Академический Документы
Профессиональный Документы
Культура Документы
Issue V3.0
Date 2010-05-30
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Contents
1 Introduction....................................................................................................................................5
1.1 Product Positioning .......................................................................................................................................... 5
1.2 Product Features............................................................................................................................................... 6
2 System Architecture......................................................................................................................8
2.1 Product Overview............................................................................................................................................. 8
2.2 BBU3900 ......................................................................................................................................................... 8
2.2.1 Appearance of the BBU3900 .................................................................................................................. 8
2.2.2 Hardware Units of the BBU3900............................................................................................................ 9
2.2.3 Ports on the BBU3900 .......................................................................................................................... 10
2.3 RRU ............................................................................................................................................................... 11
2.3.1 Specifications of the RRU..................................................................................................................... 11
2.3.2 Appearance of the RRU ........................................................................................................................ 11
2.3.3 Ports on the RRU .................................................................................................................................. 12
2.4 WRFU ............................................................................................................................................................ 14
2.4.1 Specifications of the WRFU ................................................................................................................. 14
2.4.2 Appearance of the WRFU ..................................................................................................................... 14
2.4.3 Ports on the WRFU ............................................................................................................................... 15
2.5 Auxiliary Devices........................................................................................................................................... 15
2.5.1 APM30H ............................................................................................................................................... 16
2.5.2 TMC11H ............................................................................................................................................... 16
2.5.3 Outdoor RF Cabinet.............................................................................................................................. 17
2.5.4 IBBS200D............................................................................................................................................. 18
2.5.5 Indoor Macro Cabinet ........................................................................................................................... 19
2.5.6 Indoor BTS3900L Cabinet.................................................................................................................... 19
2.5.7 PS4890 .................................................................................................................................................. 20
2.5.8 OMB ..................................................................................................................................................... 21
2.5.9 SLPU..................................................................................................................................................... 22
1 Introduction
2 System Architecture
2.2 BBU3900
2.2.1 Appearance of the BBU3900
The BBU3900 features a compact case structure that requires a 19-inch-wide and 2 U-high
space. It can be installed on a wall, on a staircase, in a storeroom, or in an outdoor cabinet in
the existing network. Figure 2-1 shows the BBU3900.
N x M = sector x carrier. For example, 3 x 1 indicates that each of the three sectors has one carrier.
USCU GPS antenna port 1 SMA connector Port for RF signal input from the satellite
card
RGPS port 2 PCB welded wiring Connecting to the RGPS signal cable
terminal
TOD port 2 RJ-45 connector Connecting to the TOD equipment
M-1PPS port 1 SMA connector Connecting to the Metro 1000 equipment
BITS port 1 SMA connector Connecting to the BITS clock
UTRP E1/T1 port 2 DB26 connector Providing eight ATM over E1s/T1s or eight
IP over E1s/T1s
Unchannelized 1 SFP connector Providing one unchannelized STM-1/OC-3
STM-1/OC-3 port port
The UEIU is a monitoring and dry contact extension board for the UPEU.
2.3 RRU
The RRU is the outdoor remote radio unit. The RRU is the RF module of the distributed
NodeB and is installed close to the antenna.
RRU3804 60 W 4
RRU3801E 40 W 2
RRU3801C 40 W 2
RRU3808 2 x 40 W 4
RRU3806 80 W 4
2.4 WRFU
The WCDMA Radio Filter Unit (WRFU) is an indoor RF unit and is the RF module of the
macro NodeB.
power cabinet PS4890, indoor BTS3900L cabinet, Outdoor Mini Cabinet (OMB), and Signal
Lightning Protection Unit (SLPU).
2.5.1 APM30H
The advanced power module APM30H is an outdoor power backup system. The APM30H
provides 48 V DC power and backup power for distributed NodeBs, outdoor macro NodeBs,
and mini NodeBs. In addition, it provides installation space for the BBU3900 and customer
equipment.
The APM30H features a compact and lightweight design. It can be installed on a pole or on
the ground. Figure 2-4 shows the structure of the APM30H.
2.5.2 TMC11H
The TMC11H provides installation space for the BBU3900 and transmission equipment, thus
meeting the requirements of quick network construction. The TMC11H is applied to outdoor
scenarios with adverse environment. It features compact design and easy transport. Figure 2-5
shows the structure of the TMC11H.
