No. D A T E R or ALT P L A N R E C O R D
1 Nov,26,2015 - DRAWN FOR S.NO. 2300
DRAWING NO.
MR7-NH5501F
2 July,27,2016 R1A0 Revised as build
R
ALT
0
All rights reserved. The documents/drawings contain
MHI proprietary information and are legally
protected under the applicable laws.
No reproduction, publication or distribution as a
whole or a part to any third party shall be allowed
without the prior written consent of MHI.
FINISHED PLAN
IMO 9636955
APPROVED CLASS GL
12300 MR7-NH5501F 1 0
1. Classification society : GL
3. Ambient conditions
The ships machinery systems are dimensioned for the following ambient conditions.
If not otherwise stated in the specific chapters.
Air
Machinery spaces max. +45
4.Scope of supply
OUTLINE
DEFOURON is the system to fit block-shaped electrodes of Cu and Al alloy in the
electrolytic cell into which the seawater shall be flowed and to generate Cu-ions and
colloidal Al-compounds through electrolysis.
Through dosage of these Cu-ions and Al-compounds into interior of sea chest and seawater
piping system, anti-fouling films of Cu-ions and anti-corrosive films of Al-compounds shall
be formed, thus enabling to achieve prevention of adherence of marine creatures and at the
same time, to curb corrosion on seawater pipings.
Asbestos is not used in this system.
1. PARTICULARS
1-1. Type DEFOURON, Type:CAOC-26
1-2. Sea Water Flow to be treated 4,100 m3/h (Design of anode life time)
MAX.6,200 m3/h (Design of anode controller)
Refer to table 1,2
2. SPECIFICATION
2-1. Power Supply System
(a) Type and Quantity F220035, 2 units(FWD and AFT)
(b) Input AC 230V, 1, 50Hz
(c) Output DC 20V-35A
(d) Rating Class A, Continuous (by JEC-178)
(e) Rectification System Center Tap
(f) Protective Enclosure IP-44
(g) Dimensions 470(W)1,350(H)400(D) mm
(h) Weight abt. 120 kg
2-3. Differential Pressure Type Flow Meter for Inlet (F1, F1)
(a) Size and Quantity JIS 5K-65A, 2 sets
(b) Flow Range 8.040.0 (Interlocked set 12.0) m3/h
(C) Capacity of Electric Contactor 1C, AC/DC 250V-5.0A
2-4. Differential Pressure Type Flow Meter for Distribution (F2, F2)
(a) Size and Quantity JIS 5K-65A, 2 sets
(b) Flow Range 8.040.0 m3/
3. SCOPE OF SUPPLY
3-1. By Shipyard
(a) Pipe materials and works 1 lot
(b) Wire materials and works 1 lot
(c) Valve material and works 1 lot
(d) Installation work of DEFOURON 1 lot
(e) Running Test 1 lot
3-2. By NCE
(a) Materials All Components of Item 2
(b) Shop Test 1 lot
Confidential S.No.2300 (MR7-NH5501F_R1A0) 6/25
Table-1
DEFOURON OPERATION PLAN (FWD MAIN ENGINE COMPARTMENT)
PUMP NAVIGATION
SEA CHEST PUMP NAME CAPACITY
MAX.( 1) N. S. G.( 2) PORT
(m3/h)
No.1&2 MAIN
2,200 2,200 1,350 950
COOL.S.W.PUMP
No.1 RO PLANT S.W.
156 156 156
SUPPLY PUMP
Table-2
DEFOURON OPERATION PLAN (AFT MAIN ENGINE COMPARTMENT)
PUMP NAVIGATION
SEA CHEST PUMP NAME CAPACITY
MAX. N. S. G.( 2) PORT
(m3/h)
No.3&4 MAIN
1,500 1,500 1,320 700
COOL.S.W.PUMP
No.2 RO PLANT S.W.
