Вы находитесь на странице: 1из 25

Confidential S.No.

2300 (MR7-NH5501F_R1A0) 1/25

No. D A T E R or ALT P L A N R E C O R D
1 Nov,26,2015 - DRAWN FOR S.NO. 2300

DRAWING NO.
MR7-NH5501F
2 July,27,2016 R1A0 Revised as build

R
ALT
0
All rights reserved. The documents/drawings contain
MHI proprietary information and are legally
protected under the applicable laws.
No reproduction, publication or distribution as a
whole or a part to any third party shall be allowed
without the prior written consent of MHI.

FINISHED PLAN

IMO 9636955

ENGINEERING & DESIGNING DEP. AIDA cruises AIDAprima


CONFERRED
EQUIPMENT DESIGNING GROUP

APPROVED CLASS GL

CHECKED H.YANAGISAWA (TEL 33327) MARINE GROWTH PREVENTION SYSTEM


DRAWN K.IZUMI (TEL 34197)
SCALE

ORDER LIST NO DRAWING NO. R ALT

12300 MR7-NH5501F 1 0

SHIPBUILDING & OCEAN DEVELOPMENT


DRAWN 'Nov,26,2015 ISSUED
Confidential S.No.2300 (MR7-NH5501F_R1A0) 2/25
1

Mitsubishi Heavy Industries , Ltd.

2 Nov.7th,2012 Revised as per shipyards comments


1 Sep.18th,2012 Revised as per shipyards comments
REV DATE DESCRIPTION
DATE Jul. 31,2012

SNo.2300/2301 JOB No. H06BWB1


APPROVED H.SHIMONO
The Specification of Marine Growth Preventing System
DEFOURON Type : CAOC-26 CHECKED A.KOBAYASHI
DRAWN T.Tsuchikura

THE NIPPON CORROSION ENGINEERING CO., LTD. SPEC No. BK1414


NCE SHEET 1/20 REV.2
Confidential S.No.2300 (MR7-NH5501F_R1A0) 3/25

Customer : AIDA Cruises


Ship yard : Mitsubishi Heavy Industries, Ltd.
Nagasaki Shipyard & Machinery Works
Ship s Kind : 121,000 GRT Cruise Vessel

1. Classification society : GL

2. Rule and regulations : JIS,IEC

3. Ambient conditions
The ships machinery systems are dimensioned for the following ambient conditions.
If not otherwise stated in the specific chapters.

Sea water +0 to +32 (in open waters)


+0 to +34 (in port)

Air
Machinery spaces max. +45

4.Scope of supply

.reaction tank with electrodes


.feed flow meter with low flow switch-TOKYO RYUKI KOGYO CO.,LTD.
.distribution flow meter-TOKYO RYUKI KOGYO CO.,LTD.
.control panel with remote monitoring/alarm signal
.manufacturer s standard spare parts and tools including
.electrodes(12 months working/each unit+12months spare/each unit, Total 24months)

5.Particulars of Marine Growth Prevention System


Refer to outline dimension for Marine Growth Prevention System
Confidential S.No.2300 (MR7-NH5501F_R1A0) 4/25
2

OUTLINE
DEFOURON is the system to fit block-shaped electrodes of Cu and Al alloy in the
electrolytic cell into which the seawater shall be flowed and to generate Cu-ions and
colloidal Al-compounds through electrolysis.
Through dosage of these Cu-ions and Al-compounds into interior of sea chest and seawater
piping system, anti-fouling films of Cu-ions and anti-corrosive films of Al-compounds shall
be formed, thus enabling to achieve prevention of adherence of marine creatures and at the
same time, to curb corrosion on seawater pipings.
Asbestos is not used in this system.

