Вы находитесь на странице: 1из 8

Siemens AG 2007

IEC Squirrel-Cage Motors


Non-standard motors frame size 315 and above
Dimensions

Overview
Overall dimensions
L AD

G_D081_XX_00144
O

H
AB

Frame Type Number Dimensions Frame Type Number Dimensions


size of poles L AD H AB size of poles L AD H AB
315 1LA8 2 1380 570 315 680 400 1LA8 2 1795 865 400 860
1LA8 4, 6, 8 1410 570 315 680 1LA8 4, 6, 8 1835 865 400 860
1LA8 4, 6, 8 1) 1430 570 315 680 1PQ8 2 2148 865 400 860
1PQ8 2 1742 570 315 680 1PQ8 4, 6, 8 2188 865 400 860
1PQ8 4, 6, 8 1772 570 315 680 1LL8 2 1793 865 400 860
1PQ8 4 1) 1792 570 315 680 1LL8 4, 6, 8 1833 865 400 860
1LL8 2 1380 655 315 680 450 1LA8 2 1955 900 450 980
1LL8 4, 6, 8 1410 655 315 680 1LA8 4, 6, 8 1995 900 450 980
355 1LA8 2 1605 710 355 780 1PQ8 2 2308 900 450 980
1LA8 4, 6, 8 1635 710 355 780 1PQ8 4, 6, 8 2348 900 450 980
1LA8 4, 6, 8 1) 1700 710 355 780
1LL8 2 1953 900 450 980
1PQ8 2 1971 690 355 780 1LL8 4, 6, 8 1993 900 450 980
1PQ8 4, 6, 8 2001 690 355 780
1PQ8 4, 6, 8 1) 2065 690 355 780 For dimension O, see Introduction under Connection
1LL8 2 1605 840 355 780 boxes.
1LL8 4, 6, 8 1635 840 355 780

Notes on the dimensions


7 Dimension drawings according to DIN EN 50347 and 7 Dimension tolerances
IEC 60072. For the following dimensions, the permissible deviations are
7 Fits given below:
The shaft extensions specified in the dimension tables (DIN 748) Dimension designation Dimension Permitted
and centering spigot diameters (DIN EN 50347) are machined deviation
with the following fits: H over 250 1.0
Dimension designation ISO fit DIN ISO 286-2 E, EA 0.5
D, DA over 50 m6 Keyways and feather keyways (dimensions GA, GC, F and FA)
N over 250 h6 are made in compliance with DIN 6885 Part 1.
F, FA h9 7 All dimensions are specified in mm.
K H17
S Flange (FF) H17
The drilled holes of couplings and belt pulleys should have an
ISO fit of at least H7.

1)
With bearings for increased cantilever forces: Dimensions available on
request.

Siemens D 81.1 2007 3/57


Siemens AG 2007

IEC Squirrel-Cage Motors


Non-standard motors frame size 315 and above
Dimensions

Dimensional drawings
Cast-iron series 1LA8, frame sizes 315 to 450
Type of construction IM B3

LC
L AD
LL
HK
3

DA

FA
EB

HD
EC
F

AC
D

BE
BC

HB
GA GC

HA
AG

H
DB
G_D081_XX_00016
BA K DC K' AA
E C B CA EA A
BB AB

Type of construction IM V1
For flange dimensions, see Page 3/64 (Z = the number of retaining holes)
L Eyebolts frame size
HH 100 L and above
LL

