Вы находитесь на странице: 1из 166

COMPANY Description AD-MARINE V

General RIG data

Rig type Self-Elevating Drilling Unit Cantilever Jack-Up

Unit flag PANAMA


Unit classification ABS
Rig shall be complay with SNAME specification Confirmed
IMO Certification yes
Which code version IMO MODU CODE SOLAS
Year of Construction 1981
Year of last upgrade 2000
China Ship Building
Construction Yard Co.koashiung
RIG EQUIPMENT LIST
A.UNIT SPECIFICATIONS
A.1 MAIN DIMENSIONS / TECHNICAL
DESCRIPTION
Light ship: Kips 15,305
Displacement at loadline: Kips 20,530
Hull length f 180
Hull width f 175
Hull depth f 25
Number of legs/length: no./ f 3/350
Leg length available below hull: Ft 300 f
Type of leg: triangular
Leg spacing (center to center):
Traverse: f/m 120 f
Longitudinal f/m 115 f
Independent leg or matt: Independent Leg
Spud can dimension f/m 39.67 f
Spud can height: f/m 15 f
sq. Ft /
Spud can footing area 1116.9 sq f
m2
yes for
Spud can jetting system:Low & High yes
each
Bottom jets: yes/no yes
Top jets: yes/no yes
Mat dimensions:
Length: Ft N/A
Width: Ft N/A
Depth: Ft N/A
Cantilever type: cantilever
Skid-off: yes/no
Cantilever envelope:
Reach AFT, from / to: f/f Rotary skid out 40' of transom
Transverse, port/stbd: f/f 12 f / 12 f
Total envelope f/f 40 f X 24 f
Slot dimensions: N/A
Length: Ft N/A
Width: Ft N/A
Mat slot dimensions: N/A
Length: Ft N/A
Width: Ft N/A
Max. cantilever load (combined): S.ton 1000 kips
Max. hook load: S.ton Max hook and setback 450 Kips
Max. rotary load: S.ton 750 kips
Max. setback load: S.ton 450 kips
Fuel Consumption (avg. drilling): bbl/day 81.5 bbl @ full load
Accommodation for max. # of personnel no. 100
A.2 STORAGE CAPACITIES
Installed with Tank gauging systems for
Fuel bbl 2061 bbl
Drilling water bbl 5486 bbl
Potable water bbl 1158 bbl
Mud processing tank bbl / m3
Active liquid mud bbl / m3 2226 bbl
Independent oil base mud storage: bbl / m3
Agitated yes/no N/A
Independent base oil storage bbl / m3
Independent brine storage bbl / m3 1335 bbl
Heavy brine accepted (e.g. bromide) yes/no yes
Bulk bentonite/barite f3 / m3 3,805 f3 (2,655 barite: 1,150 bentonite)
Bulk cement f3 / m3 4275 f3
Sack storage
Minimum 1500 sacks in covered storage.
CONTRACTOR to provide plan of the sack room Sacks 2000 sacks
storage area detailing access routes, stacking
heights, handling devices, etc.

In the event that the Drilling Unit is equipped with


a chemical dosing system, the CONTRACTOR
should provide details including types of bins, who
provides them and the storage space on board for
bins and sacks.

Pipe rack: f2 / m2 28’ x 32’


Upper racks dimensions: fxf 45 f * 45 f

Maximum load capacity: kips / mt 540 lb/f2

Lower rack dimensions: fxf 28f * 32 f


Miscellaneous storage area: f2 / m2 N/A
Operator storage area: f2 / m2 N/A
mt 25,199 Kips (11,430 metric tons)
mt
mt
Preload capacity (Required):
mt

mt (total)

Time to fill and dump preload: Hrs 12 hours


Zero Discharge :-

The rig MUST be fully panned and drained to a


central collection/containment facility so no
discharges can escape to the sea and/or onto the Yes/No Yes
Production Platform. This includes all areas of the
rig.

A.3 JACKUP SYSTEMS


A.3.1 Jacking Systems
Make/type: National NS-400
No. - jacks or pinions: no. 12*3 = 36
Maximum variable jacking load: Mt 418 Kips per pinion
Maximum variable holding load: Mt 700 Kips per pinion
Jacking speed: f/min 1.1 up/1.2 down f/min
Rack chocks available: yes/no yes
Required for field tow: yes/no no
Required for ocean tow: yes/no yes
A.3.2 Raw Water Systems
Quantity: no. 4
Pump location (water tower or leg): leg
Suction distance below hull (max): f/m 90 f
Make/Type: S&N submersible /KM400
Capacity: gal/min 1200 gpm / pump
@ pressure: Psi 100 psi
Horsepower: Hp 91 hp
Dedicated preload pumps:
Quantity: pump on board no. 3
Make/Type: S&N submersible /KM400
Capacity: bbl/min 1200 gpm / pump
@ pressure: Psi 100 psi
Horsepower: Hp 91 hp
A.4 OPERATIONAL CAPABILITIES
Maximum design water depth capability: Ft 250 f
Outfitted max/min water depth capability: Ft 250 f
Normal minimum water depth capability: Ft 25 f
Draf at load line (deepest): Ft 15.5 f
Drilling depth capability (rated): Ft 20000 f
Transit speed towed (historical avg.): 3 knots

Leg (spud can) below hull in transit (Field Move): Ft 0

Maximum leg length permitted in tow: 300 Ft


Ocean tow (Wet): Ft 295 Ft
Field tow: Ft 300Ft
Number of tugs for field tow: no. Minimum 3 with combined Bollard pull 140 ton
Associated minimum bollard pull per tug: St Minimum 3 with combined Bollard pull 140 ton
Anti-roll system: yes/no NO
Maximum preload reaction: Kips 25200
Bearing pressure at maximum preload: lb/f2 8
Thrusters: yes/no NO
Quantity: no. Nil
Fixed/Azimuthing N/A
Total horsepower per thruster: Hp N/A
A.5 VARIABLE LOAD CAPACITY (VL) inclusive of
drilling loads
Transit VL capacity: kips Mt 6876 kips
Drilling VL capacity: kips Mt 6000 kips
Survival VL capacity: kips Mt
Jacking VL capacity: kips Mt 4679 kips
A.6 ENVIRONMENTAL LIMITS
Jacking and Preload Condition
Max. wave height: Ft 5 Feet
Max. wave period: Sec 2
Knots /
Max. wind velocity 25 to 30 Knots
m/sec
Knots /
Max. current velocity: 2
m/sec
Max. heave (double amplitude): Ft
Max. pitch (single amplitude): degrees 2
Max. roll (single amplitude): degrees 2
Drilling @250 f water depth: N/A
Air gap (below bottom of main hull): f N/A
Leg Penetration f
Max. wave height: f 35 f
Max. wave period: Sec 13.5 sec
Knots /
Max. wind velocity: 70 knots
m/sec
Knots /
Max. current velocity: 2 knots
m/sec
A.7 MOORING SYSTEM
A.7.1 Anchor Winches
Quantity: no. 4
Make/model: skagit juw -074
Type (electric/hydraulic/diesel): Electric
Total HP per winch: Hp 50
Rated pull: Mt 54.7 kips
Control locations (local/remote/both): both
A.7.2 Anchors

4 no.
work in
Anchor hooks for rig approach if need sof and
hard soil.

Quantity: no. N/A


Make/type: N/A
Weight : lbs. N/A
A.7.3 Anchor Lines
Wire yes
Quantity: (installed + spare): no. 4
Make/type:
Construction: IWRC galvanized wire
Diameter: In 1-1/2 in
Useful length (nominal): Ft 2500 f
A.7.4 Towing Gear
Towing bridle size: 2 1/2
Hook-up system: hoist at bow
Rating: Mt 85 lt
Spare bridle: yes/no Spare emergency line available

A.7.5 Supply Vessel Mooring System


System description: Nylon Rope
Rating: Mt 5 lt
Location (port/stbd/both): port
A.8 MARINE LOADING HOSES
Location of loading manifolds (port/stbd/both): no. both
A.8.1 Potable Water Hoses
Quantity: no. 2
Size: in 3 inch
Make/type: goodall
Color coding: yes/no yes
Make/type connection: quicklock
A.8.2 Drilling Water Hose
Quantity: no. 2
Size: in 4 inch
Make/type: goodall
Color coding: yes/no yes
Make/type Self sealing & dry break hose connection
N/A
A.8.3 Gas/Fuel Oil Hose
Quantity: no. 2
Size: in 3 inch
Make/type: goodall
Color coding: yes/no yes
Make/type Self sealing & dry break hose connection: Yes
N/A
Safe system to prevent poulions ( double secured ). Yes/no N/A
A.8.4 Mud Chemical Hose (barite/bentonite)
Quantity: no. 2
Size: in 3 inch
Make/type: goodall
Color coding: yes/no yes
Make/type Make/type Self sealing & dry break hose
connection: N/A
Removable Screen yes/no N/A
A.8.5 Cement Hose
Quantity: no. 2
Size: in 3 inch
Make/type: goodall
Color coding: yes/no yes
Make/type Make/type Self sealing & dry break hose
yes/no
connection: N/A
Removable Screen yes/no N/A
A.8.6 Liquid Mud Hose
Quantity: no. 2
Size: in 5
Make/type: goodall
Color coding: yes/no Yes
Make/type Make/type Self sealing & dry break hose
yes/no
connection: No
A.8.7 Brine Hose N/A
Quantity: no. 2
Size: in 4
Make/type: Goodall
Color coding: yes/no Yes
Make/type Make/type Self sealing & dry break hose
yes/no
connection:
A.8.8 Other N/A
Use:
Quantity: no.
Size: in
Make/type:
Color coding: yes/no
Make/type connection:
Use: N/A
Quantity: no.
Size: in
Make/type:
Color coding: yes/no
Make/type connection:
Use: N/A
Quantity: no.
Size: in
Make/type:
Color coding: yes/no
Make/type connection:

A.9 CRANES, HOIST, AND MATERIAL HANDLING


A.9.1 Cranes, Revolving
Quantity: no. 2
IR
Specification (API, etc.):

Load Capability for crane ton 37 Ton / 20 Feet radius


Personal transfere Yes/no Yes
Make: weatherford
Type: AMERICAN AERO OM -455
Location (frwd/aft/port/stbd): port/stbd
Boom length: ft 100 f
Hook reach below main deck (block/whip): ft/ft 140
Block capacities and hoisting speeds: 79 f/min
Mt / m/
Load/radius/speed (minimum radius):
(m/s) 45 tons @ 20 f
Mt / m/ 45 tons @ 20 f - 158 f/min ;2 Part Line-
Load/radius/speed (maximum radius): 79 f/min ;4 Part Line
(m/s)

Whip capacity and hoist speed: Mt / (m/s)

Hook load indicator automatically: 8600 LBs


corrected for boom angle: yes/no yes
Alarm (audible, visual, both): yes
Automatic brake: yes/no no
Safety latch on hooks: yes/no yes
Crown saver (limit switch): yes/no yes
Boom illumination: yes/no yes
Load certification yes/no Yes
Certified Weight indicator yes/no yes
A.9.2 Forklifts
Quantity: no. 1
Make/type : YALE NR035AE
Rated capacity: Mt 1.5 ton
Explosion proof: yes/no no
A.9.3 Monorail Overhead Cranes N/A
All Monorails, Monorail Trolleys and Hoists shall be
Yes/no
marked with identification number and safe work loads.

All Monorails shall be fitted with end stop YesNo


Quantity: No.
Make:
Type:
Rated Capacity: St
Location(s):
Quantity: No.
Make:
Type:
Rated Capacity: St
Location(s):
A.9.4 Air Hoist/Derrick Winches
A.9.4.1 Rig Floor Winches (Non man-riding)
Quantity: No. 3
Make: ingersoll rand
Type: K6- UL
Rated capacity: s. ton 2.5
Wire diameter: mm 5/8 inch
Automatic brakes: yes/no yes
Overload protection: yes/no no
Automatic spooling: yes/no no
BOP Said Winches (Non man-riding)
Quantity: No. 4
Make: ingersoll rand
Type: K6- UL
Rated capacity: 2.5
Wire diameter: mm 5/8 inch
Automatic brakes: yes/no yes
Overload protection: yes/no no
Automatic spooling: yes/no no
A.9.4.2 Monkey Board Work Winch
Quantity: No. 1
Make: ingersoll rand
Type:
Rated capacity: Lbs 1000 lbs
Wire diameter: In
Automatic brake: yes/no yes
Overload protection: yes/no no
Automatic spooling: yes/no

A.9.4.3 Rig Floor “Man-Riding” Winch


Quantity: No. 1
Make:
Type: FA150KGMR
Rated capacity: Lbs 330 lbs
Wire diameter: In 3/8 inch
Non-twisted wire: yes/no yes
Automatic brakes: yes/no
Overload protection: yes/no
Automatic spooling: yes/no no
A.9.4.4 Utility Winch (i.e. Deck Winch) Towing bridle tugger?
Quantity: no. no
Make: no
Type: no
Rated capacity: s. ton no
Wire diameter: mm no
Automatic brakes: yes/no no
Overload protection: yes/no no
Automatic spooling: yes/no no
Certified for man-riding: yes/no no
Locations: no

Quantity: no.
Make:
Type:
Rated capacity: s. ton
Wire diameter: mm
Automatic brakes: yes/no
Overload protection: yes/no
Automatic spooling: yes/no
Certified for man-riding: yes/no
Locations:
Quantity: no.
Make:
Type:
Rated capacity: S. ton
Wire diameter: mm
Automatic brakes: yes/no
Overload protection: yes/no
Automatic spooling: yes/no
Certified for man-riding: yes/no
Locations:

A.9.4.5 BOP Hoists 2 ea


A.9.5 Transfer Baskets/Containers
No/Size
A.9.5.1Personnel Transfer Baskets 1 Billy Pugh Personnel transfer basket
No/type yes
A.9.5.2 Cargo Containers
Quantity: no.
Make/type:
A.10 HELICOPTER LANDING DECK
Location (frwd/aft/port/stbd): STBD
Dimensions: ft / ft 62 f dia
System:
Perimeter safety net: yes/no yes
Deck load capacity: lb/ft2 9 tons
Maximum helicopter weight: kips
Designed for helicopter type: sikorsky s-61N/ sikorsky s-92
Tie down points: yes/no yes
Covered by foam fire system : yes/no yes

A.10.1 Helicopter Refueling System N/A


System make/type:
Fuel storage capacity: gal
Jettisonable: yes/no
Fuel transport container, quantity: no.
Volume: gal
Fuel transport containers: no.
Volume: gal
Covered by foam fire system (see L.3.6) yes/no

A.11 AUXILIARY EQUIPMENT


A.11.1 Water Distillation
Quantity: no. 1
Make/type: Water line
Capacity (each/total): gal/day 8,600 gal / day

A.11.2 Boilers
Quantity: no. 3
Make/type: state industries inc
Capacity (total system): lbs/hr 360 us gal

A.11.3 Air Conditioning


Make/type: carrier /nance /chilled water unit
Capacity (total system): tons
Max/ Min . temperature rating: F