(1) Fan (internal recycling) (2) CMUA (Central Monitoring Unit type A)
(3) PDU-03 (4) Door status sensor
(5) ELU (6) Fan (external recycling)
(7) Heat exchanger core (8) AC power distribution box
2.5.4 IBBS200D
The IBBS200D is a battery cabinet applied to outdoor scenarios. It features compact design
and easy transport. The IBBS200D can be configured with batteries of different capacity as
required, such as 48 V 50 Ah, 48 V 100 Ah, 48 V 92 Ah, and 48 V 184 Ah. Figure 2-7 shows
the IBBS200D.
2.5.7 PS4890
The PS4890, an indoor power cabinet, provides DC power and power backup for the
distributed NodeBs or BTS3900s. The PS4890 also provides installation space for the
BBU3900 and transmission equipment.
The PS4890 features compact design and light weight. It can be installed on a pole or on the
ground. In addition, the PS4890 houses the batteries. Figure 2-10 shows the structure of the
PS4890.
2.5.8 OMB
The OMB provides functions such as power distribution and surge protection for the
BBU3900. When the BBU3900 is installed in an outdoor mini cabinet, it works as a
component of the compact mini NodeB in outdoor application.
The OMB has a built-in heat exchanger. If the AC power is used, the cabinet must be
configured with an EPS30-4815A and an SPD (AC); if the DC power is used, the cabinet
must be configured with a DC power distribution box. Figure 2-11 shows the internal
structure of the outdoor mini NodeB in different power configurations.
2.5.9 SLPU
The SLPU provides the signal surge protection for the NodeB. Figure 2-12 shows the SLPU.
UELP INSIDE port 1 DB25 connector Port for four E1/T1 signal inputs
OUTSIDE port 1 DB26 connector Port for four E1/T1 signal outputs
UFLP FE0 and FE1 2 RJ-45 connector Connecting to the FE0 port on WMPT
(INSIDE) ports
FE0 and FE1 2 RJ-45 connector Connecting to the external device
(OUTSIDE) ports
USLP2 OUT0 and OUT1 2 RJ-45 connector Connecting to the surge protection transfer
ports cable from the main control board
IN0, IN1, IN2, 4 4-pin connector Connecting to the external device
and IN3 ports
3 Application Scenarios
3.1 Overview
Huawei 3900 series NodeB products can be configured in different ways. Therefore, these
products can be deployed in different application scenarios, thus providing a perfect
whole-network solution for operators. The Huawei 3900 series NodeBs consist of the indoor
macro NodeB (BTS3900 and BTS3900L), outdoor macro NodeB (BTS3900A), distributed
NodeB (DBS3900), and mini NodeB (BTS3900C).
The application scenarios are as follows:
z The BTS3900 and BTS3900L are mainly applicable to indoor installation scenarios
where traffic is heavy, equipment room rental is high, and space is limited.
z The BTS3900A is mainly applicable to outdoor scenarios where large-capacity coverage
is required in urban, suburban, and rural areas.
z The DBS3900 is mainly applicable to outdoor application scenarios where wide
coverage is required and site construction is difficult.
z The BTS3900C is mainly applicable to outdoor coverage and hot-spot coverage.
4 Technical Specifications
Item Specification
40 W WRFU The WRFU supports two carriers, and its output power at the antenna
port reaches 40 W.
Item Specification
MHz) 126.5** 129.3** 132.0**
Band V/VI 125.6* 128.4* 131.1*
(850 MHz)***
126.3** 129.1** 131.8**
z *: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
z **: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
z ***: Measurement value of the sub-band at 850 MHz.
