Вы находитесь на странице: 1из 6

Pozo: MIPAYA 1001 XD

Reservorio: Ene
Operador: PLUSPETROL
Intervalo (MD m): 2444-2577
Fecha del Muestre 5/10/2011
Pr (psia): 3648
Tr (F): 179.96
Ps (psia): 1103.4
Ts (F) 76.3
Gas SG: 0.7447
Oil API: 63.31
Gas Bottle: A_1086
Oil Bottle: 4950_EA
Componente Pci (psia) Tci (R)
C1 666.4 343.33
C2 706.5 549.92
C3 616 665.06
i-C4 527.9 734.46
n-C4 550.6 765.62
i-C5 490.4 829.1
n-C5 488.6 845.8
C6 436.9 913.6
C7 396.8 972.7
C8 360.7 1024.22
C9 331.8 1070.68
C10 305.2 1112

C7+ 388.2 1066.38

Las propiedades del C7+ han sido calculadas mediante correlaciones


Recombinacin de las Muestras de Gas y Lquido tomadas en el Separador
1103.4 psia @ 76.3F

RGC (SCF/STB) = 23107.971 (tabla5) A= 60.91


liqSep=(lb/STB) 254.205 (tablaA2) B= 2.15
M liqSep (lb/lb.mol) = 118.04 (tablaA2) C= 63.06

Componente Yi Xi Zi calc Zi Real Error (%)


CO2 0.001 0.000 0.001 0.0009 3.42%
N2 0.012 0.000 0.012 0.0117 0.11%
C1 0.793 0.000 0.766 0.7657 0.02%
C2 0.102 0.000 0.099 0.0989 0.00%
C3 0.044 0.004 0.042 0.0423 0.10%
i-C4 0.007 0.005 0.007 0.0067 0.52%
n-C4 0.015 0.022 0.015 0.015 0.23%
i-C5 0.006 0.034 0.006 0.0065 0.20%
n-C5 0.005 0.049 0.007 0.0069 0.06%
C6 0.007 0.249 0.015 0.022 29.72% ciclo pentano en c6
C7 0.008 0.144 0.012 0.007 91.51%
C8 0.001 0.127 0.005 0.0044 9.70%
C9 0.000 0.091 0.003 0.0032 0.56%
C10 0.000 0.066 0.002 0.0022 1.83%
C11 0.055 0.002 0.0019 0.78%
C12 0.040 0.001 0.0014 3.65%
C13 0.032 0.001 0.0011 1.58%
C14 0.023 0.001 0.0008 0.96%
C15 0.016 0.001 0.0006 6.65%
C16 0.011 0.000 0.0004 3.52%
C17 0.008 0.000 0.0003 10.07%
C18 0.006 0.000 0.0002 4.16%
C19 0.004 0.000 0.0001 43.43%
C20+ 0.013 0.000 0.0004 7.57%
1.0001 1 1
Para todos los casos Absoluto(Zi/Zi) < 5%; la recombinacin es consistente

C7+ 0.008 0.636 0.030 0.024 26.98%


clo pentano en c6
Depletacin a Volumen Constante de una Muestra de Fluido
Balance Molar

Proco (psia) 3513 Vcelda (ft3) = 1


R= 10.73 nt (lb-mol) = 0.633
T= 639.96 Zgc = 0.809

K Presion Z1f %Ngc Ngc Ngc (Acum) VL (%)


0 3513 0.9859 0 0 0 0
1 3313 0.9857 5.0089 0.0317 0.0317 1.07
2 3013 0.976 11.9441 0.0439 0.0756 2.14
3 2713 0.9668 19.559 0.0482 0.1238 2.98
4 2413 0.9536 26.9036 0.0465 0.1702 3.58
5 2113 0.950 35.8673 0.0567 0.2270 4.09
6 1813 0.9509 45.1544 0.0588 0.2857 4.42
7 1513 0.9543 54.4455 0.0588 0.3445 4.54
8 1213 0.9584 63.6214 0.0581 0.4026 4.56
9 913 0.9652 72.7532 0.0578 0.4604 4.56
10 513 0.9732 84.7472 0.0759 0.5363 4.56

Leyenda:
nt = N total de moles
Zgc = Z a la Proco y Tr
Z1f = Z de la Fase Gaseosa
%Ngc = % Acumulado de N de moles de gas condensado retirado de la celda
Ngc = N de moles de gas condensado retirado de la celda
Ngc (Acum) = N de moles acumuladas de gas condensado retiradas de la celda
VL (%) = lquido condensado en % del volumen total de la celda
NL N de moles de lquido condensado en la celda
Ngc = N de moles de gas que quedan en la celda

NL > 0 para todas las presiones; el Balance Molar es consistente


na Muestra de Fluido

Ngc Ngc+Ngc NL
0.6328 0.633 0
0.4842 0.516 0.116844263038376
0.4399 0.484 0.1172
0.3965 0.445 0.1125
0.3553 0.402 0.1072
0.3106 0.367 0.0952
0.2654 0.324 0.0817
0.2204 0.279 0.0678
0.1759 0.234 0.0543
0.1315 0.189 0.0409
0.0733 0.149 0.0233