Академический Документы
Профессиональный Документы
Культура Документы
BS-SAN-Y-1002-01 BLUESTONE SANFORD M&R SITE MAIN GAS RECEIVER P&I DIAGRAM 7
5
BS-SAN-Y-1002-02 BLUESTONE SANFORD M&R SITE MAIN GAS SUCTION FILTER SEPARATOR P&I DIAGRAM 6
6
BS-SAN-Y-1008-01 BLUESTONE SANFORD M&R SITE POWER GAS, INSTRUMENT GAS DISTRIBUTION P&I DIAGRAM 5
13
BS-SAN-Y-1012-01 BLUESTONE SANFORD M&R SITE WASTE WATER TANK LOW PRESSURE SEPARATOR P&I DIAGRAM 5
14
BS-SAN-Y-903-01 BLUESTONE SANFORD M&R SITE OPP BUILDING & REGULATOR PIPING PLAN 6
19
BS-SAN-Y-903-02 BLUESTONE SANFORD M&R SITE REGULATOR AREA PIPING SECTIONS AND DETAILS 3
20
BS-SAN-Y-904-02 BLUESTONE SANFORD M&R SITE METERING AREA PIPING SECTIONS AND DETAILS 3
22
BS-SAN-Y-905-01 BLUESTONE SANFORD M&R SITE SUCTION FILTER SEPARATOR PIPING PLAN 6
23
BS-SAN-Y-905-03 BLUESTONE SANFORD M&R SITE SUCTION FILTER SEPARATOR PIPING SECTIONS AND DETAILS 2
24
BS-SAN-Y-906-01 BLUESTONE SANFORD M&R SITE FUEL GAS & WASTE WATER TANK PIPING PLAN 6
25
BS-SAN-Y-906-02 BLUESTONE SANFORD M&R SITE FUEL GAS PIPING SECTIONS AND DETAILS 3
26
BS-SAN-Y-906-03 BLUESTONE SANFORD M&R SITE VENT FLARE & FUEL GAS PIPING SECTIONS AND DETAILS 3
27
BS-SAN-Y-907-01 BLUESTONE SANFORD M&R SITE FILTER SEPERATOR YARD PIPING PIPING PLAN 6
28
BS-SAN-Y-907-02 BLUESTONE SANFORD M&R SITE FILTER SEPERATOR YARD PIPING, PIPING SECTIONS AND DETAILS 3
29
BS-SAN-Y-908-01 BLUESTONE SANFORD M&R SITE FLARE AND VERTICAL KNOCKOUT DRUM PIPING PLAN 6
30
BLUESTONE SANFORD M&R SITE FLARE AND VERTICAL KNOCKOUT DRUM PIPING SECTIONS AND
BS-SAN-Y-908-02 3
31 DETAILS
BS-SAN-Y-913-02 BLUESTONE SANFORD M&R SITE YARD PIPING SECTIONS & DETAILS 1
33
BS-SAN-Y-914-02 BLUESTONE SANFORD M&R SITE YARD PIPING SECTIONS & DETAILS 1
35
Notes:
1 - Second letter 'S,' 'switch,' is preferred for devices connected to PLC/DCS/Relay control panels.
2 - The letters 'H' and 'L' may be omitted in the undefined case.
3 - Use second Letter 'V' for 'valve' and second letter 'Z' for 'actuator/driver.'
4 - Use 'EY' for relays; use 'EV' for solenoid valves that actuate process valves.
5 - 'N/A' is Not Applicable
6 - Use 'PY' for I/P (Current-to-pneumatic) transducers; 'IP' is used for measurements of electrical current.
7 - Used for exceptions and unclassified instruments - define the device adjacent to the tag name bubble.
8 - 'ZSO' is used for a 'Opened' position, 'ZSC' is used for a 'Closed' position (e.g., valve limit switches.)