Transmission port Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock, OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Dimensions z BTS3900 without the base: 900 mm x 600 mm x 450 mm
(height x width x z Base: 40 mm x 600 mm x 420 mm
depth)
Weight z Empty cabinet: 70 kg
z BTS3900 in 3 x 1 configuration: 120 kg
z BTS3900 in full configuration: 160 kg
Input power z 48 V DC, permissible voltage range: 38.4 V DC to 57 V DC
z +24 V DC, permissible voltage range: +21.6 V DC to +29 V DC
z 220 V AC single-phase, rated voltage range: 220 V AC to 240 V AC; permissible voltage
range: 176 V AC to 290 V AC
z 220 V AC three-phase, rated voltage range: 220/346 V AC to 240/415 V AC; permissible
voltage range: 176/304 V AC to 290/500 V AC
z 110 V AC dual-live-wire power cable:
Rated voltage: 100/200 V AC to 120/240 V AC; permissible voltage range: 90/180 V
AC to 135/270 V AC
Rated voltage: 120/208 V AC to 127/220 V AC; permissible voltage range: 105/176 V
AC to 150/260 V AC
Power Power consumption (W) Power backup duration based on
consumption new batteries and typical power
consumption (hour)
Configuration Typical power Maximum power 50 Ah 92 Ah 184Ah
consumption consumption
3x1 500 590 4.2 8.7 17.8
3x2 590 800 3.5 7.1 14.9
3x3 800 1020 2.4 4.9 11.0
Item Specification
z The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900 works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier
is 20 W and the BTS3900 works with a 100% load at 25C ambient temperature.
Item Specification
40 W WRFU The WRFU supports two carriers, and its output power at the antenna
port reaches 40 W.
z *: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
z **: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
z ***: Measurement value of the sub-band at 850 MHz.
Item Specification
Transmission port Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock, OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Dimensions z BTS3900L without the base: 1600 mm x 600 mm x 450 mm
(height x width x z Base: 40 mm x 600 mm x 420 mm
depth)
Weight z Empty cabinet: 75 kg
z Cabinet in 3 x 1 configuration: 140 kg
z Cabinet in full configuration: 235 kg
Input power 48 V DC, permissible voltage range: 38.4 V DC to 57 V DC
Power Configuration Typical power consumption (W) Maximum power consumption (W)
consumption
3x1 517 607
3x2 607 817
3x3 817 1037
3x4 987 1267
z The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900L works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier
is 20 W and the BTS3900L works with a 100% load at 25C ambient temperature.
Item Specification
EMC The BTS3900 meets the Electromagnetic compatibility (EMC) requirements and complies
with the following standards:
z CISPR 22 (1997)
z EN 55022 (1998)
z EN 301 489-23 V1.2.1 (2002-11)
z CISPR 24 (1998)
z IEC 61000-4-2
z IEC 61000-4-3
z IEC 61000-4-4
z IEC 61000-4-5
z IEC 61000-4-6
z IEC 61000-4-29
z ETSI 301 489-1 V1.3.1 (2001-09)
z FCC Part 15
The BTS3900L is CE certified.
Item Specification
Item Specification
80 W WRFU The WRFU supports four carriers, and its output power at the antenna
port reaches 80 W.
z The carrier a maximum of 60 W in case of 1-carrier configuration.
z Each carrier supports a maximum of 40 W in case of 2-carrier
configuration. *
z Each carrier a maximum of 20 W in case of 3-carrier or 4-carrier
configuration.
z Uneven power configuration is supported.
40 W WRFU The WRFU supports two carriers, and its output power at the antenna
port reaches 40 W.
z *: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
z **: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
z ***: Measurement value of the sub-band at 850 MHz.
Transmission port Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock, OCXO free-run clock, IP clock, and
synchronization BITS clock
Accuracy: 0.05 ppm
Dimensions RF cabinet/APM30H/TMC/BBC:
(height x width x z Without the base: 700 mm x 600 mm x 480 mm
depth)
z Base: 200 mm x 600 mm x 480 mm
Item Specification
Weight z RF cabinet: 55 kg
z APM30H cabinet: 65 kg
z BTS3900A in typical 3 x 1 configuration: 165 kg (without batteries)
z BTS3900A in full configuration: 210 kg (RF cabinet with 6 RFUs and without
batteries)
Input power z 48 V DC, permissible voltage range: 38.4 V DC to 57 V DC
z 220 V AC single-phase: rated voltage: 220 V AC to 240 V AC; permissible voltage
range: 176 V AC to 290 V AC
z 220V AC three-phase: rated voltage: 220/346 V AC to 240/415 V AC; permissible
voltage range: 176/304 V AC to 290/500 V AC
z 110 V AC dual-live-wire power cable:
Rated voltage: 100/200 V AC to 120/240 V AC; permissible voltage range: 90/180 V
AC to 135/270 V AC
Rated voltage: 120/208 V AC to 127/220 V AC; permissible voltage range: 105/176
V AC to 150/260 V AC
Power Power consumption (W) Power backup duration based on the
consumption battery capacity and typical power
consumption (hour)
Configuration Typical Maximum 50 Ah 92 Ah 184 Ah
power power
consumption consumption
3x1 570 670 4.0 8.4 17.1
3x2 680 910 3.3 6.9 14.4
3x3 910 1150 2.3 4.8 10.7
3x4 1110 1410 1.7 3.8 8.7
z The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900A works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier
is 20 W and the BTS3900A works with a 100% load at 25C ambient temperature.
