Вы находитесь на странице: 1из 6

Sylodyn ND

Material Data Sheet

Material closed cellular polyurethane Standard Sylodyn range


Colour green

Standard dimensions on stock


Thickness: 12.5 mm with Sylodyn ND 12 NF
25 mm with Sylodyn ND 25
Rolls: 1.5 m wide, 5.0 m long
NE
Stripes: max. 1.5 m wide, up to 5.0 m long

Other dimensions (also thickness) as well as stamped and molded


parts on request. ND

Area of application Compression load Delection NC


(depending on form factor)

Static load limit up to 0.35 N/mm2** approx. 10 %**


Operating load range up to 0.50 N/mm ** 2
approx. 16 %** NB
(static plus dynamic loads)
Load peaks up to 4.0 N/mm2** approx. 60 %**
(short term, infrequent loads)

10 1 0.1 0.01 0.001


Static load limit [N/mm2]

Material properties Test methods Comment


Tensile stress at break 2.5 N/mm2 DIN EN ISO 527-3/5/100* minimum value
Elongation at break 500 % DIN EN ISO 527-3/5/100* minimum value
Tear strength 10 N/mm DIN 53515* minimum value
3
Abrasion 100 mm DIN 53516 load 10 N, bottom surface
Coeficient of friction (steel) 0.7 Getzner Werkstoffe dry
Coeficient of friction (concrete) 0.7 Getzner Werkstoffe dry

Compression set <5% EN ISO 1856 50 %, 23 C, 70 h, 30 minutes after unloading


2
Static shear modulus 0.35 N/mm DIN ISO 1827* at static load limit

Dynamic shear modulus 0.47 N/mm2 DIN ISO 1827* at static load limit
Mechanical loss factor 0.08 DIN 53513* depending on frequency, load and amplitude (reference value)

Rebound elasticity 70 % DIN 53512 tolerance +/- 10 %


Operating temperature -30 to 70 C short term higher temperatures possible
Flammability B2 DIN 4102 normal lammable
class E EN ISO 11925-2 EN 13501-1
Speciic volume resistance > 1011 cm DIN IEC 93 dry

Thermal conductivity 0.09 W/[mK] DIN 52612/1

Further characteristic values on request All information and data is based on our current knowledge. The data can be applied for calculations and as
guidelines, are subject to typical manufacturing tolerances, and are not guaranteed.
* Tests according to respective standards We reserve the right to amend the data.
** At form factor q=3
Further information can be found in VDI Guidline 2062 Page 2.

www.getzner.com

1
Sylodyn ND

Load delection curve

Full surface bearing Form factor: q=6


0.8

Speciic load [N/mm2]


12.5 mm 25 mm
37.5 mm

Operating load range


0.6
50 mm

0.4
Static
load limit

0.2

0
0 1 2 3 4 5 6 7 8 9 10 11 12
Delection [mm]

Strip bearing Form factor: q=3


Speciic load [N/mm2]

0.8

12.5 mm 25 mm
37.5 mm
0.6

Operating load range


50 mm

0.4
Static
load limit

0.2

0
0 1 2 3 4 5 6 7 8 9 10 11 12
Delection [mm]

Point bearing Form factor: q=1.5


0.8
Speciic load [N/mm2]

12.5 mm 25 mm

0.6
37.5 mm
Operating load range

50 mm

0.4

Static
load limit

0.2

0
0 1 2 3 4 5 6 7 8 9 10 11 12
Delection [mm]

www.getzner.com Quasi-static load delection curve measured at a velocity of deformation


of 1 % of the thickness per second; testing between lat steel-plates;
recording of the 3rd loading; testing at room temperature

2
Modulus of elasticity Natural frequency

Form factor: q=6 Form factor: q=6


6 0.8
E-modulus [N/mm2]

Speciic load [N/mm2]


30 Hz 0.6

4 10 Hz

0.4

50 mm

2
37.5 mm
Static
0.2
25 mm

12.5 mm

0 0
0 0.2 0.4 0.6 0.8 0 5 10 15 20 25
Speciic load [N/mm2] Natural frequency [Hz]

Form factor: q=3 Form factor: q=3


6 0.8
E-modulus [N/mm2]

Speciic load [N/mm2]

0.6
30 Hz
4

10 Hz

0.4

50 mm
2
37.5 mm
Static 0.2

25 mm

12.5 mm
0 0
0 0.2 0.4 0.6 0.8 0 5 10 15 20 25
Speciic load [N/mm2] Natural frequency [Hz]

Form factor: q=1.5 Form factor: q=1.5


0.8
E-modulus [N/mm2]

Speciic load [N/mm2]

0.6

4 30 Hz

10 Hz
0.4

2 50 mm

0.2 37.5 mm
Static
25 mm

12.5 mm
0 0
0 0.2 0.4 0.6 0.8 0 5 10 15 20 25
Speciic load [N/mm2] Natural frequency [Hz]

