STOP and OFF)....................................................................................... S153
b7KUHHSRVLWLRQVHOHFWRUVZLWFKHVZLWKPRGLILHGRSHUDWLRQ

4C
rocker type operating handles, threaded
W\SHVKDIWVDQGEXVKLQJVDUHXVHGWR Momentary contact clockwise operation, spring return to center, maintained
HQVXUHIODPHWLJKWQHVV contact counter-clockwise operation....................................................................... S634
b$FFXUDWHO\JURXQGIODQJHIRUIODPHWLJKW Momentary contact counter-clockwise operation, spring return to center,
MRLQWZKHQPDWHGZLWKJURXQGIODQJHRQ maintained contact clockwise operation.................................................................. S635
back box b0RPHQWDU\UHGHPHUJHQF\6723EXWWRQIURQWRSHUDWHGPXVKURRPEXWWRQ
EUHDNVQRUPDOO\FORVHGFRQWDFWVRQO\ '/OHJHQGSODWHLQFOXGHGPXVWVSHFLI\
legend text)................................................................................................................ S111
Certifications and b%RGLHVDQGFRYHUVFRSSHUIUHHDOXPLQXP SA
Compliances: b)RU9'&RSHUDWLRQRQSLORWOLJKWV S300
b0DLQWDLQHGUHGHPHUJHQF\6723EXWWRQZLWKORFNRXWIURQWRSHUDWHG
(When used with EDSCM & EDS bodies):
mushroom button breaks normally closed and makes normally open contacts
b1(&&(& SXVKWRVWRS ORFNRXWVWDQGDUG ZLOOQRWILWZLWKDSLORWOLJKWLIWUDQVIRUPHULV
Class I, Division 1 & 2, Groups C, D required)..................................................................................................................... S769
Class I, Division 2, Groups B, C, D b6SULQJUHWXUQWRFHQWHUIURPULJKWDQGOHIW )RU'(9RU'(9RQO\  S842
Class II, Division 1, Groups E, F, G b.H\2SHUDWHGUHPRYDEOHIURPDOOSRVLWLRQVS847 K1
b.H\2SHUDWHGUHPRYDEOHIURPOHIWSRVLWLRQIRU'(9RUIURPFHQWHUIRU'(9
Class II, Division 2, Groups F, G
DQG'(9S847 K2
Class III b.H\2SHUDWHGUHPRYDEOHIURPULJKWSRVLWLRQIRU'(9RUIURPOHIWIRU'(9
b1(0$((0$&% 'LY &'()* DQG'(9S847 K3
b8/6WDQGDUGV b.H\2SHUDWHGUHPRYDEOHIURPULJKWSRVLWLRQIRU'(9DQG'(9S847 K4
b&6$6WDQGDUG&1R

3XVKEXWWRQV3LORW/LJKWV 6HOHFWRU Ordering Information:


Switches (when used with EFS bodies):
b1(&&(&
Manual Motor Starters
Class I, Division 1 & 2, Groups B, C, D Poles Max. H.P. Max. Volts A.C. Cat.#
Class II, Division 1, Groups E, F, G With Allen-Bradley Bulletin 600 Switches
Class II, Division 2, Groups F, G 1 1  DSD910
2 1  DSD911
Class III
With General Electric Switches
b1(0$((0$&%&'()*
1 1  DSD912
b8/6WDQGDUG 2 1  DSD913
b&6$6WDQGDUG&1R
With Cutler-Hammer Switches
1 1  DSD914
Standard Materials: 2 1  DSD915
b&RYHUVIURQWRSHUDWHG)HUDOR\LURQ With Arrow-Hart Switches
DOOR\DQGFRSSHUIUHHDOXPLQXP Without Overload Protection
b&RYHUVVLGHRSHUDWHGFRSSHUIUHH 2 5  $ DSD916
aluminum 2 7.5  $ DSD916
b6KDIWVDQGVKDIWEXVKLQJVVWDLQOHVV  7.5  $ DSD917
steel  15 600 (20A) DSD917
b5RFNHUKDQGOHVSXVKEXWWRQVDQGJXDUGV :KHQD&36UHFHSWDFOHFRYHUGHYLFHLVXVHGWKHDVVHPEO\PHHWVUHTXLUHPHQWVIRU&ODVV
I, Groups C and D areas only.
W\SHQ\ORQ
b6HDOLQJHQFORVXUHVFRSSHUIUHH * For pushbuttons, pilot lights, & selector switches, use EFS back box with required external
aluminum FRQGXLWVHDOIRULQFKKXEVL]HZLWKLQIHHWIRU&ODVV,'LYLVLRQ*URXS%DSSOLFDWLRQV