Battery 50 Ah or 92 Ah
Temperature 40C to +50C (with solar radiation, APM30H configured)
Relative humidity 5% RH to 100% RH
Absolute 130 g/m3
humidity
Air pressure 70 kPa to 106 kPa
IP rating IP55
Storage ETSI EN300019-1-1 V2.1.4 (2003-04) class1.2 "Weather protected, not
temperature-controlled storage locations"
Item Specification
Item Specification
Item Specification
Output power A single RRU3804 supports up to four carriers with a 60 W output power at the antenna
port with four carriers.
z One-carrier configuration: maximum output power of 60 W per carrier
z Two-carrier configuration: maximum output power of 30 W per carrier
z Three-carrier configuration: maximum output power of 20 W per carrier
z Four-carrier configuration: maximum output power of 15 W per carrier
z Supporting differentiated power configured for different carriers
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output
power is measured at the antenna port of the RF module.
z *: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the
antenna port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is
within 0.001.
z **: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that
the AMR service at 12.2 kbit/s is used and the BER is within 0.001.
z ***: Measurement value of the sub-band at 850 MHz.
Transmission port Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Dimensions z BBU3900: 86 mm x 442 mm x 310 mm
(height x width x z DC RRU3804
depth)
480 mm x 270 mm x 140 mm (without housing and connectors)
485 mm x 285 mm x 170 mm (with housing)
z AC RRU3804
480 mm x 270 mm x 220 mm (without housing and connectors)
485 mm x 285 mm x 250 mm (with housing)
Item Specification
Weight z BBU3900
In full configuration: 11 kg
In typical configuration (1 PSU, 1 WBBP, 1 WMPT): 7 kg
z DC RRU3804
Without housing: 15 kg
With housing: 17 kg
z AC RRU3804
Without housing: 20.5 kg
With housing: 22.5 kg
Input voltage z BBU3900:
+24V DC, voltage range: +21.6 V DC to +29 V DC
-48V DC, voltage range: 38.4 V DC to 57 V DC
z RRU3804
48 V DC, voltage range: 36 V DC to 57 V DC
200 V AC to 240 V AC single phase, voltage range: 176 V AC to 290 V AC
100/200 V AC to 120/240 V AC two phases, voltage range: 90/180 V AC to 135/270
V AC
Power Power consumption (W) Power backup duration based on
consumption the battery capacity and typical
power consumption (hour)
Configuration Typical power Maximum 24 Ah 50 Ah 92 Ah
consumption power
(50% load) consumption
(100% load)
3x1 400 500 2.3 5.5 11.0
3x2 550 710 1.5 3.7 7.8
3x3 710 950 1.0 2.8 5.7
3x4 740 990 1.0 2.8 5.7
NOTE
z The typical power consumption is reached when the output power at the antenna port per carrier is
20 W and the DBS3900 works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier
is 20 W and the DBS3900 works with a 100% load at 25C ambient temperature.
z In 3 x4 configurations, the typical and maximum power consumption are reached when the output
power per carrier at the antenna port is 15 W
Item Specification
Item Specification
Item Specification
Output power One RRU3801E supports two carriers with 40 W output power at the antenna port of the RF
module.
z One-carrier configuration: 40 W per carrier
z Two-carrier configuration: 20 W per carrier
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output power
is measured at the antenna port of the RF module.
z *: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
z **: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE optical
port
Clock Clock on the Iub interface, GPS clock, OCXO free-run clock, IP clock, BITS clock
synchronization Accuracy: 0.05 ppm
Dimensions z BBU3900: 86 mm x 442 mm x 310 mm
(height x width z DC RRU3801E:
x depth)
480 mm x 270 mm x 140 mm (without housing and connectors)
485 mm x 285 mm x 170 mm (with housing)
z AC RRU3801E:
480 mm x 270 mm x 220 mm (without housing and connectors)
485 mm x 285 mm x 250 mm (with housing)
Weight z BBU3900
In full configuration: 11 kg
In typical configuration (1 PSU, 1 WBBP, and 1 WMPT): 7 kg
z DC RRU3801E
Without housing: 15 kg
With housing: 17 kg
z AC RRU3801E
Without housing: 20.5 kg
With housing: 22.5 kg
Item Specification
z The typical power consumption is reached when the output power at the antenna port per carrier is 20 W
and the DBS3900 works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the DBS3900 works with a 100% load at 25C ambient temperature.
