InstruCalc Ver 5.

1
CV CALCULATION FOR MOV-201-2C-1
21/07/2017
Project CTR 127. ORF Gas line to LPG Plant Assessment
Control Valve - Gas, Steam or Vapor flow
Tag number MOV-201-2C-2 By RPT
App AD
Common input data
Valve
Data : 4 in Globe : Equal% Contour. Ports : One. Flow to : Open
Rated Cv : 176. Rated FL : .9. Rated xT : .68
Pipe sizes
Inlet : 4 in Outlet : 4 in Outlet pipe wall : .337 in
Base conditions
Base pressure : 14.7psia Base temperature : 59degF
Barometric pressure : 14.73psia
Fluid data
Name : Gas Gas property factor: 0 dbA
Variable input data
Case 1 Case 2 Case 3 Units
Gas flow 15.27 10.689 Msft3/d
Percent of system flow 80 70 10
Flow temperature 90 90 degF
Inlet pressure 350 350 psig
Valve pressure drop 10 10 psi
Molecular weight 19.91 19.91
Density @ FTP 1.343 1.343 lb/ft3
Cp/Cv Sp heat ratio 1.348 1.348
FL @ % flow .9 .93 .97
Acoustic efficiency .0000013754 .0000013754
Calculated Cv 146.26 102.38
Output data
Percent of valve Cv 83 58
Noise level 63 62 dbA
Sonic minimum size 1.0108 .84569 in
Status Normal Normal

Selection based on Model 10000

Notes
THIS CALCULATION TO BE VERIFIED DURING DETAIL ENGIENERING