Вы находитесь на странице: 1из 2

Roll No...

(Paper name) (CE-301-F)


Rawal Institute of Engineering and Technology Time:2 hrs Max. Marks--50
I Mid Term Examination, October 2017 Note: Question no: 1 is compulsory. Attempt any two questions from
B .Tech (Civil, 5th Sem) Q2, Q3,Q4
(Paper name) (CE-301-F) Q1 Answer the following questions: (10x1)
Time:2 hrs Max. Marks--50 k) What is meant by pitch, edge distance & gauge distance?
Note: Question no: 1 is compulsory. Attempt any two questions from l) Explain types of bolted joint with sketches.
Q2, Q3,Q4 m) What are advantages of bolted connections?
n) What are the advantages of HSFG bolts?
Q1 Answer the following questions: (10x1)
o) Write short notes on shear lag effects.
a) What is meant by pitch, edge distance & gauge distance? p) What is laterally supported beam?
b) Explain types of bolted joint with sketches. q) What are the various types of bolts used for structural purposes?
c) What are advantages of welded connections? r) What is prying action?
d) What are the advantages of HSFG bolts? s) What are main failure modes of beam?
e) Write short notes on shear lag effects. t) State the functions of lacing & battening?
f) What is laterally supported beam?
g) What are the various types of bolts used for structural purposes?
h) What is prying action? Q2 Attempt both questions: (2x10=20)
i) What are main failure modes of beam?
j) State the functions of lacing & battening. c) Design the Lap joint for the plates of sizes 100 16 mm and
100 10 mm thick connected so as to transmit a factored load
Q2 Attempt both questions: (2x10=20)
of 100 KN using single row of 16 mm diameter bolts of grade
a) Design the Lap joint for the plates of sizes 100 16 mm and 4.6 and plate of 410 grade. Draw the sketch of connection.
100 10 mm thick connected so as to transmit a factored load d) Two plates of 6 mm thick are connected by single bolted 4 mm
of 100 KN using single row of 16 mm diameter bolts of grade thick double cover butt joint using M20 bolts at 60 mm pitch;
4.6 and plate of 410 grade. Draw the sketch of connection. steel grade 410 MPa and bolts 4.6 grade; Calculate bolt
b) Two plates of 6 mm thick are connected by single bolted 4 mm efficiency.
thick double cover butt joint using M20 bolts at 60 mm pitch;
steel grade 410 MPa and bolts 4.6 grade; Calculate bolt Q3 Attempt both questions: (2x10=20)
efficiency.
a) A tie member of a roof truss consists of 2Nos of ISA
Roll No... 100x75x8mm. The angles are connected to either side of a
Rawal Institute of Engineering and Technology 10mm thick gusset plate and the member is subjected to a
I Mid Term Examination, October 2017
B .Tech (Civil, 5th Sem)
working pull of 300KN. Design the welded connection. working pull of 300KN. Design the welded connection.

Assume the connections are made in the shop. c =31 mm Assume the connections are made in the shop. c =31 mm
b) Design a suitable longitudinal fillet weld to connect the plates d) Design a suitable longitudinal fillet weld to connect the plates
as shown in fig. below. The pull to be transmitted is equal to as shown in fig. below. The pull to be transmitted is equal to
the full strength of the small plate. Given the plates are 12mm the full strength of the small plate. Given the plates are 12mm
thick, grade of plates is Fe410 and welding is made in the thick, grade of plates is Fe410 and welding is made in the
factories. factories.

Q4 Attempt both questions: (2x10=20) Q4 Attempt both questions: (2x10=20)


a) Design a laced column 9 m long to carry a factored axial load c) Design a laced column 9 m long to carry a factored axial load
of 1200 KN. The column is fixed at both the ends. Provide of 1200 KN. The column is fixed at both the ends. Provide
single lacing system with bolted connections. The column single lacing system with bolted connections. The column
consists of two channels placed back to back. consists of two channels placed back to back.
b) Design a built-up column 9 m long to carry a factored axial d) Design a built-up column 9 m long to carry a factored axial
load of 1100 KN. The column is restrained in position but not load of 1100 KN. The column is restrained in position but not
in direction at both the ends. Design the column with in direction at both the ends. Design the column with
connecting system as battens with bolted connections. Use connecting system as battens with bolted connections. Use
channel sections placed back to back. Use steel of grade Fe channel sections placed back to back. Use steel of grade Fe
410. 410.

Q3 Attempt both questions: (2x10=20)

c) A tie member of a roof truss consists of 2Nos of ISA


100x75x8mm. The angles are connected to either side of a
10mm thick gusset plate and the member is subjected to a

Вам также может понравиться