Вы находитесь на странице: 1из 31

GPSA Engineering Data Book 14th Edition

REVISION DATE REASON(S) FOR REVISION


0 4/1/2017 Initial release
GPSA Engineering Data Book 14th Edition

FIG. 25-1
Nomenclature
Ki = equilibrium ratio, yi/xi P* =
L = ratio of moles of liquid to moles of total mixture R =

N = mole fraction in the total mixture or system T =


ω = acentric factor V =

P = absolute pressure, psia xi =

Pk = convergence pressure, psia yi =

Subscripts i =

KEY
= Example calculation from the book
= Application worksheet for user to fill out
= Numbers that must be filled in according to the user's data and specific situation (also includes numbers from graphs and ch

NOTE
These charts show the vapor-liquid equilibrium ratio, Ki, for use in example and approximate flash calculations. The charts
not give accurate answers, particularly in the case of nitrogen. They are included only for illustrative purposes and to suppo
example flash calculations and quick estimation of K-values in other hand calculations. These charts should not be used in
design calculations.
Previous editions of this data book presented extensive sets of K-data based upon the GPA Convergence Pressure, Pk, metho
A component’s K-data is a strong function of temperature and pressure and a weaker function of composition. The converge
pressure method recognizes composition effects in predicting K-data. The convergence pressure technique can be used in ha
calculations, and it is still available as computer correlations for K-data prediction.
Availability of computers, coupled with the more refined Kvalue correlations in modern process simulators, has made the
previous GPA convergence pressure charts outdated. Complete sets of these charts are available from GPA as a Technical P
TP-22.
vapor pressure, psia
universal gas constant,
(psia · cu ft)/(lbmole · °R)
temperature, °R or °F
ratio of moles of vapor to moles of total pressure

mole fraction of component I in the liquid phase

mole fraction of component I in the vapor phase

component

ecific situation (also includes numbers from graphs and charts)

in example and approximate flash calculations. The charts do


hey are included only for illustrative purposes and to support
her hand calculations. These charts should not be used in

data based upon the GPA Convergence Pressure, Pk, method.


ssure and a weaker function of composition. The convergence
ata. The convergence pressure technique can be used in hand
K-data prediction.
orrelations in modern process simulators, has made the
ts of these charts are available from GPA as a Technical Paper,
GPSA Engineering Data Book 14th Edition

Example 25-1 -- Binary System Calculation

A mixture is put under the following conditions:

Component 1 Methane = 60 lb moles


Component 2 Ethane = 40 lb moles
Temperature = -125 °F
Pressure = 50 psia

How many moles are in the vapor phase and how many in the liquid phase?

K1 = 10 Page 25-16
K2 = 0.35 Page 25-16

From the definition of Ki-value, Eq. 25-1:


K1 = y1/x1 = 10
K2 = y2/x2 = 0.35
For a binary system, x1 + x2 = 1 and y1 + y2 = 1, so
(1-y1)/(1-x1) = 0.35 and (1-y2)/(1-x2) = 10
Solving the above equations simultaneously:
x1 = 0.0674
y1 = 0.674
x2 = 0.9326
y2 = 0.326
To find the amount of vapor in the mixture, let v denote the number of lb moles of vapor.
Summing the moles of Methane in each phase gives:
S lb moles for component 1 + 2 = 100 lb moles
x1 + y1 = 60 lb moles
(y1 * v) + (x1 * [100 - v]) = 60 lb moles
v = 87.9
The mixture consists of:
Vapor = 87.9 lb moles
Liquid = 12.1 lb moles

The sample calculations, equations and spreadsheets presented herein were developed using examples published in the Engine
While every effort has been made to present accurate and reliable technical information and calculation spreadsheets based on
The Calculation Spreadsheets are provided without warranty of any kind including warranties of accuracy or reasonableness of
In no event will the GPA or GPSA and their members be liable for any damages whatsoever (including without limitation, thos
These calculation spreadsheets are provided to provide an “Operational level” of accuracy calculation based on rather broad as
Application 25-1 -- Binary System Calculation

A mixture is put under the following conditions:

Component 1 Methane = 60 lb moles


Component 2 Ethane = 40 lb moles
Temperature = -125 °F
Pressure = 50 psia

How many moles are in the vapor phase and how many in the liquid phase?

