5 Set-up and connection ...................................................................................................... 25
5.1 Installation site ................................................................................................................ 25
5.2 Power supply .................................................................................................................. 25
5.2.1 Type of connection .................................................................................................... 25
5.2.2 Customer-provided fuses ........................................................................................... 25
6 Using the centrifuge .......................................................................................................... 26
6.1 Initial start-up .................................................................................................................. 26
6.2 Switching the centrifuge on ............................................................................................. 26
6.2.1 Opening and closing the lid ........................................................................................ 26
6.2.2 Installation of rotors and accessories ......................................................................... 27
6.2.2.1 Installation of the rotor........................................................................................ 27
6.2.2.2 Installation of the microhaematocrit rotor............................................................ 28
6.2.2.3 Installation of accessories .................................................................................. 29
6.2.2.4 Tubes................................................................................................................. 29
6.3 Control System "Spincontrol Basic" ................................................................................ 30
6.3.1 User interface ............................................................................................................ 30
6.3.2 Display....................................................................................................................... 30
6.3.3 Starting a centrifugation run ....................................................................................... 31
6.3.4 Interrupting a centrifugation run ................................................................................. 31
6.3.5 Interrupting a deceleration process ............................................................................ 31
6.3.6 Speed / Relative centrifugal force (RCF).................................................................... 31
6.3.6.1 Changing the speed/RCF value during centrifugation ........................................ 31
6.3.7 Runtime ..................................................................................................................... 32
6.3.7.1 Changing the runtime during centrifugation ........................................................ 32
6.3.7.2 Short run (quick run) .......................................................................................... 32
6.3.7.3 Continuous run................................................................................................... 33
6.3.8 Softstart and softstop function ................................................................................... 33
6.3.9 Rotor selection........................................................................................................... 34
6.4 Switching the centrifuge off ............................................................................................. 34
7 Malfunctions and error correction .................................................................................... 35
7.1 General malfunctions ...................................................................................................... 35
7.1.1 Emergency lid release ............................................................................................... 36
7.2 Table of error codes ........................................................................................................ 37
7.3 Service contact ............................................................................................................... 38
Table of contents
8 Maintenance and service................................................................................................... 39
8.1 Maintenance ................................................................................................................... 39
8.1.1 Centrifuge .................................................................................................................. 39
8.1.2 Accessories ............................................................................................................... 40
8.1.2.1 Plastic accessories ............................................................................................ 41
8.1.3 Rotors ........................................................................................................................ 41
8.1.4 Microhaematocrit rotor ............................................................................................... 41
8.1.5 Glass breakage ......................................................................................................... 42
8.2 Sterilisation and disinfection of the rotor chamber and accessories ................................ 42
8.2.1 Autoclaving ................................................................................................................ 43
8.3 Service ........................................................................................................................... 44
8.4 Return of defective parts ................................................................................................. 45
9 Disposal.............................................................................................................................. 47
9.1 Disposal of the centrifuge ............................................................................................... 47
9.2 Disposal of the packaging ............................................................................................... 47
10 Technical data .................................................................................................................... 48
10.1 Ambient conditions ......................................................................................................... 48
10.2 Technical documentation ................................................................................................ 49
11 Appendix ............................................................................................................................ 50
11.1 Range of accessories ..................................................................................................... 50
11.1.1 Rotor radii .................................................................................................................. 51
11.2 Speed-gravitational-field-diagram ................................................................................... 52
11.3 Table of the service life of rotors and accessories........................................................... 53
11.4 Resistance data .............................................................................................................. 54
11.5 EC Declaration of Conformity.......................................................................................... 59
12 Index ................................................................................................................................... 61
Table of contents
1 General information
Pos : 1 /100 Sigma/100 BA Z entrifug en Sig ma ( Standardmodule) /010 Allgemeine Infor mationen/010 Allgemeine Infor mationen ==================================== @ 26\mod_1405318948131_68.doc x @ 191680 @ 1 @ 1
1 General information
Pos : 2 /100 Sigma/100 BA Z entrifug en Sig ma ( Standardmodule) /010 Allgemeine Infor mationen/010- 0010 Stell enwert der Betriebs anl eitung------------------------------------------------------- @ 26\mod_1405318949962_68.doc x @ 191694 @ 2 @ 1
Pos : 4 /100 Sigma/100 BA Z entrifug en Sig ma ( Standardmodule) /010 Allgemeine Infor mationen/010- 0020 Besti mmungsgem e Ver wendung------------------------------------------- @ 26\mod_1405318951312_68.doc x @ 191709 @ 2 @ 1
Pos : 6 /100 Sigma/100 BA Z entrifug en Sig ma ( Standardmodule) /010 Allgemeine Infor mationen/010- 0030 Gewhrleis tung und H aftung-------------------------------------------------- @ 26\mod_1405318955234_68.doc x @ 191737 @ 2 @ 1
1 General information
Pos : 8 /100 Sigma/100 BA Z entrifug en Sig ma ( Standardmodule) /010 Allgemeine Infor mationen/010- 0040 Urheberrec ht----------------------------------------------------------------- @ 26\mod_1405318956858_68.doc x @ 191751 @ 2 @ 1
1.4 Copyright
The copyright concerning the operating manual remains with
Sigma Laborzentrifugen GmbH.
The operating manual is solely intended for the operator and their
personnel. It includes instructions and information that must not be
duplicated,
distributed, or
communicated in any other way.
Non-compliance may be prosecuted under criminal law.
Pos : 9 /010 U ni versal modul e/Leerzeil e @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 10 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/010 Allgemei ne Infor mati onen/010-0050 N or men und Vorschriften------------------------------------------------------ @ 26\mod_1405318958202_68.doc x @ 191765 @ 2 @ 1
Pos : 12 /100 Sigma/110 BA Zentrifugen Sigma (Pr ojekte) /1- 14_1-14K/010 Allgemeine Infor mationen/010- 0060 Li eferumfang 1- 14_1-14K------------------------------------------------------- @ 28\mod_1405320748030_68.doc x @ 195237 @ 2 @ 1
Documentation
Operating manual incl. EC declaration of conformity
(see chapter 11.5 - "EC Declaration of Conformity")
Accessories
according to your order, our order confirmation, and our delivery note.
