Вы находитесь на странице: 1из 26

Directional Control Valve

Technical Information

powersolutions.danfoss.com
Directional Control Valves Technical Information: Contents

PRODUCT OVERVIEW Flexibility of design......................................................................................................................................... 3


Circuit options.................................................................................................................................................. 3
Capability........................................................................................................................................................... 3
Actuation options........................................................................................................................................... 3
Modular valves................................................................................................................................................. 4

FLUIDS AND FILTRATION


Fluids.................................................................................................................................................................... 5
Base stock and additives......................................................................................................................... 5
Viscosity......................................................................................................................................................... 5
Filtration........................................................................................................................................................ 5
Return line filtration.................................................................................................................................. 5
Cleanliness................................................................................................................................................... 5

CDS 60 AND 100 Specifications.................................................................................................................................................... 6


Typical performance...................................................................................................................................... 7
Inlet covers order code.................................................................................................................................. 8
Inlet porting and relief valve options...................................................................................................... 9
Mid-inlet flow dividers and combiners order code...........................................................................10
Mid-inlet flow dividers and combiners.................................................................................................11
Outlet covers order code............................................................................................................................12
Outlet porting and plug options.............................................................................................................13
Work section order code...................................................................................................................... 14-17
Circuit types....................................................................................................................................................18
Spool types......................................................................................................................................................19
Actuation options.................................................................................................................................. 20-21
Cabling and electrical options for actuator types G, H, and J.......................................................22
Actuation mounting side...........................................................................................................................22
Spool centering and detent options............................................................................................... 23-24
Auxiliary valves........................................................................................................................................ 25-26
Dimensions CDS 100....................................................................................................................................26
Dimensions CDS 60......................................................................................................................................27

APPENDIX 1 — ORDER Spool valve order form................................................................................................................................28


FORMS CDS60 and CDS100 specification worksheet......................................................................................28
CDS60 and CDS100 price worksheet.....................................................................................................28

2 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: Product overview

FLEXIBILITY OF DESIGN The Danfoss directional control valves are designed to give customer flexibility over a broad
range of flow and pressure capabilities. Actuator options include a range of levers, cable
actuators, hydraulic and pneumatic pilot controls, two-axis joysticks, and electrohydraulic
solenoids. Flow rates range from 0 to 100 l/min [26 US gal/min].

CIRCUIT OPTIONS • Parallel circuits


• Series circuits
• Tandem circuits
• Prioritay circuits
• Regenerative circuits
• Power beyond

CAPABILITY • Flow rates from 0 to 100 l/.min [26 US gal/min]


• System pressure up to 250 BAR
• Up to 12 work sections
• 12 cm³/min [0.7 in³/min] leakage

ACTUATION OPTIONS • Handles and levers


• Mechanical two-axis joystick
• Spool ends
• ElectroHydraulic Control (EHC) on/off solenoid
• Cable control
• Pneumatic pilot control
• Dual spool ends

3 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: Product overview

MODULAR VALVES
Valve l/min [US gal/min] Number
Circuit Page
model 20 [5] 40 [11] 60 [16] 80 [21] 100 [26] of Spools
Parallel
CDS-100 100 [26] 1 to 12 Tandem
Series
Parallel
CDS-60 60 [16] 1 to 12 Tandem
Series

Indicates Maximum Working Pressure Rated At 210 bar [3000 psi]

4 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: Fluids and Filtration

FLUIDS Hydraulic fluid performs three basic functions in a hydraulic system: It transfers energy,
lubricates moving components, and transports heat and contaminants out of the system.

Base stock and additives


Danfoss valves are designed to operate with mineral-based fluids containing oxidation, rust,
and foam inhibitors, compatible with fluoroelastomer seals. Consult your fluid supplier for
information on seal compatibility.

Viscosity
Viscosity is the most important property of a hydraulic fluid. It is a measurement of how the
fluid resists flow. Low viscosity fluids increase internal leakage; high viscosity fluids increase
pressure drop through the valve. Use a fluid that meets the viscosity limits published in this
catalog. For specific requirements, see technical data in each section.

Temperature
Temperature affects a fluid’s viscosity. Higher temperature fluid has lower viscosity.
Operating at excessive temperatures may have other detrimental effects on your hydraulic
fluid. Design your hydraulic system to operate within the specified temperature range.
Specific requirements are published in each section.