Static modulus of elasticity as a tangent modulus taken from the load Natural frequency of a single-degree-of-freedom system (SDOF system)
delection curve; dynamic modulus of elasticity due to sinusoidal excitation consisting of a ixed mass and an elastic bearing consisting of Sylodyn ND
with a velocity level of 100 dBv re. 510-8 m/s; test according to DIN 53513 based on a stiff subgrade; parameter: thickness of elastomeric bearing

3
Vibration isolation eficiency
200
Disturbing frequency [Hz]

180
-40 dB/99 % Reduction of the transmitted
-30 dB/97 % mechanical vibrations by implemen-
160
tation of an elastic bearing
140
consisting of Sylodyn ND
-20 dB/90 %
120 Parameter: factor of transmission in
100 dB, isolation rate in %
80 -10 dB/69 %

60
-0 dB/0 %
40

20

0
5 10 15 20 25 30 35 40 45 50
Natural frequency [Hz]

Creep behaviour
Relative deflection [% of thickness with unstressed sample]

25
Increase in deformation under
consistent loading
20
Parameter: permanent loading
100 % load
Form factor: q=3
15

10

50 % load

1d 1m 1a 10 a
0
0.1 1 10 100 1,000 10,000 100,000 1,000,000
Period of loading [h]

Dynamic E-modulus at long term loading


Dyn. E-modulus [N/mm2]

6
Change of dynamic modulus of
5 100,000 h elasticity under consistent loading
1,000 h (at 10 Hz)
4 Parameter: load duration
Form factor: q=3
10 h
3
0.1 h

0
0 0.4 0.8
Permanent loading [N/mm2]

www.getzner.com

4
Temperature dependency
Dyn. E-modulus [N/mm2]

Mechanical loss factor


6 0.5 DMA-test
(Dynamic Mechanical
Analysis); tests within
5 linear area of the
0.4 load delection curve,
at low speciic loads
4
30 Hz
0.3
10 Hz
3

0.2
2 30 Hz

0.1 10 Hz
1

0 0
-10 0 10 20 30 40 50 -10 0 10 20 30 40 50
Temperature [C] Temperature [C]

Frequency dependency
0.5
Mechanical loss factor
Dyn. E-modulus [N/mm2]

5 DMA-tests; mastercurve
with a reference-tempera-
ture of 21 C;
tests within the linear area
4 0.4 of the load delection curve,
at low speciic loads

3 0.3

2 0.2

1 0.1

0 0
1 10 100 1,000 1 10 100 1,000
Frequency [Hz] Frequency [Hz]

Dependency on amplitude Dependency on loading velocity


0.8
Dyn. E-modulus [N/mm2]

Speciic load [N/mm2]

6
Dependency on amplitude:
preload at static load limit;
Form factor: q=3, thickness
of material 25 mm
0.6 0.035 N/mm2/s
Dependency on loading
30 Hz
velocity:
4 0.35 N/mm2/s Form factor: q=3, thickness
of material 25 mm
10 Hz 3.5 N/mm2/s
0.4

0.2

0 0
0.01 0.10 1.00 0 1 2 3 4 5 6 7 8 9 10 11 12
Amplitude [mm] Delection [mm]

www.getzner.com

5
Form factor
The form factor is a geometric measure for the shape of Loaded area
an elastomeric bearing deined as the ratio of the loaded
area and the area of sum of the perimeter surfaces.

Loaded area
Deinition: Form factor =
Perimeter surface area
Perimeter
surface area
Iw
For a rectangular shape: q =
2t(I+w)
(l..length, w..width, t..thickness)
Perimeter surface area

The form factor has an inluence on the delection and


the static load limit respectively.

Elastic Sylodyn-bearings are considered as


Full surface bearing: Form factor > 6
Strip bearing: Form factor between 2 and 6
Point bearing: Form factor < 2

Inluence of the form factor on the delection at the Inluence of the form factor on the static load limit
static load limit for a homogeneous material for a homogeneous material
Reference value: Form factor q=3 Reference value: Form factor q=3
Deviation of delection [%]

Static load limit [N/mm2]

50 % 0.4

40 %

Increase of Increase of
30 %
delection static load limit
0.3

20 %
DB SN ND en Copyright by Getzner Werkstoffe GmbH l 09-2014

Decrease of
10 % static load limit

0.2
0%
Decrease
of delection
-10 %
We reserve the right to amend the data.

-20 % 0.1
0 1 2 3 4 5 6 0 1 2 3 4 5 6
Form factor Form factor

AUSTRIA Brs GERMANY Berlin Munich FRANCE Lyon JORDAN Amman JAPAN Tokyo
INDIA Pune CHINA Beijing USA Charlotte www.getzner.com
6