Pos : 13 /010 U ni vers al module/Absc hnitts wechsel @ 0\mod_1202124514062_0.doc x @ 418 @ @ 1
1 Lid
2 Display
3 User interface
(see chapter 6.3.1 -
"User interface")
1 Manufacturer and
registered office
2 Type
3 Serial number
4 Max. speed
5 Max. kinetic energy
6 Max. density
7 Nominal voltage
8 Input fuse
9 Symbol for special
disposal (see chapter
9 - "Disposal")
10 CE-mark in
compliance with the
directive 2006/42/EG
11 Part number
12 Year of manufacture
13 Power consumption
Fig. 1: Example of a name plate
Pos : 20 /010 U ni vers al module/Seitenwec hsel @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
Pos : 24 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/020 Aufbau und Wir kungs weise/020-0020-0020 Anwendungsbereic h @ 26\mod_1405318986763_68.doc x @ 191835 @ 3 @ 1
Das
Pos : 28 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/020 Aufbau und Wir kungs weise/020-0020-0020- 0020 Dic hte @ 26\mod_1405318989359_68.doc x @ 191863 @ 4 @ 1
2.2.2.2 Density
The laboratory centrifuge is suitable for the separation of constituents of
different densities in mixtures with a maximum density of 1.2 g/cm3. All
information concerning the speed of rotors and accessories refers to liquids
with a density corresponding to this specification. If the density is above this
value, the maximum permissible speed of the centrifuge must be reduced
based on the following formula:
(1,2 / Rho)
n = nmax x
3
Rho = density in g/cm
Pos : 29 /010 U ni vers al module/Absc hnitts wechsel @ 0\mod_1202124514062_0.doc x @ 418 @ @ 1
3 Safety
Pos : 31 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030 Sic her hei t======================================= @ 26\mod_1405319007254_68.doc x @ 191877 @ 1 @ 1
3 Safety
Pos : 32 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0011 Besc hilderung des Gerts ( nur 1-14, 1- 14K) @ 30\mod_1405404003431_68.doc x @ 203935 @ 2 @ 1
Dangerous voltage
I On (Power)
Hot surface
0 Off (Power)
RCM mark
4C Guarantee
(only for Australia)
Not all of the symbols/labels are used for this centrifuge type.
NOTE
Pos : 33 /010 U ni vers al module/Seitenwec hsel @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
3 Safety
Pos : 34 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0020 Symbol- und Hi nweis er klr ung en @ 26\mod_1405319013955_68.doc x @ 191947 @ 2 @ 1
This symbol stands for a direct hazard to the life and health of persons.
This symbol stands for a direct hazard to the life and health of persons
due to electrical voltage.
This symbol stands for a potential hazard to the life and health of persons.
NOTE
Pos : 35 /010 U ni vers al module/Seitenwec hsel @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
3 Safety
Pos : 36 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0030 Ver antwortung des Betrei bers @ 26\mod_1405319015364_68.doc x @ 191961 @ 2 @ 1
Pos : 38 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0040 Bedienpers onal @ 26\mod_1405319017634_68.doc x @ 191989 @ 2 @ 1
Pos : 40 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0050 Infor melle Sic herheits hinweise @ 26\mod_1405319019966_68.doc x @ 192017 @ 2 @ 1
3 Safety
Pos : 42 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060 Sic herheits hinweis e------------------------------------------------------------- @ 26\mod_1405319021480_68.doc x @ 192031 @ 2 @ 1
Pos : 45 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0020 M ec hanisc he Sic her heit (au er 1-16/1-16K) @ 26\mod_1405319024314_68.doc x @ 192059 @ 3 @ 1
3 Safety
Prior to any start-up, check the centrifuge, rotor, and accessories for
signs of damage that can be discerned from the outside. Special
attention must be paid to all of the rubber parts (e.g. motor cover, lid
seal, and adapters) in terms of visible structural changes. Defective
WARNING parts must be replaced immediately.
Open the centrifuge when it is not in use so that moisture can
evaporate.
Pos : 46 /010 U ni vers al module/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 47 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0031 Brandschutz Wechs elsic her ung en @ 26\mod_1405319027110_68.doc x @ 192087 @ 3 @ 1
Always use fuses with the same type and rating specified.
Do not spin explosive or inflammable substances.
Do not use the centrifuge within hazardous locations.
DANGER
Pos : 48 /010 U ni vers al module/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 49 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0040 C hemis che und bi ologisc he Sic her hei t @ 26\mod_1405319028141_68.doc x @ 192101 @ 3 @ 1
3 Safety
Pos : 51 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0050 Sicherheits hi nweis e z ur Z entrifug ation @ 26\mod_1405319029632_68.doc x @ 192115 @ 3 @ 1
Pos : 53 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0060 Bestndigkeit von Kuns tstoffen @ 26\mod_1405319031161_68.doc x @ 192129 @ 3 @ 1
NOTE
Pos : 54 /010 U ni vers al module/Seitenwec hsel @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
3 Safety
Pos : 55 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0060-0070 Lebensdauer von R otoren und Z ubehr @ 26\mod_1405319032612_68.doc x @ 192143 @ 3 @ 1
3 Safety
Pos : 57 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0070 Sic herheits einric htung en----------------------------------------- @ 27\mod_1405319034809_68.doc x @ 192157 @ 2 @ 1
Pos : 60 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0070-0032 Systemkontroll e Spincontr ol Basic+ Eas y+U ni versal @ 27\mod_1405319041777_68.doc x @ 192227 @ 3 @ 1
Pos : 63 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0080 Ver halten bei Gefahren und Unfll en @ 27\mod_1405319051188_68.doc x @ 192325 @ 2 @ 1
Pos : 66 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/030 Sic her heit/030-0100 R estrisi ken @ 27\mod_1405319052885_68.doc x @ 192339 @ 2 @ 1
Height: 176 mm
Width: 212 mm
Depth: 266 mm
Weight: 6 kg
Pos : 71 /010 U ni vers al module/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 72 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/040 Lagerung und Tr ans port/040-0020 Lagerbedi ngungen @ 27\mod_1405319161442_68.doc x @ 192367 @ 2 @ 1
Pos : 74 /100 Sigma/110 BA Zentrifugen Sigma (Pr ojekte) /1- 14_1-14K/040 Lager ung und Tr ansport/040- 0030 Trans por thi nweis e 1-14 @ 28\mod_1405320775528_68.doc x @ 195349 @ 2 @ 1
CAUTION
For transport use suitable packaging and, if at all possible, the original
packaging. (see chapter 4.4 - "Packaging").
Pos : 75 /010 U ni vers al module/Seitenwec hsel @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
4.4 Packaging
The centrifuge is packaged in a cardboard box.
Open the box.
Take out the box containing the accessories.
Lift the centrifuge with both foam cushions out of the cardboard box.
When lifting the centrifuge, always reach under the centrifuge from the
side.
CAUTION
Retain the packaging for any possible future transport of the centrifuge.
Pos : 77 /010 U ni vers al module/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 78 /100 Sigma/110 BA Zentrifugen Sigma (Pr ojekte) /1- 14_1-14K/040 Lager ung und Tr ansport/040- 0050 Trans por tsicherung 1-14_1-14K @ 28\mod_1405320778751_68.doc x @ 195405 @ 2 @ 1
Pos : 84 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/050 Aufstellung und Ans chl uss/050- 0020 Energievers orgung------------------------------------------------------ @ 27\mod_1405319175630_68.doc x @ 192409 @ 2 @ 1
The operating voltage on the name plate must correspond to the local
supply voltage!
DANGER
Pos : 87 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/050 Aufstellung und Ans chl uss/050- 0020-0020 Sic herungen baus eits ( auer 3-30KS) @ 7\mod_1306312302397_68.doc x @ 43513 @ 33 @ 1
Before the initial start-up, please ensure that your centrifuge is properly
set up and installed (see chapter 5 - "Set-up and connection").