K1 = 10 Page 25-16
K2 = 0.35 Page 25-16

From the definition of Ki-value, Eq. 25-1:


K1 = y1/x1 = 10
K2 = y2/x2 = 0.35
For a binary system, x1 + x2 = 1 and y1 + y2 = 1, so
(1-y1)/(1-x1) = 0.35 and (1-y2)/(1-x2) = 10
Solving the above equations simultaneously:
x1 = 0.0674
y1 = 0.674
x2 = 0.9326
y2 = 0.326
To find the amount of vapor in the mixture, let v denote the number of lb moles of vapor.
Summing the moles of Methane in each phase gives:
S lb moles for component 1 + 2 = 100 lb moles
x1 + y1 = 60 lb moles
(y1 * v) + (x1 * [100 - v]) = 60 lb moles
Therefore, v = 87.9
The mixture consists of:
Vapor = 87.9 lb moles
Liquid = 12.1 lb moles

examples published in the Engineering Data Book as published by the Gas Processor Suppliers Association as a service to the gas processin
calculation spreadsheets based on the GPSA Engineering Data Book sample calculations, the use of such information is voluntary and the G
s of accuracy or reasonableness of factual or scientific assumptions, studies or conclusions, or merchantability, fitness for a particular purpo
(including without limitation, those resulting from lost profits, lost data or business interruption) arising from the use, inability to, reference
lculation based on rather broad assumptions (including but not limited to: temperatures, pressures, compositions, imperial curves, site cond
n as a service to the gas processing industry. All information and calculation formulae has been compiled and edited in cooperation with G
nformation is voluntary and the GPA and GPSA do not guarantee the accuracy, completeness, efficacy, or timeliness of such information. R
bility, fitness for a particular purpose, or non-infringement of intellectual property.
om the use, inability to, reference to or reliance on the information in this Publication, whether based on warranty, contract, tort or any othe
sitions, imperial curves, site conditions etc) and do not replace detailed and accurate Design Engineering taking into account actual process
ted in cooperation with Gas Processors Association (GPA).
ess of such information. Reference herein to any specific commercial product, calculation method, process, or service by trade-name, trade
, contract, tort or any other legal theory and whether or not advised of the possibility of such damages.
nto account actual process conditions, fluid properties, equipment condition or fowling and actual control set-point dead-band limitations.
vice by trade-name, trademark, and service mark manufacturer or otherwise does not constitute or imply endorsement, recommendation or
t dead-band limitations.
ment, recommendation or favoring by the GPA and/or GPSA.
GPSA Engineering Data Book 14th Edition

Example 25-2 -- Flash Calculation

A typical high pressure separator gas is cooled to liquefy heavier hydrocarbons prior to cooling to a lower temperature where t
components would freeze out as solids.

Temperature = -125 °F
Pressure = 600 psia

What is the ratio of moles of liquid to the moles of the total mixture under these conditions?

Solution Steps

The feed gas composition is given in Column 1. The flash equation, 25-5, is solved for three estimated values of L as shown in
Columns 3, 4, and 5.
By plotting estimated values of L versus calculated Sum(xi), the correct value of L where Sum(xi) = 1.00 is L = 0.03. This sol
entered into Cell I17 and then whose solution is shown in columns 6 and 7. The gas composition is then calculated using yi =
Column 8.
This 'correct' value is used for purposes of illustration. It is not a completely converged solution, for xi = 1.00048 and yi = 0.9
columns 7 and 8. This error may be too large for some applications.
[Note: The trial values used for L should bracket S(Ni/(L+VKi) [Calculated Total] = 1.00. If not, chose different values. When
have three acceptable values, please enter them in numerical order in Cells D20 - E20 in order to have unidirectional line in th
below. This will assist identifying the value of L where the line crosses S(xi) = 1.00.]

