1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

A
6x Silo scale
in proces A

□ 3.350
18x CL-2-1233 each side
Wall opening 615x325

1.500 615

1.000
3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400

3.400 1.585

B B

JetMaster P100 6E50

3.000
3.000 40.000 18.500

2x Fan
FF063
1.500 Nipple drinker 19,5 x 3.000-15 = 58.500 1.500
3.000

EM50
9.500

Fan
C C
1.415 2.775 Augermatic with FLUXX330-14 18,5 x 3.000-4 = 55.500 620 1.190

1x Augermatic drive each Line Pressure regulator unit

FF091
Fan
1x existing drinker!

FF063
18.500 40.000 3.000 Bemaßung / Dimension

Fan
min. 500 6E50 min. 500 JetMaster P100
Text

D Gebäude / Building D

System
1.500 3.400 3.400 2.585 4.215 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 3.400 4.300 2.500 3.400 3.400 1.585
Futter / Feeding
615
61.500
Wasser / Water

Zuluft / Climate Air In

E Abluft / Climate Air Out E

Heizung / Climate Temperature

The grounding of the silo has to be integrated to the local


Silo BD-P-EU WL2 Eiersammlung / Eggbelt
grounding system or to the local equipotential bonding.
27,0 m³ The corresponding local / national regulations must be observed!
Elektronik / Electric

∅ 2.750 Entmistung / Manure

F Kotbandbelüftung / Manure Air F

Sensor Licht / Light


Flex Vey drive

7.190
Sonstiges / General
1x existing drinker NB: Guidance for tension rod Flex Vey 75 1x existing drinker 1x JetMaster P100 each side
Flex Vey 75
CL-2-1233 1x 6E50 each side Schraffur / Hatch
Wall opening 615x325
Wind protection to be made locally, Schnittlinie / Cutline
on account of customer
5.000

5.000
G Mittellinie / Centerline G

Verdeckt / Invisible

3.000

3.000
18x CL-2-1233 Umriss 2 / Outline 2

325
6x Silo scale
each side

1.500

1.500
700 700 Vorhanden / Existing

1.100

35°
H Attention !

400 400
- All dimensions have to be checked by the building owner/site supervision responsible.

100
- Safety regulations, structural and static characteristics, construction planning, construction work and maintenance of the building
have to be verified by the construction supervisor according to national and local building standards and regulations.

1.150 900 900 900 900 900 900 900 900 1.150 1.150 900 900 900 900 900 900 900 900 1.150 - Observe local execution regulations for live stock keeping!

- Observe the assembly manuals.


9.500 □ 3.350 1.000 9.500 - Complete mounting of the safety devices.
- Planning of suitable earthing points for the foundation earth electrode.
- Earthing of the system at suitable places according to the locally valid guidelines and standards (e.g. VDE 0100 part 705).

- Insulation and vapour seal have to be installed according to today's standard.


I - Avoid the installation of constructional obstacles and resistances (profiles, beams, cables,lamps or pipes) in the fresh air flow.
- The ceiling has to be even and smooth (no joists, Z-profiles etc.).

Wall opening 615x325


Winch drive
1x EM50
Wall opening: □1.400
18x CL-2-1233
J

325
each side Wire rope
1x FF091 3x FF063
Wall opening
5.000

Wall opening: ∅980 Wall opening: ∅670 Rev.-No Instruction by Revision Record Date Name
NB: Guidance for tension rod Pulley Tension rod for last air inlet Customer
Fixed point
Fereman Group SRL

615
I. C. Bratianu nr. 1
3.000
1.400

min. Wall opening min.


1.000 for first air inlet 1.000 710319 BOTOSANI RO
Handled Name Date Description
Big Dutchman
Wind protection to be made locally, fsiemer 11.01.2016 Broiler management (floor)
1.500

International GmbH
on account of customer Standard 1.500 Standard 1.500 Status
House wide: 61,50m x 9,50m
K in process
800

P.O.Box: 11 63
Grade interim publish invalid 3 x feed, 5 x water
D-49360 Vechta Contact Name Telephone no. Place of building
T
+4
e
:9
l0
(4
)4478010
- Bosoanca, D.
Fa+x4
:90
(4
)4478012
-37 Necaev, I. +4904447 801-4278
big@bigdutchman.de Cusotme
nro. Quotation no. Order no. Drawing no. Sheet 1 of 1
XO-243205 (8) 2001878
www.bigdutchman.de
Scale 1:100 1:50 Size A1 L BD-106475 11
910 ∅670 745 ∅980 745 □1.400 900 ∅670 900 ∅670 910
Preliminary draft according to DIN ISO EN 4157. Copyright ©2015 in this drawing remains with the company Big Dutchman. All rights are reserved.
The drawing may not be reproduced, passed on to third parties or used in any other form without the consent of Big Dutchman.
L Any unlawful use will be dealt with by law without exception. Subject to change without notice.
9.500