Make/type: carrier /nance /chilled water unit


Capacity (total system): tons
Max./ Min temperature rating: F

A.11.4 Electric Welding Sets


Quantity: no. 3
Current capacity: amp 40-400 amp
Make/model: lincoln
Welding type
Type (fixed/portable): fixed
A.11.5 High Pressure Cleaner
Quantity: no. 1
Make/type: MODELLO WS201
Electric/pneumatic/diesel: ELECTRIC
Max delivered pressure: psi 3000
With steam: yes/no NO
A.11.6 Orienting Fire Monitor
Quantity: No.
Position:
B.GENERAL RIG SPECIFICATIONS
B.1 DERRICK AND SUBSTRUCTURE
B.1.1 Derrick / Mast
Make/type: continental emsco model 20rd
Rated for wind speed
With full set back: knots 85.3(158 km/hr)
With no set back: knots
Height: ft / m 160 f
ft x ft / m
Dimensions of base:
xm 30 f *30 f
Dimensions of crown: ft x ft
Gross nominal capacity: lbs
Static hook load: lbs 1024000
Maximum number of lines: no. 12
Ladders with safety cages and rests: yes/no yes
Platform for crown sheave access: yes/no yes
Counter balance, system for rig tongs and
pipe spinning tong: yes/no yes
Lighting system explosion proof: yes/no yes

B.1.2 Racking Platform (Set Back)


Racking board
Make/type: manual-monkey board and finger boards
Total current simultaneous capacity - drill pipe:
Total amount of 5 ” DP (using the variable fingers) :
5” DP: Ft/Stands 18000 f
6 5/8” DP: Ft/Stands
3 1/2” DP: Ft/Stands 3-1/2 inch DP : 18000 f
4 3/4” DC: ft 9 jts
9 ¾” DC: Ft/Stands
Total yes (2)
Tubing belly board: yes/no

B.1.3 Automated Pipe Handling


Make/type:
Description:

B.1.4 Casing Stabbing Board


Make/type: pyramid
Adjustable from/to height above rotary: ft/ft 18 f 47 f
Safety locking system Yes/No

B.1.5 Substructure
Make/type: FRIDE & GOLDMAN -CANTILIVER
Drill floor height (above main deck): ft 26.25
Length: ft 47.00 f.
Width: ft 45.44 f
Setback capacity: Mt/lbs 450 kips
Simultaneous setback + hook load capacity: Mt/lbs 450 kips
Rotary beam capacity (total): Kips / mt

Clear height below rotary table beams (to main deck): ft

B.1.6 Weather Proofing


Rig floor windbreaks: yes/no NO
Derrickman windbreaks: yes/no NO
Around process pits: yes/no

B.1.7 Derrick TV Camera System


Camera located at: stabbing board &monkey board
Make/type: EAE L TD
Zoom/Pan/Tilt-function: yes/no yes
Monitor located at: dog house
Camera Explosion proof yes/no yes
Monitor Explosion proof yes/no yes
B.1.8 Mechanical Mouse Hole yes/no ??????????????
B.2 DRAWWORKS AND ASSOCIATED EQUIPMENT
B.2.1 Drawworks
Make/type: NATIONAL 1320 UE
Motors make/type: GE 752 DC
Quantity: no. 2
Rated input power: hp 2000 hp
Rated Capacity with 5” D/P ft 20000 f
Safety device crown- o- matic
Drum size (diameter x length): in x in 1-3/8 inch * 30 inch
Drum type (grooved/smooth) grooved
For drill line size: in 1-3/8 inch
Brake type (disc/drum) Brake band?
Maximum line pull 12 lines: Kips / mt 940 kips
Maximum line pull 10 lines: Kips / mt 805 kips
Maximum line pull 8 lines: Kips / mt 660 kips
Makeup cathead type: national B1
Breakout cathead type: national B1
Crown block safety devices: Yes/no Crown -O - Matic????????
Make/type: national model-TCB-A crown-o-matic
Independent fresh water cooling system for drawworks
yes/no
and electric brake: yes
Automatic driller: yes/no no??????????
Engines Explosion proof yes/no yes-spark arristor
B.2.2 Auxiliary Brake
Make: baylor
Model: elmago 7040 series
Independent back-up system type: baylor switchover unit model #56380

B.2.3 Sandline
Make:
Length capacity: ft
Line size/type:
Breaking strength: st
Safe working load: st

B.2.4 Slickline Unit


Make/model: Mathey Model 18- ILM
Wire length (nominal): ft 16000
Wire size: in 0.092 inch
Breaking strength: lbs
Safe working load: lbs
Depth counter: yes/no yes
Pull indicator: lbs. N/A

B.3 DERRICK HOISTING EQUIPMENT


B.3.1 Crown Block
Make/type: continental Emsco RA-60
Rated capacity: st 583 tons
No. of sheaves: no. 7
Sheave diameter: in 60 inch
Sheave grooved for line size: in 1 3/8 inch

B.3.2 Traveling Block


Make/type: national type 660 g 500 hook/block
Rated capacity: st 500 tons
No. of sheaves: no. 7
Sheave diameter: in 60 inch
Sheave grooved for line size: in
B.3.3 Hook
Make/type: N/A
Rated capacity: mt N/A
Complete with spring assembly/hook
Locking device: yes/no
B.3.4 Swivel
Make/type: N/A
Rated capacity; st N/A
Test/working pressure: psi/psi
Gooseneck and washpipe minimum ID: in
Left hand pin connection type:
Access fitting for wireline entry on Top gooseneck: yes/no
B.3.5 Drilling Line
Diameter: in 1-3/8 inch
Construction: 6*19 EIPS IWRC
Length (original): ft 5000 f?????/7500f
Drilling line reel: yes
Drum cover: yes/no yes
Drilling line drum power driven: yes/no yes
Spare drilling line: yes/no yes
Location (rig, shore, etc.) yes/no shorebase yard
Roller guides: yes/no no???????????
B.3.6 Dead Line Anchor
Make/type: National Model EB
Weight sensor: yes/no yes
Deadline dampener Yes/no yes
B.3.7 Block Guidance System
Make EMSCO
B.4 ROTATING SYSTEM
B.4.1 Rotating Table
Make/type: National C-375
Maximum opening: in 37 -1/2
Rated capacity: st 650 ton
Two speed gearbox: yes/no yes
Emergency chain drive: yes/no
Driven by an independent electric motor: yes/no yes
Electric motor make/type: GE 752 DC
Output power: hp 1000 hp
Maximum continuous torque: ft/lbs
Drip pan/mud collection system: yes/no
B.4.2 Master Bushings
Make/type: varco Mp CH Split hinged
Insert bowls: 20" ,13-3/8" , 9-5/8" ,7"

B.4.3 Kelly Bushing


Make/type: N/A
Lock down assembly: yes/no N/A

B.4.4 Top Drive


Make: VARCO TDS-4S
Type : electric
Rated capacity: st 650 tons
Test/working pressure: psi/psi 5000 psi
Output power: hp 1100 psi
Maximum continuous torque: ft-lbs 45500 f-lb
Two-speed gear box yes/no yes
Maximum rotary speed: rpm 205 rpm
Remote operated kelly cock: yes/no yes
Cooling system type: air
Upper inside BOP (see also D.1.15)
Kelly Cock Working pressure: Psi 10000 psi
Quantity: no. 2
Make/type: Varco ( dual actuator type )
Working pressure: psi 5000 psi
Max. OD body: in 9"
Max. ID body: in 3 3/4 "
Connection type (box): 7- 5/8 " regular box
Connection type (pin): 7 - 5/8 " regular pin
Top Drive Engines Explosion proof yes/no
B.4.4.1 Top Drive Makeup / Breakout System
Make/type: Varco
Model: PH 85
Max. makeup torque: ft/lbs 90000f-lb
Max. break out torque: ft/lbs 90000f-lb
Raised backup system: yes/no NO?????????
C. POWER SUPPLY SYSTEMS
C.1 RIG POWER PLANT
C.1.1 Diesel Engines
Quantity: no. 4
Make/type: caterpillar 3516 A
Maximum continuous power: hp 6460 hp
At rotation speed of: rpm 1200 rpm
Equipped with spark arrestors: yes/no ??????
Mufflers installed: yes/no ???????
Total fuel consumption, drilling (avg): bbl/day ????????
C.1.2 DC – Generator
Quantity: no. none
Make/type:
Continuous power: kw
At rotation speed of: rpm
Output volts: volts
C.1.3 AC – Generator
Quantity: no. 4
Make/type: caterpillar SR - 4
Continuous power: kw 2068 A/ generator
At rotation speed of: rpm 1200 rpm
Output volts: volts 600 v

C.1.4 SCR System or equivalent sysytem


Number of SCR: no. 5
Make/type: HILL GRAHAM
Maximum continuous power (total): kw 1800 amps each
Output volts: volts 0-750 V DC
Easy torque or equivelent Yes/No
Generator and SCR switches shall be equipped with
Yes/No
lock out and tag out system NO???????????/ yes
C.1.5 Transformer System
Quantity: no. 2
Make/type: GE
Continuous power (each): kva 1000 Kva
Output volts: volts 480 v
Frequency: hz 60 hz

Quantity: no.
Make/type:
Continuous power (each): kva
Output volts: volts
Frequency: hz
If main power generation systems have "rig save" valves
fitted, these should operate on the particular engine and
Yes/No
NOT cause the shutdown and lockout of any other
engines.
C.1.6 Emergency Shutdown
OIM OFFICE , SCR , RIG FLOOR
Emergency shutdown switches for the complete power
system (AC & DC),

Located at the following points: OIM OFFICE , SCR , RIG FLOOR


Independent Emergency Generator should be capable of
supplying power to run a centrifugal feed pump to
supply mud and/or water to the cement unit for hole
circulation ensure that cement unit can be started and
run if only emergency power is availableCONTRACTOR
to detail all functions provided by emergency generator
as presently connected. (BOP air )
YES
C.1.7 Compressed Air Systems
All air to be used for the “P” tanks shall be dried to
prevent moisture ingress. This means air dryers must be
installed and functional.
Sufficient “emergency air” must be available to allow
cement jobs to be completed and to run the air-
powered BOP accumulator charge pumps. Include the
drive mechanism used to power the emergency
compressor.
Air compressors - Cold Start:
Quantity: no. 1
Make: ???
Model: ???
Rated capacity: ft3/min ???
Working pressure: psi ???
Prime mover (electric/diesel): electrical
Continuous power: hp ???

Air compressors - Medium Pressure (rig air):


Quantity: no. 2
Make: Quincy
Model: QSI - 500
Rated capacity: M3 /hr 500 f3/min
Working pressure: psi 150 psi??????
Prime mover (electric/diesel): Electrical????
Continuous power: hp

Quantity: no.
Make:
Model:
Rated capacity: ft3/min
Working pressure: psi
Prime mover (electric/diesel):
Continuous power: hp

Air dryers:
Quantity: no. 1
Make: Ingersoll Rand DE stroke 18
Rated capacity: ft3/min
C.1.8 Air Receivers 3
Volume (total): ft3 151 f3
Pressure: psi 135 psi
Location:
C.2 EMERGENCY GENERATOR
C.2.1 Engine
Quantity: no. 1
Make/type: CAT 353 D???/ CAT 399
Maximum output: kW 250 kw
At rotation speed: rpm 1200 rpm
Automatic starting: yes/no yes
Starting methods (air, hydraulic,, battery): air, BATTERY
Max. angle of operation: degrees N/A

C.2.2 AC - Generator
Quantity: no. 1
Make/type: KATO
Maximum output: kVA 300 KW
At rotation speed: rpm 1200 rpm
Output volts: volts 480 v
Capable of back-feeding power to yes
main bus: yes/no
D. DRILLSTRING EQUIPMENT

Documentary evidence of NDT inspection is to be


provided for all down hole equipment under Section G,
prior to the COMMENCEMENT DATE. All tubulars shall
be hard-banded with layered wear-resistant alloys that
conform to the BP Hardbanding Specifications DCB/44
and 45/95. The only acceptable alloys brands are
Armacor and Arnco 200XT. Further information can be
provided upon request.
YES?????/ No hardbanding
D.1 TUBULARS
D.1.1 Kelly’s
Quantity: no.
Nominal size OD: in
Shape type (hexagonal, square, triangular):
Total / working length: ft / ft
Connection type:
D.1.2 Kelly/TDS Saver Subs
Quantity: no.
Nominalsize: in 6 5/8 " & 5" OD
Connection type: 4 1/2 " IF & 3 1/2 " IF
Protector: YES
D.1.3 Drill Pipe
Drill pipe OD: in 4 - 1/2 "
Grade: G-105
Total length: ft 6000 f/???
Range:
Weight: lbs/ft 19.5 lbs/f
Internally plastic coated: yes/no yes
Tool joint OD/ID: in/in
Tool joint pin length (original): in
Tapered shoulder tool joints (box/pins): deg./deg. 18
Connection type: 4-1/2 " IF
Hard facing:
API classification:
Thread protectors: yes/no
Sour service yes/no
Inspection standard

Drill pipe OD: in 3-1/2 "


Grade: G-105
Total length: ft 12000 f/ 400 joints????
Range:
Weight: lbs/ft 15.5 lbs/f…/ 13.3lbs/f???
Internally plastic coated: yes/no yes
Tool joint OD/ID: in/in
Tool joint pin length (original): in
Tapered shoulder tool joints (box/pins): deg./deg. 18
Connection type: 3-1/2" IF
Hard facing:
API classification: premium
Thread protectors: yes/no
Sour service yes/no
Inspection standard
D.1.4 Drill Pipe Pup Joints
Pipe OD in 5"
Tool joint OD/ID: in/in
Grade: G-105
Connection type: NC50
Internally plastic coated: yes/no YES
API Classification: RP7G
Thread protectors: yes/no YES
Quantity X Length: No X ft ???
Quantity X Length: No X ft yes???
Quantity X Length: No X ft yes???
Quantity X Length: No X ft yes???

Pipe OD in 3 1/2"
Tool joint OD/ID: in/in 5/2-1/4
Grade: S-135
Weight: lbs/ft
Connection type: 3-1/2 IF
Internally plastic coated: yes/no YES
API Classification: RP7G
Thread protectors: yes/no YES
Quantity X Length: No X ft ???
Quantity X Length: No X ft yes???
Quantity X Length: No X ft yes???
Quantity X Length: No X ft yes???

Pipe OD in
Tool joint OD/ID: in/in
Grade:
Weight: lbs/ft
Connection type:
Internally plastic coated: yes/no
API Classification:
Thread protectors: yes/no
Quantity X Length: No X ft
Quantity X Length: No X ft
Quantity X Length: No X ft
Quantity X Length: No X ft

D.1.5 Drill Pipe Casing Protectors


Initial stock: no. 150??????????
Make/type:
OD: in 7"
Installation tools (manual/hydraulic/none): manual

D.1.6 Heavy Wate Drill Pipe


Nominal size OD: in yes
Weight: lbs/ft yes
Quantity: no. 15 jts
Range: yes
Tool joint OD / ID: in/in yes
Type of hardfacing: yes
Internally plastic coated: yes/no yes
Connection type: yes
Thread protectors: yes/no yes

Nominal size OD: in 5"


Weight: lbs/ft 50 lbs/f
Quantity: no. 50 jts
Range: 2
Tool joint OD / ID: in/in yes
Type of hardfacing: yes
Internally plastic coated: yes/no yes
Connection type: yes
Thread protectors: yes/no yes

D.1.7 Drill Collars


OD body: in yes??????????????
ID body: in yes
Quantity: no. 9 jts
Nominal length of each joint: ft yes
Drill collar body (slick/spiral): yes
Recess for “zip” elevator: yes/no yes
Recess for slips: yes/no yes
Stress relief pin groove: yes/no yes
Boreback on box: yes/no no
Connection type: 6 5/8 REG
Number of lifting subs for 9 1/2” DC no. ??????????

OD body: in 8 1/4"
ID body: in 2 13/16 "
Quantity: no. 18 JTS
Nominal length of each joint: ft YES
Drill collar body (slick/spiral): YES
Recess for “zip” elevator: yes/no YES
Recess for slips: yes/no YES
Stress relief pin groove: yes/no YES
Boreback on box: yes/no NO
Connection type: YES
Number of lifting subs for 8 ” DC ??????????

