Вы находитесь на странице: 1из 9

Job Number Sheet

Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

S19
Flexible End Plate Connection - Ver W2.6.02 - 04 Jul 2014

Title : Example
Code of Practice : SABS 0162 - 1993
Created : 12/16/2017 2:42:12 PM

Notes and Assumptions


1 Bolts are referred to by column and row number. Columns are
numbered from left to right, and rows from top to bottom.
2 All bolt holes are assumed to be normal clearance holes.
3 All bolts are assumed to have threads in their shear planes.

Summary

Summary of Forces and Capacities for Design to SABS 0162 - 1993

Check Member Type LC Applied Capacity Units % of Cap. ?

1 Plate Length/Beam Depth N/A 0.6 0.6 Ratio 98.2 O.K.

2a Bolts Shear D+L 39.8 10.2 kN 389.1 Fail

2b Bolts Tension D+W 41.2 17 kN 241.6 Fail

2c Bolts Combined D+W 5.6 1.4 Ratio 402.7 Fail

2d Bolts Slip N/A N/A N/A kN N/A N/A

2e Bolts Slip + Ten. N/A N/A N/A Ratio N/A N/A

3a Plate Linear Shear 1 D+L 318.4 357.8 kN 89 O.K.

3a Plate Linear Shear 2 D+L 318.4 280.8 kN 113.4 Fail

3b Plate Bearing 1 D+L 39.8 38.6 kN 103.1 Fail

3b Plate Bearing 2 D+L 39.8 37.5 kN 106.1 Fail

4 Column Bearing D+L 39.8 67.5 kN 58.9 O.K.

5 Weld Strength D+W 0.8 0.5 kN 165.5 Fail


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Input

Bolt Shear Analysis Non-Linear


BoltType Bearing
Bolt Grade 3.6
Bolt Size (mm) 12
Member Ultimate Strength (MPa) 200
Member Yield Strength (MPa) 150
Weld Ultimate Strength (MPa) 200
Weld Size (mm) 8

Member Type Designation


Column H-sections (Parallel flange) 254x254x73
Beam I-sections (Parallel flange) 406x140x39

Beam angle 15.0


Plate height (mm) 251
Plate width (mm) 160
Plate thickness (mm) 8
Plate offset from top of beam (mm) 32

Plate Connected to : Flange

Connection
Columns of Bolts 1
Rows of Bolts 4
Top Edge (mm) 35
Side Edge (mm) 38
Column Pitch (mm) Not Applicable
Row Pitch (mm) 60
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Shear
Axial

Loads
Ultimate Loads Service Loads
Load Case
Shear (kN) Axial (kN) Shear (kN) Axial (kN)
D+L 260 260
D+W 340 -250

Plan Section
14 226 8
38
254

142

254 0
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Elevation

35
60

Beam Section
35
60
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Check 1 : Recommended Detailing Requirements

Plate_Height
Ratio =
Beam_Depth
251
=
411
= 0.6107

OK

Check 2a : Shear Capacity of the Bolts


The worst load is encountered for Load Case : D+L
when Vmax =39.804 kN

13.11.2
The resistance of any bolt is :

0.75 . 0.60 . fb. m . Ab. f u


Vr =
1000
0.75 0.60 0.67 1 113.097 300
=
1000
= 10.230 kN

Bolt shear failure

Check 2b : Tension Capacity of the Bolts


Depending on the sign of the applied moment, the connection is
deemed to rotate about either the topmost or bottommost row of
bolts. The tensile force due to the moment is added to the
direct tensile force (if any) before doing this check.

The worst load is encountered for Load Case : D+W


when Tmax =41.185 kN

13.11.3
The resistance of any bolt is :

0.75 . f b. Ab. f u
Tr =
1000
0.75 0.67 113.097 300
=
1000
= 17.049 kN

Bolt tension failure

Check 2c : Combined Capacity of the Bolts


Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

The worst load is encountered for Load Case : D+W

The factor must be less than or equal to 1.4 : 13.11.4


Vu Tu
Factor = +
Vr Tr
42.5 41.185
= +
10.23 17.049
= 6.570

Bolts shear & tension failure

Check 3a: Shear Capacity of the Plate


The worst load is encountered for Load Case : D+L
when Vmax =318.434 kN
The Linear Shear Capacity of the Plate is the lesser of :

13.4.4a
2 . 0.66 . f . L . t . f y
Vr =
1000
2 0.66 0.9 251 8 150
=
1000
= 357.826 kN

13.4.4b
2 . 0.50 . f . Ln. t . f u
Vr =
1000
2 0.50 0.9 195 8 200
=
1000
= 280.800 kN

Plate shear failure

Check 3b: Bearing Capacity of the Plate


The Bearing Capacity of the Plate at any Bolt is the lesser of :

The worst load is encountered for Load Case : D+L


when Bmax =39.804 kN
3 . f . t. d. f u
13.10.1c-1
Br =
1000
3 0.67 8 12 200
=
1000
= 38.592 kN

And
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

With the maximum force at the Bolt in the bottom row


for Load Case : D+L
when Bmax =39.804 kN
13.10.1c-1
f . t. a. fu
Br =
1000
0.67 8 35 200
=
1000
= 37.520 kN

Plate bearing failure

Check 4: Bearing Capacity of the Column


The worst load is encountered for Load Case : D+L
when Bmax =39.804 kN

Since the edge distance is deemed to be more than three times the bolt
diameter, only one check is necessary.
The Bearing Capacity of the column at any Bolt is :
13.10.1c-1
3 . f . t. d. fu
Br =
1000
3 0.67 14 12 200
=
1000
= 67.536 kN

Column bearing is safe

Check 5 : Capacity of the Weld


The worst load is encountered for Load Case : D+W
when Fmax =0.841 kN/mm

The Capacity of weld is the lesser of : 13.13.1

Table 3 (a)
0.67 . fw. Aw. f uw
Vr =
1000
0.67 0.67 5.657 200
=
1000
= 0.5079 kN/mm

0.67 . f . Am. f y
Table 3 (b)
Vr =
1000
0.67 0.9 8 150
=
1000
= 0.7236 kN/mm
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Weld failure
Job Number Sheet
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date

Bolt Forces

Flexible End Plate Connection


Ver W2.6.02 - 04 Jul 2014
Title : Example
Created : 12/16/2017 2:42:12 PM

The bolt forces listed here are the forces that the column is exerting
on the applicable bolt. X-forces are positive to the right, Y-forces are
positive upwards.

COLUMN BOLT FORCES (kN) FOR LOAD COMBINATION : D+L


BOLT ULTIMATE APPLIED LOAD SERVICE APPLIED LOAD
Row Tensile Shear Tensile Shear
---------------------------------------------------

1 -22.98 -39.80 ---------- ----------


2 -22.98 -39.80 ---------- ----------
3 -22.98 -39.80 ---------- ----------
4 -22.98 -39.80 ---------- ----------

COLUMN BOLT FORCES (kN) FOR LOAD COMBINATION : D+W


BOLT ULTIMATE APPLIED LOAD SERVICE APPLIED LOAD
Row Tensile Shear Tensile Shear
---------------------------------------------------

1 41.18 -32.96 ---------- ----------


2 41.18 -32.96 ---------- ----------
3 41.18 -32.96 ---------- ----------
4 41.18 -32.96 ---------- ----------