Академический Документы
Профессиональный Документы
Культура Документы
ECOFIT
Index
1
Original Brand MV CB or MV Panel LV CB or LV Drawer Protection Panel type Original New device Page
Contactor or Contactor relay device type type
Disconnector
Nuova Magrini NA B Control Masterpact NW
A-2
Galileo
Merlin Gerin NA Compact Compact NS
A-3
C801-C1251
Merlin Gerin NA DA Masterpact NW
A-4
Square D NA DS Masterpact NW
A-5
Square D, NA SE Masterpact NW
A-8
Westinghouse
Merlin Gerin NA Selpact Masterpact NT
A-9
- NW
Unelec-Areva Normabloc 660 Unelec CNP Masterpact NW
A-10
2
Original Brand MV CB or MV Panel LV CB or LV Drawer Protection Panel type Original New device Page
Contactor or Contactor relay device type type
Disconnector
GEC Alstom HMC 1072 HMC 1072 HMC 1072
B-32
3
PE90457
4
TM
ECOFIT
Contents
ECOFITTM
Contents
5
TM
ECOFIT
What does
that mean?
6
Schneider Electric is helping
you get the most of your
equipment and installations
Installation Services
Assessment Maintenance
contract
Installation &
Commissioning
End-of-life
Technical Training
Modernisation
On-demand
Maintenance
Today, the productivity, operating safety, continuity of service and availability requirements of installations
are such that at all levels of a company, the quest for high performance is a major consideration.
Taillefer, Fluair and Vercors cubicles and more than 3000 low-voltage retrofits on T140, T12 and
Masterbloc switchboards has enabled the Center to acquire the expertise and know-how required
to help you secure the loyalty of your customers.
There are various ways of replacing old devices. The most usual methods are:
Retrofit: the original circuit breaker and its truck are replaced
p The connection interfaces (power and low voltage) are adapted for use on the original cubicle.
p The new circuit breaker is fitted with the new interfaces.
p The solution is tested mechanically with the mounting jig.
Retrofil: the original truck is retained and fitted with a new circuit breaker
p The original truck is renovated.
p The power interfaces are either retained and renovated or they are recreated.
p The new circuit breaker is adapted for mounting on the original truck.
p The solution is tested mechanically with the mounting jig.
solutions in order to provide you with constant support and help in ensuring customer satisfaction.
We pay particular attention to quality, which is our major consideration.
8
Presentation of the offer
Renovation solutions
New solutions
p Compliant with the standards in effect,
p Integration of new-generation products,
p Evolving device technology.
9
Presentation of the offer
Product life cycle
Commercialization period
The product is launched on the market and is included in the Schneider Electric catalogue.
The supply of spare parts is guaranteed.
Predicted end of
spare part offer
Expiry
Start of End of
commercialization commercialization
Prices and
delivery times
Switchgear retrofit
10
TM
COFIT EOL
EOL,
the complementary
offer
12
12 11
End-of-life:
environment in mind!
legal
a SF6 requirement for the , an
environmental duty
12
Benefit from
Schneider Electric’s
image and know-how
Quality & Environment
PE56733
14 13
Schneider Electric’s policy has always been to provide
Our common values : its customers with very close support in their daily
activities to enable them to achieve operational
Quality excellence.
Safety
Professionalism a world leader in Low & Medium
The experience of
Voltage
Schneider Electric has been manufacturing LV and MV products for
5% of sales more than 50 years and its installed base amounts to thousand millions
products and devices.
devoted to R & D The Schneider Electric brand is known worldwide and recognized
by the most demanding customers.
Local support
all over the world.
There are always A long history of innovation
Schneider Electric people for a global offer
close to you: Based on this experience as world leader, Schneider Electric has
developed a large and comprehensive range of innovative devices.
6200 Services people With one of the world leaders, you take benefit of a global leader
experience and know-how in electric distribution, automation and Power
& control.
in more than All the devices included in this overview have been designed
and manufactured to incorporate the benefits of this extensive
88 countries! experience.