156 156 156
SUPPLY PUMP
M
G
P
S
S
W
S
U
P
P
L
Y
P
U
M
P
DEFOURON
SEA CHEST BP 15
ER DK0 POWER P.SIDE(LOW)
SUPPLY DC OUTPUT
(P,N: - ) 3x6mm2
ANODE COMSAMPTION SIG, LIST OF NCE SUPPLY
AC 230V,1,50Hz
MB-4 2x1.5mm2 (Ter3:Cu SIG AND Al SIG,Ter4:SIG - )
1x2x0.75mm 2 No. NAME STANDARD Q'TY
air vent
1 POWER SUPPLY F220025 1UNIT
65A
F2 2 ELECTROLYTIC CELL CAOC-26 1UNIT
5K-65A 5K-65A 65A
ELECTROLYTIC CELL JIS 5K-65A
3 FLOW METER FOR INLET (F1) 840 m /h3 1SET
(CAOC-26)
JIS 5K-65A
4 FLOW METER FOR DISTRIBUTION (F2) 840 m 3 /h 1SET
5K-40A AIR INJECTION COPPER BLOCK 16PCS
P1 5 Cu ELECTRODE
ER DK0 NOZZLE for
MALSE
320x320xt10 mm (1
ALUMINIUM BLOCK
charge/y)
8PCS
6 Al ELECTRODE 320x320xt20 mm (1 charge/y)
65A
F1 BP
P2 2
1 Dec.13,2012 Revised according to the shipyard's comment S.MINABE
INTERLOCKED
P3 NO DATE DESCRIPTION CHECKED BY
1x2x0.75mm2 FOR
P4
TITLE
PIPING DIAGRAM FOR DEFOURON
(FWD MAIN ENGINE COMPARTMENT)
CAUTION! SCALE NONE DATE Jul.19,2012
(1) Keep the voltage drop in the cable for DC output to max,
1.0V between power supply and electrolytic cell. APPROVED BY H.SHIMONO DESIGNED BY S.MINABE
(2) The interlock wiring shall made between the differential
pressure type flow meter at the entrance side of electrolytic CHECKED BY T.TUCHIKURA DRAWN BY S.MINABE
cell and the main unit (power source).
(3) The straight pipe length of more than 10 times its inner diagram SEA CHEST
shall be used immediately before and after the differential S.SIDE(HIGH)
pressure type flow meter.
CAPACITY
No. PUMP NAME
m 3 /h
4x2x0.75mm2
Hard wire P1 No.3&4 MAIN COOL.S.W.PUMP 1,500
IAMCS P2 No.2 RO PLANT S.W.SUPPLY PUMP 156
P3 CCU COOL.S.W.PUMP 1,250
ECR(Running ind.,Current ind & Common alarm) P4 ACU COOL.S.W.PUMP 1,300
M
G
P
S
S
W
S
U
P
P
L
Y
P
U
M
P
BP 15
DEFOURON
SEA CHEST
ER DK0 POWER P.SIDE(LOW)
SUPPLY DC OUTPUT
(P,N: - ) 3x6mm2
LIST OF NCE SUPPLY
ANODE COMSAMPTION SIG,
AC 230V,1,50Hz
MB-5 2x1.5mm2 (Ter3:Cu SIG AND Al SIG,Ter4:SIG - ) No. NAME STANDARD Q'TY
1x2x0.75mm2
air vent 1 POWER SUPPLY F220025 1UNIT
65A
F1' BP
2
1 Dec.13,2012 Revised according to the shipyard's comment S.MINABE
NO DATE DESCRIPTION CHECKED BY
INTERLOCKED
2
P2 FOR
1x2x0.75mm
P3
TITLE
PIPING DIAGRAM FOR DEFOURON
P4
(AFT MAIN ENGINE COMPARTMENT)
CAUTION! SCALE NONE DATE Jul.19,2012
(1) Keep the voltage drop in the cable for DC output to max,
1.0V between power supply and electrolytic cell. APPROVED BY H.SHIMONO DESIGNED BY S.MINABE
(2) The interlock wiring shall made between the differential
pressure type flow meter at the entrance side of electrolytic CHECKED BY T.TUCHIKURA DRAWN BY S.MINABE
cell and the main unit (power source).