OD body: in YES
ID body: in YES
Quantity: no. 18 jts
Nominal length of each joint: ft YES
Drill collar body (slick/spiral): YES
Recess for “zip” elevator: yes/no YES
Recess for slips: yes/no YES
Stress relief pin groove: yes/no YES
Boreback on box: yes/no no
Connection type: YES
Number of lifting subs for 6 1/2 ” DC

OD body: in yes
ID body: in yes
Quantity: no. 18 jts
Nominal length of each joint: ft yes
Drill collar body (slick/spiral): yes
Recess for “zip” elevator: yes/no yes
Recess for slips: yes/no yes
Stress relief pin groove: yes/no yes
Boreback on box: yes/no no
Connection type: yes
Number of lifting subs for 4 3/4 ” DC

D1.8 Short Drill Collars


Quantity: no. 1
OD body: in 9 1/2"-8" -6 1/2"
ID body: in 3" - 2 13/16" - 2 25/32 "
Nominal length of each joint: ft 10
Stress relief pin groove: yes/no yes
Boreback on box: yes/no yes
Connection type:
D.1.9 Non-Magnetic Drill Collars
Quantity: no.
OD body: in
ID body: in
Nominal length of each joint: ft
Drill collar body (slick/spiral):
Recess for “zip” elevator: yes/no
Recess for slips: yes/no
Stress relief pin groove: yes/no
Boreback on box: yes/no
Connection type:
D.1.10 Core Barrels

Quantity: no.
Make:
Model:
Size OD x ID: in x in
Length: ft
Top connection type:
Spiral stabilizing ribs: yes/no
Subs and handling tools: yes/no

D.1.11 Stabilizers
Hole size: in
Quantity: no.
Make:
OD blades: in
Type blades (straight/spiral/welded/integral/sleeve):
Type of blade hardfacing:
OD body or fishing neck: in
ID body: in
Connection type:
Float valve receptacle: yes/no

Hole size: in
Quantity: no.
Make:
OD blades: in
Type blades (straight/spiral/welded/integral/sleeve):
Type of blade hardfacing:
OD body or fishing neck: in
ID body: in
Connection type:
Float valve receptacle: yes/no

Hole size: in
Quantity: no.
Make:
OD blades: in
Type blades (straight/spiral/welded/integral/sleeve):
Type of blade hardfacing:
OD body or fishing neck: in
ID body: in
Connection type:
Float valve receptacle: yes/no

Hole size: in
Quantity: no.
Make:
OD body: in
ID body: in
OD fishing neck: in
Cutters supplied sets: no.
Cutters, type:
Connection, type:
D.1.13 Shock Absorbers
Quantity: no.
Make/type:
OD body: in
ID body: in
OD fishing neck: in
Connection type:
D.1.14 Drilling Jars
Quantity: no.
Make:
Type (mechanical/hydraulic; up/down):
OD body: in
Min. ID body: in
OD fishing neck: in
Stroke: in
Connection type:
D.1.15 Inside BOP Valve (see also B.4.4)
Quantity: no. yes
Make / Type: cameron
OD: in yes
Min. ID: in yes
Connection type: yes
Working pressure: psi yes

Quantity: no. yes


Make / Type: cameron
OD: in yes
Min. ID: in yes
Connection type: yes
Working pressure: psi 10 000 psi
D.1.16 Fast Shut-Off Coupling
Make/type:
Quantity: no.
Size tool joint to fit:
D.1.17 Circulation Head
Quantity: no. yes
Make/type: pin * 2" WECO
For each
Bottom connection type:
string yes
Top connection type: 2” weco yes
Wireline stripper: yes/no no
Working pressure: psi yes
D.1.18 Kelly Cocks
Upper:
Quantity: no.
Make/type:
Working pressure: psi
Max. OD body: in
Min. ID body: in
Connection type:

Lower:
Quantity: no.
Make/type:
Working pressure: psi
Max. OD body: in
Min. ID body: in
Connection type:
Used as full open safety valve: yes/no
D.1.19 Circulation Subs
Quantity: no. yes
Make/type:
OD body: in yes
Ball size: in
Dressing kits: no.
Connection type:
D.1.20 Cup Type Testers
Quantity: no. yes
Make: cameron or equivelant
Size: in yes
test cup for casing weight: 47 lb/ft yes
test cup for casing weight: 53.5 lb/ft yes
test cup for casing weight: lb/ft
Connection type: yes

Quantity: no. yes


Make: cameron or eqivelant
Size: in yes
test cup for casing weight: 68 lb/ft yes
test cup for casing weight: 72 Lb/ft yes
test cup for casing weight: Lb/ft
Connection type: yes
Quantity: no. yes
Make: cameron or eqivelant
Size: in yes
test cup for casing weight: 35 lb/ft yes
test cup for casing weight: 28 Lb/ft yes
test cup for casing weight: Lb/ft
Connection type: yes
D.1.21 Plug Type Testers
Quantity: no.
Make:
Size test plugs: in
Connection type:
D.1.22 Drop-In Valves
Quantity: no.
For nom. OD drillpipe: in
Make/type:
Max. OD of dart.: in
D.1.23 Float Valves
Quantity of float valves: yes?????
Make / Type: baker
OD size: in for 9 1/2" DC, 8" DC ,6 1/2" DC, 4 3/4" DC
Quantity of float Subs:
ID size: in N/A
Top connection type:
Bottom connection type:
Bored : yes/no
Float size: in
D.1.24 Crossover Subs Need to list them, GTP A/D can do this job
Cross overs to suit all CONTRACTOR supplied, drill pipe,
drill collars and down hole tools must be provided.
yes
Quantity: no. yes
OD size (max/min): in/in yes
ID size: in yes
Top connection size: yes
Type (pin/box): yes
Bottom connection size: yes
Type (pin/box): yes

Quantity: no. YES


OD size (max/min): in/in YES
ID size: in YES
Top connection size: YES
Type (pin/box): YES
Bottom connection size: YES
Type (pin/box): YES

Quantity: no. YES


OD size (max/min): in YES
Id Size in YES
Top connection size: YES
Type (pin/box): YES
Bottom connection size: YES
Type (pin/box): YES

Quantity: no. YES


OD size (max/min): in YES
Id Size in YES
Top connection size: YES
Type (pin/box): YES
Bottom connection size: YES
Type (pin/box): YES
Quantity: no. YES
OD size (max/min): in YES
Id Size in YES
Top connection size: YES
Type (pin/box): YES
Bottom connection size: YES
Type (pin/box): YES

Quantity: no.2 YES


OD size (max/min): in YES
Id Size in YES
Top connection size: YES
Type (pin/box): YES
Bottom connection size: YES
Type (pin/box): YES

Quantity: no. YES


OD size (max/min): in YES
Id Size in YES
Top connection size: YES
Type (pin/box): YES
Bottom connection size: YES
Type (pin/box): YES

Quantity: no. YES


OD size (max/min): in YES
Id Size in YES
Top connection size: YES
Type (pin/box): YES
Bottom connection size: YES
Type (pin/box): YES

Quantity: no.
OD size (max/min): in
Id Size in
Top connection size:
Type (pin/box):
Bottom connection size:
Type (pin/box):

Quantity: no.
OD size (max/min): in
Id Size in
Top connection size:
Type (pin/box):
Bottom connection size:
Type (pin/box):
D.1.25 Drilling Bumper Subs

Quantity: no.
Make:
OD: in
Stroke: in
Connection type:

D.1.26 Hole Openers (not required)


Quantity: no.
Make:
OD: in
Connection type:

D.1.27 Bit Subs


Quantity: no. YES???
Make/type:
OD min/OD max: in/in YES
Connection type: YES

D.2 HANDLING TOOLS


D.2.1 Drill Pipe Elevators
Size: in YES
Quantity: no. YES
Make: BJ
Model: GG
Rated capacity: st YES?????????????????
Size: in YES
Quantity: no. YES
Make: BJ
Model: GG
Rated capacity: st YES?????????????????

D.2.2 Drill Collar Elevators use 5" DP elevators with lifing subs for DC S

Size: in YES
Quantity: no. YES
Make:
Model: YES
Rated capacity: st YES

Size: in YES
Quantity: no. YES
Make:
Model: YES
Rated capacity: st YES

Size: in YES
Quantity: no. YES
Make:
Model: YES
Rated capacity: st YES

Size: in YES
Quantity: no. YES
Make:
Model: YES
Rated capacity: st YES
D.2.3 Tubing/Casing Elevators
Size: in YES
Quantity: no. YES
Make: BJ
Model: GG
Rated capacity: st YES?????????????????

Size: in YES
Quantity: no. YES
Make: BJ
Model: GG
Rated capacity: st YES??????????

Size: in N/A
Quantity: no.
Make:
Model:
Rated capacity: st

Size: in N/A
Quantity: no.
Make:
Model:
Rated capacity: st
D.2.4 Drill Pipe Hand Slips
Size: in YES
Quantity: no. YES
Make/type: VARCO SDXL
Size: in YES
Quantity: no. YES
Make/type: VARCO SDXL

Size: in
Quantity: no.
Make/type:
Size: in
Quantity: no.
Make/type:

D.2.5 Semi-Automatic DP Slips/ D/P Automatic slips


N/A
Size range (largest/smallest): in/in
Quantity: no.
Make/type:
D.2.6 Drill Collar Slips
Size: in YES
Quantity: no. YES
Make/type: VARCO DCS-1
Size: in YES
Quantity: no. YES
Make/type: VARCO DCS-1

Size: in YES
Quantity: no. YES
Make/type: VARCO DCS-1

Size: in YES
Quantity: no. YES
Make/type: VARCO DCS-1
D.2.7 Drill Collar Safety Clamps
To be provided for all sizes of d/p and d/c
Quantity: no. YES
Range: in/in YES

Quantity: no.
Range: in/in
D.2.8 Tubing/ csg Slips N/A
Size: in 2 3/8" - 2 7/8"????????????
Quantity: no.
Make/type:

D.2.9 Tubing Spider N/A


Slip size (max/min): in/in
Quantity: no.
Make:
Adapter Plate:

D.2.10 Drill Collar Lifting Subs


Quantity: no. YES
For DC OD: in YES
Connection Type: 7 5/8" REG

Quantity: no. YES


For DC OD: in YES
Connection Type: 6 5/8" REG

Quantity: no. YES


For DC OD: in YES
Connection Type: 4 1/2" IF

Quantity: no. YES


For DC OD: in YES
Connection Type: 3 1/2" IF
D.2.11 DC Lifting Plugs
Quantity: no. YES
For DC OD: in YES
Connection Type: 7 5/8" REG

Quantity: no. YES


For DC OD: in YES
Connection Type: 6 5/8" REG

Quantity: no. YES


For DC OD: in YES
Connection Type: 4 1/2" IF

Quantity: no. YES


For DC OD: in YES
Connection Type: 3 1/2" IF
D.2.12 Bit Breakers
Quantity: no. YES
For bit size: in YES

Quantity: no. YES


For bit size: in YES

Quantity: no. YES


For bit size: in YES

Quantity: no. YES


For bit size: in YES

Quantity: no. YES


For bit size: in YES

Quantity: no. YES


For bit size: in YES

Quantity: no.
For bit size: in

Quantity: no.
For bit size: in

D.2.13 Elevator Links


Quantity of sets: no. YES
Make/type: VARCO / WELDLESS
Size: in 3 5/8 "
Length: in YES
Rated capacity: st YES

Quantity of sets: no. YES


Make/type: VARCO / WELDLESS
Size: in 3 3/4"
Length: in 139"
Rated capacity: st 500

Quantity of sets: no. YES


Make/type: VARCO / WELDLESS
Size: in YES
Length: in YES
Rated capacity: st YES

Quantity of sets: no. YES


Make/type: VARCO / WELDLESS
Size: in YES
Length: in YES
Rated capacity: st YES

D.2.14 Kelly Spinner


Make/type:

D.2.15 Drill pipe Spinner


Make/type: Spinmaster/Hawk 550 series
Size (max/min): in/in 2 7/8 "- 5 1/2"

D.2.16 Mud Saver Bucket


Make: GOTCO
Size: in 5 & 3 1/2"
D.2.17 Eazy Torque
Make/type: ?????????
Maximum line pull: lbs ????????
D.2.18 Rotary Rig Tongs
Rotary tong to handle all drill pipe , drill collar sizes
Quantity (sets): no. YES
Make/type: HT 100
Size range (max OD/min OD): in/in 4 -13 3/8"
Torque rating: ft-lbs 100 000 f lbs
Quantity (sets): no. YES
Make/type: HT 65
Size range (max OD/min OD): in/in 4 -13 3/8"
Torque rating: ft-lbs 65 000 f lbs

D.2.19 Tubing Tongs (manual)


Quantity (sets): no.
Make/type:
Size range (max OD/min OD): in/in
Torque rating: ft/lbs

D.2.20 Tubing Tong Power (not required)


Quantity: no.
Make/type:
Size range (max OD/min OD): in/in
Max output torque: ft/lbs
Torque indicator: yes/no
Back-up arm: yes/no

D.2.21 Iron Roughneck or equivelant hydrouclic


power tong
Make/type: no
9.5 in/ 2-
Size range (max OD/min OD):
7/8 in
80000
Max. makeup torque
ft/lbs
80000
Max. breakout torque
ft/lbs
Casing Capability Yes / no
Tubing Capability Yes / no
Liner Capability Yes / no
Bit Capability Yes / no
Torque Turn Capability Yes / no
D.2.22 High Tourque wrench
Capable of making a back out BOP nut tubbing
Yes / no
head spool and X-tree yes????????????????? What is this?

D.3 FISHING EQUIPMENT


list ones onboard, prepare inventory
D.3.1 Overshots
Quantity: no.
Make/type:
Overshot OD: in
To catch size: in
To catch size: in
To catch size: in
Overshot guide OD: in
Extension sub length: in
Lipped guide (oversize, regular):
Grapples (spiral, basket, both):
Pack offs: yes/no
Top subs connection type:

D.3.2 Hydraulic Fishing Jar


Quantity: no.
Make/type:
OD body: in
Min. ID: in
Stroke: in
Connection type:
Repair kit: yes/no
D.3.3 Jar Intensifier
Quantity: no.
Make/type:
OD body: in
Min. ID: in
Connection type:
Repair kit: yes/no

D.3.4 Surface Jar


Quantity: no.
Make/type:
OD body: in
Stroke: in
Connection type:
Repair kit: yes/no

D.3.5 Fishing Bumper Subs


Quantity: no.
Make/type:
OD body: in
Min. ID: in
Stroke: in
Connection type:

D.3.6 Safety Joints no.