H
C
K
H

H
B'
LM
G_D081_EN_00017

E
F

BE
AQ
AC
D

GA EB

'
AD
'
AG
DB

Connection box position


Basic version Special versions
G_D081_EN_00050

G_D081_EN_00051
G_D081_EN_00049

With cable entry from


above, protection
against rain and other
Cable entry: bottom Cable entry: top Cable entry: top adverse weather
Console: 0 degrees Console: 180 degrees Console: 0 degrees conditions must be
Order code: Order code: K85 Order code: plain text provided.
For motor Dimension designation acc. to IEC
Frame Type Number A AA AB AC 1) AD AD' AG AG' AQ B BA BB BC BE C CA H HA HB HB' HC
size of poles
315 1LA8 31 . 2 560 120 680 710 570 582 474 481 670 630 180 780 195 140 180 435 315 28 404 217 162
4, 6, 8 180
4, 6, 8 2) 200
355 1LA8 35 . 2 630 150 780 790 690 697 597 593 750 800 220 980 185 135 200 470 355 35 431 290 165
4, 6, 8 200
1LA8 357 2, 4 829 875 739 745 100 200 359 395 175
1LA8 35 . 4, 6, 8 2) 690 697 597 593 135 224 431 290 165
400 1LA8 40 . 2 710 150 860 880 865 925 775 795 850 900 220 1080 186 100 224 506 400 35 440 395 175
4, 6, 8
450 1LA8 45 . 2 3) 800 180 980 970 900 975 810 845 950 1000 260 1220 170 100 250 540 450 42 525 395 175
4, 6, 8
1) Measured across the bolt heads (not in the flattened area of the fan 2) With bearings for increased cantilever forces. No second shaft exten-
cowl). sion possible.
3) Only at 50 Hz.

3/58 Siemens D 81.1 2007


Siemens AG 2007

IEC Squirrel-Cage Motors


Non-standard motors frame size 315 and above
Dimensions

Dimensional drawings
Cast-iron series 1LA8, frame sizes 315 to 450
Type of construction IM B35
For flange dimensions, see Page 3/64 (Z = the number of retaining holes)
L C
L
A D
L L
H K 3
E E C

D A

F A

H D
F

A C
B E
D

G A E B B C G C
A G

H B
H A
H
D B D C
G _ D 0 8 1 _ X X _ 0 0 0 1 8
B A K
C B C A E A K ' A A
B B A
A B

Connection box position


Special versions
G_D081_EN_00052

G_D081_EN_00053

Cable entry: DE / NDE Cable entry: DE / NDE


Console: 0 degrees Console: 180 degrees
Order code: K83/K84 Order code: plain text

For motor Dimension designation acc. to IEC DE shaft extension NDE shaft extension
Frame Type Number HD HK K K' L LC LL LM D DB E EB F GA DA DC EA EC FA GC
size of poles
315 1LA8 31 . 2 783 170 26 33 1380 1495 307 1510 65 M20 140 125 18 69 50 M16 110 100 14 53.5
4, 6, 8 1410 1555 1540 85 M20 170 140 22 90 70 M20 140 125 20 74.5
4, 6, 8 1) 1430 1575 95 M24 170 140 25 100
355 1LA8 35 . 2 895 229 33 40 1605 1750 330 1745 75 M20 140 125 20 79.5 60 M20 140 125 18 64
4, 6, 8 1635 1810 1775 95 M24 170 140 25 100 80 170 140 22 85
1LA8 357 2, 4 945 320 550
1LA8 35 . 4, 6, 8 1) 1700 1874 100 M24 210 180 28 106
400 1LA8 40 . 2 1025 320 33 40 1795 1940 550 1945 80 M20 170 140 22 85 70 M20 140 125 20 74.5
4, 6, 8 1835 2010 1985 110 M24 210 180 28 116 90 M24 170 140 25 95
450 1LA8 45 . 2 2) 1110 320 39 47 1955 2100 550 2105 90 M24 170 140 25 95 75 M20 140 125 20 79.5
4, 6, 8 1995 2210 2145 120 210 180 32 127 100 M24 210 180 28 106
1) With bearings for increased cantilever forces. No second shaft exten-
sion possible.
2) Only at 50 Hz.

Siemens D 81.1 2007 3/59


Siemens AG 2007

IEC Squirrel-Cage Motors


Non-standard motors frame size 315 and above
Dimensions

Dimensional drawings
Cast-iron series 1PQ8, frame sizes 315 to 450
Type of construction IM B3

L HKI: connection box optional for


LL HKI pulse encoder AD
HKF: connection box for separately
3 driven fan

EB

HD
F

AC
D

BE
GA BC

HB
AG

HA
H
DB
G_D081_EN_00044
BA K HKF K AA
E C B A
BB AB
Type of construction IM V1
For flange dimensions, see Page 3/64 (Z = the number of retaining holes)
L HKI: connection box optional for pulse encoder
HH HKF: connection box for separately driven fan
LL
HKI