(3) The straight pipe length of more than 10 times its inner diagram
shall be used immediately before and after the differential SEA CHEST
pressure type flow meter. S.SIDE(HIGH)
FOR SERVICE
3
120
abt.203
5
FOR SERVICE
78
OUTLET
JIS 5k-65A
8
No. ITEM MATERIAL Q'TY
5 5'
328
Electrolytic Cell Lower Lid SS+Rubber Lining 1
441
9 Electrolytic Cell Top Lid SS+Rubber Lining 1
Top Lid Fixture Pin SS 1
6 6'
Cu Electrode(FOR FWD) SS (320320t10) 16
' Cu Electrode(FOR AFT) SS (320320t10) 14
10
Al Electrode(FOR FWD) SS (320320t20) 8
' Al Electrode(FOR AFT) SS (320320t20) 7
103
1 Attachment Leg SS400 1
INLET SPACER PVC 1
JIS 5k-65A Cathode SS400 1
Hinge Bolt, Eye Nut SS400 8
200
180
DRAIN
JIS 5k-40A
3
180
AFT 550
FWD 700
2
7 350 Aug.5,2013 Revised as per yard's comments T.Tsuchikura
1
NO DATE DESCRIPTION CHECKED BY
FOR()
AFT 350
FWD 500
TITLE
ELECTROLYTIC CELL OUTLINE
Type:CAOC-26
4-19
SCALE NONE DATE Jul.31,2012
FOR SERVICE APPROVED BY H.SHIMONO DESIGNED BY T.TSUCHIKURA
CHECKED BY T.TSUCHIKURA DRAWN BY S.MINABE
200 200 225
THE NIPPON CORROSION ENGINEERING CO.,LTD.
480 280
PARTS LIST
NO. ITEM MATERIAL REMARK Q'TY
200
11 12
120 1 METER BOX AC 1
2 GRADUATED PLATE ACRYLITE 1
3 POINTER PB BLACK & RED 2
18 ADD.BRACKET
4 PLUG PVC PT 1/4 2
55
5 PIPE & ELBOW Cu 8 1S
3 2 17 13 14 15 16 6 BLOCK PVC 2
1 4 7 ORIFICE PLATE PVC 1
H2.5
8 O-RING NEOPRENE 1
5 9 PACKING NEOPRENE 2
H L 10 PIN SUS304 1S
11 TERMINAL BOX AC 1
from to
No. CABLE MAKING characterize
clear text
characterize
clear text
1N004203
1 (1N005104) control unit source
1MGPS101
2 (1MGPS201) control unit inlet flow meter
71M43MGP11
3 (71M53MGP21) control unit IAMCS(alarm signal output)
71M43MGP11
4 (71M53MGP21) control unit IAMCS(running signal output)
71M43MGP11
5 (71M53MGP21) control unit IAMCS(running signal input)
71M43MGP11
6 (71M53MGP21) control unit IAMCS(DC output current signal output)
1MGPS102
7 (1MGPS202) control unit ELECTROLYTIC CELL
1MGPS103
8 (1MGPS203) control unit ELECTROLYTIC CELL
9
10
11
12
13
14
15
SNO.2300/01
External cabling plan for MARINE GROWTH PREVENTION SYSTEM
Approved ref. ; Customer ; DWG Name ; WIRE RUN TABLE OF POWER SYSTEM Plot date ;
AIDA (MACHINERY PART OTHERS)
Contact ; SHIPBUILDING & OCEAN
Class ; Hull ; Spec.No. ; DWG No. ; Sys. Rev. Alt.
DEVELOPMENT GL 2300/01 7.1.14 V28-S001E MGPS
Confidential S.No.2300 (MR7-NH5501F_R1A0) 24/25
DK0 FZ4
MGPS-CP1 No.1 MGPS CONTROL PANEL FWD M/E RM
IAMCS-
L IAMCS SCU CABINET 45 (7IM45MGP11) (TTKS4#)
SCU45
DK0 FZ5
MGPS-CP2 No.2 MGPS CONTROL PANEL AFT M/E RM
IAMCS-
L IAMCS SCU CABINET 57 (7IM57MGP21) (TTKS4#)
SCU57