Considere que se tienen celdas solares de silicio cristalino con las siguientes caractersticas
elctricas Vca= 0.62 V, Icc= 8.82 A, Vmp= 0.5 V, Imp= 8.1 A, con dimensiones de 1.56
x 1.56 m.
8.1 0.5
= = = 0.74
8.82 0.62
c) Eficiencia de la celda
= 1.56 1.56 = 0.0243 2 = 1000 2
4.05
= =
1000 2 0.0243 2
= . %
() = # () = 36 0.62 = 22.32
() = # () = 36 0.5 = 18
() = () = 8.1
() = () = 8.82
() = = 0.74
() = () ()
() = 8.1 18
() = .
() = .
() 145.8
() = = = 16.28 %
() 1000 0.89 2
2
i) Si los coefientes de temperatura son:
% % %
= 0.02 , = 0.36 , = 0.45
Octavio Gmez Montero
= 25
= 45
= 920
2
20
= + 1 1 =
800
2
45 20 1
1 = = 0.03125
800 2
1
= 31 + 0.03125 920 2
= .
= = 59.75 C - 25 C = 34.75 C
Con se pueden calcular los parmetros elctricos del mdulo (MFV) @ G= 10002
(@ ) = () (1 + )
100
%
0.36 (34.75 )
(@ ) = 22.32 (1 ) = 19.53
100 %
Octavio Gmez Montero
(@ ) = () (1 + )
100
%
0.02 (34.75 )
(@ ) = 8.82 (1 + ) = 8 .87
100 %
l) Perdidas de Potencia @ Tc
(@ ) = () (1 + )
100
%
0.45 (34.75 )
(@ ) = 145.8 (1 ) = 123.05
100 %
%
= 0.45
ln( )
(@ ) = () (1 + )
ln( ) 100
%
ln 920 2 0.45 (34.75 )
(@ ) = 18 (1 ) = 14.99
100 %
ln 1000 2
Octavio Gmez Montero
(@ ) = (@ ) (@ )
Despejando (@ ) obtenemos:
(@ ) 123.05
(@ ) = = = 8.2
(@ ) 14.99
El del arreglo fotovoltaico (14 MFV en serie) @ STC est dado por:
() = # () = 14 22.32 = 312.48
() = # () = 5 8.82 = 44.1
El del arreglo fotovoltaico (14 MFV en serie) @ STC est dado por:
() = # () = 14 18 = 252
() = # () = 5 8.1 = 40.5
Octavio Gmez Montero
El del arreglo fotovoltaico (14 MFV en serie 1 cadena) est dado por:
(@ ) = # (@ ) = 14 14.99 = 209.86
(@ ) = # (@ ) = 5 8.2 = 41