Make/type:
OD body: in
Min. ID: in
Connection type:
D.3.7 Junk Baskets (Reverse Circulation)

Quantity: no.
Make/type:
For hole size: in
OD body: in
Connection type:
Inside magnet available: yes/no
Mill shoes type (A, B, C):

D.3.8 Junk Subs


Quantity: no.
Make/type:
For hole size: in
OD body: in
Connection type:

D.3.9 Flat Bottom Junk Mill


Quantity: no.
Make/type:
OD flat mill: in
Connection type:

D.3.10 Magnet Fishing Tools


Quantity: no.
Make/type:
OD body: in
Connection type:
Ditch Magnet In Flow Channel Yes/No

D.3.11 Taper Taps (Not Required )


Quantity: no.
Make:
Tap OD (max/min): in/in
OD body: in
Length overall: ft
Connection type:

D.3.12 Die Collars (Not Required )


Quantity: no.
Make/type:
OD (Max/Min): in/in
OD body: in
Length: ft
Connection type:
E. WELL CONTROL

All equipment shall be API 513 -16 BP ETP OEM


(Original Equipment Manfacture) , in addition to all Yes/no
appropriate components H2S rated (attached)
yes?????? Sure H2S rated and as per API???
E.1 DIVERTER
Diverter to fit on CONTRACTOR rotary table and capable
of accepting and controlling anticipated shallow gas
kicks while maintaining near “0” psi back pressure ,
flange connection throughout . ?????????????????????????
Overshots, packers and seals for 30” & 24” are required
as a minimum .
Diverter system to have two (2) 12 hydraulic remote
operated full opening valves with starboard and port 12”
diversion lines that conform to API RP-64
An accumulator capable of closing , opening and closing
while maintaining manfactures recommended operating
pressure without recharge.
Diverter to be nippled upon 30” & 24” casing
Fixed: yes/no
Make/type:
Maximum bore: in
ID of insert packer: in
Working pressure: psi

Annular: Yes/no
Make/type:
Maximum bore: in
ID of insert packer: in
Working pressure: psi
Bottom connection
Size
Working pressure:
Gasket type

Annular: yes
Make/type:
Maximum bore: in
ID of insert packer: in
Working pressure: psi
Bottom connection yes/no
Size in
Working pressure: psi
Gasket type no

Rams
Make/type:
number
Ram Packer type
Ram Packer type
Maximum bore size :
Working pressure:

Bottom connection yes/no


Size in
Working pressure: psi
Gasket type no

Number of Diverter outlets: no.


Outlet OD (nominal): in

E.1.1 Diverter Flow Lines


Quantity: no. yes
Nominal size of flow lines: in yes
Running from Diverter to: port/Stbd
Valve make/type: yes
Quantity: no. yes
Size: in yes
Valve operator (air/hydraulic): yes?????????????????/

Quantity: no.
Nominal size of flow lines: in
Running from Diverter to:
Valve make/type:
Quantity: no.
Size: in
Valve operator (air/hydraulic):

Quantity: no.
Nominal size of flow lines: in
Running from Diverter to:
Valve make/type:
Quantity: no.
Size: in
Valve operator (air/hydraulic):

Quantity: no.
Nominal size of flow lines: in
Running from Diverter to:
Valve make/type:
Quantity: no.
Size: in
Valve operator (air/hydraulic):

E.1.2 Diverter Control Panel


Primary make/type: Koomey
Location: drill floor/ Port af below cantilever????

Remote make/type: koomey


Location: muster deck/ rig floor???????
E.2 HIGH PRESSURE BLOWOUT PREVENTERS
All flow wetted and pressure containing components
Yes/ no
shall be H2S rated ( H2S Trim ). yes
All nesessary equipment; including drilling spool , risers ,
valves, lines required to rig the BOPs and all spare parts Yes/no
to be OEM. yes
The ram preventer body section(s) of the BOP stack
yes
should consist of one (1) double ram body and one (1) Yes/no
single ram body.
CONTRACTOR is responsible for all rubber goods under yes
Yes/no
normal wear and tear situations.

All rams and annular preventor rubber elemnts are


to be fitted with high temperature, SOBM resistant
elastomer seals including all ram extrudable seals
and ram rod seals. Seal stop to be certified to a Yes/no
minimum of 300 deg F including testing for
temperature cycling. Each Rams shall have a
functional locking devices fitted.
??????????????/
BOP must be equipped with proper bonnets and
boosters to allow shearing and sealing of 5” 19.5 PPF DP
Yes/no
S-135 with 5000 psi wellbore surface pressure. A
documented test of this is required. yes

E.2.1 Ram Type Preventers


Quantity: no yes
Make/model: cameron/ type U
Type: (single/double/triple): yes
Size: in yes
Working pressure: psi yes
Ram locks: yes/no yes
Type (manual/hydraulic): yes
H2S service: yes/no yes
Side outlets: no. yes
Size: in yes
WP: psi yes
Bottom connection: yes
Top connection: yes
Shear ram boosters: yes/no yes
E.2.2 Available Rams (installed & spare)
no./type/i
Quantity/type/size yes
n
no./type/i
Quantity/type/size
n yes
no./type/i
Quantity/type/size
n yes
no./type/i
Quantity/type/size yes
n
no./type/i
Quantity/type/size
n yes
no./type/i
Quantity/type/size
n yes
no./type/i
Quantity/type/size
n yes
no./type/i
Quantity/type/size
n yes
E.2.3 BOP Ram Configuration (normal)
Upper: yes???????????//
Middle Upper: yes???????????//
Middle Lower: yes???????????//
Lower: yes???????????//
yes
E.2.4 Annular Preventer

The annular and packer shall be capable of closing


and sealing to the full pressure rating for 13 3/8”
casing and pass API close-on-open-hole test. The Yes/no
same packer shall also be able to seal on 2 7/8”
drill pipe and hold full working pressure.
??????????????????
Quantity: yes?????????????
Make/type: no. HYDRIL/ MSP
Size: yes?????????????
Working pressure: in yes?????????????
Bottom Connection: psi Flanged RX 73
Top Connection: BOLT
Lifting Frame

Quantity: YES
Make/type: no. Shaffer
Size: yes
Working pressure: in yes
Bottom Connection: psi flanged
Top Connection: bolts
Lifting Frame pad eyes

Quantity:
Make/type:
Size:
Working pressure: no.
Bottom Connection:
Top Connection: in
Lifting Frame psi
E. 2.5 Kill Line Valves

All flow wetted and pressure containing


components shall be H2S rated ( H2S Trim ) and Yes/no
surface temperature @ ºF. yes
A drawing indicating the placement of the Kill and
yes
Choke line outlet positions on the BOP stack is to be Yes/no
included with the tender documents.
The stack is to have a minimum of three (3) inlet/outlets,
one must be positioned below the lowermost sets of
rams. Yes/no yes
Both Kill and Choke lines are to be rated to 10,000 psi
working pressure (minimum).
Quantity: no. yes??
Make/type: EEC
Size: in 3 1/16"
Working pressure: psi yes??
Gasket type yes??
Hydraulic/manual/non-return: yes??

Quantity: no YES
Make/type: EEC
Size: in 3 1/16"
Working pressure: psi YES
Gasket type in YES
Hydraulic/manual/non-return: YES

E.2.6 Choke Line Valves


YES
Quantity: no. YES
Make/type: EEC
Size: in 3 1/16"
Working pressure: psi YES
Gasket type
Hydraulic/manual: Hydraulic

Quantity: No. yes


Make/type: EEC
Size: In 3 1/16"
Working pressure: Psi yes
Gasket type yes
Hydraulic/manual: yes

E.3 LOW PRESSURE BLOWOUT PREVENTERS


All appropriate components H2S rated: yes/no

E.3.1 Ram Type Preventers ??????????????????/


Quantity: no.
Make/model:
Type (single/double/triple):
Size: in
Working pressure: psi
Ram locks:
Type (manual/hydraulic):
H2S service:
Side outlets: no.
Size:
WP:
Bottom connection: in
Top connection: psi
Shear ram boosters: yes/no

Quantity: yes/no
Make/model:
Type (single/double/triple):
Size: in
Working pressure: psi
Ram locks: yes/no
Type (manual/hydraulic):
H2S service:
Side outlets:
Size:
WP:
Bottom connection:
Top connection:
Shear ram boosters:

E.3.2 Available Rams (installed & spare)


no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
E.3.3 BOP Ram Configuration (normal)
Upper:
Upper middle:
Middle:
Middle lower:
Lower:

E.3.4 Annular Preventer


Quantity: no.
Make/type:
Size: in
Working pressure: psi
Bottom connection:
Top connection:
H2S service: yes/no
Lifting Frame psi

E.3.5 Kill Line Valves


Quantity: no.
Make/type:
Size: in
Working pressure: psi
Gasket type:
Hydraulic/manual/non-return:

Quantity: no.
Make/type:
Size: in
Working pressure: psi
Gasket type:
Hydraulic/manual/non-return:

Quantity:
Make/type:
Size: no.
Working pressure:
Gasket type: in
Hydraulic/manual/non-return: psi

E.3.6 Choke Line Valves


Quantity: no.
Make/type:
Size: in
Working pressure: psi
Gasket type:
Hydraulic/manual:

Quantity:
Make/type:
Size: yes/no
Working pressure:
Gasket type:
Hydraulic/manual:
no.
E.4 OTHER BLOWOUT PREVENTERS
All appropriate components H2S rated in
psi
E.4.1 Ram Type Preventers
Quantity: yes/no
Make/model: no.
Type (single/double/triple): in
Size: psi
Working pressure
Ram locks:
Type (manual/hydraulic): yes/no
H2S service:
Side outlets:
Size:
WP:
Bottom connection:
Top connection:
Shear ram boosters:

E.4.2 Available Rams (installed & spare)


no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n
no./type/i
Quantity/type/size:
n

E.4.3 BOP Ram Configuration (normal)


Upper:
Upper middle:
Middle:
Middle lower:
Lower:

E.4.4 Choke Line Valves (not required)


Quantity: no
Make/type: no
Size:
Working pressure: no
Gasket type:
Hydraulic/manual:
E.4.5 Inside BOP (Drop in sub)
Drill string BOP equipment (Kelly, Gray valves and dart
subs) shall be provided by the CONTRACTOR to suit drill
yes/no
string components. Drill string BOP equipment must be
rated to 10000 psi WP. yes
For 5 “ drill string no yes
For 3 1/2” drill string no yes
E.4.6 Float Valve
For each size of bit sub. yes
One ported and one non-ported float valves. yes/no yes

E.4.7 Circulating Heads


Complete with swivel assembly No yes
Type in yes
For 5 “ drill string psi yes
Type
For 3 1/2” drill string yes
E.4.8 Drill Pipe safety valve “Full opening valves”

Full open safety valve ( FOSV ) rated to same


pressure as BOP (10K psi), shall provided by
CONTRACTOR and ready to install on rig floor at
Yes/no
all times. Cross-overs shall be available such that
the FOSV can be attached to any string of pipe run
in hole yes
Drill string size In yes
Quantites No yes
Connection in yes
Working pressure psi yes

Drill string size In yes


Quantites No yes
Connection in yes
Working pressure psi yes
E.4.9 Drill Pipe safety valve “Gray type valves”
Drill string size In yes
Quantites No yes
Connection in yes
Working pressure psi yes

Drill string size In yes


Quantites No yes
Connection in yes
Working pressure psi yes
E.5 BOP CONTROL SYSTEM
E.5.1 Accumulator Unit
Comply with API RP53 Yes/no yes?????????
Make/model: koomey 162-10STB
Quantity: No.
Location:
Fluid reservoir capacity: Gal 380 gallons
Stations: ??
Oil/water mix. rate: ???
Glycol reservoir capacity: Gal ???
Total accumulator capacity Gal ??
(w/o precharge): ???
System working pressure: Psi ???
Control manifold model: ??
Regulator type: ??
Total useful accumulator volume equals all preventer
opening and closing volumes: Yes/no ??
plus 50% percent additional volume: ??

E.5.2 Accumulator Hydraulic Pumps


Electric Driven: YES
Quantity: 1
No.
Make/model: TECO
Each driven by motor of power: hp 30 hp
Flow rate of each pump: gals/min 14.2 us gpm
At operating pressure: psi 3000
Operable of emergency generator: yes/no yes

Air Driven: No. 3?????


Quantity:
Make/model:
Flow rate of each pump: gals/min
At operating pressure: psi

E.5.3 Primary Control Panel


Control panel make/model: SHAFFER VARCO COMPANY(SPHERE SUPPLY)
Location: Driller cabin
Panel controls for the following functions:
All annular BOP’s: yes/no yes
All ram BOP’s: yes/no yes
Lock for ram BOP’s: yes/no no
Diverter system: yes/no yes
Kill and choke line valves: yes/no yes
Low accumulator pressure warning: yes/no yes
Low reservoir level warning: yes/no no
Low rig air pressure warning: yes/no yes
System pressure regulator: Yes/no no
Pressure regulator for annular: Yes/no no
Flowmeter: Yes/no no
Quantity of pressure gauges: No. 3
Other control functions:

E.5.4 Remote Control Panels


Make/model: SHAFFER VARCO COMPANY(SPHERE SUPPLY)
Location: toolpusher s office
Ability to operate main closing unit valves directly Yes/no YES
System routing (direct or through panel):
Remote control of - system pressure regulator: yes/no NO
Remote control of - annular pressure regulator: yes/no NO

Make/model:
Location:
Ability to operate main closing unit valves directly:
System routing (direct or through panel):
Remote control of - system pressure regulator: yes/no
Remote control of - annular pressure regulator: yes/no

E.6 CHOKE MANIFOLD


All appropriate components H2S rated yes/no yes
E.6.1 Choke Manifold
(for instrumentation, See H.3)

A standpipe pressure gauge and choke line


pressure gauge are to be located on the manifold
Yes/no
such that both are clearly visible from the
operating position of the manual choke.
yes
These oil filled gauges shall be fitted with quick
connect/disconnect fittings or be manifolded such
Yes/no
that individual gauges can be isolated or put on
line. Gauges to be of following ranges: yes
0- 500 psi Yes/no yes
0 - 1000 psi Yes/no yes
0 - 3000 psi Yes/no yes
0 - 5000 psi Yes/no yes
0 -10000 psi Yes/no yes
In addition, a remote choke line gauge and
standpipe pressure gauge are to be located on the Yes/no
remote choke panel. yes

A schematic of the choke manifold system showing


valves, sizes and pressure ratings must be
Yes/no
provided. Outlet/inlets to standpipe manifold,
degasser, cement unit etc., must be clearly shown.
yes
Nominal size: in yes
Minimum ID: in 2 1/16"
Maximum WP: psi yes

Quantity of fixed chokes: no. N/A


Make/model:
Size (ID): in

Quantity of adjustable chokes: no. 2


Make/model: cameron CH 2A
Size (ID): in yes

Quantity of remote operated hydraulic chokes: no. 1


Make/model: swaco H2L
Size (ID): in yes

Power choke remote control panel: yes/no yes


Make/model: swaco
Location: yes
Glycol injection: yes/no no
E.7 FLEXIBLE CHOKE & KILL LINES
(BOP to MANIFOLD)

Quantity: no. 2
Make/type: cooper state
ID: in yes
Working pressure: psi yes
H2S service: yes/no yes

E.8 FLEXIBLE BOP CONTROL HOSES


Quantity: no. 12
Make/type: coflex
ID: in 1"
Working pressure: psi yes
Fire resistant: yes/no yes

E.9 BOP TESTING EQUIPMENT


E.9.1 Hydraulic BOP Test Pump
Make/model: koomey / 2T10/0009
Type: dual air pump
Pressure rating: psi 10 k
Chart recorder: yes/no yes

E.9.2 BOP Test Stump


A BOP test stump shall be provided to allow the
BOP stack to be pressure tested to rated capacity Yes/no
offline before installation yes
Size: 13 5/8"
Size: 21 1/4"
Size:

E.10 BOP HANDLING


E.10.1 BOP Hoist System
Make/type:
Quantity of hoists: no. 4
Number of lift point on BOP: no. 2
System safe working load (max BOP wt): mt 35 ton
All Monorails, Monorail Trolleys and Hoists shall be
marked with identification number and safe work Yes/no
loads. yes
All Monorails shall be fitted with end stops. Yeslno yes

 Dropped object prevention system/ specifications. Yes/no


yes
E.10.2 Work Platforms
BOP work platform (adjustable/fixed/none): yes/no yes , fixed
Conductor pipe platform: Yes/no Texas deck????

