Bruno Franchi
MB
Consultores
Agenda
Introduo
Problemas
Tpicos
Roteiro
de
Inspeo
Estudo
de
Caso
Concluses
Agenda
Introduo
Problemas
Tpicos
Roteiro
de
Inspeo
Estudo
de
Caso
Concluses
Introduo
Tanques
de
acido
sulfrico
representam
importantes
fatores
de
risco
em
funo
do
potencial
impacto
de
acidentes
e
danos
ao
meio
ambiente
Acidente
Famoso:
IMC
1975
Introduo
Problemas
Tpicos
Roteiro
de
Inspeo
Estudo
de
Caso
Concluso
Problema
por
Acmulo
de
Hidrognio
Problema
por
Acmulo
de
Hidrognio
Ref.
NACE
SP0294-2006
150 mm (6.0 in.)
minimum if used
without dip tube
Note: measure Tank roof
SP0294-2006 from intersection of
center of nozzle
and middle of
Top inlet; see Figure Vent Top Manway plate. If a dip tube
C6a and C6b is used, the nozzle
Roof-to-shell joint; may project 25 mm
see Figure C7 (1.0 in.) into the
tank.
Overflow
Support guide
Dip tube
Wear plates;
see Figure C1 For alloys see
Side outlet;
Table B1
see Figure C1
Side manway For dip tube details
See Figure C2
see Figures C1 and
C4
Shell-to- Dip tube with approximately
bottom joint
25 mm (1.0 in.) diameter
siphon break holes, at least
two, directed toward center
of tank
Bottom outlet; see
Figures C8 and C9
Notes:
1. All top nozzles shall project at least 25 mm (1.0 in) into tank if there is a dip tube and 150 mm (6.0 in.) if no dip tube. The top
inlet projection shall be in accordance with Figures C6a and C6b and Paragraph 3.2.1.
2. Skirt around bottom to keep water from penetrating under tank is optional.
3. Shell-to-bottom joint shall be full penetration welds.
4. All welds below liquid level shall be full penetration welds.
FIGURE C6a
5. All horizontal shell nozzles should have visors on top 180; see Paragraphs 3.5.2 and 3.5.3 and Figure C2 for additional Top Inlet Nozzle
details.
6. Dip tube shall have a support guide to prevent lateral movement. Guide may attach to floor or shell, see Paragraph 3.2.2.
FIGURE C4
Vertical Tank
Sada de ar
Espao p/
instalao
de demister
(opcional)
Entrada de cido
Recheio
cermico
Bocal do
tanque
Introduo
Problemas
Tpicos
Roteiro
de
Inspeo
Estudo
de
Caso
Concluses
Frequncia
de
Inspeo
Recomendada
Ref.
NACE
SP0294-2006
Roteiro
de
Inspeo
Anlise de
Inspeo Material e Relatrio
Estabelecer Trabalhos
do Verificao Final
Frequencia Preparatrios
Tanque Mecnica do de Inspeo
de Inspees
Limpeza Tanque
de Tanque
Introduo
Problemas
Tpicos
Roteiro
de
Inspeo
Estudo
de
Caso
Concluses
Estudo
de
Caso
Vale
FerHlizantes
(CUB
2)
Introduo
Problemas
Tpicos
Roteiro
de
Inspeo
Estudo
de
Caso
Concluses
Concluses
Tanques
de
estocagem
de
acido
sulfrico
requerem
ateno
especial
para
minimizar
situaes
de
risco
evitveis
Chemetics
Anotrol
Unidade Remota
Proteo
Andica
93% Acido
Sulfurico @ 25C
ft. Eficiencia
20 11.1 mpy 2.6 mpy
ft.
10 10 mpy
10.5 mpy
2.2 mpy
2.3 mpy
ft. 9.9 mpy 2.2 mpy
Proteo
Andica