ANNEX - 1A

BILL OF QUANTITY AND PRICE SCHEDULE FOR SUPPLY OF HT, LT POWER CABLES, CONTROL CABLES AND
INSTRUMENTATION CABLES

UMC Updated
Sl. No. Item Description Unit RMH
NO. RMH

(1) (2) (3)

HT CABLES

1 11/11kV (UE) grade as per IS 7098-Pt II/1985,


stranded Aluminium conductor as per IS:8130-1984,
conductor screening by extruded semi-conductor
compound, XLPE insulated as per IS 7098-Pt-II/1985,
insulation screening by copper tape,
extruded PVC inner and outer sheathed as per
IS:5831-1984, aluminium wire armoured as per
IS:3975-1999, 1-Core, of following sizes. (copper tape
screen and armour together shall be able to carry 2000
A for 3 Sec E/F current without exceeding 200deg.
Centegrade temperature rise)

i. 300 sq. mm. M

ii. 240 sq. mm. M

2 11kV(E)/6.6kV(UE) grade as per IS 7098-Pt II/1985,


stranded Aluminium conductor as per IS:8130-1984,
conductor screening by extruded semi-conductor
compound, XLPE insulated, insulation screening by
copper tape, extruded PVC inner and
outer sheathed as per IS:5831-1984,
hard drawn aluminium wire armoured as per
IS:3975-1999, 1-Core, of following sizes. (copper tape
screen and armour together shall be able to carry 2000
A for 3 Sec E/F current without exceeding 200deg.
Centegrade temperature rise)

i. 300 sq. mm. M

ii. 240 sq. mm. M

3 11kV(E)/6.6kV(UE) grade as per IS 7098-Pt II/1985,


stranded Aluminium conductor as per IS:8130-1984,
conductor screening by extruded semi-conductor
compound, XLPE insulated, insulation screening by
copper tape for individual core, extruded
PVC inner and outer sheathed as per IS:5831-1984,
hard drawn galvanised steel strip armoured as per
IS:3975-1999, 3-Core (copper tape screen
and armour together shall be able to carry 2000
A for 3 Sec E/F current without exceeding 200deg.
Centegrade temperature rise)

i. 300 sq. mm. M 28000 35500

ii. 240 sq. mm. M

iii. 185 sq. mm. M

iv. 150 sq. mm. M

v. 120 sq mm M 7000 7750

vi. 70 sq mm M 25000 30000

4 11 KV (E)/6.6 KV (UE) grade as per IS 7098-Pt


II/1985, stranded Copper conductor as per
IS:8130-1984, conductor screening by extruded
semi-conductor compound, XLPE insulated, insulation
screening by extruded semiconducting compound and
copper tape, extruded PVC inner and outer sheathed
as per IS:5831-1984, aluminium wire armoured
as per IS:3975-1999, 1-Core, (copper tape
screen and armour together shall be able
to carry 2000 A E/F current for 3 Sec without
exceeding 200deg. Centegrade temperature rise)

300 sq mm M

LT CABLES

5 1.1 kV grade as per IS 7098-Part-I (1988), stranded


Copper conductor as per IS:8130-1984, XLPE
insulation as per IS:5831-1984, extruded
PVC inner and outer sheath as per
IS:5831-1984 Hard drawn
aluminium wire armoured as per
IS:3975-1988, 1-core, of following sizes:

50 sq. mm. M

Sheet 1 of 7
ANNEX - 1A
BILL OF QUANTITY AND PRICE SCHEDULE FOR SUPPLY OF HT, LT POWER CABLES, CONTROL CABLES AND
INSTRUMENTATION CABLES

UMC Updated
Sl. No. Item Description Unit RMH
NO. RMH

(1) (2) (3)

6 1.1 kV grade as per IS:1554-1988, stranded


Copper conductor as per IS:8130-1984, PVC
insulation as per IS:5831-1984, extruded
PVC inner and outer sheath as per
IS:5831-1984 Hard drawn aluminium wire armoured
as per IS:3975-1988, 1-core, of following sizes:

i. 16 sq. mm. M

ii. 4 sq. mm. M

iii. 2.5 sq. mm. M

7 1.1 kV grade as per IS 1554 (1988), stranded Aluminium


conductor, PVC insulated as per IS 5831 (1988),
extruded PVC sheathed as per IS:5831-1984,
Hard drawn aluminium wire armoured
1-core, of following sizes
(For LCSS transformer neutral)

