This document provides specifications for a single phase relay tester that can perform primary injection and testing. It has the following key capabilities:
1. It can output high power AC current up to 1000A and high power AC/DC voltages up to 250V.
2. It has precision AC/DC current and voltage outputs for testing along with integrated measurement functions.
3. It includes binary inputs and outputs to automate testing along with a power supply.
This document provides specifications for a single phase relay tester that can perform primary injection and testing. It has the following key capabilities:
1. It can output high power AC current up to 1000A and high power AC/DC voltages up to 250V.
2. It has precision AC/DC current and voltage outputs for testing along with integrated measurement functions.
3. It includes binary inputs and outputs to automate testing along with a power supply.
This document provides specifications for a single phase relay tester that can perform primary injection and testing. It has the following key capabilities:
1. It can output high power AC current up to 1000A and high power AC/DC voltages up to 250V.
2. It has precision AC/DC current and voltage outputs for testing along with integrated measurement functions.
3. It includes binary inputs and outputs to automate testing along with a power supply.
Universal Tester Primar y Injection and Test Equipment Specifications Features High power AC current output (I1) Range 2 minutes continuous output at1 000A 0.2A~20A 10~250A Accuracy 0.5% Manual and Ramp control Output voltage 130V~100V 10V~8V High precision AC/DC current output (I3) CT test functions available Power 2000VA(20A) 2000VA(250A) Load time AC output DC output Independent Aux DC supply Mode Output 250A 50A <50A In-built multi-meter funtion Range 0~200mA 0~200mA Time 120s 3000s continuous Accuracy 0.5% 0.5% Weight : 37kg Power(200mA) 3VA 3W High power AC voltage output (U1) Frequency 20~100Hz Range 10~500V Accuracy 0.5% Power 1200VA(400V) Binary inputs Load time <1A : continuous 1~3A : Max 60min Number Input characteristics 2 30~250V DC, or dry contact Specifications Time resolution 1ms(0.001~1s) 0.1%(1~9999.999s) High power DC voltage output (Udc) Max. measuring time 9999.999s Range 10~300V High power AC current output (I1) Accuracy 0.5% Power (300V) 750W(300V) Binary output Range 2A~50A, 50A~1000A Load time Output : < 1A >1 A continuous Max 60min Number 1 Output voltage 20V 7V Time : Type Potential free relay contacts Accuracy 0.5% Binary inputs Break capacity AC Vmax 250V AC / Imax 8A / Pmax 2000VA Power 7000VA Auxiliary DC voltage output (Aux Udc) Break capacity DC Vmax 250V DC/ Imax 8A / Pmax 150W Number 2 ( auto detection ) Range 20~240V Load time 120s at 1000A Input characteristics 30 ~ 250Vdc, or potential free Accuracy 1% Time resolution 1ms ( 0.001~1s ) 0 . 1% ( 1~9999.999s ) Power 55W at 110V/110W at 220V Power supply High power AC voltage output (U1) Load time continuous at 0.5A Max. measuring time 9999.999s Nominal input voltage 110/220Vac Range 10~250V Permissible tolerance -20% ~+15% Accuracy 0.5% AC/DC current output (I2) Nominal frequency 50/60Hz Power 750VA(250V) Binary output Mode AC output DC output Load time continuous 1 Permissible frequency 45~65Hz Number Range 0~20A 0~20A Potential free relay contacts Type Accuracy 0.5% 0.5% High power DC voltage output (Udc) Break capacity AC Vmax 250V AC / Imax 5A / Pmax 1250VA Power(20A) 200VA 200W Voltmeter Range 10~300V Vmax 250V DC/ Imax 5A / Pmax 150W Break capacity DC Frequency 20~100Hz Range 0~600V AC/DC Accuracy 0.5% Phase angle 0~360 Accuracy 1% Power 750W(300V) Phase angle accuracy 0.5 Load time Output : < 1A >1 A Power supply Distortion 1A~20A <0.5% Time : continuous Max 60min Nominal input voltage 220VAC15% Transient response 500s Ammeter frequency 45~65Hz Load time 20A : 60s Range 0~6A AC/DC Auxiliary DC voltage output (Aux Udc) 10A : 240s Accuracy 1% Range 20~240V <10A : continuous Accuracy 1% Others Harmonic(2nd,3rd,5th,7th)accuracy 1% Certificates Power 55W at 110V/110W at 220V Operation temperature -5 ~ +50C EMC (Emission) IEC-61000-3-2/3 Load time continuous at 0.5A Operation humidity 5 ~95 %, non-condensing AC/DC voltage output (U2) EMC (Immunity) IEC 61000-4-2/3/4/5/6/11 Weight 37kg Safety IEC 61010-1 Ammeter Dimensions (W x H x D) 260 330500 mm Mode AC output DC output PC connection Range 0~6A AC direct measurement USB Range 0~120V 0~120V Ground Socket (earth) 4 mm banana socket; front panel 0.5% 0.5% Others 0~2000A AC with external CT Accuracy 60VA 80W Accuracy 1% Power(120V) Operation temperatur - 5 ~ +45C Frequency 20~100Hz Operation humidity 5 ~95 %, non-condensing Certificates Phase angle 0~360 Weight 23kg Voltmeter EMC (Emission) IEC-61000-3-2/3 Phase angle accuracy 0.5 Dimensions (W x H x D) Range 0~600V AC/DC EMC (Immunity) IEC 61000-4-2/3/4/5/6/11 440 mm255mm255 mm Distortion 5V~120V PC connection Accuracy 1% Safety IEC 61010-1 <0.5% USB Transient response 500s 500s Ground Socket (earth) 4 mm banana socket; front side