Вы находитесь на странице: 1из 18

NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Water Absorption of Stone Boulder


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE-1/IIMPD-I/2016-17 Dated: 01.11.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Ref. code : IS 1124 : 1974

Results of Test Performed


Sample Weight Weight of weight of Water Average Remarks
of oven-dry test saturated Absorption Water
Sample piece in gm surface-dry ((B- Absorption
Taken A test piece in A)/A)*100 (%)
in gm gm B
St-1 1000 971 988 1.75
St-2 1000 975 993 1.85
St-3 1000 979 990 1.12
St-4 1000 976 986 1.02 Recommended for
St-5 1000 969 984 1.55 1.43 construction as
St-6 1000 971 985 1.44 per IS 3622:1977
St-7 1000 978 991 1.33
St-8 1000 965 982 1.76
St-9 1000 968 980 1.24
St-10 1000 973 985 1.23

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Dated:

Type of Test : Transverse Strength of Stone Boulder


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE-1/IIMPD-I/2016-17 Dated: 01.11.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Ref. code : IS 1121(Part II) : 1974
Results of Test Performed
Sample Length Average Average Central Transverse Average Remarks
of width depth breaking strength in Transverse
span in cm in cm load in kg/sq.cm strength in
in cm (b) (d) kg R=(3WL/2bd2) kg/sq.cm
(L) (W)
St-1 20 5 5 320 76.80
St-2 20 5 5 321 77.04
St-3 20 5 5 317 76.08
Recommended
St-4 20 5 5 323 77.52 for
St-5 20 5 5 326 78.24 77.81 construction
St-6 20 5 5 324 77.76 as per IS
St-7 20 5 5 328 78.72 3622:1977
St-8 20 5 5 331 79.44
St-9 20 5 5 330 79.20
St-10 20 5 5 322 77.28

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Resistance to wear of Stone Boulder


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE-1/IIMPD-I/2016-17 Dated: 01.11.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Ref. code : IS 1706 : 1972
Results of Test Performed
Sample Initial Final Initial Surface Loss in Average Remarks
weight of weight of volume Area of thickness loss in
the the of the the t=[(W1-W2) thickness
Specimen Abraded Specimen Specimen *V1 ] /(W1*A) (mm)
W1 (g) Specimen V1 (cm3) A (cm2) (mm)
W2 (g)
St-1 565 443 125 25 1.08
St-2 572 448 125 25 1.08
St-3 569 453 125 25 1.02
Recommended
St-4 575 457 125 25 1.03 for
St-5 572 450 125 25 1.07 1.04 construction
St-6 569 454 125 25 1.01 as per IS
St-7 568 444 125 25 1.09 3622:1977
St-8 565 452 125 25 1.00
St-9 570 456 125 25 1.00
St-10 568 453 125 25 1.01

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Water Absorption of Stone Boulder


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE-1/IIMPD/2016-17 Dated: 29.11.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Ref. code : IS 1124 : 1974

Results of Test Performed


Sample Weight Weight of weight of Water Average Remarks
of oven-dry test saturated Absorption Water
Sample piece in gm surface-dry ((B- Absorption
Taken A test piece in A)/A)*100 (%)
in gm gm B
St-1 1000 969 988 1.96
St-2 1000 975 993 1.85
St-3 1000 983 996 1.32
St-4 1000 965 979 1.45 Recommended for
St-5 1000 969 984 1.55 1.52 construction as
St-6 1000 979 991 1.23 per IS 3622:1977
St-7 1000 969 981 1.24
St-8 1000 963 982 1.97
St-9 1000 968 980 1.24
St-10 1000 981 995 1.43

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Dated:

Type of Test : Transverse Strength of Stone Boulder


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE-1/IIMPD/2016-17 Dated: 29.11.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Ref. code : IS 1121(Part II) : 1974
Results of Test Performed
Sample Length Average Average Central Transverse Average Remarks
of width depth breaking strength in Transverse
span in cm in cm load in kg/sq.cm strength in
in cm (b) (d) kg R=(3WL/2bd2) kg/sq.cm
(L) (W)
St-1 20 5 5 326 76.24
St-2 20 5 5 321 77.04
St-3 20 5 5 317 76.08
Recommended
St-4 20 5 5 324 77.76 for
St-5 20 5 5 326 78.24 78.00 construction
St-6 20 5 5 324 77.76 as per IS
St-7 20 5 5 329 78.96 3622:1977
St-8 20 5 5 331 79.44
St-9 20 5 5 330 79.20
St-10 20 5 5 322 77.28