HC
HK
LM

HB
'
E
F

BE
AC

AQ
D

GA EB
DB

'
'
AG
AD
G_D081_EN_00045
HKF

Connection box position


Basic version Special versions
G_D081_EN_00050

G_D081_EN_00051
G_D081_EN_00049

With cable entry from


above, protection
against rain and other
Cable entry: bottom Cable entry: top Cable entry: top adverse weather
Console: 0 degrees Console: 180 degrees Console: 0 degrees conditions must be
Order code: Order code: K85 Order code: plain text provided.
For motor Dimension designation acc. to IEC
Frame Type Number of A AA AB AC 1) AD AD' AG AG' AQ B BA BB BC BE C
size poles
315 1PQ8 31 . 2 560 120 680 710 570 582 474 481 670 630 180 780 195 140 180
4, 6, 8 180
4, 6, 8 2) 200
355 1PQ8 35 . 2 630 150 780 790 690 697 597 593 750 800 220 980 185 135 200
35 . 4, 6, 8 200
1PQ8 357 2, 4 829 875 739 745 100 200
1PQ8 35 . 4, 6, 8 2) 670 697 597 593 135 224
400 1PQ8 40 . 2 710 150 860 880 865 925 775 795 850 900 220 1080 186 100 224
4, 6, 8
450 1PQ8 45 . 2 3) 800 180 980 970 900 980 810 845 950 1000 260 1220 170 100 250
4, 6, 8

1) Measured across the bolt heads (not in the flattened area of the fan 2) With bearings for increased cantilever forces.
cowl). 3) Only at 50 Hz.

3/60 Siemens D 81.1 2007


Siemens AG 2007

IEC Squirrel-Cage Motors


Non-standard motors frame size 315 and above
Dimensions

Dimensional drawings
Cast-iron series 1PQ8, frame sizes 315 to 450
Type of construction IM B35
For flange dimensions, see Page 3/64 (Z = the number of retaining holes)
HKI: connection box optional for
L pulse encoder
HKF: connection box for separately AD
HKI
LL
driven fan HK 3
E

HD
F

AC
D

BE
GA EB BC

HB
AG

HA
H
DB
G_D081_EN_00046
BA K HKF
C B K' AA
BB A
AB

Connection box position


Special versions
G_D081_EN_00052

G_D081_EN_00053

Cable entry: DE / NDE Cable entry: DE / NDE


Console: 0 degrees Console: 180 degrees
Order code: K83/K84 Order code: plain text
For motor Dimension designation acc. to IEC DE shaft extension
Frame Type Number of H HA HB HB' HC HD HK K K' L LL LM D DB E EB F GA
size poles
315 1PQ8 31 . 2 315 28 404 217 162 783 170 26 33 1742 307 1510 65 M20 140 125 18 69
4, 6, 8 1772 1540 85 M20 170 140 22 90
4, 6, 8 1) 1792 95 M24 170 140 25 100
355 1PQ8 35 . 2 355 35 431 290 165 896 229 33 40 1971 330 1745 75 M20 140 125 20 79.5
4, 6, 8 2001 1775 95 M24 170 140 25 100
1PQ8 357 2, 4 359 395 175 945 320
1PQ8 35 . 4, 6, 8 1) 2065 100 M24 210 180 28 106
400 1PQ8 40 . 2 400 35 440 400 175 1025 320 33 40 2148 550 1945 80 M20 170 140 22 85
4, 6, 8 2188 1985 110 M24 210 180 28 116
450 1PQ8 45 . 2 2) 450 42 525 400 175 1110 320 39 47 2308 550 2105 90 M24 170 140 25 95
4, 6, 8 2348 2145 120 210 180 32 127

1)
With bearings for increased cantilever forces.
2)
Only at 50 Hz.