For more information


For more information on hydraulic fluid selection refer to Hydraulic Fluids and Lubricants
Technical Information, Danfoss publication 520L0463.

FILTRATION
Effective filtration is critical to a hydraulic system’s performance and working life. Employ
system filtration capable of meeting the published requirements in each valve section. Be
aware that other components in the system may have more stringent requirements. Design
your filtration system to satisfy the requirements of the most sensitive component.

Return line filtration


Return line filtration is generally adequate for Danfoss valves. We recommend a 10 micron
nominal (20 micron absolute) or finer filter. Insure the filter in your system is properly sized
and maintained. To facilitate proper filter maintenance, use a pressure gauge or other
indicator to signal when it is necessary to change the filter. Never allow filter to reach its
bypass condition. Follow the filter manufacturer’s maintenance recommendations.

Cleanliness
Hydraulic system contamination must not exceed the limits published for each valve. Limits
are specified per ISO 4406 (1999). When measuring system contamination, calibrate test
equipment in accordance with the ACFTD method.

For more information


For more information on system filtration, refer to Design Guidelines for hydraulic fluid
cleanliness, Danfoss publication 520L0467.

5 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

CDS 100

CDS 60

SPECIFICATIONS Maximum flow (CDS 100) 100 l/min [26.4 US gal/min]


Maximum flow (CDS 60) 60 l/min [15.8 US gal/min]
Work pressure 210 bar [3050 psi]
Maximum pressure 250 bar [3625 psi]
Maximum pressure (outlet section) 40 bar [580 psi]
Temperature range -40º to 80º C [-40 to 176º F]
Recommended fluid type Mineral based hydraulic oil
Recommended viscosity 26-55 mm²/sec (cSt) [123-255 SUS]
Minimum fluid cleanliness (per ISO 4406) 19/16

6 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

TYPICAL PERFORMANCE Pressure vs. flow curves for main relief valve
250
Based on oil temperature [3625]
of 45°–50°C [113°–122° F]. 200
Viscosity 32 mm²/sec [2900]

Pressure - bar [psi]


(cSt) [151 SUS]. CDS 150
spool leakage (standard) [2176]
at 70 bar [1015 psi],
50°C [122°F], ISO VG46: 100
[1450]
10 cm³/min [0.61 in³/min]
50
[725]

0
0 10 20 30 40 50 60 70 80 90 100
[2.6] [5.3] [7.9] [10] [13] [16] [19] [21] [24] [26]
Flow - l/min [US gal/min]

Pressure drop (P-T) CDS 60 Pressure drop (P-T) CDS 100

12 sections
16 12 sections 16
[232] [232] 11 sections
11 sections
10 sections
14 10 sections 14
[203] [203]
9 sections
9 sections
8 sections
12 8 sections 12
[174] [174]
7 sections
7 sections 6 sections
10 10
Pressure - bar [psi]
Pressure - bar [psi]

[145] [145] 5 sections


6 sections

8 5 sections 8 4 sections
[116] [116]
4 sections

6 6 3 sections
[87] 3 sections [87]

2 sections
4 4 2 sections
[58] 1 sections [58]

1 sections
2 2
[29] [29]

0 0
0 10 20 30 40 50 60 0 10 20 30 40 50 60 70 80 90 100
[2.6] [5.3] [7.9] [10] [13] [16] [2.6] [5.3] [7.9] [10] [13] [16] [19] [21] [24] [26]
Flow - l/min [US gal/min] Flow - l/min [US gal/min]

7 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

INLET COVERS ORDER


CODE Inlet covers order code (example)
E60 A C 2 140/40*

Models
Code Description
E100 CDS100
E60 CDS60

Port locations
Code Description
A Top port
B Side port, top port plugged
C Top port, with side gauge port (9/16-18UNF)
D Top inlet and outlet ports (use H, I, J on outlet)

Main relief valves


Code Description
A No valve, with plastic plug
B No valve, with special plug
C Valve, with direct valve and external adjustment
D Valve, with direct valve and internal adjustment
E* Valve, pilot operated and external adjustment
* on request