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Resistance to wear of Stone Boulder


Clients : IIMPD-II, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE-1/IIMPD/2016-17 Dated: 29.11.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Ref. code : IS 1706 : 1972
Results of Test Performed
Sample Initial Final Initial Surface Loss in Average Remarks
weight of weight of volume Area of thickness loss in
the the of the the t=[(W1-W2) thickness
Specimen Abraded Specimen Specimen *V1 ] /(W1*A) (mm)
W1 (g) Specimen V1 (cm3) A (cm2) (mm)
W2 (g)
St-1 565 446 125 25 1.05
St-2 572 449 125 25 1.08
St-3 569 453 125 25 1.02
Recommended
St-4 575 459 125 25 1.01 for
St-5 572 450 125 25 1.07 1.05 construction
St-6 569 439 125 25 1.14 as per IS
St-7 568 444 125 25 1.09 3622:1977
St-8 565 452 125 25 1.00
St-9 570 456 125 25 1.00
St-10 568 453 125 25 1.01

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Water Absorption of Stone Boulder


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE-1/IIMPD/2016-17/01 Dated: 03.10.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Ref. code : IS 1124 : 1974

Results of Test Performed


Sample Weight Weight of weight of Water Average Remarks
of oven-dry test saturated Absorption Water
Sample piece in gm surface-dry ((B- Absorption
Taken A test piece in A)/A)*100 (%)
in gm gm B
St-1 1000 976 987 1.13
St-2 1000 975 986 1.13
St-3 1000 983 993 1.02
St-4 1000 973 983 1.03 Recommended for
St-5 1000 969 984 1.55 1.30 construction as
St-6 1000 979 991 1.23 per IS 3622:1977
St-7 1000 969 981 1.24
St-8 1000 963 982 1.97
St-9 1000 968 980 1.24
St-10 1000 981 995 1.43

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Dated:

Type of Test : Transverse Strength of Stone Boulder


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE-1/IIMPD/2016-17/01 Dated: 03.10.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Ref. code : IS 1121(Part II) : 1974
Results of Test Performed
Sample Length Average Average Central Transverse Average Remarks
of width depth breaking strength in Transverse
span in cm in cm load in kg/sq.cm strength in
in cm (b) (d) kg R=(3WL/2bd2) kg/sq.cm
(L) (W)
St-1 20 5 5 319 76.56
St-2 20 5 5 321 77.04
St-3 20 5 5 320 76.8
Recommended
St-4 20 5 5 326 78.24 for
St-5 20 5 5 326 78.24 77.98 construction
St-6 20 5 5 324 77.76 as per IS
St-7 20 5 5 329 78.96 3622:1977
St-8 20 5 5 332 79.68
St-9 20 5 5 330 79.20
St-10 20 5 5 322 77.28

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Resistance to wear of Stone Boulder


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE-1/IIMPD/2016-17/01 Dated: 03.10.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Ref. code : IS 1706 : 1972
Results of Test Performed
Sample Initial Final Initial Surface Loss in Average Remarks
weight of weight of volume Area of thickness loss in
the the of the the t=[(W1-W2) thickness
Specimen Abraded Specimen Specimen *V1 ] /(W1*A) (mm)
W1 (g) Specimen V1 (cm3) A (cm2) (mm)
W2 (g)
St-1 575 448 125 25 1.10
St-2 572 449 125 25 1.08
St-3 569 454 125 25 1.01
Recommended
St-4 579 459 125 25 1.04 for
St-5 572 450 125 25 1.07 1.05 construction
St-6 569 439 125 25 1.14 as per IS
St-7 568 444 125 25 1.09 3622:1977
St-8 565 452 125 25 1.00
St-9 570 456 125 25 1.00
St-10 568 453 125 25 1.01

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Coarse Aggregates Test (40 mm)

Clients : IIMPD, CPWD, Dhankheti, Shillong

Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)