1. PARTICULARS
1-1. Type DEFOURON, Type:CAOC-26

1-2. Sea Water Flow to be treated 4,100 m3/h (Design of anode life time)
MAX.6,200 m3/h (Design of anode controller)
Refer to table 1,2

1-3. Color of Main Equipment RAL 6034


Color of Control Panel RAL 7035

2. SPECIFICATION
2-1. Power Supply System
(a) Type and Quantity F220035, 2 units(FWD and AFT)
(b) Input AC 230V, 1, 50Hz
(c) Output DC 20V-35A
(d) Rating Class A, Continuous (by JEC-178)
(e) Rectification System Center Tap
(f) Protective Enclosure IP-44
(g) Dimensions 470(W)1,350(H)400(D) mm
(h) Weight abt. 120 kg

2-2. Electrolytic Cell


(a) Type and Quantity CAOC-26, 2 units(FWD and AFT)
(b) Normal Electrolysis Current FWD ; 020.0A, AFT : 018.0A
(c) Sea Water Flow into Electrolytic Cell abt. 15 m3/h and over
(d) Cu-Ion Generated Max. FWD;12.3 g/hr, AFT;10.4 g/hr
(e) Al-Ion Generated Max. FWD;4.1 g/hr, AFT;3.5 g/hr
(f) Material of Cell Unit Body Steel Inside Plate with Rubber Lining
(g) Dimensions abt. 6201344() mm
(h) Weight abt. 250 kg (Exclude Anodes)
Confidential S.No.2300 (MR7-NH5501F_R1A0) 5/25

(i) Quantity of Electrode


Copper Block FWD320320t10 mm, 16pcs1 charge/year
AFT320320t10 mm, 16pcs1 charge/year
Aluminum Block FWD320320t20 mm, 8pcs1 charge/year
AFT320320t20 mm, 8pcs1 charge/year

2-3. Differential Pressure Type Flow Meter for Inlet (F1, F1)
(a) Size and Quantity JIS 5K-65A, 2 sets
(b) Flow Range 8.040.0 (Interlocked set 12.0) m3/h
(C) Capacity of Electric Contactor 1C, AC/DC 250V-5.0A

2-4. Differential Pressure Type Flow Meter for Distribution (F2, F2)
(a) Size and Quantity JIS 5K-65A, 2 sets
(b) Flow Range 8.040.0 m3/

2-5. Spare Parts See The Spare Parts List

3. SCOPE OF SUPPLY
3-1. By Shipyard
(a) Pipe materials and works 1 lot
(b) Wire materials and works 1 lot
(c) Valve material and works 1 lot
(d) Installation work of DEFOURON 1 lot
(e) Running Test 1 lot

3-2. By NCE
(a) Materials All Components of Item 2
(b) Shop Test 1 lot
Confidential S.No.2300 (MR7-NH5501F_R1A0) 6/25

Table-1
DEFOURON OPERATION PLAN (FWD MAIN ENGINE COMPARTMENT)

PUMP NAVIGATION
SEA CHEST PUMP NAME CAPACITY
MAX.( 1) N. S. G.( 2) PORT
(m3/h)
No.1&2 MAIN
2,200 2,200 1,350 950
COOL.S.W.PUMP
No.1 RO PLANT S.W.
156 156 156
SUPPLY PUMP

HIGH OR LOW CCU COOL.S.W.PUMP 1250 2 2,500 1,250 1,250


SEA CHEST
ACU COOL.S.W.PUMP 1,300 1,300 1,300 -

TOTAL SEA WATER FLOW TO BE TREATED (m3/h) 6,156 4,056 2,200


SEA WATER FLOW INTO CELL (m3/h) 30
OPERATION CURRENT (Amp) 32 22 12
Cu/Al
INJECTION Cu & Al Ion Density (ppm) 0.003/0.001 0.003/0.001 0.003/0.001
1 controller design : 6,200m3/h
2 design life time of electrode :4,100 m3/h
REMARK :
Confidential S.No.2300 (MR7-NH5501F_R1A0) 7/25

Table-2
DEFOURON OPERATION PLAN (AFT MAIN ENGINE COMPARTMENT)

PUMP NAVIGATION
SEA CHEST PUMP NAME CAPACITY
MAX. N. S. G.( 2) PORT
(m3/h)
No.3&4 MAIN
1,500 1,500 1,320 700
COOL.S.W.PUMP
No.2 RO PLANT S.W.
156 156 156
SUPPLY PUMP