E.10.3 Conductor Pipe Tensioning System


Make/type:
Tension capacity: lbs
Number of lift points: no.
Stroke: m
E.10.4 HIGH TORQUE WRENSH FOR M/U NUTS yes
Make/type: varco
SIZE fit for all wellhead & BOP nuts yes
TORQUE
F. MUD SYSTEM/BULK SYSTEM
F.1 HIGH PRESSURE MUD SYSTEM
System working pressure: psi yes
System test pressure: psi 10000 psi???????????

F.1.1 Mud Pumps


Quantity: no. yes , we intend to add another one if needed
Make: continental Emsco
Model: 1600 FB
Type: (Triplex/Duplex): TRIPLEX
Liner sizes available: in YES
Mud pump drive motors/pump: no. YES
Motor type: GE 752 R
Continuous power rating per motor: hp 800
Fluid end type: SOUTHWEST
Maximum working pressure: psi YES
Test pressure: psi 5000 PSI
Pump stroke counter type: proximity switch to martin decker
Supercharging pump: mission magnum
Driven by motor of power: hp 100 hp
Discharge/Suction line ID: in/in 6"/5"
Mud pump pulsation dampener type: hydrill
Electric is
Reset Relief Valve type:
perfered Retsco
Working flow rate per pump at 90% of max spm:
Liner size: in 6-1/2" ceramic
Pump speed (90% of max.): spm 120 spm
Pump pressure: psi
U.S.
Working flow rate:
gal/min 589gpm
Accessories yes

Quantity: no.
Make:
Model:
Type: (Triplex/Duplex):
Liner sizes available: in
Mud pump drive motors/pump: no.
Motor type:
Continuous power rating per motor: hp
Fluid end type:
Maximum working pressure: psi
Test pressure: psi
Pump stroke counter type:
Supercharging pump:
Driven by motor of power: hp
Discharge/Suction line ID: in/in
Mud pump pulsation dampener type:
Reset Relief Valve type:
Working flow rate per pump at 90% of max spm:
Liner size: in
Pump speed (90% of max.): spm
Pump pressure: psi
U.S.
Working flow rate:
gal/min
Accessories

F.1.2 Transfer Pumps/Mixing Pumps


Mixing / Transfer Pumps ????
Quantity: no. yes
Make/model: mission 14 "
Type/Size ???
Output Capacity: gpm ???
Drive motor type: seimens
Power output: hp 125 hp

Gel Tank Pumps


Quantity: no.
Make/model:
Type/size:
Output capacity: gpm
Drive motor type:
Power output: hp
F.1.3 Booster / Charging Pump
Quantity: one for each mud pump no. 1
Make/Mode:
Type/Size
Capacity (each): gals/min
Drive motor type: seimens
Power output: hp 75
F.1.4 Standpipe Manifold
Dual pipe , stand pipe system manifold with quick
connect strainer assembly (w/hammer unions ) in or just
upstream of the manifold YES
Quantity of standpipes: no. YES
Working pressure : psi
Standpipe/ID: in 3-1/2"
H-Type standpipe manifold: yes/no YES
Kill line outlet: yes/no
Fill-up line outlet: yes/no
Bleed-off line outlet: yes/no
F. 1.5 Rotary Hoses
Minimum OD of discharge line(s) to be 4" with a
working pressure of 5,000psi. A spare stand-pipe/rotary Yes/no
hose to be rigged up and available. YES
Quantity: no. YES
Make/type: GOODALL
ID x length: in x ft 3.5" * 80
Working pressure: psi 7500 PSI
Snubbing lines: yes/no YES
yes
F.1.6 Cementing Hose
Quantity: no.
Type (armor sheath/flexible steel pipe): 12
Length: ft steel chicksan
ID: in 2"
Working pressure: psi 10000

F.1.7 High Pressure Flexible Steel Pipe


Make/type:
Integral connections/fittings (non-threaded): No. 1 one rubber
ID: in yes
Working pressure: psi 10 k
Section length: ft 40 f
Quantity: no.
Section length: ft
Quantity: no.
Sweep swivels, make/type:
Nom. size ID: in
Suitable for H2S service: yes/no

F.2 LOW PRESSURE MUD SYSTEM


F.2.1 Mud Processing Tank
Shaker #1 tank, usable volume: bbl 50 bbl
Shaker #2 tank, usable volume: bbl 50 bbl
Agitated: yes/no no
Shaker #3 tank, usable volume: bbl 50 bbl
Agitated: yes/no no
Shaker #4 tank, usable volume: bbl 30 bbl
Agitated: yes/no no
Shaker #5 tank, usable volume: bbl N/A
Agitated: yes/no N/A
Centrifuge tank, usable volume: bbl 20 bbl
Agitated: yes/no no
Other tank, usable volume: bbl N/A
Agitated: yes/no N/A
Total usable capacity: bbl 200 BBL

F.2.2 Mud Tanks


Active Mud Tanks
1000 bbls minimum required (excluding solids control total capacity :1718 bbl
pits) with sufficient agitation to handle 18.0 ppg. active or reserve
Agitators to be minimum of 40 hp.
Reserve Mud Tanks
900 bbls minimum required (excluding solids control trip tank :32 bbl
pits) with sufficient agitation to handle 15.0 ppg. hole fill pump dedicated only to
Agitators to be minimum of 40 hp trip tank
Trip Tank mechanical level indicator on
rig floor
25 bbls minimum size.
Hole fill pump should be dedicated to the trip tank and
not to any other function.
Please indicate if this available otherwise.
Mechanical level indicator on rig floor
required.Incremental volume of trip tank to be less than
0.5bbls/inch.State trip tank volume
Mud Pits
Quantity: no. 4
Total Usable capacity: bbl 1718 bbl
Type (active/reserve): reserve or active
Height: cm 213.4 cm
Mixer: yes/no yes
Mud guns: yes/no yes

Slug Pits ( see F.2.3 )


Quantity: no. YES
Total Usable capacity: bbl 40 bbl
Height: ft 7f
Mixer: yes/no YES
Mud guns: yes/no YES

Mud Storage Pits


Quantity: no. N/A
Total Usable capacity: bbl
Type (active/reserve):
Height: ft
Mixer: yes/no
Mud guns: yes/no

F.2.3 Pill/Slug Tank

Capacity (usable): bbl 129 bbl


Mud agitator: yes/no
Mud guns: yes/no

F.2.4 Trip/Stripping Tanks

Capacity (usable): bbl 50 bbl


Capacity/foot: bbl/ft
Level indicator: yes/no yes
Electric pump make:
Model/type:
Rated capacity: hp 25hp
Facility for casing fill-up: yes/no yes
Alarm and strip chart recorder: yes/no yes

F.2.5 Chemical Mixing Tank N/A

Capacity (usable): bbl


Chemical mixer type:
F.2.6 Shale Shakers
The solids control system should be capable of handling
1200 gpm (in 26” and 16” hole sections) of return mud
heavily laden with cuttings at 1.25sg.

YES
All Solids Control Equipment to have separate,
dedicated centrifugal feed pumps and suction and YES
discharge lines.
CONTRACTOR shall supply a fully qualified Solids
Control Engineer to maintain and operate centrifuges
and all solids control equipment.
As
Screen Type
required flat

Primary:
Quantity: no. 3
Make/model: swaco BEM650
Type: high speed linear motion
Screen area upper / lower m2

Nominal flow rate (total): gpm

Cascading: N/A/...YESSS????
Quantity: no.
Make/model:
Type:
Nominal flow rate (total): bbl/min

Gumbo: N/A
Quantity: no.
Make/model:
Type:
Nominal flow rate (total): bbl/min
Flow Divider:
Quantity: no. 3
Make/model:
Type:
Nominal flow rate (total): bbl/min
F.2.7 Desander

Quantity: no. YES


Make/model: MI- SWACO MONGOOSE PT
CARBON H.B
Type:
Number of cones x size: no. x in 2
Centrifugal pump type: MISSON MAGNUM
Centrifugal pump size: in x in 8*6*12
Driven by electric motor of: hp 100 hp
Is pump dedicated to desander: yes/no yes
Min flow rate: gpm 1400 gpm
F.2.8 Desilter ?????????????????
Quantity: no.
Make/model:
Type:
Number of cones x size: no. x in
Centrifugal pump type:
Centrufugal pump size: in x in
Driven by electric motor of: hp
Is pump dedicated to desilter: yes/no
Min Handling flow rate: gpm
F.2.9 Mud Cleaner
Quantity: no.
Make/model: MI- SWACO MONGOOSE PT
CARBON H.B
Type:
Nominal flow rate: bbl/min yes
Number of cones: no. 16
Size: in 2"
Feed pump make/model: MISSON MAGNUM
Type/size: 11 " impeller
Capacity: gpm 1000 gpm
Drive motor hp: hp 100 hp
Is pump dedicated to mud cleaner: yes/no yes
F.2.10 Mud/Gas Separator (Poor Boy) ?????????????
Full drawings of the existing poor boy separator must be
given together with any proposed modifications to
comply with the following stated requirements.

Inspection and certification of the poor boy separator


unit is mandatory and must be provided by a recognised
certifying authority, eg, DNV or Lloyds to an acceptable
standard - specification for pressure vessels and
associated pipe work.
State rated working pressure.
The poor boy separator tank, or its gas outlet pipe must
be fitted with a pressure gauge with a read out at the
drill floor choke operating panel. Gauge must be sized
to provide accurate and detailed pressure readings of
poor boy separator pressures.
The interior of the poor boy separator must have a
mud/gas separating mechanism.
The poor boy separator must have a reliable liquid
sealing mechanism to retain gas in the separator tank
prior to its venting up the vent line. The seal can be in
the form of a ‘U’ tube or dip tube with a minimum seal
of 3.5m. CONTRACTORs shall state the hydrostatic
sealing pressures for the mud weights given for 12 1/4”
and 8 1/2” hole sections.
The separator vent line must be sized (minimum ID 10”)
to ensure that back pressure from venting gas is below
that of the hydrostatic pressure of the mud seal in the
poor boy separator

The pipe work downstream of the choke manifold to the


poor boy separator must be of sufficient wall thickness
to resist erosion. All bends should be minimised and
constructed of erosion resistant plugged tees or buffer
flanges. 90 degree swept bends will not be acceptable.

Make/type: Rapco
Design codes
Dimensions (height x OD): ft x in
Gas discharge line ID: in yes
Gas discharge location, primary:
Can discharge be tied into burner system: yes/no top of derrick
Design temperature Deg C
Vacuum breaker: yes/no
Hot mud injection yes/no
Mud seal height: ft
Pressure gauge: yes/no
Calculated gas throughput: mmscf
Test pressure psi
F.2.11 Degasser
Vacuum Degasser capable of handling 1000 gpm of
liquid mud throughput. ????
Please indicate what other pieces of solids control
equipment can be fed by the Degasser feed pump, or is
it a dedicated unit. State number of pumps (and HP)
available for solids control and degasser. ????
The gas outlet from the degasser must be separate from
that for the poor boy degasser/separator ????
Make/type: Swaco H-280
Nominal flow rate: gpm 1200 gpm
Feed pump make/model: ????
Type/size: 6*5*14
Capacity: gpm 1200 gpm
Drive motor hp: hp 75 hp
Is pump dedicated to degasser: yes/no yes
Vacuum pump make type: ingersoll rand v255/5hp/750rpm
F.2.12 Mud Agitators
Minimum number of mud mixing centrifugal pumps and
lines required is two(2). 5 agitators and 1 slug agitator
Please indicate if the mud mixing centrifugal pumps can
be used as pre-charge pumps for the main slush pumps
or any other function. yes
Minimum of 100 HP electric motors should be driving
the mud mixing centrifugal pumps. yes
Minimum of 2 High Pressure Mud Mixing Hoppers. yes
Mud Shearing Unit capable of providing 250 psi
shearing pressure at 500 gpm.
Quantity: no.
Make/model: 4
Driven by motor of power: hp GEOSOURCE
Located in tanks: 15 hp

Quantity: no.
Make/model: 1
Driven by motor of power: hp GEOSOURCE
Located in tanks: 3 hp
(see F.2.1 and F.2.2 for tank designations)

F.2.13 Mud Centrifuge


Quantity: no.
Make/model:
Feed pump make/model:
Type/size:
Capacity: bbl/min
Drive motor hp: hp
Is feed pump dedicated to centrifuge(s) yes/no
F.2.14 Vacuum System N/A
Mud vacuum system to clean up spills and converse
OBM. Preferred system to have at least a 20 bbl storage
tank and be permanently installed (hard line/PVC in all
critical areas, similar to central vac system).

F.2.15 Pressure Washer


High pressure (explosion proof ) washer to clean mud
tanks , drains . equipement , etc YES
F.2.16 Mud Recovery
Adequate space to house a (company supplied) Brandt YES
Tornado Dryerand Auger system
F.2.14 Mud Laboratory And Facilities
Separate room: yes/no NO
Equipped with:
Mud balance: yes/no YES
Marsh funnel: yes/no YES
Filtration kit: yes/no NO
Sand content kit: yes/no NO
Air Conditioning: yes/no YES
Positive pressure: yes/no NO

F.3 BULK SYSTEM


Bulk tanks to be fitted with weight indicator and
dust collectors, DC pressure pods to return
product to main storage and back load sample
points on each silo and fill times from boats are
required
F.3.1 Barite/Bentonite Silos
Quantity: No.
Capacity: ft3 3
Locations: 1425,1230,1150 f3
Type weight loadcell: sack room and pump room below
Manufacturer: Martine decker
Pressure rating: psi 45 psi
Relief valve(s) installed: yes/no yes
Additional information:

F.3.2 Cement Silos


Quantity: No. 3
Capacity: ft3 1425 f3
Locations: p tank room
Type weight loadcell: martine decker
Pressure rating: psi 45 psi
Relief valve(s) installed: yes/no yes
Separate mud/cement loading facilities: yes/no yes
Cement discharge independent from barite/bentonite: yes/no
yes

F.3.3 Surge Tank For Barite/Bentonite


Quantity: No. 1
Capacity of each tank: ft3 35 f3
Type weight load cell: martine decker
Manufacturer: martine decker
Pressure rating: psi 45 psi
Relief valve(s) installed: yes/no yes

F.3.4 Mud Hopper


Quantity: No. 3
Make/model: national
Feed pump make/model: mission
Type/size: 6*8 with 12" impeller
Capacity: bbl/min 28.5 bbl/min
Drive motor hp: hp 250 hp
Is feed pump dedicated to mud hopper(s): yes/no ??????????

F.3.5 Shear Jet


Quantity: No. N/A
Make/model:
Feed pump make/model:
Type/size:
Capacity: bbl/min

F.3.6 Surge Tank For Cement N/A


Quantity: No.
Capacity of each tank: ft3
Type weight load cell:
Manufacturer:
Pressure rating: psi
Relief valve(s) installed: yes/no
F.3.7 Bulk Transfer System
(see also C.1.7 - Compressed Air Systems)

Independent air system for the silos and surge NO


Tanks consisting of a high-volume low-Pressure
yes/no
compressor and air drier:
Air reduced from main air supply through Pressure
yes/no
regulators: YES
Separate volume tank and drier: yes/no YES
G. CASING/CEMENTING EQUIPMENT
G.1 CASING EQUIPMENT
G.1.1 Drive Hammer N/A

Make/type:
Minimum casing/conductor OD: in

G.1.2 API Casing Drifts

in/lbs/ft/n
For casing OD, weight, quantity:
o.
in/lbs/ft/n
For casing OD, weight, quantity:
o.
in/lbs/ft/n
For casing OD, weight, quantity:
o.
in/lbs/ft/n
For casing OD, weight, quantity:
o.
in/lbs/ft/n
For casing OD, weight, quantity:
o.
in/lbs/ft/n
For casing OD, weight, quantity:
o.