Ref. No. : Camp/AE/IIMPD/2016-17 Dated- 10.11.2016

Name of Contractor : Shree Gautam Construction Co. Ltd

Sample supplied by : Shree Gautam Construction Co. Ltd

Results of Test Performed

Sl. Limits as per Indian


Type of test Codal Procedure Results
No. Standard codes
IS 2386 (Part I): Class: Medium
1 Sieve analysis IS 383 - 1970
1963 Size :40 to 20 mm
Flakiness Index (FI) & FI 13.628 Max. of 40%
IS 2386 (Part I):
2 Elongation Index (EI) [IS 383-1970 3rd
1963 EI 14.389
(%) Revision]
IS 2386 (Part IV): Max. of 45% [IS 383-
3 Crushing Value (%) 29.99
1963 1970]
Aggregate Abrasion IS 2386 (Part IV): Max. of 50% [IS 383-
4 28.56
Value (%) 1963 1970]

References:
1. IS 2386-1963. Methods of test for aggregates for concrete
2. IS 383-1970. Specification for coarse and fine aggregate

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Coarse Aggregates Test (20 mm)

Clients : IIMPD, CPWD, Dhankheti, Shillong

Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)

Ref. No. : Camp/AE/IIMPD/2016-17 Dated- 10.11.2016

Name of Contractor : Shree Gautam Construction Co. Ltd

Sample supplied by : Shree Gautam Construction Co. Ltd

Results of Test Performed

Sl. Limits as per Indian


Type of test Codal Procedure Results
No. Standard codes
IS 2386 (Part I): Class: Small
1 Sieve analysis IS 383 - 1970
1963 Size :20 to 4.75 mm
Flakiness Index (FI) & FI 15.029 Max. of 40%
IS 2386 (Part I):
2 Elongation Index (EI) [IS 383-1970 3rd
1963 EI 22.135
(%) Revision]
IS 2386 (Part IV): Max. of 45% [IS 383-
3 Crushing Value (%) 27.99
1963 1970]
Aggregate Abrasion IS 2386 (Part IV): Max. of 50% [IS 383-
4 28.56
Value (%) 1963 1970]

References:
1. IS 2386-1963. Methods of test for aggregates for concrete
2. IS 383-1970. Specification for coarse and fine aggregate

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Cement Test


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE/IIMPD/2016-17 Dated: 01.11.2016
Name of Contractor : Shree Gautam Construction Co. Ltd.
Sample supplied by : Shree Gautam Construction Co. Ltd.
Sample : TOPCEM PPC

Results of Test Performed

Sl. Limits as per Indian


Type of test Codal Procedure Results
No. Standard codes
IS 4031 (Part I):
1 Fineness (%) 6.67 -
1988
Standard Consistency IS 4031 (Part IV):
2 31 -
(%) 1988
IS 4031 (Part V): Initial 229
3 Setting Time (min) IS 1489 (Part 1) : 1991
1988 Final 396
Compressive Strength IS 4031 (Part VI): 7 days 23.82
4 IS 1489 (Part 1) : 1991
(MPa) 1988 28 days 34.21

References:
1. IS 4031 : 1988. Method Of Physical Tests For Hydraulic Cement
2. IS 1489 (Part 1) : 1991. Portland-Pozzolana Cement - Specification

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Cement Test


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE/IIMPD/2016-17 Dated : 27.09.2016
Name of Contractor : Shree Gautam Construction Co. Ltd.
Sample supplied by : Shree Gautam Construction Co. Ltd.
Sample : TOPCEM PPC

Results of Test Performed

Sl. Limits as per Indian


Type of test Codal Procedure Results
No. Standard codes
IS 4031 (Part I):
1 Fineness (%) 7.1 -
1988
Standard Consistency IS 4031 (Part IV):
2 30.5 -
(%) 1988
IS 4031 (Part V): Initial 225
3 Setting Time (min) IS 1489 (Part 1) : 1991
1988 Final 392
Compressive Strength IS 4031 (Part VI): 7 days 23.62
4 IS 1489 (Part 1) : 1991
(MPa) 1988 28 days 34.18

References:
1. IS 4031 : 1988. Method Of Physical Tests For Hydraulic Cement
2. IS 1489 (Part 1) : 1991. Portland-Pozzolana Cement - Specification

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Cement Test


Clients : IIMPD-II, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE/IIMPD/2016-17 Dated : 12.10.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Sample : TOPCEM PPC

