KLINGERsil C4400

Premium quality non-asbestos material composed of fibres with heat resistance. Outstanding creep resistance at high

temperatures and high loads provides maximum safety, high torque retention and excellent sealing characteristics. Suitable for

use on water, gases, hydrocarbons, akalis and medium strength acids.

3XA Anti-stick coating on both sides aids flange seperation, reducing installation time. It also removes the need for application of

grease or sealants which may cause gasket failure.

Technical Data

Please note that these figures are provided as guidelines only. These limits do not necessarily operate together for all gasket

thicknesses and service conditions. Reference thickness 2.0 mm. All temperatures and pressures are dependent on chemical

compatiblity, refer to KLINGER chemical compatibility chart or KLINGERexpert PC design software.

Maximum Operating Temperature 400 °C

Maximum Operating Pressure 100 bar

Compressibility ASTM F36A 11 %

Recovery ASTM F36A (min) 55 %

KLINGER hot compression test 25 MPa 300°C

Thickness decrease 23°C 10 %

Thickness decrease 300°C 22 %

Tensile strength ASTM F152 across grain 15 MPa

Gas leakage DIN 3535/6 0.2 ml/min

Stress Relaxation BS7531 23 MPa

Stress Relaxation DIN 52913 (16h, 300°C) 25 MPa

Weight increase ASTM F146

ASTM Oil No. 3 (5h/150°C) 3 %

ASTM Fuel B (5h/23°C) 5 %

Thickness increase ASTM F146


ASTM Oil No. 1 (5h/150°C) 0-5 %

ASTM Oil No. 3 (5h/150°C) 0-5 %

ASTM Fuel A (5h/23°C) 0-5 %

ASTM Fuel B (5h/23°C) 0-5 %

Density 1.6 g/cm³

Note: Test standards used are universally accepted for testing non-asbestos materials.

APPROVALS

• Gas Supply - DVGW No. 88.01e052 (German Gas & Water Association)

• Potable Water - WRC (Water Research Council, UK)

• Oxygen Gas Approval (100bar/80°C) - BAM (German Federal Institute for Research & Testing)

• General Shipping - Lloyds (Germany)

• Drinking Water - KTW (Germany)

• Meets BS7531 Grade Y

KLINGER PT Diagram
Note: The KLINGER PT Diagram provides design

guidelines - not pressure / temperature limitations, refer

to KLINGER expert gasket design software.

1. Normally satisfactory for use providing chemical

compatibility has been confirmed.

2. Normally satisfactory for use (subject to chemical

compatibility) except in steam applications, which

should be referred to KLINGER for advice.

3. Refers to applications which fall into the "open

field", refer to KLINGER for advice.