Вы находитесь на странице: 1из 4

Stair case Design

INPUT DATA
GOING
Effective Span (l) 4m
Riser (R) 0.15 m
Thread (T) 0.3 m
Waist Slab thickness (t) 0.2 m
Clear Cover 0.02 m
Effective Depth of Waist Slab (d) 0.172 m
Diameter of Bar () mm 16 mm
LANDING SLAB
Effective Span (l) 2m
Landing Slab thickness (t) 0.18 m

Grade of Concrete (fck) 25 Mpa


Grade of Steel (fy) 500 Mpa

Loading
Loads on going
Self weight of waist slab 5.59017 kN/m2 Loads on landing slab
Self weight of steps 1.875 kN/m2 Self weight of landing slab
Live Load 4 kN/m2 Live Load
Floor Finish Load 1 kN/m2 Floor Finish Load
Total Load 12.46517 kN Total Load
Factored Load 18.69775 kN Factored Load

Calculation
Support Reactions
RB 32.453559925 kN per meter width
RA 36.40711985 kN per meter width

Point of Contraflexure, x from B 3.079292 m

Moment, M 53.1672805808 kNm


Factored Moment,Mu 79.7509208711 kNm
R 2.6957450267 Mpa
Pt 0.0072482646 %
Ast 1246.701513795

Main Reinforcement
Diameter 16 mm Spacing
Provide Spacing
Distributors
Min Ast 240 mm2
Diameter 8 mm Spacing
Provide Spacing
gn

C B

A 4 2

Loads on landing slab


Self weight of landing slab 4.5 kN/m2
Live Load 4 kN/m2
Floor Finish Load 1 kN/m2
Total Load 9.5 kN
Factored Load 14.25 kN
Spacing 161.1934 mm
Provide Spacing 120 mm

Spacing 209.3333 mm
Provide Spacing 200 mm