Port types
Code 1 2 3 4 5 7 8 X
SAE - ORB BSP - Parallel Metric - ISO 6149

Special porting, specify


Threads #8 #10 #12
3/8 -19 1/2 -14 M18x1.5 M22x1.5
3/4 -16UNF 7/8 -14UNF 1 1/16-12UNF
Inlet
Model outlet   m m
CDS100 Section   m m
Inlet
Model outlet   m m m m
CDS60 Section   m m m m

available
m on request

8 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

INLET PORTING AND Inlet covers order code (example)


RELIEF VALVE OPTIONS E60 A C 2 140/40*

Port location

D* Top inlet and outlet (use with H,I,J, and L outlet covers)
A Top inlet
C Top inlet, gauge port side (9/16 - 18 UNF)
E100 inlet cover
A Shipping Plug

B Side inlet
(top plugged)
B
h1 in

P T

11
[0.43]

C
h 1 in h 7/8 h 7/16

67
[2.64]
max

D
h1 in

E60 inlet cover

47
[1.85]

E* Drawing

P101 798
* On request
mm [in]

9 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

OUTLET COVERS ORDER


CODE Outlet covers order code (example)
S60 A 2

Models
Code Description
S100 CDS 100
S60 CDS 60

Ports
Code Description
A Top outlet
B Side outlet, top plugged
C Side outlet for power beyond (top to tank)
D Top outlet (with closed bypass)
E Top outlet (for electrical control)
F Top outlet (for electrical control, with power beyond)
G Side outlet (for electrical control, top plugged)
H* Top plugged
I* Top plugged, use with power beyond
J* Top plugged for electrical control
L* Top plugged for electrical control, use with power beyond
* On request ( use D on inlet)

Port types
Code 1 2 3 4 5 7 8 X
SAE - ORB BSP - Parallel Metric - ISO 6149
Threads

Special porting,
#8 #10 #12
3/8 -19 1/2 -14 M18x1.5 M22x1.5
3/4 -16UNF 7/8 -14UNF 1 1/16-12UNF

specify
Model
outlet   m m
CDS100
Model
outlet   m m m m
CDS60
available
m on request

10 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

OUTLET PORTING AND Outlet covers order code (example)


PLUG OPTIONS S60 A 2

C T

S100 outlet cover Bypass PB


Pressure
Outlet

H** Top plugged


A Top outlet (side plugged) I T

Bypass PB
Pressure
Outlet 30
[1.18]

D*
T

Bypass
Pressure
Outlet

25
[0.98]

B Side outlet (top plugged) E T

Bypass
Pressure
Outlet

J T

Bypass
Pressure
30
Outlet
[1.18]

F T

Bypass PB
Pressure
Outlet
S60 outlet cover
L T

Bypass PB
Pressure CDS 60 30.5
Outlet [1.20]
CDS 100 32
[1.25]

G T

Bypass PB
Pressure
Outlet

CDS 60 30.5
[1.20]
CDS 100 32
[1.25]
P101 799E
*Typically used for high pressure standby.
** On request
mm [in]

11 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

WORK SECTION ORDER CODE Work section order code (example)


A100 1 A E 2 A 1 A B A100 140/40*
Model
A100 CDS 100 body for supporting valves
B100 CDS 100 normal body (no valves) See cabling and
A60 CDS 60 body for supporting valves electrical options,
B60 CDS 60 normal body (no valves)
page 22.
Circuit types, page 15
1 Parallel (no priority)
2* Tandem (priority)
3* Series (no priority)
Spool types, page 16
A 4-way, closed center
B 4-way, open center
C 4-way, closed center, port A plugged
D 4-way, closed center, port B plugged
E 3-way, closed center, port A plugged
F 3-way, closed center, port B plugged
G 4-way, open center, port A plugged
H 4-way, open center, port B plugged
I Float-spool in (use centering option J )
J Float-spool out (use centering option J)
Spool actuation, pages 17–18
A No extension
B Female spool end + Clevis
C Male spool end + Tang
D With support (no lever)
E With lever
F Pneumatic (use centering option A)
G Cable with lever
H Cable with joystick (use A for the adjacent body)
I/M With mechanical joystick (use A for the adjacent body)
J Electrical
R Female spool end
S Male spool end
T Female Spool end with adjust
Spool actuation mounting side, page 20
1 Actuator mounted on A port side
2 Actuator mounted on B port side
3 Electrical A and B (use L centering type)
* On request

12 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

WORK SECTION ORDER CODE (continued) Work section order code (example)
A100 1 A E 2 A 1 A B A100 140/40*