Column
1 2 3 4 5 6
Component Final value of L from plot
Feed Pk = Trial values of L (note: V + L = 1) =
below =
Composition
2000 0.02 0.04 0.06
L+VKi
Ni Ki Ni/(L+VKi) Ni/(L+VKi) Ni/(L+VKi)
C1 0.9010 3.7 0.24712 0.25084 0.25466 3.61900
CO2** 0.0106 1.23 0.00864 0.00867 0.00870 1.22472
C2 0.0499 0.41 0.11830 0.11508 0.11203 0.42770
C3 0.0187 0.082 0.18633 0.15751 0.13642 0.10954
iC4 0.0065 0.034 0.12191 0.08948 0.07068 0.06298
nC4 0.0045 0.023 0.10578 0.07249 0.05513 0.05231
iC5 0.0017 0.0085 0.06001 0.03530 0.02500 0.03825
nC5 0.0019 0.0058 0.07398 0.04170 0.02903 0.03563
C6 0.0029 0.0014 0.13569 0.07014 0.04730 0.03136
C7* 0.0023 0.00028 0.11344 0.05712 0.03817 0.03027
TOTALS 1.0000 1.17120 0.89833 0.77713
C7* 0.00042
C8 0.00014
* C7+ = average of nC7 + nC8 properties
** KCO2 = sq.rt (KC1 · KC2)
1.40000

1.20000

1.00000

Calculated Totals 0.80000

0.60000

0.40000

0.20000

0.00000
0.015 0.02 0.025 0.03 0.035 0.04 0.045 0.05 0.055 0.06 0.065
Trial Values of L

The sample calculations, equations and spreadsheets presented herein were developed using examples published in the Engine
While every effort has been made to present accurate and reliable technical information and calculation spreadsheets based on
The Calculation Spreadsheets are provided without warranty of any kind including warranties of accuracy or reasonableness of
In no event will the GPA or GPSA and their members be liable for any damages whatsoever (including without limitation, thos
These calculation spreadsheets are provided to provide an “Operational level” of accuracy calculation based on rather broad as
Application 25-2 -- Flash Calculation

ing to a lower temperature where these A typical high pressure separator gas is cooled to liquefy heavier hydrocarbons prior
components would freeze out as solids.

Temperature = -125
Pressure = 600

What is the ratio of moles of liquid to the moles of the total mixture under these cond

Solution Steps

e estimated values of L as shown in The feed gas composition is given in Column 1. The flash equation, 25-5, is solved fo
Columns 3, 4, and 5.
um(xi) = 1.00 is L = 0.03. This solution is By plotting estimated values of L versus calculated Sum(xi), the correct value of L w
sition is then calculated using yi = Kixi in entered into Cell I17 and then whose solution is shown in columns 6 and 7. The gas c
Column 8.
ution, for xi = 1.00048 and yi = 0.99999, This 'correct' value is used for purposes of illustration. It is not a completely converg
columns 7 and 8. This error may be too large for some applications.
f not, chose different values. When you [Note: The trial values used for L should bracket S(Ni/(L+VKi) [Calculated Total] = 1
der to have unidirectional line in the plot have three acceptable values, please enter them in numerical order in Cells D20 - E20
below. This will assist identifying the value of L where the line crosses S(xi) = 1.00.]

Column
7 8 1 2 3
Final value of L from plot Component
0.030 Feed Pk = Trial values of L (note: V + L = 1) =
below =
Composition
Liquid Vapor 2000 0.02
xi = Ni/
(L+VKi) yi Ni Ki Ni/(L+VKi)
0.24896 0.92117 C1 0.9010 3.7 0.24712
0.00866 0.01066 CO2** 0.0106 1.23 0.00864
0.11667 0.04783 C2 0.0499 0.41 0.11830
0.17071 0.01400 C3 0.0187 0.082 0.18633
0.10321 0.00351 iC4 0.0065 0.034 0.12191
0.08603 0.00198 nC4 0.0045 0.023 0.10578
0.04445 0.00038 iC5 0.0017 0.0085 0.06001
0.05333 0.00031 nC5 0.0019 0.0058 0.07398
0.09248 0.00013 C6 0.0029 0.0014 0.13569
0.07598 0.00002 C7* 0.0023 0.00028 0.11344
1.00048 0.99999 TOTALS 1.0000 1.17120
C7* 0.00042
C8 0.00014
* C7+ = average of nC7 + nC8 properties
** KCO2 = sq.rt (KC1 · KC2)

1.40000

1.20000

1.00000

Calculated Totals
0.80000

0.60000

0.40000

0.20000

0.00000
0.045 0.05 0.055 0.06 0.065
0.015 0.02 0.025 0.03 0.035
Trial Valu

examples published in the Engineering Data Book as published by the Gas Processor Suppliers Association as a service to the gas processi
calculation spreadsheets based on the GPSA Engineering Data Book sample calculations, the use of such information is voluntary and the G
es of accuracy or reasonableness of factual or scientific assumptions, studies or conclusions, or merchantability, fitness for a particular purp
(including without limitation, those resulting from lost profits, lost data or business interruption) arising from the use, inability to, referenc
alculation based on rather broad assumptions (including but not limited to: temperatures, pressures, compositions, imperial curves, site con
to liquefy heavier hydrocarbons prior to cooling to a lower temperature where these

°F
psia

s of the total mixture under these conditions?