G.1.3 Clamp-On Casing Thread Protectors


For casing OD, quantity: in/no.
For casing OD, quantity: in/no.
For casing OD, quantity: in/no.
For casing OD, quantity: in/no.
For casing OD, quantity: in/no.
For casing OD, quantity: in/no.

G.1.4 Side Door Casing Elevator

Quantity: no.
For OD casing: in 13-3/8
Make/type:
Capacity: st 200 st

Quantity: no.
For OD casing: in 9/5/2008
Make/type:
Capacity: st 200 st

Quantity: No.
For OD casing: in 7"
Make/type:
Capacity: st 175 st

Quantity: No.
For OD casing: in
Make/type:
Capacity: st

Automatic Elevators
N/A
Quantity: no.
For OD drill pipe: in
For OD collars: in
For OD casing: in
Make/type:
Capacity: st

Quantity: No.
For OD casing: in
Make/type:
Capacity: st
G.1.5 Single Joint Casing Elevators

Quantity: No. 2
For OD casing: in 13-3/8 "
Make/type:

Quantity: No. 2
For OD casing: in 9 -5/8 "
Make/type:

Quantity: No. 2
For OD casing: in 7
Make/type:

Quantity: No.
For OD casing: in
Make/type:

Quantity: No.
For OD casing: in
Make/type:

Quantity: No.
For OD tubing: in
Make/type:

Quantity: No.
For OD tubing: in
Make/type:

Quantity: No.
For OD DP: in
Make/type:

Quantity: No.
For OD DP: in
Make/type:

G.1.6 Slip Type Elevator/Spiders

Quantity: No. none


Make/type:
Pneumatic/manual:
Capacity: st
Slips for OD tubing sizes: in

Quantity: No.
Make/type:
Pneumatic/hydraulic/manual:
Capacity: st
Slips for OD casing sizes: in

G.1.7 Casing Slips/Spiders

Quantity: No. 3
Make/type:
For OD casing: in various

Quantity: No.
Make/type:
For OD casing: in

Quantity: No.
Make/type:
For OD casing: in

Quantity: No.
Make/type:
For OD casing: in

G.1.8 Casing Bowls


Quantity: No. 2
Make/type: varco
For OD casing (max/min): in/in 9/5/2008

Quantity: No. 1
Make/type: varco
For OD casing (max/min): in/in 13-3/8

Quantity: No. 1
Make/type: varco
For OD casing (max/min): in/in 13-3/8
G.1.9 Manual Casing Tongs none
Quantity (sets): No.
Make/type:
W/jaws for OD casing (max/min): in/in

Quantity (sets): No.


Make/type:
W/jaws for OD casing (max/min): in/in

G.1.10 Power Casing Tongs none


Quantity: No.
Make/type:
W/jaws for OD casing (max/min): in/in
Max output torque: ft-lbs
Torque indicator: yes/no
Back-up arm: yes/no
G.1.11 Power Unit For Casing & Tubing Tongs

Quantity: No.
Make/type:
Capacity (ea.): gpm
Output pressure: psi
Dedicated unit: yes/no
G.1.12 Casing Circulating Head (Swedge)

For OD casing: Size


top/botto
Connection type:
m
G.1.13 Casing Spears (Internal)

Quantity: No.
Make/type:
For OD casing: in 13-3/8 " , 9 5/8 " , 7"
For casing weight: lbs/ft 68.72 , 43.5 , 23 lbs/f
Pack-off: yes/no

G.1.14 Casing Cutters (Internal)


Quantity: No.
Make/type:
For OD casing (max/min): in/in

G.1.15 Crossover to Handle Casing with Drill Pipe


Quantity: No.
For OD casing: in
Casing connection type:
Drill pipe connection type:
Rated capacity: st

G.1.16 Casing Scrapers


Quantity: No. 1
Make: 9 5/8 " , 7" , 5 "
For OD casing: in
For casing weight: lbs/ft
OD body: in
Connection type:
Blade type (roller/fixed)

G.2 CEMENTING EQUIPMENT


G.2.1 Cement Unit
Rig CONTRACTOR is fully responsible to provide
adequate space, all modifications and preparations
(cement line, water line mud line, fuel line and any other Yes/no
requirements) required to install the third party cement
unit and surge tanke, yes
Owner: third party/ Name of company?
Free placement basis: yes/no From Thrid party sheet???
Make/type: From Thrid party sheet???
No. of triplex pumps: No. From Thrid party sheet???
Maximum working pressure: psi From Thrid party sheet???
Maximum flow rate (total): bbl/min From Thrid party sheet???
Unit power by (electric/diesel): From Thrid party sheet???
Re-circulating mixing system: yes/no From Thrid party sheet???
Capacity: bbl From Thrid party sheet???
Motor power: hp From Thrid party sheet???
Liquid additive system: yes/no From Thrid party sheet???
Premix/batch tank: gal/min From Thrid party sheet???
Quantity: No. From Thrid party sheet???
Capacity (total): bbl From Thrid party sheet???
Pressure recorder: yes/no From Thrid party sheet???
Densiometer recording device: yes/no From Thrid party sheet???

G.2.2 Cementing Manifold


Discharge manifold working pressure: psi yes
Cement pump discharge lines min. ID: in
Cement pump discharge lines working pressure: psi
Manifold safety pressure relief valve: yes/no
G.2.3 Cementing Standpipe
Quantity: No. 1
Working pressure: psi 5000 psi
ID: in yes
Connection to choke manifold: yes/no
Connection to standpipe manifold: yes/no yes

G.2.4 Cementing Kelly


Quantity: No.
Nominal size OD: in
Total length: ft
Working length: ft
Connection type:
Cement head: yes/no

G.2.5 Cementing Tubing


Size: in
Length (total): ft
X-overs to drillpipe (specified in section D.1.3): yes/no
H. INSTRUMENTATION/COMMUNICATION
Instrumentation
Rig instrumentation - Included but not limited to the
following:
Weight indicator, rotary torque, makeup torque, RPM
and pump pressure gauges at Drillers console

One (1) computerised monitoring system (with monitors


on the Rig Floor, Tool Pusher’s office and OPERATOR’s
office) to monitor the following sensors: Pit volume
totalizer, Flo-Sho and alarms, complete with stroke
counters. Each pit to have pit level sensors that can be
switched into or out of total pit volume displayed on
Driller’s console by manipulation or switches on the
console. Trip tank readout recorder to be included.

5-pen geolograph with hook load, pump pressure, ROP,


torque and rotary speed.
Complete alarm system (gas, fire, H2S, etc.). Will be tied
into OPERATOR’S platform system.
Communication
VHF - AM helicopter transceiver, VHF - FM ship to ship
transceiver SSB radio telephone, satellite
communications equipment with telex facility, fax and
photocopier required. Space to be provided for Codan
Radio.

Communication equipment between platform and


OPERATOR shore base including permits and licenses.

Communication equipment (headset) between


CONTRACTOR’s HLO and helicopter pilot.
CONTRACTOR'S communication equipment including
permits and licenses:
Between rig and CONTRACTOR'S base.

Six (6) portable Radios capable of communication from


rig to adjacent workboats. Permanently mounted hands-
free system for the Crane Operators.

P.A. system on rig.


Intra-rig multi-station telephone communication system
with terminals between key points on rig including :
CONTRACTOR'S office, OPERATOR'S office, mud deck
area, mud pump area, rig floor, engine room, cranes,
cementing area, electric wire line, MWD and mud
logging units, and galley.
H.1 DRILLING INSTRUMENTATION AT DRILLER’S
POSITION
H.1.1. Weight Indicator
Make/Type: MD TATCO SPECTRUM 500
Sensor type: HOOK LOAD TRANSDUCER

H.1.2 Standpipe Pressure Gauges


Quantity: 2
Make/type: MD TATCO SPECTRUM 500
Maximum pressure reading: 0-6000 PSI

H.1.3 Choke Manifold Pressure Gauges

Quantity: No.
????
Make/type: MD TATCO SPECTRUM 500
Maximum pressure reading: psi 0-6000 PSI

H.1.4 Rotary Instrumentation


H.1.4.1 Tachometer No. ?
Make/type: MD TATCO SPECTRUM 500
Maximum RPM: psi ?

H.1.4.2 Torque Indicator


Make/type: HILL GRAHAMPLC/MD TOTCO
Maximum torque: rpm
H.1.5 Top Drive Instrumentation
H.1.5.1 Tachometer
Make/type: MD TATCO SPECTRUM 500
Maximum RPM: ft-lbs

H.1.5.2 Torque Indicator


Make/type: HILL GRAHAMPLC/MD TOTCO
Maximum torque: rpm
0-40000 PSI/ Topr drive till 45000 f.lb????

H.1.6 Pump Stroke Counters


Quantity:
Make/type: MD TATCO SPECTRUM 500
Stroke indicator and cumulative stroke ft-lbs YES
counter for each pump:

H.1.7 Tong Torque Indicator No.


Make/type MD TATCO SPECTRUM 500
Maximum torque:

H.1.8 Pit Volume Totalizer


Make/model: MD TATCO SPECTRUM 500
Float in active mud tanks: YES
Quantity per tank:
Floats in reserve mud tanks: YES
Quantity per tank:
Floats in mud processing tanks: YES
Quantity per tank: yes/no
Loss/Gain indicator: No. YES
Audio Alarm: yes/no YES
Visual Alarm: No. YES

H.1.9 Mud Flow Indicator No.


Make/model: MD TATCO SPECTRUM 500
High/low alarm: yes/no
Audio Alarm: yes/no YES
Visual Alarm: YES
Sensor location: BELL NIPPLE

H.1.10 Trip Tank Indicator


Make/model: yes/no MD TATCO SPECTRUM 500
Chart recorder: yes/no
Alarm:
H.1.11 Automatic Driller (see B.2.1) (not required)
H.1.12 Remote Choke Control Unit (see E.5)

H.1.13 Crown Clearance Indicator yes/no


Make/type: yes/no
H.1.14 Integrated Control Cabin & Information
System
Make/type GEOLOGRAPH/PIONEER 6 PEN
Quantity: 1
Control Console YES
Touch Screen yes/no NO
Weight Indicator System YES
Discreet Control Devices NO
Joystick activated Drawworks No. NO
Joystick activated Cathead NO
Emergency Stop/Park Brake yes/no YES
Block Control Range Override yes/no NO
Hole Fill Pump Start/Stop yes/no NO
Trip Tank Pump Start/Stop yes/no YES
Drill Floor Emergency Shutdown yes/no YES
UPS (None/Single/Dual) yes/no NO
Multi Tool Control (MTC) Cabinet yes/no
Drilling Signal distribution System: yes/no
Make/type yes/no

Electronic gauges for primary drilling instrumentation yes/no

Pit Volume Totaliser YES


Electronic Drilling Recorder yes/no YES
Drilling Information management system:
Make/type
Realtime
Printed Report Types

H.2 DRILLING PARAMETER RECORDER GEOLOGRAPH/PIONEER 6 PEN | RigSense???


Quantity:
Make/type: yes/no
Location - 1:
Type (display/recorder/both):
Location - 2:
Type (display/recorder/both): No.
Location - 3:
Type (display/recorder/both):
Number of parameters recorded:
Parameter recorded:
Parameter recorded:
Parameter recorded:
Parameter recorded:
Parameter recorded: No.
Parameter recorded:
Parameter recorded:
Parameter recorded:
H.3 INSTRUMENTATION AT CHOKE MANIFOLD
H.3.1 Standpipe Pressure Gauge (Drill pipe pressure
gauge)
Quantity: 2
Make/type: TOTCO/ MD
Pressure range (maximum): 10000
Visible from choke operating position: ?
H.3.2 Choke Manifold Pressure Gauge (Casing
pressure gauge) YES??
Quantity: No. 1
Make/type: psi 0-5000 PSI
Pressure gauge: yes/no ???

H.4 INSTRUMENTATION AT STANDPIPE


H.4.1 Standpipe Pressure Gauge no.
Quantity: 1
Make/type: psi/psi 0-5000 PSI
Pressure gauge: YES
Visible from driller’s position: YES
Visible from choke operating system: No. ????

H.5 DEVIATION EQUIPMENT


H.5.1 Deviation Recorder psi/psi
Quantity: yes/no
Make/type: yes/no
Deviation range:

Deviation Instrument
. Make and type No.
. Recording/range
degree/de
. Go-devil diameter
gree
. Recovery equipment

H.5.2 Slickline Unit (see B.2.4) No.

H.6 RIG COMMUNICATION SYSTEMS degree


H.6.1 Rig Telephone System inch
No. of stations: 20+/????
Make/type: GAITRONICS
Explosion proof: YES , IN HAZARDOUS AREA
H.6.2 Public Address System
Can be combined with H.6.1 above: yes/no same equipment
No. of stations: No. GAITRONICS
Make/type: YES , IN HAZARDOUS AREA
Explosion proof: YES , IN HAZARDOUS AREA

H.6.3 Drill Floor Talkback System yes/no


No. of stations: No. 2
Location: dog house , monkey board
Location:
Location:
Make/type:
Explosion-proof: yes

H.6.4 Hand Held VHF Radios


Quantity: 8/ ????
Quantity intrinsically safe: yes/ ???

H.6.5 Crane Communication System


Quantity: 2
Make/type: No. GAITRONICS
Explosion proof: No. no
Part of rig telephone system (H.6.1): yes
Part of public address system (H.6.2): yes

H.6.6 Computer Network LAN


Make/type: yes/no yes
Fiber Optics: yes/no all offices
Outlet Locations: yes/no

H.7 ENVIRONMENTAL INSTRUMENTATION


H.7.1. Temperature Indicators
Air temperature (make/model): yes/no
Recorder: taylor
Sea water temperature (make/model):
Recorder:

H.7.2 Barometric Pressure Indicator


Make/model: yes/no
Recorder: yes/no taylor

H.7.3 Humidity Sensing Indicator


Make/model:
Recorder:
yes/no
H.7.4 Wind Speed/Direction Meter
Make/model:
Recorder: yes/no starfire

H.7.5 Wave Profile Recorder


Make/model:
Recorder:
yes/no
H.7.6 Current Indicator
Make/model: N/A
Located at:
Recorder: yes/no

H.7.7 Weather Facsimile


Make/model: N/A
Located at:
Recorder: yes/no

H.8 NAVIGATION INSTRUMENTATION


H.8.1 Gyro Compass
Make/model: yes
Located at: yes/no control room

H.8.2 Depth Sounder


Make/model: N/A
Located at:
Recorder:

H.8.3 Radar
Quantity: N/A
Make/model: N/A
Located at: yes/no N/A
Bandwidth: N/A
H.8.4 AIS System N/A
Should be provided by CONTRACTOR No. jorton /TR-8000 Radio Rm
H.9 EXTERNAL COMMUNICATIONS EQUIPMENT
H.9.1 SSB Transceiver
Location(s): cm
Quantity:
Make/model:
Power: sailor compact GMDSS
Frequency ranges (low/high): 10dbm/20 dbm
(Synthesized crystal):
Facsimile capable (see also H.9.9): No.
Telex capable (see also H.9.10):
watts
H.9.2 E.P.I.R.B’s mhz/mhz
Quantity:
Make/model: yes/no 2
Location(s): yes/no Simard type RD68

H.9.3 Marine VHF Radio


Quantity: No.
Make/model: 2
Power: FURNO
Channels:
Location:
No.
Quantity:
Make/model: watt SAILOR
Power: 5 watt
Channels:
Location:
Number No.
Quantity:
Make/model: watt
Power:
Channels:
Location:
Number No.
H.9.4 Aircraft Radio Beacon Transmitter (NDB)
Quantity: watt
Make/model:
Power:

H.9.5 Aeronautical VHF Transceiver


Quantity: No. 1
Make/model: icom ic -a 3e/portable
Power: watts
Frequency range (low/high):
(Synthesized/crystal):
Location(s): No.