HIGH OR LOW CCU COOL.S.W.PUMP 1250 1,250 1,250 1,250


SEA CHEST
ACU COOL.S.W.PUMP 1,300 1,300 1,300 -

TOTAL SEA WATER FLOW TO BE TREATED (m3/h) 4,206 4,026 1,950


SEA WATER FLOW INTO CELL (m3/h) 30
OPERATION CURRENT (Amp) 22 21 11
Cu/Al
INJECTION Cu & Al Ion Density (ppm) 0.003/0.001 0.003/0.001 0.003/0.001
m3/h(See
1 controller design :6,200 FWD UNIT)
2 design life time of electrode :4,100 m3/h
REMARK :
Confidential S.No.2300 (MR7-NH5501F_R1A0) 8/25
4
4x2x0.75mm2 CAPACITY
Hard wire No. PUMP NAME
m 3 /h
IAMCS P1 No.1&2 MAIN COOL.S.W.PUMP 2,200
P2 No.1 RO PLANT S.W.SUPPLY PUMP 156
ECR(Running ind.,Current ind & Common alarm) P3 CCU COOL.S.W.PUMP 1,250
P4 ACU COOL.S.W.PUMP 1,300

M
G
P
S
S
W
S
U
P
P
L
Y
P
U
M
P
DEFOURON
SEA CHEST BP 15
ER DK0 POWER P.SIDE(LOW)
SUPPLY DC OUTPUT
(P,N: - ) 3x6mm2
ANODE COMSAMPTION SIG, LIST OF NCE SUPPLY
AC 230V,1,50Hz
MB-4 2x1.5mm2 (Ter3:Cu SIG AND Al SIG,Ter4:SIG - )
1x2x0.75mm 2 No. NAME STANDARD Q'TY
air vent
1 POWER SUPPLY F220025 1UNIT
65A
F2 2 ELECTROLYTIC CELL CAOC-26 1UNIT
5K-65A 5K-65A 65A
ELECTROLYTIC CELL JIS 5K-65A
3 FLOW METER FOR INLET (F1) 840 m /h3 1SET
(CAOC-26)
JIS 5K-65A
4 FLOW METER FOR DISTRIBUTION (F2) 840 m 3 /h 1SET
5K-40A AIR INJECTION COPPER BLOCK 16PCS
P1 5 Cu ELECTRODE
ER DK0 NOZZLE for
MALSE
320x320xt10 mm (1
ALUMINIUM BLOCK
charge/y)
8PCS
6 Al ELECTRODE 320x320xt20 mm (1 charge/y)

65A
F1 BP

P2 2
1 Dec.13,2012 Revised according to the shipyard's comment S.MINABE
INTERLOCKED
P3 NO DATE DESCRIPTION CHECKED BY
1x2x0.75mm2 FOR

P4
TITLE
PIPING DIAGRAM FOR DEFOURON
(FWD MAIN ENGINE COMPARTMENT)
CAUTION! SCALE NONE DATE Jul.19,2012
(1) Keep the voltage drop in the cable for DC output to max,
1.0V between power supply and electrolytic cell. APPROVED BY H.SHIMONO DESIGNED BY S.MINABE
(2) The interlock wiring shall made between the differential
pressure type flow meter at the entrance side of electrolytic CHECKED BY T.TUCHIKURA DRAWN BY S.MINABE
cell and the main unit (power source).
(3) The straight pipe length of more than 10 times its inner diagram SEA CHEST
shall be used immediately before and after the differential S.SIDE(HIGH)
pressure type flow meter.

DWG NO. BW06-0211-02-F REV. 1 (A4)


Confidential S.No.2300 (MR7-NH5501F_R1A0) 9/255

CAPACITY
No. PUMP NAME
m 3 /h
4x2x0.75mm2
Hard wire P1 No.3&4 MAIN COOL.S.W.PUMP 1,500
IAMCS P2 No.2 RO PLANT S.W.SUPPLY PUMP 156
P3 CCU COOL.S.W.PUMP 1,250
ECR(Running ind.,Current ind & Common alarm) P4 ACU COOL.S.W.PUMP 1,300

M
G
P
S
S
W
S
U
P
P
L
Y
P
U
M
P
BP 15
DEFOURON
SEA CHEST
ER DK0 POWER P.SIDE(LOW)
SUPPLY DC OUTPUT
(P,N: - ) 3x6mm2
LIST OF NCE SUPPLY
ANODE COMSAMPTION SIG,
AC 230V,1,50Hz
MB-5 2x1.5mm2 (Ter3:Cu SIG AND Al SIG,Ter4:SIG - ) No. NAME STANDARD Q'TY
1x2x0.75mm2
air vent 1 POWER SUPPLY F220025 1UNIT