More than
23,000 ECOFITTM in
services/delivered Schneider Electric
in various business segments
a brand you can trust
14
15
PE90457
TM
ECOFIT
Low Voltage
Distribution
ECOFITTM Low Voltage Distribution
LV CB or Contactor
B Control A-2
Compact C801-C1251 A-3
DA A-4
DS A-5
H series A-6
Masterpact M A-7
SE A-8
Selpact A-9
Unelec CNP A-10
Visucompact CM A-11
Associated offers -
Energy Management A-12
Associated offers -
Source-changeover systems A-12
LV Drawer
MB400 A-13
T140 A-14
Offer Extension -
Drawer components A-15
A-1
Low Voltage Distribution LV CB or Contactor
B Control
To give a new life to your installations
Original brand:
Nuova Magrini B Control Masterpact NT/NW
Galileo
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard
220 V - 660 V
800 A to B1-35 / B1-50 B2-50 B3-50 / B3-75 / B4-100
PE90573
4000 A (35 - 52 kA*) (40 - 55 kA*) B3-90 (50 - 90 kA*) (50 - 100 kA*)
PE90573
Rated Current (Ir)
* Intensity short circuit (Isc)
220 V - 660 V
800 A to Masterpact Masterpact NT / NW
4000 A NT/ NW (42 - 150 kA*)
(42 - 50 kA*)
PE90574
Rated Current (Ir)
* Intensity short circuit (Isc)
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
C][[c\WQObW]\
A-2
Low Voltage Distribution LV CB or Contactor
Compact C801-C1251
To give a new life to your installations
Original brand:
Merlin Gerin C801 to C1251N/H Compact NS
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard
Compact NS
Rated Voltage Un (50/60 Hz)
220 V 240 V 380 V 415 V 440 V 500 V 525 V 660 V 690 V
800 A to 50 to
1250 A 50 to 70 kA* 40 to 50 kA* 30 to 42 kA*
65 kA*
PE90431 059782N
Rated Current (Ir)
* Intensity short circuit (Isc)
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
C][[c\WQObW]\
A-3
Low Voltage Distribution LV CB or Contactor
DA
To give a new life to your installations
Original brand:
Merlin Gerin DSA1 / DNA1 / DSA2 / DNA2 / DRA / DNAH Masterpact NW
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard
Masterpact NW
Rated Voltage Un (50/60 Hz)
220 V 415 V 440 V 500 V 525 V 600 V 660 V 690 V
800 A to 42 to 42 to
42 to 150 kA*
6300 A 130 kA* 100 kA*
630 A PE90427
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wba;SOacrS[SntaO\R^rotSQbW]\a p. A-12
C][[c\WQObW]\
A-4
Low Voltage Distribution LV CB or Contactor
DS
To give a new life to your installations
Original brand:
Square D, DS Masterpact NW
Westinghouse
Version type:
draw-out or fixed
PE90537
Rated Voltage Un (50/60 Hz)
690 V
800 A 42 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Masterpact NW
PE90429
Rated Voltage Un (50/60 Hz)
690 V
800 A 42 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wba;SOacrS[SntaO\R^rotSQbW]\a p. A-12
C][[c\WQObW]\
A-5
Low Voltage Distribution LV CB or Contactor
H series circuit breaker
To give a new life to your installations
Original brand:
Federal Pioneer H series Masterpact NT/NW
Version type:
draw-out
Masterpact NT Masterpact NW
Rated Voltage Un (50/60 Hz)
600 V
2500 A to 6000 A 200 kA*
N/A 42 kA* - 50 kA* -
1600 A to 2000 A with fuse
85 kA* - 130 kA*
800 A to 1200 A 35 to 50 kA* (Cradle & Cradle only)
PE90616
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
C][[c\WQObW]\
A-6
Low Voltage Distribution LV CB or Contactor
Masterpact M
To give a new life to your installations
Original brand:
Merlin Gerin M08 to M63 Masterpact NW
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard
Masterpact NW
Rated Voltage Un (50/60 Hz)
220 V 415 V 440 V 500 V 525 V 600 V 660 V 690 V
800 A to 42 to 42 to
42 to 150 kA*
6300 A 130 kA* 100 kA*
PE90429
Rated Current (Ir)
* Intensity short circuit (Isc)
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wba;SOacrS[SntaO\R^rotSQbW]\a p. A-12
C][[c\WQObW]\
A-7
Low Voltage Distribution LV CB or Contactor
SE
To give a new life to your installations
Original brand:
Square D SE Masterpact NW
Version type:
draw-out or fixed
Masterpact NW
Rated Voltage Un (50/60 Hz)
240 V 480 V 600 V
3000 A
800 A to 100 kA* 85 kA*
PE90435
1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
C][[c\WQObW]\
A-8
Low Voltage Distribution LV CB or Contactor
Selpact
To give a new life to your installations
Original brand:
Merlin Gerin DN2 / DS2 / DR2 / DRS2 Masterpact NW
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard
Masterpact NT / NW
Rated Voltage Un (50/60 Hz)
220 V 415 V 440 V 500 V 525 V 600 V 660 V 690 V
630 A to 42 to 42 to
42 to 150 kA*
6300 A 130 kA* 100 kA*
PE90426
Rated Current (Ir)
* Intensity short circuit (Isc)
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
C][[c\WQObW]\
A-9
Low Voltage Distribution LV CB or Contactor
Unelec CNP
To give a new life to your installations
Original brand:
Unelec - Areva CNP Masterpact NW
Version type:
fixed device.