Quantity: watts 1
Make/model: mhz/mhz DITTEL TYPE FSG 4/PORTABLE
Power:
Frequency range (low/high):
(Synthesized/crystal):
Location(s): No.

H.9.6 Watch Receiver


Quantity:
Make/model:
Frequency:

H.9.7 Satellite Communication System


Make/model: No. rig net
Type:
Facsimile capable (see also H.9.9) khz yes
Telex capable (see also H.9.10)
Location(s):

H.9.8 Inmarsat
Number of phone lines: yes/no ???????????????

H.9.9. Facsimile
Make/model:
Connected to:

H.9.10 Telex
Make/model:
Connected to: Yes
Rig Net
H.9.11 Scrambler
Make/model:
Connected to:

H.9.12 Other Communication System


Make/model: fleet 77
Connected to:

Make/model: furno/ fm-8500 2597-0725


Connected to: VHF Radio telephone

Make/model: furno/ fm-8500 2597-0726


Connected to: VHF Radio telephone
I. PRODUCTION TEST EQUIPMENT
I.1 BURNERS
Make/type:
Quantity:
Capacity:
Weight:
Water requirement at 100 psi:

I.2 BURNER BOOMS No.


Make/type: bbl/day
Quantity: st
Length: bbl/min
Horizontal:
Maximum wind speed:
Walkway and handrails:
Burner platform size: No.
Burner mounting rotatable: ft
yes/no
I.3 PIPING ON BURNER BOOMS knots
I.3.1 Oil Line yes/no
ID: ft x ft
Working pressure: yes/no
Connection type at burner end:
H2S:
Pressure gauge connection at barge end:

I.3.2 Gas Line ksi


ID:
Working pressure: yes/no
Extended beyond burner by: in
Connection type at burner end:
H2S:
Pressure gauge connection at barge end: in

I.3.3 Water Line ft


ID:
Working Pressure: yes/no
Connection type at burner end: in
Pressure gauge connection at barge end:

I.3.4 Air Line in


ID: psi
Working Pressure:
Connection type at burner end: in
Pressure gauge connection at barge end:

I.3.5 Pilot Gas line in


ID: psi
Working Pressure: type
Connection type at burner end: in
Pressure gauge connection at barge end:

I.4 SPRINKLER SYSTEM (not required) in


System in place: psi
Pump source: type

I.5 FIXED PIPING FOR WELL TESTING (not required)


??????????????????????
I.5.1 Drill Floor to Separator Area
Type (screwed/welded, both): yes/no
Quantity:
Size ID:
Working pressure:
Connection on drill floor:
Connection at separator:
Number of valves/lines: No.
Size of valves: in
H2S: psi

I.5.2 Separator Area to Burner Booms type


Service (oil/gas): no.
Type (screwed/welded, both): in
Quantity: yes/no
Size ID:
Working pressure:
Connection at separator:
Connection at boom:
Number of valves/lines: No.
Size of valves: in
H2S: psi
Valves installed near separator area for type
switching gas to either burner: type
no.
I.5.3 Water Lines to Burner Booms in
Type (screwed/welded/both): yes/no
Quantity:
Size ID: yes/no
Working pressure:
Number of valves required:
Size of valves:
Pump source: No.
Rated line capacity at 300 psi: in
psi
I.5.4 Air System to Burner Booms no.
Type (screwed/welded/both): in
Quantity:
Size ID: bbl/hr
Working pressure:
Non-return valves fitted:
Air source:
No.
I.5.5 Oil Storage Tank To Offload in
Type (screwed / welded / both): psi
Quantity: yes/no
Size ID:
Working pressure:
Connection at separator area:

I.5.6 Separator to Vent Stack of Rig No.


Type (screwed/welded, both): in
Quantity: psi
Size ID: type
Working pressure:
Connection type at separator area:

I.6 AUXILIARY POWER AVAILABILITY (not required) No.

I.6.1 For Field Laboratory in


Quantity: psi
Volts: type
Frequency:
Breaker:

I.6.2 For Crude Transfer Pump No.


volts
Quantity: hz
Volts: amp
Frequency:
Breaker:
I.6.3 For Electric Heaters No.
Quantity: v
Volts: hz
Frequency: amp
Breaker:
J.WORKOVER TOOLS N/A
No.
v
hz
amp

K. ACCOMMODATION
K.1 OFFICES
K.1.1 Company Representative’s Office
Quantity: 1
State rooms in above:
Complete with desk, filing cabinets(s) and
other necessary furniture: YES
Quantity with unrestricted view to 1
drill floor: No.
No.
K.1.2 CONTRACTOR’s Representative’s Office
Quantity: yes/no 1
Quantity with unrestricted view to 1
drill floor: Yes/no.

K.1.3 Control Room No. 1

K.1.4 Radio Room No.


Quantity: 1

K.1.5 Helicopter Ready Room No.


Quantity: 1

K.1.6 Hospital Room No.


Number of beds/bunks: 1
Dangerous drugs locker: YES
No.
K.2 LIVING QUARTERS
K.2.1 Accommodations
Total Beds: No. 100
No. of beds per room type (1,2,3, etc): yes/no 2
Number of rooms: 12
Toilets (private/shared/communal):
Showers (private/shared/communal):
Beds available for Company No.
Total beds available for Company:
No. of beds per room type (1,2,3, etc) for company
Number of rooms:
K.2.2 Galley
Quantity: No. 1

K.2.3 Mess Seating Capacity No.


Main mess: 36 seats
Aux. mess: N/A
No.
K.2.4 Meeting Rooms
Quantity: No. 1

K.2.5 Recreation Rooms


Quantity: 1
Recreation facilities
TV: No. 1
VCR / DVD: 1
Projector fit with PC
Pool Table: No.
Ping Pong Table:
Computer: No.
Gym/Workout/weight room: No.
Other: 1
3* Sattelite dish
K.2.6 Other Rooms
Change rooms:
Prayer room: 1
Cinema: 1
Other: N/A
L.1 GENERAL SAFETY EQUIPMENT N/A
SAFETY CRITICAL EQUIPMENT ??????
DEFENETION No. YES
LIST YES
SYSTEM FOR MONITORING YES
L.1.1 General Personnel Protective Gear
Safety Goggles (CONTRACTOR/everyone/not supplied):
CONTRACTOR
Safety glasses (CONTRACTOR/everyone/not supplied): YES
CONTRACTOR
Safety hats (CONTRACTOR/everyone/not supplied): YES CONTRACTOR
Safety boots: Lace up type with ankle support
YES
(CONTRACTOR/everyone/not supplied): CONTRACTOR
Safety clothing non flammable
(CONTRACTOR/everyone/not supplied): NOT SUPPLIED
Ear protection (CONTRACTOR/everyone/not supplied):
CONTRACTOR
Rubber gloves (CONTRACTOR/everyone/not supplied):
CONTRACTOR
Rubber aprons (CONTRACTOR/everyone/not supplied):
CONTRACTOR
Rubber gloves - elbow length (CONTRACTOR/everyone
not/supplied): CONTRACTOR
Full face visors (CONTRACTOR/everyone/not supplied):
CONTRACTOR
Eye shields (CONTRACTOR/everyone/not supplied): CONTRACTOR
Dust masks P1,P2,P3 (CONTRACTOR/everyone/not
supplied): CONTRACTOR
Explosion proof hand torches
(CONTRACTOR/everyone/not supplied): CONTRACTOR
Safety Harnesses & Lanyards:
(CONTRACTOR/everyone/not supplied): CONTRACTOR
Inertial Reels (CONTRACTOR/everyone/not supplied):
CONTRACTOR
Rubber Bootsfor Chemical; mixing
(CONTRACTOR/everyone/not supplied): CONTRACTOR
L.1.2 Decontamination Stations
L.1.2.1 Eye Wash Stations
Quantity - fixed: 5
Make/model:
Location(s):

L.1.2.2 Safety Showers


Quantity:Fixed No. 5
Make/model

Location(s): Rig Floor,Mud Pit, Mixing area,Shale Shaker

L.1.3 Derrick Safety Equipment


Derrick escape chute (rem chute): No. 1
Make/type:
Geronimo line:
Derrick safety Harness: 1
Make/type:
Derrick safety Harness: No.
Make/type:

L.1.4 Derrick Climbing Assistant


Make/type: 2/???? Counterbalance??

L.1.5 Fresh Air Blowers (Bug Blowers)


Quantity: 6
Make/type:
Located at:

L.2 GAS/FIRE/SMOKE DETECTION


L.2.1 H2S Monitoring System No.
Make/type: Dooley Tackaberry Gastech 2321
Sampling points at:
Bellnipple: yes
Drillfloor: yes
Shale shaker: yes
Mud tanks: yes
Ventilation system into living quarters: yes
Other: yes/no
Alarms at: yes/no
Driller’s console (audible/visual/both): yes/no both
Engine room (audible/visual/both): yes/no both
Mud room (audible/visual/both): yes/no both
Living quarters each level (audible/visual/both): both
Central area each structural level (audible/visual/both):
yes
Other:

Tied to general alarm: yes


Central control panel: yes
Located at: control room
Local alarm (audible/visual/both): both

L.2.2 Combustible Gas Monitoring System yes/no


Make/type: yes/no Dooley Tackaberry Gastech 2321
Sampling points at:
Bellnipple: yes
Drillfloor: yes
Shale shaker: yes
Mud tanks: yes
Ventilation system into living quarters: yes
Other: yes/no above sack store engine supply fan
Alarms at: yes/no
Driller’s console (audible/visual/both): yes/no both
Engine room (audible/visual/both): yes/no both
Mud room (audible/visual/both): yes/no
Living quarters each level (audible/visual/both):

Central area each structural level (audible/visual/both):

Other:
Tied to general alarm: yes
Central control panel: yes
Located at: control room
Local alarm (audible/visual/both): both

L.2.3 H2S Detectors (Portable) yes/no


Quantity: yes/no 5
Make/type: BIO MULTI GAS DETECTOR
Quantity:
Make/type:
Stain types for H2S: measuring range: N/A
from 1 to 20 percent: No. N/A
from 5 to 60 percent: N/A
No.
L.2.4 Explosimeters
Quantity:
Make/type: %
%
L.2.5 CO2 Gas Detectors (portable)
Quantity: No.
Make/type:
Stain tubes for CO2: measuring range N/A
from 1 to 20 percent: N/A
from 5 to 60 percent: N/A
L.2.6 O2 Meter (portable)
Quantity: No. Clinic?
Make/type:

L.2.7 Fire/Smoke Detectors in Accommodation


Make/type:
Fire detection: Dooley Tackaberry pyrotronics system 3
Smoke detection: yes
Central control panel: yes
Location: yes
Alarms: radio room
Pull boxes: yes/no
Mud room (audible/visual/both): yes/no
Living quarters each level (audible/visual/both) yes/no
Central area structural level:
(audible/visual/both): No.
Other: No.
Tied to general alarm:
Central control panel:
Located at:
Local alarm (audible/visual/both):

L.3 FIRE FIGHTING EQUIPMENT


L.3.1 Fire Pumps
Quantity: 2
Make/model: HARRISBURG 2”*3”
Type: HARRISBURG
Output (each): 500 US gpm
Location: Mud pump room-auxillary room
All off-take points supplied by all pumps: yes

L.3.2 Hydrants and Hoses

Hydrants positioned such that any point may be reached


yes/no
by a single hose length from two separate hydrants:
yes
Quantity of hydrants: no. 20
Hose connections/hydrant: no.
Hose. max. diameter: in 2
Length: ft 50 f

L.3.3 Portable Fire Extinguishers


Quantity (total): No.
Type 1 - CO2 no./lbs 89

2/5LBS
Type 2 - Dry chemical no./lbs 8/10LBS
18/15LBS
4/20LBS

1/ 150 lbs
18 / 20 lbs
Type 3 - Foam no./lbs
15 / 10 lbs
7 / 15 lbs
5/5lbs
10/ 9 Liter
Type 4- Water no./lbs 1/45 Liter

Type 5- Halon no./lbs N/A


Type 6 - Dry powder no./lbs N/A
L.3.4 Fire Blankets
Quantity: no./lbs
Location(s): no./lbs 4
Galley,Welder work shop,Paint locker
L.3.5 Fixed Foam System
Make/type:
Quantity of foam concentrate stored: No. ANSUL
Foam type: 200
Application rate: AFFF
Foam nozzles:
Located at: 4
Located at: gal Helideck
Located at:
Automatically injected into fixed fire gals/min
water system: no.
Make/type:
Quantity of foam concentrate stored:
Foam type:
Application rate: yes/no
Foam nozzles:
Located at:
Located at: gal
Located at:
U.S.
Automatically injected into fixed fire
gals/min
water system: no.
L.3.6 Helideck Foam System
Make/type:
Quantity of monitors: Each 1
Quantity of foam concentrated stored: gal yes/no
Foam type: AFFF 3 %
Application rate: 900 gpm

L.3.7 Fixed Fire Extinguishing System No.


Protected spaces:
Engine room, type (Halon/CO2/other): Engine room , mud pits & Paint locker
Remote manual release located at: gals/min CO2
Paint locker, type (Halon/CO2/other): Main deck & SCR
Remote manual release located at: CO2
Emergency generator type (Halon/CO2/other): Main Deck
Remote manual release located at:
SCR room type (Halon/CO2/other):
Remote manual release located at:
Other (specify location & type):
Remote manual release located at:
Alarms *audible, visual, or both):
Automatic shutdown of ventilation fans
in protected spaces:

L.3.8 Manual Water Deluge System


Protected spaced: Yes
Protected spaced: BOP & Rotary
Water supplied from fire main line: yes/no
Yes
L.3.9 Water Sprinkler System in Accommodation yes/no
Automatic activation: Yes
Working pressure: No
Tank capacity: yes/no 120
Salt water backup: Direct from Deep well
Type (wet pipe/dry pipe)
L.4 BREATHING APPARATUS yes/no
psi
L.4.1 General Sets gal
Quantity: No. 2
Make MAKO
Type (demand/positive pressure):
Cascade system quick connects: YES
Cylinder duration: 30 mins/15 mins
Located at: No. various areas
Located at:
Located at:
Located at: yes/no
Located at: min
Located at: qty/loc
qty/loc
L.4.2 Escape Sets
Quantity:
Make 115
Type (demand/positive pressure): CamLock
Cascade system quick connects: positive pressure
Cylinder duration:
Located at: 15
Located at: Distrbuted @ Cabin

L.4.3 Cascade Stations


Quantity:
Make/type: 45
Manifold locations/outlets at location:
Manifold locations/outlets at location: drill floor/18
Manifold locations/outlets at location: BOP/9
Manifold locations/outlets at location: shale shaker /6
Manifold locations/outlets at location: pump room/6
Manifold locations/outlets at location: mud pit room/3
cement unit /3
L.4.4 Breathing Air Recharge Compressor
Quantity:
Make/type: 2
1 x Desiel and 1 x Electric Compressed air storage
capacity: mako
Working pressure: yes
Located at: 5th flor
Located at: 5th flor
Spare 30 minute cylinders
L.4.5 Compressed Air Breathing Apparatus Trolley
Unit N/A
Make:
Type (demand/positive pressure):
Air line length:
Compressed air storage capacity:
Working pressure:
Including:
Face Mask:
Demand valve:
Microphone:
Safety harness:
Safety line (incorporating telephone line):
L.4.6 Breathing Air Purity Test Equipment
Quantity:
Make/type:

L.5 EMERGENCY FIRST AID EQUIPMENT


L.5.1 First Aid Kits
Quantity: 10

L.5.2 Burn Kits


Quantity: 4

L.5.3 Resuscitators
Quantity: 1
Charged (spare) oxygen cylinders: 2
Defibulator
L.5.4 Stretchers
Quantity: 4
Type: various??
Located at: various locations???

