Академический Документы
Профессиональный Документы
Культура Документы
TAREA
TRANSFERENCIA DE CALOR
DATOS:
rcritico=
h
Kaisl=0.17 w/mC
hb=3 w/mC rcritico= rcritico-r0
Ta=200C 2( ) 2( )
Q/L = =
T=20C + 1 + ln (1 )
0 1
r0=2.5cm + h 0
Espesor r1 Q/L
del radio del Perdidas
aislante aislante de calor
cm cm w/m
0 0 0 84.8230016
(0.1)rcritico 0.31 2.81 90.1173521
(0.3) rcritico 0.93 3.43 97.678054
(0.5) rcritico 1.55 4.05 102.181735
(0.7) rcritico 2.17 4.67 104.589455
(0.9) rcritico 2.79 5.29 105.597953
rcritico 3.1 5.6 105.734447
(1.2) rcritico 3.72 6.22 105.494367
(1.5) rcritico 4.65 7.15 104.301503
(1.7) rcritico 5.27 7.77 103.18656
(1.9) rcritico 5.89 8.39 101.935029
(2) rcritico 6.2 8.7 101.279064
(5)rcritico 15.5 18 83.9992222
(7) rcritico 21.7 24.2 76.7765377
(10) rcritico 31 33.5 69.5502999
(20) rcritico 62 64.5 57.5950377
(50) rcritico 155 157.5 46.0062804
Maira Dolores Ramrez Mendiola 13-noviembre-2017
Transferencia de Calor
100
90
80
Q/L
70
60
50
40
0 20 40 60 80 100 120 140 160
r
100
90
80
Q/L
70
60
50
40
0 20 40 60 80 100 120 140 160
r
Maira Dolores Ramrez Mendiola 13-noviembre-2017
Transferencia de Calor
ANLISIS Y DISCUSION DE
CALOR PERDIDO VS ESPESOR DEL AISLANTE
LAS GRFICAS 110
rCRITICO
Al analizar las graficas de calor
105
perdido contra el espesor y radio
del aislante, se puede observar 100
inicialmente que al aumentar el
Q/L
95
espesor del aislante tambin
aumenta la transferencia o 90
perdida de calor por unidad de
longitud, Por lo tanto, aislar un 85
tubo puede aumentar la razn de
80
la transferencia de calor del 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5
tubo en lugar de disminuirla, r
hasta que se llega a un valor
Acercamiento al punto del radio critico en ambas
mximo el cual por sus
graficas
particularidad llamamos radio CALOR PERDIDO VS RADIO DEL AISLANTE
crtico donde la resistencia al flujo
110
de calor es la minima del sistema, rCRITICO
si continuamos aumentando el 105