Only for
Normabloc 660
switchboard
PE90432
Rated Voltage Un (50/60 Hz)
660 V
PE90432
1250 A to 2000 A 36 to 100 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Masterpact NW
PE90433
Rated Voltage Un (50/60 Hz)
690 V
1250 A to 2000 A 42 to 100 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
C][[c\WQObW]\
A-10
Low Voltage Distribution LV CB or Contactor
Visucompact CM
To give a new life to your installations
Original brand:
Merlin Gerin Visucompact CM Masterpact NW
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard
PE90434
1250 A to
85 kA* 70 kA* 65 kA*
2500 A
Rated Current (Ir) PE90434
Masterpact NW
Rated Voltage Un (50/60 Hz)
220 V 240 V 380 V 415 V 440 V
1250 A to
42 to 100 kA*
2500 A
PE90435
Rated Current (Ir)
* Intensity short circuit (Isc)
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
C][[c\WQObW]\
A-11
Low Voltage Distribution LV CB or Contactor
Associated offers
Energy Management - Micrologic control units - Measurements and protections
Available
for ECOFIT™
solutions using
Masterpact
NT/NW and
Compact NS
Micrologic 2 5 6 7
Type A-E A-E-P-H A-E-P-H A-P-H
Functions Long time Long time Long time Long time
+ instantaneous + short time + short time + short time
+ instantaneous + instantaneous + instantaneous
+ earth fault + earth leakage up to 3200A
3 %UHDNHU8QLYHUVDO/RJLF 3
Plug (ULP) cord
4 Breaker &RPPXQLFDWLRQ
0RGXOH%&0
8 Line terminator
6
Source-changeover systems
Mechanical interlocking (2 types) Automatic controllers
Available for Using connecting rods or using IVE: Electrical interlocking BA or UA automatic controllers
cables
DA, Selpact and
Masterpact M
ECOFIT™
solutions using
Masterpact
NT/NW
A-12
Low Voltage Distribution LV Drawer
MB400
To give a new life to your installations
Original brand:
Merlin Gerin MB400 drawers MB400 drawers
Version type: for distribution for distribution
withdrawable & motor feeders & motor feeders
drawers
compatible
with MB400 LV
switchboards
MB400 drawers
Rated Voltage Un (50/60 Hz)
440 VAC
625 A
500 A
From 1 to 6 modules manually or electrically operated
250 A
125 A
Rated Current (Ir)
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-15
C][[c\WQObW]\
A-13
Low Voltage Distribution LV Drawer
T140
To give a new life to your installations
Original brand:
Merlin Gerin T140 drawers T140 drawers
Version type: for distribution for distribution
withdrawable & motor feeders & motor feeders
drawers
compatible with
T140
LV switchboards
T140 drawers
Rated Voltage Un (50/60 Hz)
440 VAC
625 A
500 A
From 1 to 6 modules manually or electrically operated
250 A
125 A PE90685
Associated offers
Energy Management
;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-15
C][[c\WQObW]\
A-14