Spool centering and detents, page 20-21


A Spring centered
B 3 position detent
C Spring centered, detent in A
D Spring centered, detent in B
E Spring centered, detent in A and B
F Spring centered, hydraulic kickout
H Spring centered, female extension
I Spring centered, male extension
J Spring centered, detent in float: use for floatation spool
L Spring centered, use for electrical command
N 2-position detent, spool in
O 2-position detent, spool out
P* With switch, activates spool in
Q* With switch, activates spool in and out
R* With switch, activates two motors

* on request

Port types
Code 1 2 3 4 5 7 8 X
SAE - ORB BSP - Parallel Metric - ISO 6149
Threads

Special porting,
#8 #10 #12
3/8 -19 1/2 -14 M18x1.5 M22x1.5
3/4 -16UNF 7/8 -14UNF 1 1/16-12UNF

specify
Model
Section   m m
CDS100
Model
Section   m m m
CDS60
available
m on request
Auxiliary valves, page 22-23
A Plug
B Direct relief with external adjustment (except electrical actuation)
C Direct relief with internal adjustment
Work port side A
D Pilot check valve
E* Flow control valve (Except electrical actuation)
Work port side B
F Anti-cavitation
Direct relief with anti-cavitation and external adjustment
G
(except electrical actuation)
I Direct relief with anti-cavitation and internal adjustment (electrical only)
J Plug, for 3-way spools
K Plug, for valves D and E
For valves B, C, G, and I, specify pressure and flow
Example: B(140/40) Pressure 140 bar flow 40 l/min
* On request

13 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

ACTINGS AND CENTERING COMBINATIONS AVAILABLE

Actings
A B C D E F G H I/M J

A • • • • • • • • •
B • • • • • • • •
C • • • • • • • •
D • • • • • • • •
E • • • • • • • •
Centerings

F
• • • • • • • •
G • • • • • • • • •
H • • • • • • • •
I • • • • • • • • •
J • • • • • • • •
L

N • • • • • • • •
O • • • • • • • •
P
• • • • • • • • •
Q
• • • • • • • • •
R • • • • • • • • •
 available

14 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

CIRCUIT TYPES Work section order code (example)


A100 1 A E 2 A 1 A B A100 140/40*

1 Parallel circuit (no priority)


P A B A B T

Bypass

P101 696
Pressure

Inlet Work sections Outlet


When two or more sections operate simultaneously, flow favors the lowest pressure.

2 Tandem circuit (priority)*


P A B A B T

Bypass

P101 697
Pressure

Inlet Work sections Outlet

When two or more sections operate simultaneously, only the section closest to the inlet receives flow.

3 Series circuit (no priority)*


T P A B A B T

Bypass
P101 698

Inlet and Outlet Work Sections Outlet


When two or more sections operate simultaneously, the section closest to the inlet receives flow. Return flow
feeds the sections downstream.
* on request

15 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

SPOOL TYPES Work section order code (example)


A100 1 A E 2 A 1 A B A100 140/40*
Standard central body
Bypass core
Ref. Description Symbol
A 4-way closed center A B

P T

B 4-way open center


A B

P101 743

Tank (x2) Pressure core P T

C 4-way closed center


port A plugged A B
Pump load check
standard on all bodies

P T

D 4-way closed center


A B
port B plugged

P T

E 3-way closed center


A B
port A plugged

Central body for use with auxiliary valves P T

F 3-way closed center


A B
port B plugged

P T

G 4-way open center


A B
port A plugged

P T

H 4-way open center


A B
port B plugged

P T

I Float spool in (inner


A B
inverter)
Pump load check
standard on all bodies
P T

J Float spool out (outer


A B
inverter)

P T

16 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

ACTUATION OPTIONS
Work section order code (example)
A100 1 A E 2 A 1 A B A100 140/40*

30 CDS 60
A Without spool end B Female spool end (clevis) [1.18]
34
[1.34] CDS 100
8
[0.31] CDS 100 6.4
CDS 60
6.5 [0.25]
CDS 60
[0.26] 8.4
CDS 100
[0.33]

M8 x 1.25

M10 x 1.5
F
ø8
[0.31]

D With support
66
CDS 60 [2.60]
70
CDS 100 [2.76]
C Male spool end (tang)
M10 x 1.5
30
[1.18] CDS 60
34
[1.34] CDS 100

