Вы находитесь на странице: 1из 12

Draft Piping Vibrational Study

New Gathering Centre 16 (New GC-16)


AlKhorayef Kuwait

Page |
13

APPENDIX C
(Marked-Up Stress Isometrics)

Ennovate Consultants
Calgary
Add Guide
Guide Load = +/- 15 kN
10 mm THK Plate To be Field Fit
(Typical)

Clamp Anvil Fig 212 or Equivalent

Add Guide All Around as per


attached Detail
Load E/W Load = +/- 8 kN
Load N/S = +/- 2 kN

Guide Support available


in this location (Drg. Attached)

1600

Spring support Available


in this location VS-42
10 mm THK Plate To be Field Fit
(Typical)

Guide Support available


this location

Clamp Anvil Fig 212 or Equivalent

Add Guide All Around as per


attached Detail
Load E/W Load = +/- 8 kN
Load N/S = +/- 2 kN

1600
Spring support Available
in this location
VS-15
10 mm THK Plate To be Field Fit
(Typical)

Guide Support available


this location
Clamp Anvil Fig 212 or Equivalent

Add Guide All Around as per


attached Detail
Load E/W Load = +/- 8 kN
Load N/S = +/- 2 kN

1600

Spring support Available


in this location
VS-46
Add Guide
Guide Load = +/- 25 kN
10 mm THK Plate To be Field Fit
(Typical)

Guide Support available


this location

Clamp Anvil Fig 212 or Equivalent

Add Guide All Around as per


attached Detail
Load E/W Load = +/- 8 kN
Load N/S = +/- 2 kN

1600
Spring support Available t
his location

VS-16
Guide Support available
this location

Add Guide All Around as per


attached Detail
Load E/W Load = +/- 8 kN
Load N/S = +/- 2 kN

1600
Spring support Available in
this location 10 mm THK Plate To be Field Fit
VS-17 (Typical)

Clamp Anvil Fig 212 or Equivalent


Guide Support available in
this location

Add Guide All Around as per


attached Detail
Load E/W Load = +/- 8 kN
Load N/S = +/- 2 kN

1600
Spring support Available
this location
VS-18
10 mm THK Plate To be Field Fit
(Typical)

Clamp Anvil Fig 212 or Equivalent