1. The flash equation, 25-5, is solved for three estimated values of L as shown in

ated Sum(xi), the correct value of L where Sum(xi) = 1.00 is L = 0.03. This solution is
s shown in columns 6 and 7. The gas composition is then calculated using yi = Kixi in

tration. It is not a completely converged solution, for xi = 1.00048 and yi = 0.99999,


or some applications.
et S(Ni/(L+VKi) [Calculated Total] = 1.00. If not, chose different values. When you
in numerical order in Cells D20 - E20 in order to have unidirectional line in the plot
L where the line crosses S(xi) = 1.00.]

Column
4 5 6 7 8
Final value of L from plot
Trial values of L (note: V + L = 1) = 0.030
below =
0.04 0.06 Liquid Vapor
L+VKi xi = Ni/
Ni/(L+VKi) Ni/(L+VKi) (L+VKi) yi
0.25084 0.25466 3.61900 0.24896 0.92117
0.00867 0.00870 1.22472 0.00866 0.01066
0.11508 0.11203 0.42770 0.11667 0.04783
0.15751 0.13642 0.10954 0.17071 0.01400
0.08948 0.07068 0.06298 0.10321 0.00351
0.07249 0.05513 0.05231 0.08603 0.00198
0.03530 0.02500 0.03825 0.04445 0.00038
0.04170 0.02903 0.03563 0.05333 0.00031
0.07014 0.04730 0.03136 0.09248 0.00013
0.05712 0.03817 0.03027 0.07598 0.00002
0.89833 0.77713 1.00048 0.99999

1.40000

1.20000

1.00000

0.80000

0.60000

0.40000

0.20000

0.00000
0.015 0.02 0.025 0.03 0.035 0.04 0.045 0.05 0.055 0.06 0.065
Trial Values of L

ciation as a service to the gas processing industry. All information and calculation formulae has been compiled and edited in cooperation w
such information is voluntary and the GPA and GPSA do not guarantee the accuracy, completeness, efficacy, or timeliness of such informati
hantability, fitness for a particular purpose, or non-infringement of intellectual property.
ing from the use, inability to, reference to or reliance on the information in this Publication, whether based on warranty, contract, tort or an
ompositions, imperial curves, site conditions etc) and do not replace detailed and accurate Design Engineering taking into account actual pr
been compiled and edited in cooperation with Gas Processors Association (GPA).
s, efficacy, or timeliness of such information. Reference herein to any specific commercial product, calculation method, process, or service

her based on warranty, contract, tort or any other legal theory and whether or not advised of the possibility of such damages.
Engineering taking into account actual process conditions, fluid properties, equipment condition or fowling and actual control set-point de
method, process, or service by trade-name, trademark, and service mark manufacturer or otherwise does not constitute or imply endorseme

ch damages.
d actual control set-point dead-band limitations.
titute or imply endorsement, recommendation or favoring by the GPA and/or GPSA.
GPSA Engineering Data Book 14th Edition

Example 25-3 -- Dew Point Calculation Application 25-3 -- Dew Point Cal

A gas stream is being cooled in a heat exchanger. The initial conditions are: A gas stream is being cooled in a he

Temperature = 100 °F Temperature


Pressure = 800 psia Pressure

Find the temperature at which the gas starts to condense. (Dew Point) Find the temperature at which the g

Solution Steps Solution Steps

The equation for dew point conditions (SNi/Ki = 1.0) is solved for two The equation for dew point conditio
estimated dew point temperatures. By interpolation, the temperature at which estimated dew point temperatures.
Ni/Ki = 1.00 is estimated below. Ni/Ki = 1.00 is estimated below.