630 sq mm M 2700 2700

8 1.1 kV grade, stranded Aluminium conductor,


XLPE insulated as per IS 7098-Part-I (1988),
extruded PVC inner and outer sheath as per
IS:5831-1984, Hard drawn aluminium wire armoured
1-core, of following sizes:

i. 630 sq mm M

ii. 500 sq.mm M

iii. 400 sq.mm M

iv. 300 sq.mm M

v. 240 sq.mm M

vi. 185 sq.mm M

vii. 150 sq.mm M

viii. 120 sq.mm M 4200

ix. 95 sq.mm M

x. 70 sq.mm M

xi. 50 sq.mm M 9000 9750

9 1.1 kV grade as per IS 1554 (1988), stranded Aluminium


conductor, PVC insulated as per IS 5831 (1988),
extruded PVC inner and outer sheath as per
IS:5831-1984, Hard drawn aluminium srip armoured for
diameter above 13 mm and aluminium wire armoured for
diameter below 13 mm, 1-core, of following sizes

Sheet 2 of 7
ANNEX - 1A
BILL OF QUANTITY AND PRICE SCHEDULE FOR SUPPLY OF HT, LT POWER CABLES, CONTROL CABLES AND
INSTRUMENTATION CABLES

UMC Updated
Sl. No. Item Description Unit RMH
NO. RMH

(1) (2) (3)


i. 35 sq.mm M

ii. 25 sq.mm M 11000 12750

iii. 16 sq.mm M 10000 10000

iv. 10 sq.mm M 1500 1500

v. 6 sq.mm M

10 1.1 kV grade, stranded Aluminium conductor,


XLPE insulated as per IS 7098-Part-I (1988),
extruded PVC inner and outer sheath as per IS 5831-1984,
galvanised steel strip armoured as per IS 3975-1999
3-core, of following sizes

i. 300 sq mm M 50000 62000

ii. 240 sq mm M 30000 37000

iii. 185 sq mm M 20000 25000

iv. 150 sq mm M 16000 18800

v. 120 sq mm M 45000 60000

vi. 95 sq mm M 45000 53500

vii. 70 sq mm M 25000 30500

viii. 50 sq mm M 45000 53700

11 1.1 kV grade as per IS:1554-1988, 3-core,


stranded aluminium conductor as per
IS:8130-1984, PVC insulation as per
IS:5831-1984, extruded PVC inner and outer
sheathed as per IS:5831-1984, galvanised
steel strip armouring as per IS:3975-1999 for diameter
above 13 mm and steel wire armouring for diameter
below 13 mm, of the following sizes:

i. 35 sq mm M 80000 99500

ii. 25 sq mm M 53000 66700

iii. 16 sq mm M 50000 57500

iv. 10 sq mm M 65000 84500

v. 6 sq mm M 65000 79000

12 1.1 kV grade as per IS:7098 (Part-I)-1988,


2-core, stranded aluminium conductor as per
IS:8130-1984, XLPE insulation as per
IS:5831-1984, extruded PVC inner and outer
sheathed as per IS:5831-1984, galvanised
steel strip armouring as per IS:3975-1999, of
the following sizes:

i. 240 sq mm M

ii. 185 sq mm M

iii. 150 sq mm M

iv. 120 sq mm M

v. 95 sq mm M 5000 5000

vi. 70 sq mm M

vii. 50 sq mm M 3000 3000

Sheet 3 of 7
ANNEX - 1A
BILL OF QUANTITY AND PRICE SCHEDULE FOR SUPPLY OF HT, LT POWER CABLES, CONTROL CABLES AND
INSTRUMENTATION CABLES

UMC Updated
Sl. No. Item Description Unit RMH
NO. RMH

(1) (2) (3)