Low Voltage Distribution LV Drawer
Associated offers
Specific spare parts:
Available
for ECOFIT™
solutions using Drawer components
Masterpact
NT/NW and 3ZSQb`WQOZRWab`WPcbW]\ºFc\QbW]\OZc\Wba<SX rO\US
Compact NS
;otor co\tr]ZQ][[O\RO\R^rotSQbW]\aºFc\QbW]\OZc\Wba
1 component motor feeder 2 components motor feeder 3 components motor feeder
Co\tr]ZQ][[O\ROcfWZWO`WSaf]`OZZtg^Saof drawers
Miniature circuit-breaker
Auxiliary relays
Protection auxiliary circuit
A-15
PE90457
TM
ECOFIT
Medium
Voltage
Distribution
ECOFITTM Medium Voltage Distribution
MV CB or Contactor or Disconnector
5-15 kV MC switchgear B-2
All AEG cubicles B-3
Belledonne B200-B400 B-4
Belledonne B200G B-5
Belledonne B650 B-6
Belledonne B900 B-7
BVP 17 B-8
CEMABLOC-C23mc 15 & 27 B-9
CEMABLOC-C23mc 15 & 27 B-10
CEMAFLUOR-C26.0 B-11
Chamrousse B-12
Composit B-13
CSIM 1-12 B-14
CSIM 3-12 B-15
D-12 B-16
D-24 B-17
DNF4-2E B-18
DNF4 MI&FI B-19
DNF5/DNF5-2B B-20
DNF6 B-21
DNF7 B-22
Epoclad B-23
Fluair F100-F200 B-24
Fluair F100C B-25
Fluair F400C B-26
Fluair F400G B-27
FLUOMATIC F540 B-28
FLUOMATIC F943 B-29
GS-10 B-30
HMC 400 & HMC 410 B-31
HMC 1072 B-32
HMC 1172 B-33
HMX 36 B-34
KIT 25-PGDt B-35
KIT 27.2-PGHt B-36
L B-37
Metalclad switchgear B-38
Motorstart P12D-P30D B-39
Motorstart P50D B-40
Motorstart P500D B-41
MX 51 & MX 81 B-42
NORMABLOC N1347 B-43
NORMASEPT N743 B-44
PA, SC, SD B-45
R B-46
Siclad B-47
Solenarc DSE Metal-Clad switchgear B-48
Taillefer T900-T1080 B-49
Venus B-50
VM6 DM12 B-51
VM6 DM22-DM23 B-52
VMX B-53
WAK B-54
WBA B-55
WBB B-56
WKC B-57
YSF6 B-58
MV Panel
D-12 B-60
D-24 B-61
F100/200 B-62
F100C B-63
PX 12-24 B-64
R B-65
VMX B-66
WBA B-67
WBB B-68
WKC B-69
B-1
Medium Voltage Distribution MV CB or Contactor or Disconnector
5-15 kV Metal-Clad Switchgear
To give a new life to your installations
Original brand:
Square D
Version type: VAD2
Magnum CB (Vacuum)
draw-out VAD3
PE90543
5 kV 15 kV
3000 A
2000 A VAD2 (29 kA*) VAD2 (18 - 28 kA*)
VAD3 (41 kA*) VAD3 (37 kA*)
1200 A
PE90544
5 kV 15 kV
3000 A
2000 A 5SSB (29 - 41 kA*) 15SSB (18 - 28 kA*)
15SSB (37 kA*)
1200 A
Magnum CB main
characteristics A true extended life time
Built with totally new Commercialisation End of End of End
components and tested to commercialisation spare parts of life
ANSI standards,
Magnum circuit breakers
< 1985 1995 2006
correctly interface with
the existing breaker
compartment components
and maintain safety 2004 ECOFIT Ongoing
Magnum CB
interlocks inherent
in the original equipment
design.
s New circuit breakers
are installed in existing
switchgear.
s Original footprint is left
intact, saving time and Offer extension
money.
s Installation expense is
a fraction of new
PE90461
equipment costs.