DANGER
Pos : 92 /010 U ni vers al module/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 93 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/061 Betrieb_Spinc ontrol Basic/061-0020 Ei nsc halten @ 27\mod_1405320315792_68.doc x @ 193697 @ 2 @ 1
Pos : 95 /100 Sigma/100 BA Zentrifugen Sigma (Standar dmodule)/061 Betrieb_Spinc ontrol Basic/061-0020- 0010 ffnen und Sc hlie en des Dec kels @ 27\mod_1405320316807_68.doc x @ 193711 @ 3 @ 1
Do not place your fingers between the lid and the housing when closing
the lid. Risk of crushing!
WARNING
Pos : 96 /010 U ni vers al module/Seitenwec hsel @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
1 Safety lock
2 Snap-on lid
3 Rotor fastening nut
4 Motor shaft
5 Angle rotor
Fig. 4: Rotor fastening nut from above (A) and from below (B)
To lock the snap-on lid, pull the safety lock in the middle of the lock
upwards and put the lid on the rotor. The snap-on lid will be locked
when the safety lock is released.
Once a day or after 20 cycles, the rotor tie-down screw must be loosened
by some turns, and the rotor must be lifted and fastened again. This
ensures a proper connection between the rotor and the motor shaft.
WARNING
Rotors can be used without a cover. This leads, however, to higher levels
of noise and temperatures when running.
NOTE
Fig. 5: Microhaematokrit rotor (part no. 11026) with reader (part no. 17028)
Unscrew the rotor fastening nut from the motor shaft (anti-clockwise).
Lower the microhaematocrit rotor with its central bore straight down
onto the motor shaft.
Hand-tighten the rotor fastening nut clockwise (corresponds to 1 Nm).
The rotor fastening nut and conical spring washer must face the
microhematocrite rotor (i.e. the writing must be shown on top).
Fig. 6: Rotor fastening nut from above (A) and from below (B)
Operation
Fill the capillary tubes with blood and seal them at one end with putty or
by fusion.
Place the capillary tubes into the recesses of the rotor with the sealed
end against the rubber ring. Ensure that the capillary tubes fit tightly
against the rubber ring. The opposite places must be loaded.
Put the rotor cover on and lock it.
Close the centrifuge lid.
Enter the following parameters: speed 13,000 rpm, gravitational field
RCF max. 11,903 x g, time approx. 5 min.
Start the centrifuge.
Open the centrifuge lid when the rotor has stopped.
Unlock the rotor cover and lift it off.
Pos : 102 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/061 Betrieb_Spi nc ontr ol Basic /061-0020-0020- 0030 Ei ns etz en von Zubehr @ 27\mod_1405320318688_68.doc x @ 193739 @ 4 @ 1
correct incorrect
Pos : 104 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/061 Betrieb_Spi nc ontr ol Basic /061-0020-0020- 0040 Gef e @ 27\mod_1405320320154_68.doc x @ 193753 @ 4 @ 1
6.2.2.4 Tubes
Load the tubes outside of the centrifuge. Liquids in the bores of the rotor
cause corrosion.
Fill the tubes carefully and arrange them according to their weight.
Imbalances result in the excessive wear of the bearings.
Follow the safety instructions and hazard warnings (see chapter 3 -
"Safety")!
Pos : 105 /010 Uni vers almodul e/Seitenwechs el @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
1 Display
2 Select key
3 Arrow keys
4 Lid key
5 Start/Stop key
The centrifuge is started directly via the user interface. When the centrifuge
is switched on, all segments will be illuminated for a short time. It is now
ready for operation.
Pos : 108 /010 Uni vers almodul e/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 109 /100 Sig ma/110 BA Z entrifugen Sig ma (Proj ekte)/1-14_1- 14K/061 Betrieb/Spi ncontr ol Basic /061-0030-0020 Displ ay 1-14 @ 28\mod_1405320825270_68.doc x @ 195531 @ 3 @ 1
6.3.2 Display
The centrifuge display has the following display fields:
Pos : 113 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/061 Betrieb_Spi nc ontr ol Basic /Spincontr ol Basic /061-0030-0040 Unter brec hen ei ner Z entrifugati on @ 27\mod_1405320350701_68.doc x @ 193809 @ 3 @ 1
Pos : 115 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/061 Betrieb_Spi nc ontr ol Basic /Spincontr ol Basic /061-0030-0050 Unter brec hen ei nes Br ems vorgangs @ 27\mod_1405320352187_68.doc x @ 193823 @ 3 @ 1
Pos : 117 /100 Sig ma/110 BA Z entrifugen Sig ma (Proj ekte)/1-14_1- 14K/061 Betrieb/Spi ncontr ol Basic /061-0030-0060 Drehzahl / R elati ve Z entrifugalbesc hleunigung (RZ B) - nur 1-14 @ 28\mod_1405320827081_68.doc x @ 195559 @ 3 @ 1
Pos : 119 /100 Sig ma/110 BA Z entrifugen Sig ma (Proj ekte)/1-14_1- 14K/061 Betrieb/Spi ncontr ol Basic /061-0030-0060- 0010 nder n des Drehz ahl-/RZ B- Wertes whrend des Laufs - nur 1- 14 @ 28\mod_1405320827915_68.doc x @ 195573 @ 4 @ 1
6.3.7 Runtime
The preselected total runtime is displayed in the lower line of the display.
During centrifugation, the remaining runtime is displayed. The runtime of
the centrifuge can be set at one-second-intervals up to 99 minutes and 59
seconds.
To select a runtime, press the select key repeatedly until the time unit
flashes on the display.
Select the desired runtime by pressing the arrow keys.
Confirm the selection by pressing the start/stop key.
The data will also be accepted and saved after approx. 20 seconds if no
other key is pressed within this time period.
Pos : 122 /010 Uni vers almodul e/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 123 /100 Sig ma/110 BA Z entrifugen Sig ma (Proj ekte)/1-14_1- 14K/061 Betrieb/Spi ncontr ol Basic /061-0030-0070- 0010 nder n der Laufzei t whr end des Laufs (nur 1- 14) @ 28\mod_1405320829604_68.doc x @ 195601 @ 4 @ 1
If the centrifugation time is changed during the run, the centrifuge will run
for the entire new time and will disregard the previous runtime that has
already elapsed.
NOTE
Pos : 124 /010 Uni vers almodul e/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 125 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/061 Betrieb_Spi nc ontr ol Basic /Spincontr ol Basic /061-0030-0070- 0020 Kurzz eitbetrieb (nur 1-14, 1-14K) @ 28\mod_1405321080308_68.doc x @ 196091 @ 4 @ 1
Pos : 129 /100 Sig ma/110 BA Z entrifugen Sig ma (Proj ekte)/1-14_1- 14K/061 Betrieb/Spi ncontr ol Basic /061-0030-0090 Softstar t- und Softstop-F unkti onen (nur 1-14) @ 28\mod_1405320831467_68.doc x @ 195629 @ 3 @ 1
Code 6 7 8 9 10
NOTE
Pos : 132 /010 Uni vers almodul e/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 133 /010 Uni vers almodul e/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 134 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/061 Betrieb_Spi nc ontr ol Basic /061-0040 Auss chalten @ 27\mod_1405320321633_68.doc x @ 193767 @ 2 @ 1
Do not switch the centrifuge off until OFF is displayed! This is necessary
in order to ensure that the rotor is at a complete standstill.