Siemens D 81.1 2007 3/61


Siemens AG 2007

IEC Squirrel-Cage Motors


Non-standard motors frame size 315 and above
Dimensions

Dimensional drawings
Cast-iron series 1LL8, frame sizes 315 to 450
Type of construction IM B3

LC
L AD
LL
HK
3

DA

FA
EB

HD
EC
F

AC
D

BE
BC

HB
GA GC AG

HA
H
DB DC
G_D081_XX_00047
BA K K' AA
E C B CA EA A
BB AB

Connection box position


Basic version Special versions
G_D081_EN_00050

G_D081_EN_00051
G_D081_EN_00049

Cable entry: bottom Cable entry: top Cable entry: top


Console: 0 degrees Console: 180 degrees Console: 0 degrees
Order code: Order code: K85 Order code: plain text

For motor Dimension designation acc. to IEC


Frame Type Number of A AA AB AC 1) AD AD' AG AG' AQ B BA BB BC BE C CA
size poles
315 1LL8 31 . 2 560 120 680 710 655 565 670 630 180 780 195 110 180 435
4, 6, 8 660 560
355 1LL8 35 . 2 630 150 780 790 840 740 750 800 220 980 185 135 200 470
4, 6, 8 880 745
400 1LL8 40 . 2 710 150 860 880 865 775 850 900 220 1080 186 100 224 506
4, 6, 8 930 795
450 1LL8 45 . 2 2) 800 180 980 970 900 810 950 1000 260 1220 170 100 250 540
4, 6, 8 980 845

1) Measured across the bolt heads.


2) Only at 50 Hz.

3/62 Siemens D 81.1 2007


Siemens AG 2007

IEC Squirrel-Cage Motors


Non-standard motors frame size 315 and above
Dimensions

Dimensional drawings
Cast-iron series 1LL8, frame sizes 315 to 450
Type of construction IM V1
For flange dimensions, see Page 3/64 (Z = the number of retaining holes)
L
HH
LL
3

H
C
K
H

H
B'
LM

E
F

BE

AC

AQ
D

GA EB

'
AD
'
AG
DB

G_D081_XX_00048

Connection box position


Special versions
G_D081_EN_00052

G_D081_EN_00053

Cable entry: DE / NDE Cable entry: DE / NDE


Console: 0 degrees Console: 180 degrees
Order code: K83/K84 Order code: plain text
For motor Dimension designation acc. to IEC DE shaft extension
Frame Type Number H HA HB HB' HD HK K K' L LC LL LM D DB E EB F GA
size of poles
315 1LL8 31 . 2 315 28 360 825 250 26 33 1380 1495 330 1530 70 M20 140 125 20 74.5
4, 6, 8 290 1410 1555 90 M24 170 140 25 95
355 1LL8 35 . 2 355 35 360 945 320 33 40 1605 1750 550 1765 80 M20 170 140 22 85
4, 6, 8 400 1635 1820 110 M24 210 180 28 116
400 1LL8 40 . 2 400 35 440 1020 320 33 40 1793 1940 550 1975 85 M20 170 140 22 90
4, 6, 8 400 1833 2010 120 M24 210 180 32 127
450 1LL8 45 . 2 1) 450 42 525 1110 320 39 47 1953 2100 550 2145 90 M24 170 140 25 95
4, 6, 8 400 1993 2250 130 M24 250 220 32 137

1) Only at 50 Hz.

Siemens D 81.1 2007 3/63


Siemens AG 2007

IEC Squirrel-Cage Motors


Non-standard motors frame size 315 and above
Dimensions

Dimensional drawings
Flange dimensions

3
G_D081_XX_00026

Frame size Type of construction Flange type Flange with Dimension designation acc. to IEC
through holes (FF/A)
According to Acc. to
DIN EN 50347 DIN 42948 LA LE M N P S T Z
315
2-pole IM B35, IM V1 Flange 25 140 740 680 800 22 6 8
4-pole to 8-pole 170
355
2-pole IM B35, IM V1 Flange 25 140 840 780 900 22 6 8
4-pole to 8-pole 170
400
2-pole IM B35, IM V1 Flange 28 170 940 880 1000 22 6 8
4-pole to 8-pole 210
450
2-pole IM B35, IM V1 Flange 30 170 1080 1000 1150 26 6 8
4-pole to 8-pole 210

3/64 Siemens D 81.1 2007