CPS delayed action receptacle cover: Additional key lock housings available; please contact Customer Service.
b5HFHSWDFOHKRXVLQJFRSSHUIUHH i$FRPSDUDEOHIDFWRU\VHDOHGFRYHUZLOOILWRQWKH('6&0ERG\('6DQG('6&ERGLHV
aluminum DQGLQERWWRPJDQJRI('6&0DQG('6&0ERGLHV7RRUGHUDGGVXIIL[6WR
catalog number.
b,QVXODWLRQGLDOO\OSKWKDODWH '$3
b&RQWDFWVEUDVV ,QFOXGHVRQHLQWHUFKDQJHDEOHKHDWHU7RVHOHFWKHDWHUVHHSDJHVb
6\PERO ]HUR PD\EHXVHGWRLQGLFDWHKHDWHURPLWWHG

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2016 Eaton


4C EDS / EFS Series Cl. I. Div. 1 & 2, Groups B*, C, D Explosionproof
Cl. II, Div. 1, Groups E, F, G Dust-Ignitionproof
Control Stations Cl. II, Div. 2, Groups F, G Raintight
Cl. III Wet Locations
DSD Cover and Device NEMA 3, 7B*CD, 9EFG
Sub-Assemblies

DSD918 DSD922 DSD933 DSD962 DSD970 CPS152R ENR5201

For use with EDSCM modular control device bodies see page 519 & EFS/EDS back boxes.

Ordering Information
4C

Front Operated Pushbutton Stations Delayed Action Receptacles


600 VAC Heavy Duty, Factory Sealed Factory Sealed
Number of Normal Rating Cat. #
Cover Buttons Position Diagram Cat. # 20 A, 1 HP, 125250 VAC 60 Hertz CPS152R
1 Circuit 20 A, 18 VDC (2 wire, 3 pole)
1 DSD918
Universal
30 A, 11/2 HP, 125250 VAC 60 Hertz; CPS532R
2 Circuits
1 DSD919 7 A, 1/2 HP, 480 VAC, 60 Hertz (2 wire, 3 pole)
Universal
30 A, 3 HP, 125250 VAC 60 Hertz; CPS732R
2 Circuits DSD920 7A, 1 HP, 480 VAC, 60 Hertz (3 wire, 4 pole)

2 Circuits General Purpose, Dead Front


2 DSD921 Factory Sealed
Universal
2 Circuits
Rating Cat. # Diagram
Start-Stop
2 unless DSD922
otherwise
20 A, 125 VAC ENR5201
specified 5-20R
2 Circuits
2 Universal DSD970 20 A, 250 VAC ENR6202
Mushroom Head 6-20R
3 Circuits
3 (2-operator) DSD962 If desired, markings on indicating plates may be added to catalog
Universal
number. Select from the list of standard markings below:
3 Circuits START OFF RESET LIGHT ON
3 (3-operator) DS511 SA
Universal STOP RUN TRIP HAND
3 Circuits ON JOG TEST AUTOMATIC
EMERGENCY OPEN DOWN RAISE
Universal
FORWARD CLOSE IN LOWER
3 (3-operator) Double pilot light - DS513 SA
REVERSE UP OUT
single pushbutton
combo * For pushbuttons, pilot lights, & selector switches, use EFS back box with required external
conduit seal for 1 inch hub size, within 5 feet for Class I, Division 1, Group B applications.
3 Circuits When a CPS receptacle cover device is used, the assembly meets requirements for Class
Universal I, Groups C and D areas only.
3 (3-operator) Double pushbutton - DS514 SA Two universal contact blocks, must be wired as two circuits with one normally open and
one normally closed. 1 green button, 1 red button, and lockout provision provided as
single pilot light standard.
combo 16 Amp., 125V.
10 Amp., 250V.
Front Operated General Use Snap Switch To order a comparable factory sealed cover for EDS, EDSC, EDSCM21 and the bottom
gang of EDSCM33 and EDSCM63 bodies, add suffix S697. Factory sealed for Class I,
Amperes Division 2, Group B.
Style 120 VAC 277 VAC Cat. # Cannot be factory sealed.
Can only be used with EFD Series 11/ 2 gang back boxes. Pushbuttons include contact
1-Pole 20 20 DSD933 blocks. Standard pushbutton color is black. For optional colors - red, green - write in
2-Pole 20 20 DSD934 color. Example: DS511 GREEN BLACK RED-SA. First color is for uppermost button. For
optional legend markings write in marking after device operator color. Example: DS513-J3
3-Pole DSD935
JOG-J1 STOP GREEN-SA.
3-Way 20 20 DSD936
4-Way 20 20 DSD937
1-Pole 30 30 DSD939
2-Pole 30 30 DSD940
3-Way 30 30 DSD941