WARNING
No indication on the display No power in the mains supply Check fuse in the mains supply
Centrifuge cannot be started: The set Several Netz aus/ein. Falls sich der Fehler
speed value is displayed in an wiederholt, Service verstndigen
unchanged manner
The lid lock is not closed correctly Open and close lid. If the error
occurs again, contact service
Fig. :10 Opening for the emergency lid release at the bottom of the centrifuge
Do not unlock the lid unless the rotor is at a standstill and unless there is
no danger to other persons!
WARNING
If the lid is opened via the emergency lid release during a centrifuge run,
the centrifuge will be switched off immediately and decelerate in a brake-
less manner.
As a general rule, the lock can be opened more easily with the emergency
lid release system if the load on it is relieved by exerting slight pressure on
the lid.
Pos : 141 /010 Uni vers almodul e/Seitenwechs el @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
1-9 System error Allow to slow down All these errors stop the
Power off/on centrifuge or cause it to
decelerate brakeless
30-39 EEPROM error Allow to slow down With error 34, 35, and 36, the
Power off/on centrifuge will stop;
with error 37 and 38 only an
error message will be given
50-59 Lid error Press lid key With error 50 and 51, the
Close lid centrifuge will stop
Remove foreign matter from the opening
of the lid lock device
80-89 Parameter error Power off With error 83, error message
Allow to cool down only
Provide for better ventilation
NOTE
Pos : 143 /010 Uni vers almodul e/Seitenwechs el @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
From Germany:
Contact
Outside Germany:
Contact our agency in your country. All agencies are listed at
www.sigma-zentrifugen.de [Sales Partners]
If you would like to utilise our service, please state the type of your
centrifuge and its serial number.
NOTE
Pos : 145 /010 Uni vers almodul e/Abs chnitts wec hs el @ 0\mod_1202124514062_0.doc x @ 418 @ @ 1
CAUTION
Pos : 149 /010 Uni vers almodul e/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 150 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/080 War tung und Instandhaltung/080-0010 Wartungsar beiten--------------------------------------- @ 28\mod_1405320613978_68.doc x @ 194803 @ 2 @ 1
8.1 Maintenance
Pos : 151 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/080 War tung und Instandhaltung/080-0010- 0010 Zentrifuge @ 28\mod_1405320615295_68.doc x @ 194817 @ 3 @ 1
8.1.1 Centrifuge
Unplug the mains power plug before cleaning.
Carefully remove all liquids, including water and particularly all the
solvents, acids, and alkaline solutions from the rotor chamber using a
cloth in order to avoid damage to the motor bearings.
If the centrifuge has been contaminated with toxic, radioactive, or
pathogenic substances, clean the rotor chamber immediately with a
suitable decontamination agent (depending on the type of
contamination).
Take suitable precautions for your own safety if there is a risk of toxic,
radioactive, or pathogenic contamination.
WARNING
Grease the motor shaft slightly after cleaning (grease for load-bearing
bolts part no. 70284).
Pos : 152 /010 Uni vers almodul e/Seitenwechs el @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
8.1.2 Accessories
WARNING
Pos : 156 /010 Uni vers almodul e/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 157 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/080 War tung und Instandhaltung/080-0010- 0031 Rotor en ( nur Basic) @ 28\mod_1405320622336_68.doc x @ 194887 @ 3 @ 1
8.1.3 Rotors
The rotors are produced with the highest precision, in order to withstand the
permanent high stress from high gravitational fields.
Chemical reactions as well as stress-corrosion (combination of oscillating
pressure and chemical reaction) can affect or destroy the metals. Barely
detectable cracks on the surface can expand and weaken the material
without any visible signs.
Check the material regularly (at least once a month) for
cracks
visible damage of the surface
pressure marks
signs of corrosion
other changes.
Pos : 159 /100 Sig ma/110 BA Z entrifugen Sig ma (Proj ekte)/1-14_1- 14K/080 Wartung und Ins tandhaltung/080- 0010-0040 Mi kr ohmatokrittell er 1- 14_1-14K @ 28\mod_1405320862886_68.doc x @ 195685 @ 3 @ 1
In the case of glass breakage, immediately remove all glass particles (e.g.
with a vacuum cleaner). Replace the rubber cushions since even thorough
cleaning will not remove all glass particles.
CAUTION
Glass particles will damage the surface coating (e.g. anodising) of the
buckets, which will then lead to corrosion.
Glass particles in the rubber cushions of the buckets will cause glass
breakage again.
Glass particles on the pivot bearing of the load- bearing bolts prevent the
buckets and carriers from swinging evenly, which will cause an imbalance.
Glass particles in the rotor chamber will cause metal abrasion due to the
strong air circulation. This metal dust will not only pollute the rotor chamber,
rotor, and materials to be centrifuged but also damage the surfaces of the
accessories, rotors, and rotor chamber.
In order to completely remove the glass particles and metal dust from
the rotor chamber:
Grease the upper third of the rotor chamber with e.g. Vaseline.
Then, let the rotor rotate for a few minutes at a moderate speed
(approx. 2000 rpm). The glass and metal particles will now collect at the
greased part.
Remove the grease with the glass and metal particles with a cloth.
If necessary, repeat this procedure.
Pos : 162 /010 Uni vers almodul e/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 163 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/080 War tung und Instandhaltung/080-0020 Sterilisati on und Desinfektion von Rotor kammer und Zubehr @ 28\mod_1405320626090_68.doc x @ 194929 @ 2 @ 1
DANGER
Pos : 164 /010 Uni vers almodul e/Seitenwechs el @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
8.2.1 Autoclaving
The service life of the accessories essentially depends on the frequency of
autoclaving and use.
Replace the accessories immediately when the parts show changes in
colour or structure or in the occurrence of leaks etc.
During autoclaving, the caps of the tubes must not be screwed on in
order to avoid the deformation of the tubes.
It cannot be excluded that plastic parts, e.g. lids or carriers, may deform
during autoclaving.
NOTE
8.3 Service
In the event of service work that requires the removal of the panels, there
is a risk of electric shock or mechanical injury. Only qualified specialist
personnel is authorised to perform this service work.
DANGER
In Germany:
Contact
Sigma Laborzentrifugen GmbH
An der Unteren Sse 50
37520 Osterode (Germany)
Tel. +49 (0) 55 22 / 50 07-44 44
E-mail: support.lab@sigma-zentrifugen.de
Outside Germany:
Contact our agency in your country. All agencies are listed at
www.sigma-zentrifugen.de [Sales Partners]
If you would like to utilise our service, please state the type of your
centrifuge and its serial number.
NOTE
Pos : 168 /010 Uni vers almodul e/Seitenwechs el @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
1. Declaration of decontamination
As a certified company and due to the legal regulations for the
protection of our employees and of the environment, we are obliged to
certify the harmlessness of all incoming goods. For this purpose, we
require a declaration of decontamination.
The form must be filled in completely and signed by authorised and
specialised personnel only.
