Вы находитесь на странице: 1из 6

FIELD Quality Plan

Sewage Treatment Plant


and Intermediate Sewage p
KEC-WATERLEAU (JV) QP.No-1 REV.no-0
Sa

FIELD QUALITY ASSURANCE DEPARTMENT

TEST FOR SOLID BLOCKS

DATE :
AGENCY SMCIPL
MATERIAL SOLID BLOCKS
SOURCE AAPCO CONCRETE BLOCKS
LOCATION : 20 MLD Doddabele site

AS PER IS 2185-PART-1-2005
DIMENSION OF WATER
DATE OF DRY MASS IN WET MASS DENSITY IN DATE OF
S.NO. THE BLOCKS IN ABSORPTION IN
TESTING KG (B) IN KG (A) KG/M3 TESTING
mm % (A-B/B)*100

1 400x200x200

2 400x200x200

3 400x200x200

4 400x200x200

5 400x200x200

1 400x200x100

2 400x200x100
3 400x200x100

4 400x200x100

5 400x200x100

NOTE : 1) As per 2185-1-2005 water absorption not more than 10%


2) As per 2185-1-2005 Density not less than 1800 kg/m 3

3)As per 2185-1-2005 D(5.0) minimum average strength 5 N/mm2, minimum


individual strength 4 N/mm2 & D(4.0) minimum average strength 4 N/mm2,
minimum individual strength 3.2 N/mm2

Tested By :-
SMC

For KEC waterleu NMT


Quality Plan
Sewage Treatment Plants at Doddabele,Yellamalappachetty
and Intermediate Sewage pumping Station and Pumping Mains at
Sadarmangala

E DEPARTMENT

LOCKS

185-PART-1-2005
AVG.
COMPRESSIVE COMPRESSIVE
LOAD IN KN STRENGTH IN STRENGTH IN GRADE
N/MM2 N/MM2
BWSSB
AS PER IS 2185-PART-1-2005
SIZE OF THE WATER
S.NO. DATE OF DRY MASS WET MASS ABSORPTION
BLOCKS IN IN DENSITY3 IN LOAD IN KN
TESTING IN KG (B) IN KG (A) % (A-B/B)*100 KG/M
mm

400x200x100 18.1 18.8 3.87


2262.50 250
400x200x100 18.2 18.95 4.12
2275.00 300
400x200x100 18.2 18.95 4.12
2275.00 250
400x200x100 18 18.8 4.44
2250.00 325
400x200x100 17.75 18.45 3.94
2218.75 285
400x200x200 34.75 36.85 6.04
2171.88 120
400x200x200 35.15 36.4 3.56
2196.88 100
400x200x200 35.45 36.85 3.95
2215.63 100
400x200x200 34.9 36.2 3.72
2181.25 100
400x200x200 3.78
34.35 35.65 2146.88 50
-2005
COMPRESSIVE AVG.COMPRESSIVE
STRENGTH IN STRENGTH IN GRADE
N/MM2 N/MM2

11.11

13.33
12.53 C (5.0)
11.11

14.44

12.67

5.33

4.44
4.18 C (4.0)
4.44

4.44

2.22

Вам также может понравиться