PE90437
B-2
Medium Voltage Distribution MV CB or Contactor or Disconnector
All AEG cubicles
To give a new life to your installations
Original brand:
Concordia
Sprecher TG TG
Version type:
disconnector
compatible with
all AEG cubicles
PE90656
PE90656
12 kV 24 kV 36 kV
2500 A to 6300 A
15 to 63 kA* 16 to 31.5 kA*
630 A to 2500 A 19 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
TG
Rated Voltage Un (50/60 Hz)
PE90656
12 kV 24 kV 36 kV
2500 A to 6300 A
15 to 63 kA* 16 to 31.5 kA*
630 A to 2500 A 19 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
B-3
Medium Voltage Distribution MV CB or Contactor or Disconnector
Belledonne B200-B400
To give a new life to your installations
Original brand:
Merlin Gerin DSE22 LF2 (SF6), LF3 (SF6)
Version type: to SF1 (SF6)
withdrawable
DSE78 Evolis (Vacuum)
device
compatible with
Belledonne B200/ Main technical characteristics
B400 cubicles
DSE22 to DSE78
Rated Voltage Un (50/60 Hz)
PE90402
PE90400
7.2 kV 12 kV 17.5 kV 24 kV
3500 A
3150 A
3000 A 29 to 50 kA*
1250 A 24 to 48 kA* 15 to 46 kA* 10 to 29 kA*
630 A
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90401
7.2 kV 12 kV 17.5 kV 24 kV
3500 A
3150 A
LF2/LF3 LF2/LF3
3000 A (29 to 40 kA*)
(29 to 50 kA*)
Evolis Evolis
1250 A (40 kA*, SF1
(40 kA* - 2500 A max) (10 to 25 kA*)
630 A 2500 A max)
Rated Current (Ir)
Offer extension
PE90400
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-4
Medium Voltage Distribution MV CB or Contactor or Disconnector
Belledonne B200G
To give a new life to your installations
Original brand:
Merlin Gerin DSE22K LF1 (SF6)
Version type: DSE23K Evolis (Vacuum)
withdrawable
device
compatible with
Belledonne
B200G
cubicles
Main technical characteristics
DSE22K to DSE23K
PE90405
PE90403
PE90404
Rated Voltage Un (50/60 Hz)
7.2 kV
630 A to 1250 A 25 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90393
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-5
Medium Voltage Distribution MV CB or Contactor or Disconnector
Belledonne B650
To give a new life to your installations
Original brand:
Merlin Gerin LF1 (SF6)
Version type: DIS R400 & R400D (SF6)
withdrawable Evolis (Vacuum)
device
compatible with
Belledonne B650
cubicles
Main technical characteristics
PE90398
DIS
PE90396
PE90398
Rated Voltage Un (50/60 Hz)
7.2 kV
630 A to 1250 A 31.5 kA
400 A to 630 A
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90393
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-6
Medium Voltage Distribution MV CB or Contactor or Disconnector
Belledonne B900
To give a new life to your installations
Original brand:
Merlin Gerin DIS SF1 (SF6)
Version type:
withdrawable
device
compatible with
Belledonne B900
cubicles
Main technical characteristics
DIS
PE90397
PE90396
SF1
PE90399
Rated Voltage Un (50/60 Hz)
24 kV
630 A to 1250 A 25 kA*
400 A to 630 A
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90393
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-7
Medium Voltage Distribution MV CB or Contactor or Disconnector
BVP 17
To give a new life to your installations
Original brand:
AEI, GEC, GEC
ALSTHOM BVP 17 (Oil) VMX (Vacuum)
Version type:
withdrawable
device compatible
with BVP 17
cubicles
Main technical characteristics
PE90605
BVP 17
PE90396
PE90606
VMX
Rated Voltage Un (50/60 Hz)
11 kV
1250 A
800 A Up to 25 kA*
400 A
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90604
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-8
Medium Voltage Distribution MV CB or Contactor or Disconnector
Cemabloc-C23mc 15 & 27
To give a new life to your installations
Original brand:
CEM
Version type: CB FP (SF6)
withdrawable
device
compatible with
CEMABLOC-
C23mc 15 et 27
cubicles
Main technical characteristics
CB
PE90462
Rated Voltage Un (50/60 Hz)
23 kV
400 A to 1250 A 12.5 - 16/25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90419
PE90463
FP
Rated Voltage Un (50/60 Hz)
23 kV
400 A to 1250 A 12.5 - 16/25kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90461
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-9
Medium Voltage Distribution MV CB or Contactor or Disconnector
Cemabloc-C23mc 15 & 27
To give a new life to your installations
Original brand:
CEM
Version type: CB 6 poles HVX (Vacuum) 6 poles
withdrawable
device
compatible with
CEMABLOC-
C23mc 15 et 27
cubicles
Main technical characteristics
PE90464
CB
Rated Voltage Un (50/60 Hz)
23 kV
2500 A 12.5 - 16/25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90419
PE90465
HVX
Rated Voltage Un (50/60 Hz)
23 kV
2500 A 12.5 - 16/25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90461
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-10
Medium Voltage Distribution MV CB or Contactor or Disconnector
Cemafluor - C26.0
To give a new life to your installations
Original brand:
CEM
Version type: CS FPR (SF6)
withdrawable
device
compatible with
CEMAFLUOR
C26.0
cubicles
Main technical characteristics
CS
PE90467
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 1250 A 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90466
PE90468
FPR
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 1250 A 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90466
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-11
Medium Voltage Distribution MV CB or Contactor or Disconnector
Chamrousse
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
LF2 (SF6)
withdrawable DIS R400 (SF6)
device R400D (SF6)
compatible with
Chamrousse
cubicles
PE90447
7.2 kV 12 kV
630 A to 1250 A 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90446
PE90448
7.2 kV 12 kV
630 A to 1250 A LF2 (25 kA*)
80 A to 250 A R400/R400D (10 kA*)
Rated Current (Ir)
Offer extension
PE90446
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-12
Medium Voltage Distribution MV CB or Contactor or Disconnector
Composit 15-24 kV
To give a new life to your installations
Original brand:
Nuova Magrini
Galileo MG SF1 (SF6)
Version type:
withdrawable
device
compatible
with Composit Main technical characteristics
cubicles
MG
PE90576
PE90575
PE90576
Rated Voltage Un (50/60 Hz)
10 kV 15 kV 17 kV 20 kV 24 kV
630 to 1250 A 8.7 to 5 to 12.5 to 3.6 to 6.3 to
28.9 kA* 29 kA* 29 kA* 24 kA* 21.7 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
SF1**
PE90232
Rated Voltage Un (50/60 Hz)
10 kV 15 kV 17.5 kV 20 kV 24 kV
630 to 1250 A 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc) ** For Composit panel 860 mm wide
Offer extension
PE90575
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-13
Medium Voltage Distribution MV CB or Contactor or Disconnector
CSIM 1-12
To give a new life to your installations
Original
brand: VEB “Otto
Buchwitz” SCI-4 VEIVACUUM F (Vacuum)
Starkstroman-
lagenbau Dresden
Version type:
withdrawable Main technical characteristics
device compatible
PE90561
with CSIM 1-12 SCI-4
cubicles Rated Voltage Un (50/60 Hz)
12 kV
PE90560
PE90562
VEIVACUUM F
Rated Voltage Un (50/60 Hz)
12 kV
630 A to 1250 A 16 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
1975 1991
Offer extension
PE90563
PE90643
PE90437
MiCOM P
series 10 - 20 - 30 - 40
PE90488
Sepam
series 10 - 20 - 40 - 60 - 80
B-14
Medium Voltage Distribution MV CB or Contactor or Disconnector
CSIM 3-12
To give a new life to your installations
Original
brand: VEB “Otto
Buchwitz”
VEIVACUUM F (Vacuum)
SCI-4
Starkstroman- VA 10031 (Vacuum)
lagenbau Dresden
Version type:
withdrawable Main technical characteristics
device compatible
PE90640
with CSIM 3-12 SCI-4
cubicles Rated Voltage Un (50/60 Hz)
12 kV
PE90640
PE90641
Rated Voltage Un (50/60 Hz)
12 kV
1600 A to 2500 A VA (16 to 31.5 kA*)
630 A to 1250 A VEIVACUUM F
(16 to 31.5 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90563
PE90643
PE90437
MiCOM P
series 10 - 20 - 30 - 40
PE90488
Sepam
series 10 - 20 - 40 - 60 - 80
B-15
Medium Voltage Distribution MV CB or Contactor or Disconnector
D-12
To give a new life to your installations
Original brand:
AEG BAL
Version type: VAA (Vacuum)
VAA
withdrawable VA (Vacuum)
device compatible
VA
with D-12 cubicles
PE90648
PE90648
Rated Voltage Un (50/60 Hz)
12 kV
1600 A VA (25 to 31.5 kA*)
200 A to 1250 A VAA (20 to 25 kA*) BAL (10 to 20 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90650
12 kV
1600 A VA (25 to 31.5 kA*)
630 A to 1250 A VAA (20 to 25 kA*)
Rated Current (Ir)
Offer extension
PE90649
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-16