Affix the original form in a clearly visible manner to the outside of the
packaging.
NOTE
9 Disposal
Pos : 172 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/090 Entsorgung/090 Ents orgung===================================== @ 28\mod_1405320658842_68.doc x @ 194985 @ 1 @ 1
9 Disposal
Pos : 173 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/090 Entsorgung/090-0010 Entsorgung der Z entrifuge---------------------------------------------- @ 28\mod_1405320660029_68.doc x @ 194999 @ 2 @ 1
Pos : 175 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/090 Entsorgung/090-0020 Entsorgung der Verpac kung-------------------------------------------------- @ 28\mod_1405320661383_68.doc x @ 195013 @ 2 @ 1
10 Technical data
Pos : 178 /100 Sig ma/110 BA Z entrifugen Sig ma (Proj ekte)/1-14_1- 14K/100 T ec hnis che D aten/100 T ec hnisc he D aten 1- 14================================= @ 28\mod_1405320871520_68.doc x @ 195699 @ 1 @ 1
10 Technical data
Manufacturer Sigma Laborzentrifugen GmbH
An der Unteren Sse 50
37520 Osterode
Germany
Type: 1-14
Connection requirements
Electrical connection: see name plate
Protection class: I
IP code: 20
Connected load (kVA): 0.157
Power consumption (kW): 0.095
Max. current consumption (A): 0,68 (at 220-240 V / 50-60 Hz)
Input fuse (AT): 2.0 (at 220-240 V / 50-60 Hz)
Performance data
Max. speed (rpm): 14,800
Max. capacity (ml): 48
Max. gravitational field (x g) 16,163
Max. kinetic energy (Nm): 1,721
Other parameters
Time range: 10 sec to 99 min 59 sec, short run, continuous run
Physical data
Height (mm): 176
Height with opened lid (mm): 310
Width (mm): 212
Depth (mm): 266
Weight (kg): 6.0
Noise level (dB(A)): <60 (at max. speed)
Pos : 179 /010 Uni vers almodul e/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 180 /010 Uni vers almodul e/Leerz eile @ 0\mod_1202116244500_0.doc x @ 114 @ @ 1
Pos : 181 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/100 T ec hnisc he D aten/100- 0010 U mgebungsbedi ngungen ung ekhlt @ 28\mod_1405320680121_68.doc x @ 195041 @ 2 @ 1
NOTE
Pos : 183 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/100 T ec hnisc he D aten/100- 0020 Technisc he Dokumentation @ 28\mod_1405320681369_68.doc x @ 195055 @ 2 @ 1
10 Technical data
11 Appendix
Pos : 186 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/110 Anhang/110 Anhang===================================== @ 28\mod_1405320699310_68.doc x @ 195069 @ 1 @ 1
11 Appendix
Pos : 187 /100 Sig ma/110 BA Z entrifugen Sig ma (Proj ekte)/1-14_1- 14K/110 Anhang/110- 0010 Z ubehr programm 1-14 @ 28\mod_1405320895919_68.doc x @ 195727 @ 2 @ 1
12082 Angle rotor 12 x 1.5/2.0 ml, for reaction vials e.g. no. 15008, 15040,
incl. polysulfone lid no. 17882
Radius max. 6.2 cm, radius max. 2.9 cm, angle 45 14 800 15 183
12083 Angle rotor 18 x 1.5/2.0 ml, for reaction vials, e.g. no. 15008, 15040 or
18 x 0.25/0.4 ml e.g. no. 15014, 2 lines, incl. polysulfone lid no. 17882,
angle 32/57
Radii max. Radii min.
6.4 cm 3.2 cm 14 800 15 673
5.9 cm 2.5 cm 14 448
12084 Angle rotor 24 x 1.5/2.0 ml, for reaction vials, e.g. no. 15008, 15040,
incl. polysulfone lid no. 17882
Radius max. 6.6 cm, radius min. 3.8 and 3.0 cm, angle 32/37 14 800 16 163
12092 Angle rotor made of polypropylene, 12 x 1.5/2.0 ml, for reaction vials e.g.
no. 15008, 15040, incl. polysulfone lid no. 17882, angle 45
Radius max. 6.2 cm, radius min.2.9 cm 14 800 15 183
12093 Angle rotor made of polypropylene, 18 x 1.5/2.0 ml, for reaction vials
e.g. no. 15008, 15040 or 18 x 0,25/0,4 ml e.g. no. 15014, 2 lines,
incl. polysulfone lid no. 17882, 42/48
Radii max. Radii min.