L.6 HELIDECK RESCUE EQUIPMENT


Aircraft Axe: as required by SOLAS
Large fireman’s rescue axe: Yes
Crowbar: Yes
Heavy duty hacksaw: Yes
Spare blades: Yes
Grapnel hook: Yes
Length of wire rope attached: Yes
Quick release knife: 15 Feet???????????
Bolt croppers: Yes
Fireman’s outfit: Yes
CO2 Lance: Yes
Other: Rescue Ladder Yes
Other: SCBA Yes
Yes
L.7 EMERGENCY WARNING ALARMS
Approved system to give warning of
different emergencies: YES
Activated from drill floor: NO
L.8 SURVIVAL EQUIPMENT
L.8.1 Lifeboats

Lifeboats are to be located at either side of the drilling


unit for safety reasons. Please provide a plan view of the
drilling unit showing the locations of the lifeboats.

Life saving plan (100 % )


State percentage capacity based on maximum
complement. (minimum 100%)
Make/type: yes
Quantity: fassmer CLR-T-8.5
Capacity: 2
Locations (frwd/aft/port/stbd): 60 PERSON/Craf
Fire protection: port/stbd
Radio/EPIRB (see section H.9): yes
L.8.2 Liferafts
Two or more life rafts covering a minimum of 100% of
the complement. Both Davit launched. Please provide
site layout showing placement of rafts.
Life saving plan (100 % )
Lifeboat to be equipped with VHF and Solas II or
equivalent communication systems.
Make/type: yes
Quantity: Zodiac / Viking
Capacity: 4
Davit launched: 25/liferaf
Locations (frwd/aft/port/stbd): yes
Port & STBD FWD
L.8.3 Fast Rescue Boat
Make/type:
Engine power: Hp ACHILLES
Johnson 55
L.8.4 Personal Flotation Devices
Make/type:
Quantity: Type 1
L.8.5 Survival Suits 115/????????????????????
Possibley not required in this climate N/A
Make/type:
Quantity:
L.8.6 Life Ring Buoys
Make/type Commercial Ring Buoy Type IV
Quantity total: 10/ 20 total I guess???
with lights: 10
with smoke: 3
with EPIRB: nil
nil
L.8.7 Work Vests
Quantity: 8
Inflateable Work life vest fitted with Fall Arrest Harness
& Light (Solas)
L.8.8 Escape Ladders/Nets
Make/type: comar Embarkation
Quantity: 2
M. POLLUTION PREVENTION EQUIPMENT
Must meet the standards of the Egyptian Environmental
Law 4 of 1994 yes
M.1. SEWAGE TREATMENT
Sewage system must be operable and designed to
handle the maximum number of persons on board.
There must be a facility in place for sampling of effluent.

Must meet the standards of the Egyptian Environmental yes


Law 4 of 1994
Make/model: Omnipure
System type: ELTECH
M.2 GARBAGE COMPACTION
To be provided by CONTRACTOR. Must meet normal
anti-pollution requirements. YES
Must meet the Egyptian Environmental Law 4 of 1994

Make/model: Scavenger
System type: 30 cu.f
M.3 GARBAGE DISPOSAL/GRINDER
Make/model:
System type: 1 tuff guts
Grinder
M.4 INCINERATOR
Make/model: N/A
System type:

M.5 OILY WATER SEPARATOR


Quantity:
Make/model: 1
System type: alfa laval
Nominal throughput:
N. DRILLING DATA EQUIPMENT
N.1. COMPUTERS (HARDWARE & SOFWARE)
N.1.1 Server System
Make / System
CPU
Monitor
Harddrive
Optical Storage
Backup Facility
Operating System
Software System
Misc.
N.1.2 Peripherals
Printers
Ethernet link

N.1.2 Workstations
Make / System
Monitor
Software System
N.1.3 ACQUISITION NETWORK
Drill flow acquisition panel with firmware will be provided
1 – TBA interface will be provided
2 – RDA interfaces will be provided
Mud area acquisition panel with firmware: will be provided
2 – RDA interfaces will be provided
Mud logging unit acquisition box; will be provided
1 – RDA for 8 analog channels will be provided

SENSORS:
1 - crown block encoder sensor NOV
1 - motion compensator encoder sensor MD totco
1 - slip joint encoder sensor will be provided
1 - kelly in/out detector MD totco
1 - hook load MD totco
1 - rotary in/out will be provided
1 - rotary gear box h/l NOV
1 - rotary RPM. MD totco
1 - top drive RPM MD totco
1 - rotary torque MD totco
1 - top drive torque NOV
1 - stand pipe pressure MD totco
1 - choke line pressure MD totco
1 - cementing line pressure will be provided
1 - cementing line pump strokes counter will be provided
1 - mud pump 1-SPM MD totco
1 - mud pump 2-SPM MD totco
1 - trip tank level MD totco
1 - active mud tank level NOV
1 - active reserve mud tank level MD totco
1 - reserve mud tank level MD totco
1 - treatment mud tank level MD totco
1 - desilter tank level MD totco
1 - desander tank level MD totco
1 - slug tank level MD totco
1 - prehydrate tank level MD totco
1 - sand tank status MD totco
1 - sand tank No. 2 level MD totco
1 - deck tank No. 1 level MD totco
1 - deck tank No. 2 level MD totco
1 - transfer mix-pump No. 1 On/Off.
1 - transfer mix-pump No. 2 On/Off.

O. DRAWINGS
O.1. REFERENCES
Checked Items

No Cirtificates indicating Rig compliance

6" jetting line


Rig Operations Manual
4" Jetting Line
1000 Kips ( combined of the following:)
1000 Kips
Rig Operations Manual
750 Kips
450 Kips
25,200 Kips (8,400 Kips/leg) Rig Operations Manual

10 - 12 hours (According to the dedicated Pumps) Actual

4,679 Kips (do NOT exceed 418 Kips/pinion)


25,200 Kips (700 Kips/Pinion) Rig Operations Manual
1.1 up / 1.3 down f/min

4
leg Rig Papers
93 f

3 Actual
0 Actual

300 f
300 f

N/A
25,200 kips Rig Operations Manual
8.44 Kips/f 2

50 f (storm Mode)
13.5 Sec. (storm Mode)
Rig Operations Manual
Rig Operations Manual
100 knots (storm Mode)

2 knots (storm Mode)


Camlock Actual

N/A

N/A
N/A

N/A
N/A

N/A
N/A

No
59100 lbs (26.8 Ton) / 18.8 radius Manual

26.8 Ton / 18.8 radius Crane Manual

8,600 lbs Static and Dynamic Crane Manual


8600 lbs Crane weight indicator
5000 lbs (2.6 Ton) Name Tag

No
NO
Hoisting Delta Plate (for bow toing wire)
1
ingersoll rand
K6- UL
5000 lbs
5/8 "
N/A
N/A
N/A
No
Bow
200 STDS / 19000 f

209 STDS

Pyramid
18 f 47 f
N/A
N/A

Yes (Exist but not working)

Brake Band

Crown -O - Matic SS Model TCB

No

Checked
Checked
baylor switchover unit model #56380 REU.H
TULSA POWER/WLTU-25 NAME PLATE

25,000 lbs NAME PLATE

500 Ton Continental Emsco Manual

500 Ton NOV

7500 f Drum
checked ok

checked ok

checked OK
N/A

N/A Checked
N/A Checked
35 - 50 bbls/day (AVG.) As an average (workover)
Yes ( but there is a lack in the LOTO lockers)

Quincy QT-2
Diesel

2
Quincy
QSI - 500 ANA 32G

Quincy QCI-500
120 PSI Manual
Electrical
125 hp

CAT 353 D Checked


not all subs are inspected

N/A

10,900 f (350 jts*31.3f) checked


13.3 lb/f checked

1x5f
refered to inventory prepared
2 x 10 f on Jul. 2017
2 x 15 f

1x5f
refered to inventory prepared
1 x 10 f on Jul. 2017
1 x 20 f
What is Drill Pipe Casing Protectors???
?????

N/A

4 3/4"
2"
9 jts
30 f
Spiral
Checked
yes
yes
Checked

No Stress relief groove


NO bore back
3 1/2 IF
7 5/8" Reg. lifing sub

6 5/8 " Reg. lifing sub (Inventory attached)


2

6 1/2" refered to inventory prepared


on Jul. 2017
4 1/2 " IF
10,000 psi

4 3/4" refered to inventory prepared


2 1/4" on Jul. 2017
3 1/2" IF
10,000 psi

1
WECO 2" 1502
Checked & refered to inventory
N/A prepared on Jul. 2017

5" CSG

7" CSG

9 5/8" CSG

yes
5F-6R | 2F-3R | 4 R
6 5/8" Reg. & 7 5/8" Reg. | 3 1/2"Reg. | 4 1/2" Reg.
1|1|1

Refer to the attached Inventory


Refer to the attached Inventory

5"
1
BJ
GG
350 Ton
3 1/2"
2
BJ
MGG
250 Ton
5"
1
M&W
Side door
100 Ton

7"
1
VARCO
SSD Side door
150

9 5/8"
2
VARCO
SLX Side door , Bj Side door
150

13 3/8"
2
VARCO
SLX Side door , Bj Side door
150
3 1/2"
2
VRCO SDML
5"
1
VARCO SDXL

N/A

4 3/4"
1
VARCO DCS-R
8 1/4"
1
VARCO DCS-L

1
MP-R (6 3/4" - 8 1/2")
2* 2 3/8" + 2 * 2 7/8" + 3 * 3 1/2 "

Refer to the attached Inventory


1
6"

1
6 1/2"

2
8 1/2"

1
12 1/4"

1
17 1/2"

2
VARCO / WELDLESS
3 1/2"
108"
350 Ton

1
VARCO / WELDLESS
3 1/2"
144"
500 Ton

1
VARCO / WELDLESS
3 1/2"
180
500 Ton

1
VARCO / WELDLESS
4 1/2"
144"
750 Ton

DRILCO
150,000 lbs
N/A
All Fishing Tools has been sent to ADM 88 Ecept the
following:

1
BOWEN
5 3/4"

According to basket Grapple and spiral grapples


available

5 3/4"
2f

both

3 1/2 " IF
NO Diverter on ADM V
NO Diverter on ADM V

Port side below cantiliver

Shaffer
Rig Floor

Yes Extrudable Seal

1
cameron/ type U
Double
13 5/8"
10,000 psi
Yes
Manual
Yes
Yes
3 1/16"
10,000 psi
Hub Flange 10 K
Hub Flange 10 K
Yes

2/Pipe Ram/7"

2/Pipe Ram/5"
Inventory
2/Pipe Ram/3 1/2"
2/Pipe Ram/9 5/8"
Inventory

1/blind

2 7/8 - 5" VBR ( Cameron U type 10K)

SBR ( Cameron U type 10K) Checked

3 1/2" Pipe Ram ( Cameron U type 10K)

What is Close-on-open-hole test


1
HYDRIL/GK 5000 psi
13 5/8"
5000 Psi
Flanged/ BX 160
Bolts (for Bell Nipple conn.)
Pad Eyes

N/A
yes

yes

yes

yes
yes

3 1/16"
10,000 Psi
BX 154
Hydraulic + Manual Only

1
Cameron
3 1/16"
10,000 PSI
Bx 154
Hydraulic

1
Cameron
3 1/16"
10,000 PSI
Bx 154
Manual
Refer to the attached Inventory

3 1/2"
As Per Inventory done on Jul.
2017
3 As Per Inventory done on Jul.
3 1/2" IF 2017
10,000 PSI

5"
2 As Per Inventory done on Jul.
4 1/2" IF 2017
10,000 PSI

3 1/2"
3 As Per Inventory done on Jul.
3 1/2" IF 2017
10,000 PSI

5"
2 As Per Inventory done on Jul.
4 1/2" IF 2017
10,000 PSI

yes
Koomey Type 80/ Model No. UET15HT460
1
Below Cantiliver port side

1
N/A
N/A Accumulator Operating
Manual
110 Gal (22 btls * 5 gal)
1000 Psi
3000 Psi
UE2RB09A07
TR Drilling Controls Air Operated

Yes (75 gal required, 110 gal usable)


yes
yes
3
COMMANDER Speeflo 742-140-B Name Plate
According to Air Pressure w/ratio of 60/1

Through Panel
No
Yes
3 1/16"
2 1/16"
10,000 psi

N/A

Rig Floor Driller Cabinet


3"
10,000 psi Hose Certificate
yes

12
Coflex
1"
5000 psi
Yes
Adjustable working platform (air tuggers hoisted)
N/A

N/A

5000 psi
Inspection Certificates
7500 Psi

Different Sizes ranging F/5" T/7"


yes
yes
2

mission 8*6*14
According to attached chart
mission
mission 8*6*14
According to attached chart
Emerson
Name tag
100 hp

4,000 psi
Steel band indicating

yes 3"
yes 2"
yes 2"

50" Hose Certificate


2"
15,000 psi

Weco Pup Joints


2" 1502
2"
15,000 psi
12 f
2
10 f
1
Chiksan® swivel FMC
2"
Yes
See F.2.3

132 bbls
yes
yes

52 bbls
7.5 bbls/f
yes

mission 4*3*13
Name plate
20 hp
yes
yes

yes (3 shakers and a Mud cleaner)

Checked
yes (but Desander 7 Desilter have the same
centrifugal pump)
Checked

yes

DURAFLO composite screens

According to installed screens and mud properties

N/A
1
MI-swaco
mongoose pro 14"
16*4"
mission
8*6*14
75 hp
NO
75 gal each (max.)

Yes
According to the gas cut mud being processed

dedicated

yes

mission 8*6*14
N/A

N/A

N/A
checked ok
checked ok
checked ok

Checked Ok

2
Various

mix pump (See F.1.2)

100 hp
No
See D.2.3
1
Varco/ Bowl No.1
11 3/4 - 13 3/8

1
Varco/ Bowl No.2
9 5/8 - 10 3/4

4
Varco/ Bowl No.3
2 3/4 - 8 5/8
N/A
2
10,000
2"
No
No
3 (1 Direct Reading & 2 sensors to Swaco panel and
rig sense)

Proximity Sensor

300 rpm Driller Consol's Indicator

60,000 lb.f Driller Consol's Indicator

Proximity Sensor

300 rpm

MD TOTCO
0-60,000 lb.f on Driller Console / 0-40,000 lb.f on
MD Totco Torque indicator Gauge

yes
Rig sense
N/A

yes
1
OTECO
0-10,000 psi

1
OTECO
0-10,000 psi
Yes
NO
Driller Cabinet
Monkey board
Fedral Signal Corporation

In bad Condition
No

2
GAITRONICS
No
NO
Yes

Yes ( Not Working)

Yes ( Not Working)


Young Wind Tracker

RITCHIE
control room
1
JORDAN/406-121.5 MHz
Port Side 4th level

2
Sailor RT2048

Radio room
1 Inmarsat devise ( 1 thuraya satellite phone)
N/A
5
HAWS

Rig floor, shale shaker, Mud oits, sackroom,


1
2
HARRISBURG

500 US gpm

yes

yes
29

2
50 f
ANSUL
200 Gal. (Nominal Capacity) Manufacturer Manual
Foam Concentrate AFFF 3% F-15

4"
HeliDeck

See L.3.5
Exist (not rated to length)

Fassmer CLR
2
60/each
Port & STBD
Yes
yes

yes
Viking (David lifable)
4
25/each
yes
frwd port & STBD

Zodiac

Comar Embarkation
2

Вам также может понравиться