Step 1:
Note: some conditions of the sensors will cause a system lock up and
"font seek error" along with other sensor errors will occur not
allowing you into the diagnostics. If this happens you may have to put
a volt meter on the rear transistors for each sensor after cleaning and
monitor the voltage change while adjusting the pots on the PCB.
(+30Vdc then Changes with Document blocking sensor/ Front Led has
+5vdc on it)
Step 2:
Maverick 210 Encoder 210 Clone to
Maverick 610 By BrainWaveTech Copyright 2010
Then
Press "TEST" (Hold) then the "00" keys- Display shows "Drop
Document"
*For Font Alignment: Use "di" 91 (Centers Font Character from left to
right for best quality)
EXAMPLE:
Press 91
The FONT Wheel Alignment memory has now been changed from
1349 to 1360
Then
Press "TEST" (Hold) then the "00" keys- Display shows "Drop
Document"
You have the cloning cable. I am attaching some good information. Print out the
quick reference.
Maverick does not supply cloning instructions so I got you some good
information, it is the same for 210 as 610.
Any Maverick 210 program can be cloned into a newer Maverick 610
unit.
PC system requirements:
Parallel Port
Serial Port
Dos, windows 95 or 98, XP only (no 2000)
Maverick Kermit Serial Cable: The Maverick cable 039-90065-1 combined with a
DB-9 female to female "gender-bender" will work for downloading.
WEBSITE ACCESS:
http://www.mav.com/dealer/saleschannels.cfm
ACE program(PC ACE PROGRAM)-Used to save and load files in
"DOS"
Load PC-Ace onto a laptop which can run dos (Win95,98XP ok) You
must have the cable sent to you hooked up to the parallel port when
running the program. Use the attached Maverick M210 ACE to
Maverick Procedure to get started. The programs can be uploaded or
downloaded from using the ACE program and are saved as ".MCR"
Files. This ACE program can be used for Maverick 1, 2 and 3 and 610
Any Maverick 210 program can be cloned into a newer Maverick 610
unit. There is a download port on the Maverick 210 at the right rear
under the small cover. There is a download port access through the
top assembly transport on the maverick 610. You need the cloning
cable p/n:074-90037-1
Note: Some conditions of the sensors will cause a system lock up and
"font seek error"along with other sensor errors will occur not
allowing you into the diagnostics the Top transport assembly
completely separate from the Maverick 210 main board to obtain
access to setting up the commands for a Transfer of program.
Maverick 210 Encoder 210 Clone to
Maverick 610 By BrainWaveTech Copyright 2010
Keep hitting "C" then try to insert "transfer Invoke" commands as fast
as possible before fault is displayed
Maverick 210
• Sensor adjustments no longer require a volt meter and are same concept as the
MICR 3 and MICR 5
Maverick 210 Encoder 210 Clone to
Maverick 610 By BrainWaveTech Copyright 2010
• Font sensor is located under the transport plate away from dust and operators