6.4 cm 3.2 cm 14 800 15 673
5.9 cm 2.5 cm 14 448
12094 Angle rotor made of polypropylene, 24 x 1.5/2.0 ml, for reaction vials e.g.
no. 15008, 15040, incl. polysulfone lid no. 17882, angle 32/53
Radius max. 6.6 cm, radius min. 3.8 and 3.0 cm 14 800 16 163
12096 Angle rotor made of polypropylene, for 2 PCR-strips with 8 tubes 0.2 ml
e.g no. 15042, incl. polysulfone lid no. 17882, angle 45
Radius max. 4.8 cm, radius 2.1 cm 14 800 11 755
12097 Angle rotor 12 x 1.5/2.0 ml high edge, specially for reaction vials with filter,
incl. polysulfone lid no. 17933, angle 45
Radius max. 6.2 cm, radius 2.9 cm 14 800 15 183
13000 Adapter for reaction vials 0.25/0.4 ml no. 15014, 1 set = 2 pcs.
13002 Adapter for reaction vials 0.5/0.75 ml, Adapter for reaction vials
0.5/0.75 ml, e.g. no. 15005
13021 Adapter for PCR-tube 0.2 ml, e.g no. 15042, 1 set = 2 pcs.
11 Appendix
Pos : 189 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/110 Anhang/110-0010- 0024 R adi en der R otoren ( WR+Mikr ohmatokritteller) @ 28\mod_1405320704464_68.doc x @ 195139 @ 3 @ 1
11 Appendix
Pos : 191 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/110 Anhang/110-0020 Dr ehz ahl-Sc hwer efeld-Diagr amm @ 28\mod_1405320705642_68.doc x @ 195153 @ 2 @ 1
11.2 Speed-gravitational-field-diagram
11 Appendix
Pos : 193 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/110 Anhang/110-0040 T abell e: Lebensdauer von R otoren und Z ubehr @ 28\mod_1405320709911_68.doc x @ 195195 @ 2 @ 1
11 Appendix
Pos : 195 /100 Sig ma/100 BA Z entrifugen Sig ma (Standardmodul e)/110 Anhang/110-0050 Bestndigkeits tabelle @ 28\mod_1405320711439_68.doc x @ 195209 @ 2 @ 1
NOTE
Acrylonitrile-butadiene-
Polytetrafluorethylene
Polyoxymethylene
- no data
Polycarbonate
Polypropylene
1 resistant Concentration
Polyethylene
High Density
Polysulfone
caoutchouc
2 practically resistant
Aluminium
Polyamide
3 partially resistant
4 not resistant HDPE
PTFE
POM
NBR
PSU
PVC
PVC
[%]
PC
PA
PP
AL
Medium Formula
Acetaldehyde C2H4O 40 3 2 4 2 3 4 4 - 1 4 1
Acetamide C2H5NO saturated 1 1 4 1 1 4 4 - 1 - 1
Acetone C3H6O 100 1 1 4 1 1 4 4 - 1 4 1
Acrylonitrile C3H3N 100 1 1 4 3 3 4 4 4 1 4 1
Allyl alcohol C3H6O 96 1 3 3 2 2 2 2 4 1 1 1
Aluminium chloride AlCl3 saturated 1 3 2 4 1 - 1 - 1 1 4
Aluminium sulfate Al2(SO4)3 10 1 1 1 3 1 1 1 1 1 1 1
Ammonium chloride (NH4)Cl aqueous 1 1 1 2 1 1 1 1 1 1 3
Ammonium hydroxide NH3 + H2O 30 1 3 4 1 1 2 1 - 1 - 1
Aniline C6H7N 100 1 3 4 1 2 4 4 4 1 4 1
Anisole C7H8O 100 3 4 4 1 4 4 2 - 1 4 1
Antimony trichloride SbCl3 90 1 4 1 4 1 - 1 - 1 - 4
Benzaldehyde C7H6O 100 1 3 4 1 1 3 4 4 1 4 1
Benzene C6H6 100 3 2 4 1 3 4 4 - 1 4 1
Boric acid H3BO3 aqueous 1 3 1 2 1 - - - 1 1 1
Butyl acrylate C7H12O2 100 1 2 4 2 3 4 4 4 1 - 1
Butyl alcohol, normal C4H10O 100 1 1 2 1 1 2 2 4 1 1 1
Calcium chloride CaCl2 alcoholic 1 4 2 3 1 - - 4 1 1 3
Carbon disulfide CS2 100 4 3 4 2 4 4 4 4 1 3 1
Carbon tetrachloride
CCl4 100 4 4 4 2 4 4 4 4 1 3 1
(TETRA)
Chlorine Cl2 100 4 4 4 4 4 4 4 4 1 - 3
Chlorine water Cl2 x H2O 3 4 4 4 3 - 3 3 1 - 4
Chlorobenzene C6H5Cl 100 3 4 4 1 3 4 4 4 1 4 1
Chloroform CHCl3 100 3 3 4 4 3 4 4 4 1 4 3
11 Appendix
Acrylonitrile-butadiene-
Polytetrafluorethylene
Polyoxymethylene
- no data
Polycarbonate
Polypropylene
Concentration
1 resistant
Polyethylene
High Density
Polysulfone
caoutchouc
2 practically resistant
Aluminium
Polyamide
3 partially resistant
4 not resistant
HDPE
PTFE
POM
NBR
PSU
PVC
PVC
[%]
PC
PA
PP
AL
Medium Formula
Chromic acid CrO3 10 1 4 2 4 1 4 1 - 1 4 1
Chromic potassium KCr(SO4)2 x
saturated 1 2 1 3 1 - 1 - 1 - 3
sulphate 12H2O
Citric acid C6H8O7 10 1 1 1 2 1 1 1 1 1 1 1
Citric acid C6H8O7 50 1 3 1 2 1 - - - 1 1 1
Copper sulphate CuSO4 x 5H2O 10 1 1 1 1 1 1 1 1 1 1 4
Cyclohexanol C6H12O 100 1 1 3 1 1 1 1 4 1 2 1
Decane C10H22 100 - 1 2 1 3 - - - 1 2 1
Diaminoethane C2H8N2 100 1 1 3 1 1 - 3 4 1 1 1
Diesel fuel 100 1 1 3 1 1 - 1 3 1 1 1
Dimethyl formamide
C3D7NO 100 1 1 4 1 1 4 3 - 1 3 1
(DMF)
Dimethyl sulfoxide
C2H6SO 100 1 2 4 1 1 4 4 - 1 - 1
(DMSO)
Dimethylaniline C8H11N 100 - 3 4 2 4 - - - 1 - 1
Dioxane C4H8O2 100 2 1 4 1 3 2 3 4 1 3 1
Dipropylene glycol
C4H10O 100 3 1 4 1 4 4 4 4 1 - 1
(mono)methyl ether
Ethyl acetate C4H8O2 100 1 1 4 1 1 4 4 4 1 4 1
Ethylene chloride C2H4Cl2 100 3 3 4 1 3 4 4 4 1 - 1
Ferrous chloride FeCl2 saturated 1 3 1 3 1 1 1 1 1 - 4
Formaldehyde solution CH2O 30 1 3 1 1 1 - - - 1 2 1
Formic acid CH2O2 100 1 4 3 4 1 3 3 1 1 2 1
Furfural C5H4O2 100 1 3 3 2 4 - - - 1 4 1
Gasoline C5H12 - C12H26 100 2 1 3 1 3 3 2 - 1 1 1
Glycerol C3H8O3 100 1 1 3 1 1 1 1 2 1 1 1
Heptane, normal C7H16 100 2 1 1 1 2 1 2 4 1 1 1
Hexane, n- C6H14 100 2 1 2 1 2 1 2 4 1 1 1
Hydrogen chloride HCl 5 1 4 1 4 1 1 1 - 1 2 4
Hydrogen chloride HCl concentrated 1 4 4 4 1 1 2 3 1 4 4
Hydrogen peroxide H2O2 3 1 3 1 1 1 1 1 - 1 3 3
Hydrogen peroxide H2O2 30 1 4 1 4 1 1 1 - 1 3 3
Hydrogen sulphide H2S 10 1 1 1 1 1 1 1 3 1 3 1
Iodine, tincture of I2 1 4 3 1 1 - 4 4 1 1 1
11 Appendix
Acrylonitrile-butadiene-
Polytetrafluorethylene
Polyoxymethylene
- no data
Polycarbonate
Polypropylene
Concentration
1 resistant
Polyethylene
High Density
Polysulfone
caoutchouc
2 practically resistant
Aluminium
Polyamide
3 partially resistant
4 not resistant
HDPE
PTFE
POM
NBR
PSU
PVC
PVC
[%]
PC
PA
PP
AL
Medium Formula
Isopropyl alcohol C3H8O 100 1 1 1 1 1 1 1 4 1 - 2
Lactic acid C3H6O3 3 1 3 1 2 1 1 2 - 1 1 1
Magnesium chloride MgCl2 10 1 1 1 1 1 1 1 1 1 1 1
Mercuric chloride HgCl2 10 1 4 1 3 1 1 1 1 1 1 4
Mercury Hg 100 1 1 1 1 1 1 1 3 1 1 3
Methyl acetate C3H6O2 100 1 1 4 2 1 - 4 4 1 - 1
Methyl alcohol CH4O 100 1 2 4 1 1 3 1 3 1 2 1
Methyl benzene C7H8 100 3 1 4 1 3 4 4 4 1 4 1
Methyl ethyl ketone
C4H8O 100 1 1 4 1 1 4 4 4 1 4 1
(MEK)
Methylene chloride CH2Cl2 100 4 3 4 3 3 4 4 4 1 - 1
Mineral oil 100 1 1 1 1 1 1 1 - 1 1 1
Nitric acid HNO3 10 1 4 1 4 1 1 1 - 1 4 3
Nitric acid HNO3 100 4 4 4 4 4 - 4 - 1 4 1
Nitrobenzene C6H5NO2 100 3 4 4 3 2 4 4 4 1 4 1
Oleic acid C18H34O2 100 1 1 1 2 1 - 1 - 1 3 1
Oxalic acid C2H2O4 x 2H2O 100 1 3 1 4 1 1 1 1 1 2 1
Ozone O3 100 3 4 1 4 3 1 1 - 1 4 2
Petroleum 100 1 1 3 1 1 1 1 3 1 1 1
Phenol C6H6O 10 1 4 4 4 1 4 1 3 1 3 1
Phenol C6H6O 100 2 4 4 4 1 3 4 3 1 3 1
Phosphoric acid H3PO4 20 1 4 2 4 1 - - - 1 2 4
Phosphorus
PCl5 100 - 4 4 4 1 - 4 4 1 - 1
pentachloride
Potassium hydrogen
CHKO3 saturated 1 1 2 1 1 - - - 1 - 4
carbonate
Potassium hydroxide KOH 30 1 1 4 3 1 1 1 1 1 - 4
Potassium hydroxide KOH 50 1 1 4 3 1 1 1 1 1 - 4
Potassium nitrate KNO3 10 1 1 1 1 1 - - - 1 1 1
Potassium
KMnO4 100 1 4 1 1 1 - 1 - 1 3 1
permanganate
Pyridine C5H5N 100 1 1 4 1 3 4 4 4 1 4 1
Resorcinol C6H6O2 5 1 4 2 3 1 4 2 - 1 - 2
Silver nitrate AgNO3 100 1 1 1 1 1 1 1 1 1 2 4
11 Appendix
Acrylonitrile-butadiene-
Polytetrafluorethylene
Polyoxymethylene
- no data
Polycarbonate
Polypropylene
Concentration
1 resistant
Polyethylene
High Density
Polysulfone
caoutchouc
2 practically resistant
Aluminium
Polyamide
3 partially resistant
4 not resistant
HDPE
PTFE
POM
NBR
PSU
PVC
PVC
[%]
PC
PA
PP
AL
Medium Formula
Sodium bisulphite NaHSO3 10 1 1 2 4 1 - - - 1 1 1
Sodium carbonate Na2CO3 10 1 1 1 1 1 - - - 1 - 3
Sodium chloride NaCl 30 1 1 1 1 1 1 1 1 1 1 3
Sodium hydroxide NaOH 30 1 1 4 1 1 1 1 1 1 2 4
Sodium hydroxide NaOH 50 1 1 4 1 1 1 1 - 1 2 4
Sodium sulfate Na2SO4 10 1 1 1 1 1 1 1 1 1 1 1
Spirits C2H6O 96 1 1 1 1 1 1 1 3 1 - 1
Styrene C8H8 100 4 1 4 1 3 - 4 4 1 4 1
Sulphuric acid H2SO4 6 1 4 1 4 1 1 1 - 1 2 3
Sulphuric acid H2SO4 fuming 4 4 4 4 4 4 4 4 1 4 3
Tallow 100 1 1 1 1 1 - 1 1 1 1 1
Tetrahydrofuran (THF) C4H8O 100 3 1 4 1 3 4 4 4 1 3 1
Tetrahydronaphthalene C10H12 100 3 1 4 1 4 4 4 4 1 - 1
Thionyl chloride Cl2SO 100 4 4 4 2 4 4 4 4 1 - 3
Tin chloride SnCl2 10 1 4 2 2 1 - - - 1 1 4
