GENERAL NOTES:

FIRST FLOOR D-2 Side view FIRST FLOOR D-2 Top view FIRST FLOOR D-2 Side view
scale 1:20 scale 1:20 1. ALL DIMENSIONS ARE IN MMS UNLESS
scale 1:20
OTHERWISE NOTED.
2. ALL MAIN CONNECTIONS BETWEEN BEAMS
ANGLE CLEAT L4''X4''X0.5''
AND COLUMNS SHALL BE BOLTED AS PER
HOLES ARE 22.2MM DIA DESIGNER RECOMMENDATION FOR
STRUCTURES SUBJECTED TO VIBRATIONS
FROM INSTALLED ROTATING EQUIPMENT AS
PUMPS OR COMPRESSORES.
3. ALL BOLTS HIGH STRENGTH FRIVTION GRIP
BOLTS IN ACCORDANCE WITH AISC A325.
ALL WASHERE ARE PER AISC.
4. USING IMPACT GUN WITH STANDARD
TORQUE MACHINE FOR SNAG TIGHT.
5. ALL HOLES ARE 3MM GREATER THAN BOLT
DIAMETER OR 81 INCH.
6. ALL ANGEL CLEAT HOLES CAN BE
STAGGERED FOR EASY ERECTION PURPOSE
WHERE APPLICABLE. THIS IS FOR IMPACT
GUN SOCKET INSERTION.
7. BOLT EQUIVALENT DIAMETER:
16MM = 85 INCH
20MM= 43 INCH
22MM= 87 INCH
24MM= 1 INCH
8. ALL WELDING WORK SHALL CONFORM TO
AWS D1.1.
9. ALL WELDS ARE STRUCTURAL WELD E60XX
FIRST FLOOR D-2 Isometry SW 1#50 1:50 AND E70XX. QUALIFIED WELDERS AND
WELDING PROCEDURE TO BE PREPARED
PRIOR TO INSTALLATION.
10. ALL HORIZONTAL FLOOR BRACING ARE
WELDED TO GUSSET PLATES BY 4MM SIZE
FILLET WELD TO BEAM WEB.
11. ALL BOLTS HOLES SHALL BE REAMED TO
REMOVE ANY EXCESS COATING BUILD UP.
12. MINIMUM ANGLE CLEAT THICKNESS AND
GUSSET PLATES IS 10MM UNLESS NOTED
OTHERWISE
13. FOR BEAM TO COLUMN WEB CONNECTIONS
ON BOTH SIDES, IT IS RECOMMENDED TO
INSTALL TEMPORAIRLY SUPPORT FOR FIRST
BEAM ERECTION BOLTS.
14. ALL STEEL TO BE CLEANED WITH
COMPRESSED AIR AND EPOXY PRIME
COATING BEFORE INSTALLATION. ANY
DAMAGE TO PAINT SHALL BE REPAIRED BY
TOUCH UP PAINT.