Item Specification
EMC The DBS3900 meets the EMC requirements and complies with the following standards:
z CISPR 22 (1997)
z EN 55022 (1998)
z EN 301 489-23 V1.2.1 (2002-11)
z CISPR 24 (1998)
z IEC 61000-4-2
z IEC 61000-4-3
z IEC 61000-4-4
z IEC 61000-4-5
z IEC 61000-4-6
z IEC 61000-4-29
z ETSI 301 489-1 V1.3.1 (2001-09)
z FCC Part 15
The DBS3900 is CE certified.
Item Specification
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output power
is measured at the antenna port of the RF module.
Item Specification
z *: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
z **: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock on the Iub interface, GPS clock, OCXO free-run clock, IP clock, and BITS clock
synchronization Accuracy: 0.05 ppm
Dimensions z BBU3900: 86 mm x 442 mm x 310 mm
(height x width z RRU3801C
x depth)
480 mm x 365 mm x 145 mm (without rack and housing)
610 mm x 380 mm x 200 mm (with rack and housing)
Weight z BBU3900
In full configuration: 11 kg
In typical configuration (1 PSU, 1 WBBP, and 1 WMPT): 7 kg
z RRU3801C
Without housing: 20 kg
With housing: 22 kg
Input power z BBU3900
+24 V DC, voltage range: +21.6 V DC to +29 V DC
48 V DC, voltage range: 38.4 V DC to 57 V DC
z RRU3801C
48 V DC, voltage range: 40 V DC to 60 V DC
200 V AC to 240 V AC single phase, voltage range: 150 V AC to 300 V AC
Power Power consumption (W) Power backup duration based on the
consumption battery capacity and typical power
consumption (hour)
Configuration Typical power Maximum 24 Ah 50 Ah 92 Ah
consumption power
(50% load) consumption
(100% load)
Item Specification
z The typical power consumption is reached when the output power at the antenna port per carrier is 20 W
and the DBS3900 works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the DBS3900 works with a 100% load at 25C ambient temperature.
Item Specification
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output power
is measured at the antenna port of the RF module.
z *: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
z **: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock on the Iub interface, GPS clock, OCXO free-run clock, IP clock, and BITS clock
synchronization Accuracy: 0.05 ppm
Dimensions z BBU3900: 86 mm x 442 mm x 310 mm
(height x width z RRU3808
x depth)
480 mm x 270 mm x 140 mm (without connectors and housing)
485 mm x 285 mm x 170 mm (with connectors)
Item Specification
Weight z BBU3900
In full configuration: 11 kg
In typical configuration (1 PSU, 1 WBBP, and 1 WMPT): 7 kg
z RRU3808
Without housing: 17 kg
With housing: 19 kg
Input power z BBU3900
+24 V DC, voltage range: +21.6 V DC to +29 V DC
48 V DC, voltage range: 38.4 V DC to 57 V DC
z RRU3808
48 V DC, voltage range: 36 V DC to 57 V DC
Power Band I (2100MHz) RRU3808
consumption
Power consumption in MIMO configuration (W) Power backup duration based on the
battery capacity and typical power
consumption (hour)
Configuration Typical Maximum 50 Ah 92 Ah
power power
consumption consumption
(50% load) (100% load)
z The typical power consumption is reached when the output power at the antenna port per carrier is 10 W
+ 10 W and the DBS3900 works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier is
10 W + 10 W and the DBS3900 works with a 100% load at 25C ambient temperature.
Item Specification
z The typical power consumption is reached when the output power at the antenna port per carrier is 20 W
and the DBS3900 works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the DBS3900 works with a 100% load at 25C ambient temperature.
z The typical power consumption is reached when the output power at the antenna port per carrier is 10 W
+ 10 W and the DBS3900 works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier is
10 W + 10 W and the DBS3900 works with a 100% load at 25C ambient temperature.
z The typical power consumption is reached when the output power at the antenna port per carrier is 20 W
and the DBS3900 works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the DBS3900 works with a 100% load at 25C ambient temperature.