13 1.1 kV grade as per IS:1554-1988, 2-core,
stranded aluminium conductor as per
IS:8130-1984, PVC insulation as per
IS:5831-1984, extruded PVC inner and outer
sheathed as per IS:5831-1984, galvanised
steel strip armouring as per IS:3975-1999 for diameter
above 13 mm and steel wire armouring for diameter
below 13 mm, of the following sizes:

i. 35 sq mm M

ii. 25 sq mm M

iii. 16 sq mm M

iv. 10 sq mm M

v. 6 sq mm M

14 1.1 kV grade as per IS:1554-1988, 3-core,


stranded copper conductor as per
IS:8130-1984, PVC insulation as per
IS:5831-1984, extruded PVC inner and outer
sheathed as per IS:5831-1984,
galvanised steel strip armouring for diameter above 13
mm and steel wire armoured for diameter below 13 mm
as per IS:3975-1999, of the following sizes :

i. 4 sq mm M 110000 136500

ii. 2.5 sq mm M

15 1.1 kV grade as per IS: 7098 (PartI)-1988,


XLPE insulated & overall sheathed flexible
copper cable having stranded conductor as per
IS: 8130, 1-core of the following sizes:

i. 95 sq mm M 1000 2000

ii. 70 sq mm M 500 1000

iii. 50 sq mm M 1000 2000

16 1.1 kV grade as per IS: 1554-1988,


PVC insulated & overall sheathed flexible
copper cable having stranded conductor as per
IS: 8130, 1-core of the following sizes:

i. 35 sq mm M

ii. 25 sq mm M

iii. 16 sq mm M

iv. 10 sq mm M 1000 1750

v. 6 sq mm M

vi. 4 sq mm M

vii. 2.5 sq mm M 1000 1000

viii. 1.5 sq mm M

17 1.1 kV grade as per IS: 7098 (PartI)-1988,


XLPE insulated & overall sheathed flexible
copper cable having stranded conductor as per
IS: 8130, 3-core of the following sizes:

70 sq. mm. M

18 1.1kV grade as per IS: 1554-1988,


PVC insulated & overall sheathed flexible
copper cable having stranded conductor as per
Cl. 5 of IS: 8130, 3-core of the following sizes

i. 10 sq. mm. M

ii. 4 sq. mm. M

iii. 2.5 sq. mm. M 1000 1000

19 1.1kV grade generally as per IS: 694, 1-core,


PVC insulated unsheathed flexible copper
cable having stranded conductor as per Cl. 5 of
IS: 8130 of the following sizes:

i. 2.5 sq-mm M 12000 15000

Sheet 4 of 7
ANNEX - 1A
BILL OF QUANTITY AND PRICE SCHEDULE FOR SUPPLY OF HT, LT POWER CABLES, CONTROL CABLES AND
INSTRUMENTATION CABLES

UMC Updated
Sl. No. Item Description Unit RMH
NO. RMH

(1) (2) (3)

ii. 1.5 sq-mm M 6500 7500

20 1.1 kV grade flexible annealed tinned copper


conductor, heat resistant, EPR insulated,
CSP sheathed drag chain/trailing cables of
the following sizes :

i. 4 core, 10 sq mm M

ii. 4 core, 6 sq mm M

iii. 4 core, 4 sq mm M

iv. 4 core, 2.5 sq mm M

21 1.1 kV grade flexible annealed tinned copper


conductor, heat resistant, EPR insulated,
CSP sheathed cables of the following sizes

i. 3 Core, 240 sq.mm M

ii. 4 Core, 10 sq.mm M

iii. 4 Core, 4 sq.mm M

CONTROL CABLES

22 1.1 kV grade as per IS:1554-1988, 1.5 sq mm,


high conductivity stranded copper
conductor as per IS:8130-1984, PVC insulation
as per IS:5831-1984,extruded PVC inner and
outer sheathed as per IS:5831-1984,
galvanized steel strip/wire armoured
as per IS:3975-1999, of the following No. of
cores

i. 37 core M 1000

ii. 30 core M 30000 38500

iii. 27 core M 8500

iv. 24 core M 14000 17000

v. 19 core M 52000 63300

vi. 16 core M 50000 66200

vii 12 core M 200

viii. 10 core M 30000 41000

ix. 7 core M 17000 25500

x. 5 core M 100000 151500

xi. 4 core M

Sheet 5 of 7
ANNEX - 1A
BILL OF QUANTITY AND PRICE SCHEDULE FOR SUPPLY OF HT, LT POWER CABLES, CONTROL CABLES AND
INSTRUMENTATION CABLES