65A 2 ELECTROLYTIC CELL CAOC-26 1UNIT


F2' JIS 5K-65A
5K-65A 5K-65A 3 FLOW METER FOR INLET (F1') 840 m /h3 1SET
ELECTROLYTIC CELL 65A
JIS 5K-65A
(CAOC-26) 4 FLOW METER FOR DISTRIBUTION (F2') 840 m 3 /h 1SET
COPPER BLOCK 16PCS
5 Cu ELECTRODE 320x320xt10 mm (1 charge/y)
5K-40A
P1
ER DK0 6 Al ELECTRODE
ALUMINIUM BLOCK
320x320xt20 mm
8PCS
(1 charge/y)

65A
F1' BP
2
1 Dec.13,2012 Revised according to the shipyard's comment S.MINABE
NO DATE DESCRIPTION CHECKED BY
INTERLOCKED
2
P2 FOR
1x2x0.75mm

P3
TITLE
PIPING DIAGRAM FOR DEFOURON
P4
(AFT MAIN ENGINE COMPARTMENT)
CAUTION! SCALE NONE DATE Jul.19,2012
(1) Keep the voltage drop in the cable for DC output to max,
1.0V between power supply and electrolytic cell. APPROVED BY H.SHIMONO DESIGNED BY S.MINABE
(2) The interlock wiring shall made between the differential
pressure type flow meter at the entrance side of electrolytic CHECKED BY T.TUCHIKURA DRAWN BY S.MINABE
cell and the main unit (power source).
(3) The straight pipe length of more than 10 times its inner diagram
shall be used immediately before and after the differential SEA CHEST
pressure type flow meter. S.SIDE(HIGH)

DWG NO. BW06-0211-02-A REV. 1 (A4)


Confidential S.No.2300 (MR7-NH5501F_R1A0) 10/25
15
620 490
10

FOR SERVICE
3

120

abt.203
5
FOR SERVICE

78
OUTLET
JIS 5k-65A

8
No. ITEM MATERIAL Q'TY
5 5'

328
Electrolytic Cell Lower Lid SS+Rubber Lining 1

2 Electrolytic Cell Body SS+Rubber Lining 1


4

441
9 Electrolytic Cell Top Lid SS+Rubber Lining 1
Top Lid Fixture Pin SS 1
6 6'
Cu Electrode(FOR FWD) SS (320320t10) 16
' Cu Electrode(FOR AFT) SS (320320t10) 14

10
Al Electrode(FOR FWD) SS (320320t20) 8
' Al Electrode(FOR AFT) SS (320320t20) 7

103
1 Attachment Leg SS400 1
INLET SPACER PVC 1
JIS 5k-65A Cathode SS400 1
Hinge Bolt, Eye Nut SS400 8

200

180
DRAIN
JIS 5k-40A
3
180
AFT 550
FWD 700

2
7 350 Aug.5,2013 Revised as per yard's comments T.Tsuchikura
1
NO DATE DESCRIPTION CHECKED BY
FOR()
AFT 350
FWD 500

TITLE
ELECTROLYTIC CELL OUTLINE
Type:CAOC-26

4-19
SCALE NONE DATE Jul.31,2012
FOR SERVICE APPROVED BY H.SHIMONO DESIGNED BY T.TSUCHIKURA
CHECKED BY T.TSUCHIKURA DRAWN BY S.MINABE


200 200 225
THE NIPPON CORROSION ENGINEERING CO.,LTD.
480 280

DWG NO. BW06-0236-08 REV. 1


Confidential S.No.2300 (MR7-NH5501F_R1A0) 11/25
16

PARTS LIST
NO. ITEM MATERIAL REMARK Q'TY
200
11 12
120 1 METER BOX AC 1
2 GRADUATED PLATE ACRYLITE 1
3 POINTER PB BLACK & RED 2
18 ADD.BRACKET
4 PLUG PVC PT 1/4 2