8.3
[0.33]

M
F Pneumatic
ø8 50
[0.31] [1.97]
1/8" NPT (2x)

E With lever

113
[4.45]
15º
15º
213
[8.39]
Minimum air pressure CDS 60: 5 bar [73 psi]
Minimum air pressure CDS 100: 8 bar [116 psi]
Maximum air pressure: 12 bar [174 psi]

mm [in] * Default relief setting if not specified

17 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

ACTUATION OPTIONS (continued) Work section order code (example)


A100 1 A E 2 A 1 A B A100 140/40*

G Cable with lever** H Cable with joystick**


A*

26 ø6
[1.02] [0.24]

280
[11.02]

7
[0.28]
7 30º 30º
[0.28] 50
[1.97]
157 395
[6.18] 25° 25°
[15.55]

48
[1.89]

40 118.5
[1.57] [4.66] 70
50 Ø [2.76]
[1.97] 97
[3.82]

I/M Mechanical joystick 2


P101 779 I
1 1
307
[12.09] 2
15º

2
M
1
2
15º

83
[3.27]
117
**See cabling and electrical
J Electrical**
[4.61]
(Ref.) (Ref.) DIN 43650 options, page 20.
Flying leads Standard sections cannot be
converted to electrical due to
12VCC 12VCC
internal pilot.
90 96
Minimum pilot pressure to
[3.54]
1.5m
[5 ft]
24VCC 24VCC
[3.78] actuate: 35 bar [500 psi]
(Ref.) (Ref.)

Manual override

P101781a

mm [in]

18 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

CABLING AND ELECTRICAL


OPTIONS FOR ACTUATOR
TYPES G, H, AND J Work section order code (example)
A100 1 A E 2 A 1 A B A100 140/40*

G: Flexible cable and lock options for spool control lever


A B C
Lever lock options Without lock Lock in A and/or B Lock in central position
Standard cables 100 - 125 - 150 - 175 - 200- 250 - 275- 300 - 325 - 350 - 400 - 450 - 500 cm (other: consult)
Example: how to order A60 - 1AG2A1 - AB - A100 - 140/40 (lever without lock, 100 cm cable)

H: Flexible cable and handle options controls for joystick


A
Joystick handle options Without switches
Standard cables 100 - 125 - 150 - 175 - 200 - 250 - 275 - 300 - 325 - 350 - 400 - 450 - 500 cm (other: consult)
Example: how to order A60 - 1AH2A1 - AB - A100 - 140/40 (handle without switches, 100 cm cable)

J: Electrical spool voltage and termination options


12 VDC - DIN 43650 24 VDC - DIN 43650
Voltage A 12 VDC -lead wires B 24 VDC - lead wires E F
conn. conn.
Example: how to order A60 - 1AJ3L1 - AC - A 140/40 (12 VDC coil with lead wires)

Force requirements Electrical specifications


kgf [lbf ] CDS 60 CDS 100 Voltage Amperage (A) Resistance (Ω)
Push/pull 2 [4.4] 3.5 [7.7] 12 VDC 1.75 6.85
min. 24 VDC 0.88 27
Max. tension 250 [551] 250 [551] Power: 21 W

ACTUATION MOUNTING 1 Actuation on A port side (RH inlet shown) 2 Actuation on B port side (LH inlet shown)
SIDE

CDS100 CDS60

A A A A T
B B P
P B B
T A A P B B T
P101 796
P101 822

CDS100 CDS60

19 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

SPOOL CENTERING AND DETENT OPTIONS Work section order code (example)
A100 1 A E 2 A 1 A B A100 140/40*

A Spring centered B 3 position detent C Spring center in, detent out


32 32 56
[1.25] CDS 60 [1.25] CDS 60 [2.20]
CDS 60
40 40 73
[1.57] CDS 100 [1.57] CDS 100 [2.87] CDS 100

Spring force
CDS 60: 145-155 N [32-35 lbf ]
CDS 100: 240-245 N [54-55 lbf ]

D Spring center out, detent in E Spring centered, detent in A and B F Spring centered, hydraulic kickout
56 56 92
CDS 60
[2.20] [2.20]
CDS 60 [3.62] CDS 60
73 73 96
[2.87] CDS 100 [2.87] CDS 100 [3.78] CDS 100

Note: Unlock body section


required for use with hydraulic
unlock kit.