Item Specification
Item Specification
Maximum output power = Maximum output power of the PA - Internal losses. The maximum
output power is measured at the antenna port of the RF module.
Receiver sensitivity Frequency band 1-way receiver 2-way receiver 4-way receiver
sensitivity (dBm) sensitivity (dBm) sensitivity (dBm)
Band I (2100 MHz) 125.8* 128.6* 131.3*
126.5** 129.3** 132.0**
z The receiver sensitivity is measured, as recommended in 3GPP TS 25.104, over the full band at
the antenna connector provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate
(BER) does not exceed 0.001.
z The receiver sensitivity is measured on the center frequency at the antenna connector provided
that 12.2 kbit/s Adaptive Multi Rate (AMR) service is in progress and the BER does not exceed
0.001.
Transmission port Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
Optional hardware units provide unchannelized STM-1 port, GE electrical port, and
GE optical port
Clock synchronization Line clock extracted from the Iub interface, GPS clock, BITS clock, clock of the
OCXO in free-run mode, and IP clock
Precision:0.05 ppm
Dimensions (height x BBU3900:86 mm x 442 mm x 310 mm
width x depth) RRU3806:
z 480 mm x 270 mm x 140 mm (without housing and connectors)
z 485 mm x 285 mm x 170 mm (with housing)
Weight z BBU3900
In full configuration: 11 kg
In typical configuration (1 PSU, 1 WBBP, and 1 WMPT): 7 kg
z RRU3806
Without housing: 15 kg
With housing: 17 kg
Input power z BBU3900:
+24 V DC, voltage range: +21.6 V DC to +29 V DC
48 V DC, voltage range: 38.4 V DC to 57 V DC
z RRU3806:48 V DC, voltage range: 36 V DC to 57 V DC
Power consumption Power consumption (W) Power backup duration based
on new batteries and typical
power consumption (hour)
Configuration Typical power Maximum 50 Ah 92 Ah
consumption power
(with a 50% consumption
load) (with a 100%
load)
31 416 470 5.1 10.6
32 521 644 3.9 8.3
33 681 855 2.9 5.9
34 780 1050 2.4 5.0
z The typical power consumption is reached when the output power at the antenna port per
carrier is 20 W and the equipment works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power each carrier at the
antenna port is 20 W, the equipment works with 100% load, and the ambient temperature is
25C.
Item Specification
Item Specification
z Maximum output power = Maximum output power of the PA - Internal loss. The maximum output
power is measured at the antenna port of the RF module.
z * refers to the maximum output power in typical configurations.
z *: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
z **: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
z ***: Measurement value of the sub-band at 850 MHz.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Dimensions z BTS3900C: 600 mm x 400 mm x 390 mm
(height x width x z OMB: 600 mm x 240 mm x 390 mm
depth)
Weight z AC BTS3900C: 50 kg
z DC BTS3900C: 48 kg
Item Specification
z The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900C works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the BTS3900C works with a 100% load at 25C ambient temperature.
Item Specification
EMC The BTS3900C meets the EMC requirements and complies with the following standards:
z CISPR 22 (1997)
z EN 55022 (1998)
z EN 301 489-23 V1.2.1 (2002-11)
z CISPR 24 (1998)
z IEC 61000-4-2
z IEC 61000-4-3
z IEC 61000-4-4
z IEC 61000-4-5
z IEC 61000-4-6
z IEC 61000-4-29
z ETSI 301 489-1 V1.3.1 (2001-09)
z FCC Part 15
The BTS3900C is CE certified.
Item Specification
z Maximum output power = Maximum output power of the PA - Internal loss. The maximum output
power is measured at the antenna port of the RF module.
z * refers to the maximum output power in typical configurations.
Item Specification
z *: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
z **: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
z ***: Measurement value of the sub-band at 850 MHz.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Dimensions z BTS3900C: 600 mm x 400 mm x 390 mm
(height x width x z OMB: 600 mm x 240 mm x 390 mm
depth)
Weight z AC BTS3900C: 50 kg
z DC BTS3900C: 48 kg
Input voltage z 48 V DC, voltage range: 38.4 V DC to 57 V DC
z 200 V AC to 240 V AC single phase, voltage range: 176 V AC to 290 V AC
z 100/200 V AC to 120/240 V AC dual-live-wire power cable; voltage range: 90/180 V AC
to 135/270 V AC
Power Configuration Typical power consumption Maximum power
consumption consumption
z The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900C works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the BTS3900C works with a 100% load at 25C ambient temperature.