55
5 PIPE & ELBOW Cu 8 1S
3 2 17 13 14 15 16 6 BLOCK PVC 2
1 4 7 ORIFICE PLATE PVC 1

H2.5
8 O-RING NEOPRENE 1
5 9 PACKING NEOPRENE 2
H L 10 PIN SUS304 1S
11 TERMINAL BOX AC 1

6 12 CABLE GLAND 15b 1


13 BODY PVC 1
7 14 BOLT SUS304 16
15 BRACKET SS400 GILDING 1
D

8 16 SUPPORTING BOLT SS400 2


17 U-BOLT,NUT SS400 M10 1
5 18
9 18 BRACKET SPC 2
801.0 10 B2.0
(WITH PACKING)
F1'(AFT) REMARK
F1(FWD)
FLOW
SPECIFICATION TERMINALS OF LIMIT SWITCH 2
1 Aug.5,2013 Revise as per yard's comments T.Tsuchikura
B(mm) H(mm) D(mm) NO DATE DESCRIPTION CHECKED BY
RED
JIS 5K-25A 0.2 1.0 190 260 62 4.9 COM TITLE
DIFFERENTIAL PRESSURE TYPE FLOW METER
25A 0.4 2.0 190 260 62 4.9 WITH LIMIT SWITCH FOR INLET
TO POWER SUPPLY
25A 0.6 3.0 190 260 62 4.9 WHITE (,)
NO
25A 1.0 5.0 190 260 62 4.9
40A 0.6 3.0 190 270 78 5.1 SCALE NONE DATE 2003.10.10
40A 1.2 6.0 190 270 78 5.1 BLACK
40A 2.0 10.0 190 270 78 5.1
NC

APPROVED BY H.SHIMONO DESIGNED BY T.TSUCHIKURA
40A 3.0 15.0 190 270 78 5.1 CHECKED BY T.TSUCHIKURA DRAWN BY K.SHIGEYAMA
LIMIT SWITCH POSITION NOW INDICATES STATUS
50A 5.0 25.0 190 275 88 5.3 OF METER WHERE FLOW INDICATING POINTER
50A 6.0 30.0 190 275 88 5.3 (BLACK) IS POSITIONED AT THE LEFT SIDE
F1,F1' 65A 8.0 40.0 190 285 112 5.5 OF THE SETTING POINTER (RED).
80A 6.0 30.0 190 290 125 5.6
80A 10.0 50.0 190 290 125 5.6
() THE NIPPON CORROSION ENGINEERING CO.,LTD.
()
16.0 80.0 190 300 145 6.1
100A
125A 24.0 120.0 240 320 180 6.8 DWG NO. BW06-0040-01 REV. 1
Confidential S.No.2300 (MR7-NH5501F_R1A0) 12/25
Confidential S.No.2300 (MR7-NH5501F_R1A0) 13/25
Confidential S.No.2300 (MR7-NH5501F_R1A0) 14/25
Confidential S.No.2300 (MR7-NH5501F_R1A0) 15/25
Confidential S.No.2300 (MR7-NH5501F_R1A0) 16/25
Confidential S.No.2300 (MR7-NH5501F_R1A0) 17/25
Confidential S.No.2300 (MR7-NH5501F_R1A0) 18/25
Confidential S.No.2300 (MR7-NH5501F_R1A0) 19/25
Confidential S.No.2300 (MR7-NH5501F_R1A0) 20/25
Confidential S.No.2300 (MR7-NH5501F_R1A0) 21/25
Confidential S.No.2300 (MR7-NH5501F_R1A0) 22/25

from to
No. CABLE MAKING characterize
clear text
characterize
clear text
1N004203
1 (1N005104) control unit source
1MGPS101
2 (1MGPS201) control unit inlet flow meter
71M43MGP11
3 (71M53MGP21) control unit IAMCS(alarm signal output)
71M43MGP11
4 (71M53MGP21) control unit IAMCS(running signal output)
71M43MGP11
5 (71M53MGP21) control unit IAMCS(running signal input)
71M43MGP11
6 (71M53MGP21) control unit IAMCS(DC output current signal output)
1MGPS102
7 (1MGPS202) control unit ELECTROLYTIC CELL
1MGPS103
8 (1MGPS203) control unit ELECTROLYTIC CELL