Transformer oil 100 1 1 3 3 1 1 1 - 1 1 1
Trichloroethane C2H3Cl3 100 3 3 4 2 4 4 4 4 1 4 4
Urea CH4N2O 10 1 1 1 1 1 - - - 1 1 1
Urine 100 1 1 1 1 1 - 1 1 1 - 2
Vinegar C2H4O2 10 1 4 1 1 1 1 1 1 1 2 1
Vinegar C2H4O2 90 1 4 4 4 1 3 1 4 1 - 1
Wax 100 - 1 1 1 - - - 1 - 1
Wines 100 1 1 1 2 1 1 1 1 1 - 4
Xylene C8H10 100 3 1 4 1 4 4 4 4 1 4 1
Pos : 196 /010 Uni vers almodul e/Seitenwechs el @ 0\mod_1202116244312_0.doc x @ 105 @ @ 1
11 Appendix
Pos : 197 /100 Sig ma/110 BA Z entrifugen Sig ma (Proj ekte)/1-14_1- 14K/110 Anhang/110- 0060 Konfor mitts er klr ung 1-14 @ 28\mod_1405320897370_68.doc x @ 195755 @ 2 @ 1
11 Appendix
11 Appendix
Index
12 Index
A Contamination...................................... 19, 40
Continuous heat resistance ........................ 42
Acceleration time
Continuous run .......................................... 33
- see also the softstart and softstop function
............................................................ 33 Copyright ................................................... 10
Accessories, cleaning and care.................. 40 Corrosion ................ 18, 21, 29, 39, 40, 41, 42
Acid................................................ 20, 39, 41 Cost estimate ............................................. 45
Adapters .................................................... 40 Cracking .................................................... 40
Alkaline solutions ........................... 20, 39, 41 Cracks ....................................................... 41
Ambient conditions..................................... 48 Customer-provided fuses ........................... 25
Ambient temperature ................................. 48 D
Anodised coating ....................................... 40 Damage of the surface ............................... 41
Application examples ................................. 13 Dangerous goods....................................... 20
Autoclaving ................................................ 43 Dangerous materials .................................. 42
C Deceleration time
Capacity ..................................................... 48 - see also the softstart and softstop function
............................................................ 33
Capillary tubes ........................................... 28
Declaration of conformity ..................... 10, 59
CE mark in compliance with the directive
2006/42/EC ............................................ 15 Declaration of decontamination .................. 45
Centrifugation of infectious, toxic, radioactive, Declaration of Decontamination ................. 47
or pathogenic substances ....................... 19 Decontamination agent ........................ 40, 42
Centrifugation principle .............................. 13 Deformation of tubes.................................. 43
Centrifugation with low capacity ................. 29 Density....................................................... 20
Centrifuge cannot be started ...................... 35 Depth ......................................................... 48
Centrifuge decelerates during operation .... 35 Different service life of rotors and accessories
Centrifuge, cleaning and care .................... 39 ......................................................... 21, 53
Centrifuges Dimensions and weight .............................. 23
- definition ................................................. 9 Direct hazard to the life and health ............. 16
Changes in colour ...................................... 43 Directive 2002/96/EC ................................. 47
Changes in structure .................................. 43 Disinfectants .............................................. 42
Changing the runtime during centrifugation 32 Disinfection of the rotor chamber and
accessories ............................................ 42
Changing the Speed/RCF Value during
Centrifugation ......................................... 31 Disposal of the centrifuge........................... 47
Chemical and biological safety ................... 19 Disposal of the packaging .......................... 47
Chemical resistance of plastic .................... 41 Documentation ........................................... 10
Cleaning agents ......................................... 42 E
Cleaning the bores of angle rotors ............. 40 EC declaration of conformity ................ 10, 59
Cleaning the centrifuge .............................. 39 EEPROM error ........................................... 37
Closing the lid ...................................... 18, 26 Electrical connection .................................. 48
Communication error ................................. 37 Electrical safety .......................................... 18
Condensation............................................. 25 Emergency lid release ............................... 36
Connected load .......................................... 48 Error correction .......................................... 35
Connection cable ....................................... 10 Error messages ......................................... 35
Index
Explanation of the symbols and notes ........ 16 Lid lock is not closed correctly.................... 35
Explosive substances ................................ 19 M
F Mains power switch off ............................... 35
Fatal error .................................................. 35 Mains voltage............................................. 18
Fire preventions ......................................... 19 Maintenance .............................................. 39
Form for the return of defective parts ......... 45 Malfunction ................................................ 35
Functional and operating elements ............ 11 Malfunctions and error correction ............... 35
G Manufacturer.............................................. 48
Marking of the unit ..................................... 15
General conditions ....................................... 9
Max. capacity ............................................. 48
General malfunctions ................................. 35
Max. current consumption .......................... 48
Glass breakage .......................................... 42
Max. gravitational field ............................... 48
Glass particles ........................................... 42
Max. speed ................................................ 48
Gravitational field ................................. 28, 48
Measures in the event of hazards and
Grease for load bearing bolts ..................... 39
accidents ................................................ 22
H Mechanical safety ...................................... 18
Hazard warnings .............................. 9, 27, 29 Microhaematocrit rotor ......................... 28, 41
Height ........................................................ 48 Mode of operation ...................................... 13
Highly corrosive substances ...................... 18 Motor error ................................................. 37
I Motor shaft ..................................... 27, 28, 39
Imbalance .................................................. 29 N
Imbalance error .......................................... 37 Name plate ................................................ 12
Importance of the operating manual ............. 9 No indication on the display ....................... 35
Important information ................................. 16 No power in the mains supply .................... 35
Infectious substances ................................ 42 Noise level ................................................. 48
