probe Mixer design Liquid level detection Avoid cross contamination Function after dispending of Collision protection sample or second reagent Pre-heating the reagent With 3 different mixing speed Probe depth adjustment Probe depth adjustment
Excellent reaction tray Intelligent Software
Temperature control at 37 Real-time online help system +0.1 Use-friendly operation interface High quality cuvette Automated washing system Multi-media operation software 8-step auto-washing with 3 kinds of different detergents MHS-200 Chemistry Analyzer Technical Specifications and outside, Carry over0.1% Reaction system : System Function : Reaction tray: 48 reaction cuvettes Automatic, discrete, random access Reaction technology: Chemistry analyzer Back-Dividing-Light technology Throughput: 200 tests/h ,up to 280 tests/h with Reaction volume: 200~300ul ISE(optional) Reaction Temperature:37+0.1 Measuring Principles: Mixing system: Independent mixing probe Absorbance photometry, turbidimetry, ISE Optical system : technology. Light source: Halogen-tungsten lamp Methodology: end point ,fixed-time, kinetic, Wavelength:340nm,405nm,450nm,494nm Immunoturbidimetry ,Monochromatic, bi- 505nm,546nm,578nm,620nm chromatic& Multi-standard Analysis 670nm,700nm Linearity& Nonlinearity Calibration Linear range:0~3ABS Single &Dual Reagent can be used Control and Calibration system : Programming: Open system with user defined Calibration mode: Linear(one point ,two point profiles and calculations and multi-point),Logit-Log4P, Logit-Log 5P, Sample system : spline, exponential ,polynomial, parabola Sample tray: 44 sample position Control rules: Westgard multi-rule Sample volume:3~30ul, programmed by 0.1ul Operation Unit step Operation system: Windows2000 system or above Sample probe: Liquid level detection and Interface: RS-232 Collision protection automatically Working Conditions Probe cleaning: automatic washing both inside Power Supply: 220V+22V, 50/60HZ+1HZ and outside, Carry over0.1% Power consumption: 400VA Automatic sample dilution Temperature:15~30 Reagent system: Humidity: 85% Reagent tray: 44 positions for single &dual Water consumption: 5L/h Reagents. Dimension:760(L)X570(W)X1000MM Refrigeration: Refrigerated reagent Weight: approx.85kgs Compartment 24h Cooling system maintaining temperature 4~15 Reagent bottle size: 20ml and 35ml Reagent volume:150~300ul,programmed by 0.1ul step Reagent probe: Liquid level detection and MH MEDICAL CO., LTD collision protection automatically ADD: UNIT 1308 WEALTH DOMAIN PLAZA, 207 RENMIN STR. CHANGCHUN CHINA Pre-heating function inventory checking. TEL: 0086-431-81948048 Real-time monitoring of reagent volume FAX: 0086-431-81948049 and auto alarm Email: info@mhmedical.cn www.mhmedical.cn Probe cleaning: automatic washing both inside