[Note: The trial values used for dew point temperature should bracket [Note: The trial values used for dew
S(Ni/Ki) = 1.00. If not, chose different values.] S(Ni/Ki) = 1.00. If not, chose diffe
Column
1 2 3 4 5
Feed P k
= 1000 P k
= 1000
-50 °F -40 °F
Ni Ki Ni/Ki Ki Ni/Ki
CH4 0.854 2.25 0.380 2.3 0.371 CH4
CO2* 0.051 0.787 0.065 0.844 0.060 CO2*
C2H6 0.063 0.275 0.229 0.31 0.203 C2H6
C3H8 0.032 0.092 0.348 0.105 0.305 C3H8
iC4
nC4
iC5
nC5
C6
C7+
S= 1.000 1.021 0.940 S=

* KCO2 = sq.rt. (KC1 · KC2) * KCO2 = sq.rt. (K

Linear interpolation: Tdew = -47.4 °F Linear interpolation: Tde


Note that the heaviest component is quite important in dew point calculations. Note that the heaviest component is
For more complex mixtures, the characterization of the heavy fraction as a For more complex mixtures, the cha
pseudocomponent such as hexane or octane will have a significant effect on pseudocomponent such as hexane o
dew point calculations. dew point calculations.

The sample calculations, equations and spreadsheets presented herein were developed using examples published in the Engine
While every effort has been made to present accurate and reliable technical information and calculation spreadsheets based on
The Calculation Spreadsheets are provided without warranty of any kind including warranties of accuracy or reasonableness of
In no event will the GPA or GPSA and their members be liable for any damages whatsoever (including without limitation, thos
These calculation spreadsheets are provided to provide an “Operational level” of accuracy calculation based on rather broad as
on 25-3 -- Dew Point Calculation

am is being cooled in a heat exchanger. The initial conditions are:

= 100 °F
= 800 psia

emperature at which the gas starts to condense. (Dew Point)

ion for dew point conditions (SNi/Ki = 1.0) is solved for two
dew point temperatures. By interpolation, the temperature at which
00 is estimated below.

e trial values used for dew point temperature should bracket


= 1.00. If not, chose different values.]
Column
1 2 3 4 5
Feed P k
= 1000 P k
= 1000
-50 °F -40 °F
Ni Ki Ni/Ki Ki Ni/Ki
0.854 2.25 0.380 2.3 0.371
0.051 0.787 0.065 0.844 0.060
0.063 0.275 0.229 0.31 0.203
0.032 0.092 0.348 0.105 0.305

1.000 1.021 0.940

* KCO2 = sq.rt. (KC1 · KC2)

Linear interpolation: Tdew = -47.4 °F


the heaviest component is quite important in dew point calculations.
complex mixtures, the characterization of the heavy fraction as a
mponent such as hexane or octane will have a significant effect on
calculations.

s published in the Engineering Data Book as published by the Gas Processor Suppliers Association as a service to the gas processing indust
on spreadsheets based on the GPSA Engineering Data Book sample calculations, the use of such information is voluntary and the GPA and
uracy or reasonableness of factual or scientific assumptions, studies or conclusions, or merchantability, fitness for a particular purpose, or no
ng without limitation, those resulting from lost profits, lost data or business interruption) arising from the use, inability to, reference to or re
n based on rather broad assumptions (including but not limited to: temperatures, pressures, compositions, imperial curves, site conditions et
to the gas processing industry. All information and calculation formulae has been compiled and edited in cooperation with Gas Processors A
voluntary and the GPA and GPSA do not guarantee the accuracy, completeness, efficacy, or timeliness of such information. Reference here
or a particular purpose, or non-infringement of intellectual property.
ability to, reference to or reliance on the information in this Publication, whether based on warranty, contract, tort or any other legal theory
ial curves, site conditions etc) and do not replace detailed and accurate Design Engineering taking into account actual process conditions, fl
tion with Gas Processors Association (GPA).
ormation. Reference herein to any specific commercial product, calculation method, process, or service by trade-name, trademark, and serv

or any other legal theory and whether or not advised of the possibility of such damages.
ual process conditions, fluid properties, equipment condition or fowling and actual control set-point dead-band limitations.
name, trademark, and service mark manufacturer or otherwise does not constitute or imply endorsement, recommendation or favoring by the
ndation or favoring by the GPA and/or GPSA.

Вам также может понравиться