UMC Updated
Sl. No. Item Description Unit RMH
NO. RMH

(1) (2) (3)

xii. 3 core M 70000 119000

23 1.1 kV grade as per IS:1554-1988, 1.5 sq mm,


high conductivity stranded copper
conductor as per IS:8130-1984, PVC insulation
as per IS:5831-1984,extruded PVC inner and
outer sheathed as per IS:5831-1984, overall Cu tape
Shielded, galvanized steel strip/wire
armouring as per IS:3975-1999, of the
following No. of cores:

i. 37 core M

ii. 30 core M

iii. 27 core M

iv. 24 core M

v. 19 core M

vi. 16 core M

vii 12 core M

viii. 10 core M

ix. 7 core M

x. 5 core M

xi. 4 core M

xii. 3 core M

24 1.1 kV gradeas per IS:1554-1988, 2.5 sq mm,


high conductivity stranded copper
conductor as per IS:8130-1984, PVC insulation
as per IS:5831-1984, extruded PVC inner and
outer sheath as per IS:5831-1984, galvanized
steel strip/wire as per IS:3975-1999, of the
following No. of cores

i. 37 core M

ii. 30 core M 15000 18000

iii. 27 core M

iv. 24 core M 17000 21000

v. 19 core M 57000 71500

vi. 16 core M 75000 106500

vii 12 core M

viii. 10 core M 43000 53500

ix. 7 core M 15000 20000

x. 5 core M 55000 78000

xi. 4 core M

xii. 3 core M 80000 130500

25 1.1 kV grade flexible tinned copper


conductor, heat resistant, EPR insulated,
CSP sheathed drag chain/trailing cables of
the following sizes:

Sheet 6 of 7
ANNEX - 1A
BILL OF QUANTITY AND PRICE SCHEDULE FOR SUPPLY OF HT, LT POWER CABLES, CONTROL CABLES AND
INSTRUMENTATION CABLES

UMC Updated
Sl. No. Item Description Unit RMH
NO. RMH

(1) (2) (3)


i. 18 core, 1.5 sq mm M

ii. 7 core, 1.5 sq mm M

iii. 5 core, 1.5 sq mm M

INSTRUMENTATION CABLES

26 Screened twisted pair, 700V grade, CU cables


HR-PVC insulated, AL melinex tape screened,
galvanised steel wire armoured and PVC outer
sheath of following sizes:-

i. 2 Pair X 1.0 sq.mm M

ii. 5 Pair X 1.0 sq.mm M

27 Twisted pair, 700V grade, stranded copper


conductor as per IS: 8130-1984, PVC
insulation as per IS: 5831-1984, extruded PVC
inner and outer sheathed as per IS:
5831-1984, galvanised steel strip/wire
armoured as per IS: 3975-1988, aluminium
tape screened with tinned copper drain wire,
of the following sizes:

i. 10 Pair X 1.0 sq.mm M 9000 12500

ii. 5 Pair X 1.0 sq.mm M 15000 19500

iii. 2 Pair X 1.0 sq.mm M 70000 104150

28 Twisted pair, 700V grade, stranded copper


conductor as per IS: 8130-1984, PVC
insulation as per IS: 5831-1984, extruded PVC
inner and outer sheathed as per IS:
5831-1984, unarmoured, aluminium tape
screened with tinned copper , drain wire, of
the following sizes:

2 Pair X 1.0 sq.mm M

29 Twisted triad, 700V grade, stranded copper


conductor as per IS: 8130-1984, PVC
insulation as per IS: 5831-1984, extruded PVC
inner and outer sheathed as per IS:
5831-1984, galvanised steel strip/wire
armoured as per IS: 3975-1988,
aluminium tape screened with tinned copper
drain wire, of the following sizes:

i. 5T X 1.0 sqmm M 11000 15350

ii. 10T X 1.0 sqmm M 35000 44350

30 Twisted triad, 700V grade, stranded copper


conductor as per IS: 8130-1984, PVC
insulation as per IS: 5831-1984, extruded PVC
inner and outer sheathed as per IS:
5831-1984, aluminium tape screened with
tinned copper drain wire, of the following
sizes:

1T X 1.0 sqmm M 1700

31 700 V grade , twisted pair, copper conductor,


heat resistant, EPR insulated, CSP sheathed,
individual & overall screened drag Chain/
trailing cables of following sizes:

i. 14 P X 1.0 sq.mm

ii. 5 P X 1.0 sq.mm


TOTAL (Approx.)