Results of Test Performed

Sl. Limits as per Indian


Type of test Codal Procedure Results
No. Standard codes
IS 4031 (Part I):
1 Fineness (%) 6.98 -
1988
Standard Consistency IS 4031 (Part IV):
2 31.5 -
(%) 1988
IS 4031 (Part V): Initial 232
3 Setting Time (min) IS 1489 (Part 1) : 1991
1988 Final 393
Compressive Strength IS 4031 (Part VI): 7 days 23.95
4 IS 1489 (Part 1) : 1991
(MPa) 1988 28 days 34.12

References:
1. IS 4031 : 1988. Method Of Physical Tests For Hydraulic Cement
2. IS 1489 (Part 1) : 1991. Portland-Pozzolana Cement - Specification

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Cement Test


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE/IIMPD/2016-17 Dated : 02.11.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Sample : TOPCEM PPC

Results of Test Performed

Sl. Limits as per Indian


Type of test Codal Procedure Results
No. Standard codes
IS 4031 (Part I):
1 Fineness (%) 7.12 -
1988
Standard Consistency IS 4031 (Part IV):
2 29.5 -
(%) 1988
IS 4031 (Part V): Initial 228
3 Setting Time (min) IS 1489 (Part 1) : 1991
1988 Final 397
Compressive Strength IS 4031 (Part VI): 7 days 24.12
4 IS 1489 (Part 1) : 1991
(MPa) 1988 28 days 34.15

References:
1. IS 4031 : 1988. Method Of Physical Tests For Hydraulic Cement
2. IS 1489 (Part 1) : 1991. Portland-Pozzolana Cement - Specification

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Compressive Strength of Concrete Cubes


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE/IIMPD//2016-17 Dated 02.12.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Grading of Concrete : M 25

Results of Test Performed

Limits as per
Compressive Mean Codal
Sl Load in Area in Indian
Strength in Compressive Procedure
No. KN mm2 Standard
MPa Strength in MPa
codes
(After 28 days)
1 720 22500 32.00

2 680 22500 30.22 IS 456 :2000


30.37 IS 516
650 28.89 :1959
3 22500

References:
1. IS 516:1959. Methods of test for Strength of concrete
2. IS 456:2000. Plain And Reinforced Concrete Code Of Practice

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Compressive Strength of Concrete Cubes


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE/IIMPD//2016-17 Dated 02.12.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Grading of Concrete : M 25

Results of Test Performed

Limits as per
Compressive Mean Codal
Sl Load in Area in Indian
Strength in Compressive Procedure
No. KN mm2 Standard
MPa Strength in MPa
codes
(After 28 days)
1 690 22500 30.67

2 675 22500 30.00 IS 456 :2000


30.30 IS 516
680 30.22 :1959
3 22500

References:
1. IS 516:1959. Methods of test for Strength of concrete
2. IS 456:2000. Plain And Reinforced Concrete Code Of Practice

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te
NATIONAL INSTITUTE OF TECHNOLOGY, MEGHALAYA

DEPARTMENT OF CIVIL ENGINEERING


Bijni Complex, Laitumkhrah, Shillong-793003
Phone: 0364- 2501294

Ref. No. : NITMGH/Cons/CE/2016-17/ Date:

TEST REPORT

Type of Test : Compressive Strength of Concrete Cubes


Clients : IIMPD, CPWD, Dhankheti, Shillong
Name of Work : Construction of Retaining Wall behind Academic Block-A (SH: C/O
RCC Retaining Wall, Random Rubble Retaining Wall with brick work
wall and box drain behind Academic Block-A including site grading
& preparation.)
Ref. No. : Camp/AE/IIMPD//2016-17 Dated 02.12.2016
Name of Contractor : Shree Gautam Construction Co. Ltd
Sample supplied by : Shree Gautam Construction Co. Ltd
Grading of Concrete : M 25

Results of Test Performed

Limits as per
Compressive Mean Codal
Sl Load in Area in Indian
Strength in Compressive Procedure
No. KN mm2 Standard
MPa Strength in MPa
codes
(After 28 days)
1 675 22500 30.00

2 690 22500 30.67 IS 456 :2000


30.07 IS 516
665 29.56 :1959
3 22500

References:
1. IS 516:1959. Methods of test for Strength of concrete
2. IS 456:2000. Plain And Reinforced Concrete Code Of Practice

(K. Kharmih) (Dr. C. Marthong)


Technical Assistant Faculty in charge
Te

Вам также может понравиться