522 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2013 Eatons Crouse-Hinds Business
EDS / EFS Series Cl. I. Div. 1 & 2, Groups B*, C, D Explosionproof 4C
Cl. II, Div. 1, Groups E, F, G Dust-Ignitionproof
Control Stations Cl. II, Div. 2, Groups F, G Raintight
Cl. III Wet Locations
DSD Cover and Device NEMA 3, 7B*CD, 9EFG
Sub-Assemblies

Pilot Light Devices


Factory Sealed
Description Diagram Cat.#
With one pilot light DSD948
With two pilot lights (Not
available with a transformer) DSD947
With one pilot light
and transformer DSD948
With one pilot light
DSD951 DSD925 DSD947-J1-J1 and pushbutton station DSD958
With one pilot light
and 1 double pushbutton station DSD961
With one pilot light & transformer
and 1 double pushbutton station DSD961
Triple pilot light DS512 SA
Double pilot light - single

4C
pushbutton combo DS513 SA
Double pushbutton - single
pilot light combo DS514 SA
DSD958 DSD957 DSD961-J1 With one pilot light & 2 position
For use with EDSCM modular control device bodies see page519 & selector switch, two circuit (pos. 1 - DSD973
EFS/EDS back boxes. N.O., pos. 2 - N.C.)
With one pilot light & 2 position
selector switch, four circuit (pos. 1 - DSD974
Ordering Information N.O., pos. 2 - N.C. for both switches)
Side Operated Pushbutton Station With one pilot light & 3 position
selector switch, two circuit (pos. 1 - DSD975
600 VAC Heavy Duty, Factory Sealed N.O., pos. 2 - open, pos. 3 - N.C.)
Normal Position Diagram Cat.# With one pilot light & 3 position
selector switch, four circuit (pos. 1 -
N.O., pos. 2 - open, pos. 3 - N.C. for DSD976
1 Circuit Universal DSD949 both switches)
With one pilot light & 3 position
2 Circuits Universal DSD950 selector switch, four circuit (pos. 1 -
N.C., pos. 2 - N.O., pos. 3 - N.O. for
2 Circuits
switch A; pos. 1 - N.O., DSD977
pos. 2 - N.O., pos. 3 - N.C.
1 Open - A for switch B)
1 Closed - B DSD951
Start-Stop unless Blank Cover
otherwise specified
Description Cat.#
Blank Cover DSD957
Selector Switches Add color symbol for each pilot light from table below.
Maintained Contact 600 VAC Heavy Duty, Factory Sealed
Color Symbol Color Symbol Color Symbol
Style Position 1 Position 2 Position 3 Cat. # Red J1 Amber J6 Blue J11
Two Green J3 Clear J10
Circuit
DSD923 Add suffix below for transformer primary voltage:
Transformers Voltages above 125
Two
Position Four Nom. Volts 5060Hz Primary Voltage
Circuit
DSD924 Transformer Range Suffix
220 / 110 220240 T2
440 / 110 440480 T4
550 / 110 550600 T5
DSD925 If desired, markings on indicating plates may be added to catalog
number. Select from the list of standard markings below:
Two START OFF RESET LIGHT ON
Circuit STOP RUN TRIP HAND
DSD926 ON JOG TEST AUTOMATIC
Three OPEN DOWN RAISE
EMERGENCY
Position FORWARD CLOSE IN LOWER
REVERSE UP OUT
Four Specify indicating plate markings. Standard indicating plate
Circuit
DSD927 markings available are as follows:
Two-Position
RUN, JOG FAST, SLOW IN, OUT
* For pushbuttons, pilot lights, & selector switches, use EFS back box with required external OPEN, CLOSE RAISE, LOWER
conduit seal for 1 inch hub size, within 5 feet for Class I, Division 1, Group B applications.
HAND, AUTOMATIC
LED pilot lights can be furnished in place of standard incandescent pilot lamps. Add suffix FORWARD, REVERSE UP, DOWN START, STOP
LED to Cat. No. after last color symbol. ON, OFF
Can only be used with EFD Series 11/ 2 gang back boxes. Pushbuttons include contact Three-Position
blocks. Standard pushbutton color is black. For optional colors - red, green - write in JOG, OFF, RUN 1, OFF, 2
color. Example: DS511 GREEN BLACK RED-SA. First color is for uppermost button. For AUTOMATIC, OFF, HAND OPEN, OFF, CLOSE
optional legend markings write in marking after device operator color. Example: DS513-J3 FORWARD, OFF, REVERSE UP, OFF, DOWN
JOG-J1 STOP GREEN-SA. FAST, OFF, SLOW

www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2014 Eatons Crouse-Hinds Business

Вам также может понравиться