9
10
11
12
13
14
15

Dec.13,2012 Revised according to the shipyard's comment S.MINABE


Confidential S.No.2300 (MR7-NH5501F_R1A0) 23/25

SNO.2300/01
External cabling plan for MARINE GROWTH PREVENTION SYSTEM

Kind of Terminal Terminal Core Core Terminal Terminal


Remarks
Panel number Signal Description signal Direction of signal strip number number Circuit number Cable type number number strip Panel number
5 1W 1W 2+
COMMON ALARM Digital TO IAMCS
6 1B 1B 2
A206.1
7 2W 2W 3+
RUNNING Digital TO IAMCS
8 2B 2B 3
MGPS-CP1 9 3W 7IM45MGP11 TTKS4# 3W 3 IAMCS-SCU45
RUNNING Analogue FROM IAMCS A211.1
10 3B 3B 6
11 4W 4W 16
DC OUTPUT CURRENT Analogue TO IAMCS A205.1
12 4B 4B 17
- - - - S S - -
5 1W 1W 3+
COMMON ALARM Digital TO IAMCS
6 1B 1B 3
A204.2
7 2W 2W 2+
RUNNING Digital TO IAMCS
8 2B 2B 2
MGPS-CP2 9 3W 7IM57MGP21 TTKS4# 3W 3 IAMCS-SCU57
RUNNING Analogue FROM IAMCS A210.1
10 3B 3B 6
11 4W 4W 12
DC OUTPUT CURRENT Analogue TO IAMCS A207.1
- 12 4B 4B 13
- - - - S S - -
1 1W 1W COM
INLET FLOW METER Digital FROM IFM1 1MGPS101 TTKS1#
2 1B 1B NO
3 1W 1W SENSOR
1MGPS103 TTKS1#
4 1B 1B -
MGPS-CP1 CELL1 Analogue TO CELL1
P BN BN +
1MGPS102 TK6#
N BK BK -
L BN BN
AC230V POWER SOURCE Power FROM L-01-4-3 2L0143E06 DK1#
N BU BU
1 1W 1W COM
INLET FLOW METER Digital FROM IFM2 1MGPS201 TTKS1#
2 1B 1B NO
3 1W 1W SENSOR
1MGPS203 TTKS1#
4 1B 1B -
MGPS-CP2 CELL2 Analogue TO CELL2
P BN BN +
1MGPS202 TK6#
N BK BK -
L BN BN
AC230V POWER SOURCE Power FROM L-01-5-1 2L0151E01 DK1#
N BU BU

Approved ref. ; Customer ; DWG Name ; WIRE RUN TABLE OF POWER SYSTEM Plot date ;
AIDA (MACHINERY PART OTHERS)
Contact ; SHIPBUILDING & OCEAN
Class ; Hull ; Spec.No. ; DWG No. ; Sys. Rev. Alt.
DEVELOPMENT GL 2300/01 7.1.14 V28-S001E MGPS
Confidential S.No.2300 (MR7-NH5501F_R1A0) 24/25

CIRCUIT MARK SNO.2300/01


V21-S001E
27-1/
1MGPS1

MARINE GROWTH PREVENTION SYSTEM (1/2) NAME CIRC.NO. CABLE REMARKS

DK0 FZ4
MGPS-CP1 No.1 MGPS CONTROL PANEL FWD M/E RM

DK1 FZ4 LIGHT. DIST. BOARD


L L-01-4-3 (2L0143E06) (DK1#) AC230V, 11A
(L-01-4-3)

L IFM1 INLET FLOW METER 1MGPS101 TTKS1#

L CELL1 ELECTROLYTIC CELL 1MGPS102 TK6# DC20V, 35A

L SENSOR 1MGPS103 TTKS1#

IAMCS-
L IAMCS SCU CABINET 45 (7IM45MGP11) (TTKS4#)
SCU45

SHIPBUILDING & OCEAN DEVELOPMENT


Confidential S.No.2300 (MR7-NH5501F_R1A0) 25/25

CIRCUIT MARK SNO.2300/01


V21-S001E
27-2/
1MGPS2

MARINE GROWTH PREVENTION SYSTEM (2/2) NAME CIRC.NO. CABLE REMARKS

DK0 FZ5
MGPS-CP2 No.2 MGPS CONTROL PANEL AFT M/E RM

DK1 FZ5 LIGHT. DIST. BOARD


L L-01-5-1 (2L0151E01) (DK1#) AC230V, 11A
(L-01-5-1)

L IFM2 INLET FLOW METER 1MGPS201 TTKS1#

L CELL2 ELECTROLYTIC CELL 1MGPS202 TK6# DC20V, 35A

L SENSOR 1MGPS203 TTKS1#

IAMCS-
L IAMCS SCU CABINET 57 (7IM57MGP21) (TTKS4#)
SCU57

SHIPBUILDING & OCEAN DEVELOPMENT