Item Specification
Item Specification
Item Specification
Output power The RRU3801C supports two carriers with a 40 W output power at the antenna port.
z One-carrier configuration: maximum output power of 40 W per carrier
z Two-carrier configuration: maximum output power of 20 W per carrier
Maximum output power = Maximum output power of the PA - Internal loss. The maximum output power
is measured at the antenna port of the RF module.
z *: As recommended in 3GPP TS25.104, the receiver sensitivity (full band) is measured at the antenna
port provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) is within 0.001.
z **: The receiver sensitivity (at the centre frequency) is measured at the antenna port provided that the
AMR service at 12.2 kbit/s is used and the BER is within 0.001.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Clock extracted from the Iub interface, GPS clock , OCXO free-run clock, IP clock, BITS
synchronization clock
Accuracy: 0.05 ppm
Dimensions z BTS3900C: 600 mm x 400 mm x 390 mm
(height x width x z OMB: 600 mm x 240 mm x 390 mm
depth)
Weight z AC BTS3900C: 55 kg
z DC BTS3900C: 53 kg
Input voltage z 48 V DC, voltage range: 38.4 V DC to 57 V DC
z 200 V AC to 240 V AC single phase, voltage range: 176 V AC to 290 V AC
z 100/200 V AC to 120/240 V AC dual-live-wire power cable; voltage range: 90/180 V AC
to 135/270 V AC
Power Configuration Typical power Maximum power consumption
consumption consumption
1x1 280 W 300 W
1x2 320 W 370 W
Item Specification
z The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the BTS3900C works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power at the antenna port per carrier is
20 W and the BTS3900C works with a 100% load at 25C ambient temperature.
Item Specification
Item Specification
Capacity 3 cells
Maximum configuration:1 x 3
Uplink: 384 CEs
Downlink:384 CEs
Output power The RRU3806 supports four carriers, and its output power at the antenna connector reaches
80 W.
z The carrier a maximum of 80 W in case of 1-carrier configuration.
z Each carrier a maximum of 40 W in case of 2-carrier configuration.
z Each carrier a maximum of 26 W in case of 3-carrier configuration.
z Each carrier a maximum of 20 W in case of 4-carrier configuration.
z Uneven power configuration is supported.
Maximum output power = Maximum output power of the PA - Internal losses. The maximum output
power is measured at the antenna port of the RF module.
z The receiver sensitivity is measured, as recommended in 3GPP TS 25.104, over the full band at the
antenna connector provided that the channel rate reaches 12.2 kbit/s and the Bit Error Rate (BER) does
not exceed 0.001.
z The receiver sensitivity is measured on the center frequency at the antenna connector provided that
12.2 kbit/s Adaptive Multi Rate (AMR) service is in progress and the BER does not exceed 0.001.
Transmission Mandatory hardware units provide E1/T1 port, FE electrical port, and FE optical port
port Optional hardware units provide unchannelized STM-1 port, GE electrical port, and GE
optical port
Clock Line clock extracted from the Iub interface, GPS clock, BITS clock, clock of the OCXO in
synchronization free-run mode, and IP clock
Precision:0.05 ppm
Dimensions 600 mm x 400 mm x 390 mm
(height x width x OMB: 600 mm x 240 mm x 390 mm
depth)
Weight z AC BTS3900C: 50 kg
z DC BTS3900C: 48 kg
Input voltage 48 V DC, voltage range: 38.4 V DC to 57 V DC
200 V AC to 240 V AC single-phase power cable, voltage range: 176 V AC to 290 V AC
100/200 V AC to 120/240 V AC dual live line power cable, voltage range: 90/180 V AC to
135/270 V AC
Power Configuration Typical power consumption Maximum power consumption
Item Specification
consumption 1x1 222 W 250 W
1x2 257 W 308 W
1x3 297 W 365 W
z The typical power consumption is reached when the output power at the antenna port per carrier is 20
W and the equipment works with a 50% load at 25C ambient temperature.
z The maximum power consumption is reached when the output power each carrier at the antenna port
is 20 W, the equipment works with 100% load, and the ambient temperature is 25C.