H Spring centered, female extension I Spring centered, male extension


88±5 88±5
[3.46±0.2] CDS 60 [3.46±0.2] CDS 60
93 ±5 93 ±5
[3.66± 0.2] CDS 100 [3.66± 0.2] CDS 100

Ø 8 8
[0.31] Ø
[0.31]

CDS 60
6.4
[0.251]
8.4
[0.331] 20.5 8.3 20
CDS 100 [0.81] [0.33] [0.79]

J Spring centered, floatation spool Note: Float body section required

65 82 CDS 60
CDS 60
[2.56] [3.23]
78 CDS 100 10 CDS 60 101 CDS 100
[3.07] [0.39] [3.97]
12.5 CDS 100
[0.49]

Float in Float out


mm [in]

* Default relief setting if not specified

20 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

SPOOL CENTERING AND DETENT OPTIONS (continued) Work section order code (example)
A100 1 A E 2 A 1 A B A100 140/40*

N Two-position detent: O Two-position detent:


neutral and spool in neutral and spool out

32 32
[1.26] CDS 60 [1.26] CDS 60
40 40
[1.57] CDS 100 [1.57] CDS 100

P* Spring centered with switch: Q* Spring centered with switch: R* Spring centered with switch:
activates on spool in activates on spool in and out activates two motors

CDS 60 32
[1.26]
CDS 100 40
32 CDS 60 [1.57]
[1.26]
6.5 [0.26] CDS 60
40 CDS 100
CDS 60 CDS 60 8.0 [0.32] CDS 100
6.5 [0.26] [1.57]
6.5 [0.26]
8.0 [0.32] 8.0 [0.32]
CDS 100 CDS 100

P106 330E
*on request

21 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

AUXILIARY VALVES Work section order code (example)


A100 1 A E 2 A 1 A B A100 140/40*

J 11
[0.43]
A 11
[0.43]
K 10
[0.39]

1 in 1 in 1 in
For 3 ways spools. For valves B, C, F, G, and I For valves D and E.

B 1 in 11/16 7/16

T P

67
[2.64]
Max

C 1 in

47
[1.85] Standard
29 Short version
[1.14] (use with electrical
Central body for use with auxiliary valves actuation)

D 1 in

16
[0.63]

E* 1 in 7/8
5/8

62 CDS 60
[2.44] Knob
Max

F 1 in

12
[0.47]

G 1 in 11/16 7/16

70
[2.76]
Max

I 1 in

P101 746E
29
mm [in] [1.14]

* on request

22 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

AUXILIARY VALVES (continued) Work section order code (example)


A100 1 A E 2 A 1 A B A100 140/40*

Auxiliary valves compatibility


A B C D E F G I J K
A    — —    — —

B    — —   —  —

C    — —     —

D — — —  — — — — — 

E — — — —  — — — — 

F    — —     —

G    — —   —  —

I  —  — —  —   —

J —   — —    — —

K — — —   — — — — 

— Not compatible  Compatible


 Compatible (EXCEPT electrical)  Compatible (ONLY electrical)

DIMENSIONS CDS 100


Y 152
[5.98]

30 46 82
[1.18] [1.81] [3.23]
46
[1.81]

142
[5.59]
38
[1.49]
100
[3.94]

25 25 127
15
[0.98] [0.98] [5.00]
[0.59]
X

10
Reference dimensions
[0.39] Number of
X Y
sections
R 5.5 1 95 [3.74] 137 [5.39]
[0.22]
A A 2 139 [5.47] 181 [7.13]
3 184 [7.24] 226 [8.89]
4 229 [9.02] 270 [10.63]
t 27 N•m 5 273 [10.75] 314 [12.36]
20 lbf•ft
6 318 [12.52] 359 [14.13]
P B B T
7 362 [14.25] 403 [15.87]
8 406 [15.98] 448 [17.64]
9 451 [17.76] 492 [19.37]
10 495 [19.49] 537 [21.14]
11 540 [21.26] 581 [22.87]
12 584 [22.99] 626 [24.65]

44.5 mm [in]
[1.75]

23 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Directional Control Valves Technical Information: CDS 60 and 100

DIMENSIONS CDS 60
120
[4.72]

Y 56 74*
[2.20] [2.91]
24
[0.94]
38 38
[1.50] [1.50]