Inflammable substances ............................ 19 Notes on safety and hazards ....................... 9
Informal safety instructions ........................ 17 Notes on transport ..................................... 23
Initial start-up ............................................. 26 O
Inspection by the manufacturer .................. 44
Online download of forms .......................... 46
Installation of accessories .......................... 29
Opening the lid ........................................... 26
Installation of rotors and accessories ......... 27
Operating personnel .................................. 17
Installation of the microhaematocrit rotor ... 28
Operating voltage....................................... 25
Installation of the rotor ............................... 27
Operational safety ...................................... 40
Installation site ........................................... 25
Overseas shipping ..................................... 23
Intended use ................................................ 9
P
Interrupting a centrifugation run ................. 31
Interrupting a deceleration process ............ 31 Packaging .................................................. 24
IP code ...................................................... 48 Parameter .................................................. 28
Parameter error ......................................... 37
L
Pathogenic substances .................. 19, 39, 42
Layout of the centrifuge.............................. 11
Performance data ...................................... 48
Leaks ......................................................... 43
Plastic accessories, cleaning and care....... 41
Lid error ..................................................... 37
Potential hazard to the life and health ........ 16
Lid is not closed correctly ........................... 35
Potentially hazardous situation................... 16
Lid lock device ........................................... 22
Power consumption ................................... 48
Version 08/2012, Rev. 3.10 of 06/04/2016 sb
62 / 64
Translation of the original operating manual, part no. 0700002
Laboratory centrifuge Sigma 1-14
Index
Power cord is not plugged in ...................... 35 Service life ................................................. 39
Power supply ............................................. 25 Service life of rotors and accessories ... 21, 53
Pressure marks .......................................... 41 Service life of the accessories .................... 43
Prevention of accidents ................................ 9 Service work .............................................. 44
Problem description ................................... 45 Set-up and connection ............................... 25
Process error ............................................. 37 Short run .................................................... 32
Protection class ................................... 25, 48 Softstart and softstop function .................... 33
Q Solvents ......................................... 20, 39, 41
Spanner for emergency lid release ...... 10, 36
Quick run ................................................... 32
Spare part enquiries................................... 38
R
Speed ............................................ 14, 31, 48
Radioactive substances ....................... 19, 39 Speed-gravitational-field-diagram .............. 52
Radius ....................................................... 14 Speedometer error ..................................... 37
Range of accessories ................................ 50 Spincontrol Basic ....................................... 30
RCF ........................................................... 31 Standards and regulations ......................... 10
Relative centrifugal force (RCF) ........... 14, 31 Starting a centrifugation run ....................... 31
Remove glass particles and metal dust from Sterilisation of the rotor chamber and
the rotor chamber ................................... 42 accessories ............................................ 42
Responsibility of the operator ..................... 17 Storage and transport ................................ 23
Return of centrifuges, spare parts, or Storage conditions ..................................... 23
accessories ............................................ 45
Stress-corrosion
Return of defective parts ............................ 45
see
Risk of electrical shock............................... 18
corrosion ............................................. 41
Rotor chamber ........................................... 39
Structural changes ..................................... 19
Rotor fastening nut......................... 10, 27, 28
Supply voltage ........................................... 25
Rotor radii .................................................. 51
Switching the centrifuge off ........................ 34
Rotor selection ........................................... 34
System check ............................................ 22
Rotors and accessories with a different
System error .............................................. 37
service life ........................................ 21, 53
Rotors, cleaning and care .......................... 41 T
Runtime ..................................................... 32 Table of error codes ................................... 37
S Table of rotors and accessories with a
different service life .......................... 21, 53
Safety area ................................................ 20
Technical data ........................................... 48
Safety devices ........................................... 22
Technical documentation ........................... 49
Safety distance .............................. 18, 20, 25
Temperature error ...................................... 37
Safety instructions............................ 9, 27, 29
Temperature value cannot be reached....... 35
Safety instructions for centrifugation .......... 20
Thermal stress ........................................... 39
Safety, chemical and biological .................. 19
Time range................................................. 48
Safety, electrical ........................................ 18
Toxic substances ................................. 19, 39
Safety, mechanical..................................... 18
Transport safety device .............................. 24
Safety-conscious work ............................... 17
Type........................................................... 12
Scope of supply ......................................... 10
Type of connection..................................... 25
Serial number ................................ 12, 38, 44
Type of the centrifuge .................... 38, 44, 48
Service ....................................................... 44
U
Service contact .......................................... 38
Units of protection class I ........................... 25
Version 08/2012, Rev. 3.10 of 06/04/2016 sb
63 / 64
Translation of the original operating manual, part no. 0700002
Laboratory centrifuge Sigma 1-14
Index
User interface ............................................ 30 Wear .......................................................... 44
UV radiation ......................................... 25, 39 Weight ....................................................... 48
V Width ......................................................... 48
Work on the power supply system ............. 18
Vents ......................................................... 25
Y
W
Year of manufacture .................................. 12
Warranty and liability .................................... 9