119
[4.69]

82
[3.23]
32
[1.26]

14
[0.55] 98
[3.86]

18 18
[0.71] [0.71]
Reference dimensions
X
Number of
X Y
sections
1 72 [2.83] 112 [4.41]
2 108 [4.25] 148 [5.83]
3 144 [5.67] 184 [7.42]
A A 4 180 [7.09] 220 [8.66]
T
5 216 [8.50] 256 [10.08]
28.5
6 252 [9.92] 292 [11.50]
[1.12] 7 288 [11.34] 328 [12.91]
26 P 8 324 [12.76] 364 [14.33]
B B
[1.02] 9 360 [14.17] 400 [15.75]
t 18 N•m
13 lbf•ft 10 396 [15.59] 436 [17.17]
11 432 [17.01] 472 [18.58]
r. 4.5
[0.18] 12 468 [18.43] 508 [20.00]

13
[0.51]

P101 795
36
[1.42]

Mounting requirements

A
B

77 78

P106 331E
Flatness 0.5-0.8 [0.02 to 0.03] max Flatness 0.5-0.8 [0.02 to 0.03] max

24 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101


Control No.
Directional Control Valves CDS60 and CDS100
Subsidiary/Dealer
Specification Order Form
Customer Application

25 | © Danfoss | March 2016


Inlet Section Paint Outlet Section
Model Model Port Main Threads Port Side Port Side None Model Model Size Ports Threads
Side Size relief Pressure Flow Options
Valves Black Primer
Black Paint

Work Sections
CDS60 AND CDS100 SPECIFICATION WORKSHEET

Cable or Cable “B” Port


Spool “A” Port Side “B” Port
Work Model Circuit Spool Spool Center Aux Valves Aux Valves Electrical Length “A” Port Side Side
Model Control Threads Pressure Side Flow (l/
section Size Type Types Controls Type “A” “B” Control Centi- Flow (l/min) Pressure
Side (Bar) min)
Options meters (Bar)

1st
2nd
3rd
4th
5th
Directional Control Valves Technical Information: Appendix 1 - Order forms

6th
7th
8th
9th
10th
11th
12th
Number of sections =

Price US $: Delivery: Date:

520L0564 | BC00000105en-US0101
Danfoss Mobile Power and Control Systems
OUR PRODUCTS – Market Leaders Worldwide

Danfoss is a comprehensive supplier providing complete ­systems


Hydrostatic transmissions to the global mobile market.
Hydraulic power steering Danfoss serves markets such as agriculture, construction, road
Electric power steering building, material handling, municipal, forestry, turf care, and many
others.
Electrohydraulic power steering
We offer our customers optimum solutions for their needs and
Closed and open circuit axial piston
develop new products and systems in close cooperation and
pumps and motors partner­ship with them.
Gear pumps and motors
Danfoss specializes in integrating a full range of system
Bent axis motors ­components to provide vehicle designers with the most advanced
Orbital motors total system design.

Transit mixer drives Danfoss provides comprehensive worldwide service for its
products through an extensive network of Global Service Partners
Planetary compact gears strategically located in all parts of the world.
Proportional valves
Directional spool valves
Cartridge valves
Local address:
Hydraulic integrated circuits
Hydrostatic transaxles
Integrated systems
Fan drive systems
Electrohydraulics
Microcontrollers and software
Danfoss (US) Company Danfoss ApS
Electric motors and inverters
2800 East 13th Street DK-6430 Nordborg, Denmark
Joysticks and control handles Ames, IA 50010, USA Phone: +45 7488 4444
Phone: +1 515 239-6000 Fax: +45 7488 4400
Displays Fax: +1 515 239-6618

Sensors Danfoss GmbH & Co. OHG Danfoss-Daikin LTD


Postfach 2460, D-24531 Neumünster Sannomiya Grand Bldg. 8F
Krokamp 35, D-24539 Neumünster, Germany 2-2-21 Isogami-dori, Chuo-ku
Phone: +49 4321 871-0 Kobe, Hyogo 651-0086, Japan
Fax: +49 4321 871 122 Phone: +81 78 231 5001
Fax: +81 78 231 5004

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are registered trademarks of Danfoss A/S. All rights reserved.

26 | © Danfoss | March 2016 520L0564 | BC00000105en-US0101

Вам также может понравиться