Medium Voltage Distribution MV CB or Contactor or Disconnector
D-24
To give a new life to your installations
Original brand:
AEG BAL
Version type: VAA (Vacuum)
withdrawable
VAA
device compatible
with D-24 cubicles
PE90651
PE90651
Rated Voltage Un (50/60 Hz)
24 kV
630 A to 1250 A VAA (16 to 25 kA*)
100 A to 630 A BAL (10 to 16 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90650
VAA
Rated Voltage Un (50/60 Hz)
24 kV
630 A to 1250 A 10 to 25 kA*
Rated Current (Ir)
Offer extension
PE90649
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-17
Medium Voltage Distribution MV CB or Contactor or Disconnector
DNF4-2E
To give a new life to your installations
Original brand:
Alsthom
FP (SF6)
Version type: FP (SF6)
withdrawable HVX (Vacuum)
GFA (SF6)
device compatible CVX (Vacuum)
with DNF4-2E
cubicles
PE90667
PE90668
FP - GFA
Rated Voltage Un (50/60 Hz)
12 kV
400 A to 2000 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
FP - HVX - CVX
PE90669
Rated Voltage Un (50/60 Hz)
12 kV
400 A to 2000 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90670
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
PE90671
Sepam series 10 - 20 - 40 - 60 - 80
B-18
Medium Voltage Distribution MV CB or Contactor or Disconnector
DNF4 MI&FI
To give a new life to your installations
Original brand:
Alsthom
FP (SF6)
Version type: FP (SF6)
withdrawable HVX (Vacuum)
device compatible
with DNF4 MI&FI
cubicles
PE90671
PE90672
Rated Voltage Un (50/60 Hz)
12 kV
400 A to 2500 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
FP - HVX
PE90673
Rated Voltage Un (50/60 Hz)
12 kV
400 A to 2500 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90671
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-19
Medium Voltage Distribution MV CB or Contactor or Disconnector
DNF5/DNF5-2B
To give a new life to your installations
Original brand:
Alsthom
FP (SF6)
Version type: FP (SF6)
withdrawable HVX (Vacuum)
device compatible
with DNF5 /
DNF5-2B cubicles
PE90678
PE90672
Rated Voltage Un (50/60 Hz)
17.5 kV
630 A to 2000 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
FP - HVX
PE90673
Rated Voltage Un (50/60 Hz)
17.5 kV
630 A to 2000 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90678
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-20
Medium Voltage Distribution MV CB or Contactor or Disconnector
DNF6
To give a new life to your installations
Original brand:
Alsthom
FP (SF6)
Version type: FP (SF6)
withdrawable HVX (Vacuum)
device compatible
with DNF6 cubicles
PE90679
PE90680
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 2000 A 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
FP - HVX
PE90673
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 2000 A 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90679
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-21
Medium Voltage Distribution MV CB or Contactor or Disconnector
DNF7
To give a new life to your installations
Original brand:
Alsthom
FP (SF6)
Version type: FP (SF6)
withdrawable HVX-O2 (Vacuum)
device compatible
with DNF7 cubicles
PE90674
PE90675
Rated Voltage Un (50/60 Hz)
36 kV
400 A to 2000 A 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
FP - HVX-O2
PE90676
Rated Voltage Un (50/60 Hz)
36 kV
400 A to 2000 A 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90674
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-22
Medium Voltage Distribution MV CB or Contactor or Disconnector
Epoclad
To give a new life to your installations
Original brand:
Nuova Magrini LF1 (SF6)
Galileo DHF LF2 (SF6)
Version type: F LF3 (SF6)
withdrawable
device
SF1 (SF6)
compatible with
Epoclad cubicles Main technical characteristics
Rated Voltage Un (50/60 Hz)
PE90578
6 kV 7.2 kV 10 kV 12 kV 15 kV 17 kV 20 kV 24 kV
PE90577
630 A to 20DHF
3150 A 350-750
6DHF 12F
6DHF/N 7F/N 10DHF 7F 15DHF 12F/N 24DHF (8 -
250-350 250-750 350-750 350-850 350-500 18 kA*)
250-500 350-750
(20 -
(29 - (12 - (18 - (13.5 -
(12.5 -
(9.2 - 24F
34 kA*) 43 kA*) 48 kA*) 32.5 kA*) 14.5 kA*) 500-750
48 kA*) 48 kA*)
(12.5 -
18 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90579
7.2 kV 12 kV 17.5 kV 24 kV
3150 A LF3 (50 kA*)
2000 A LF2 (50 kA*) LF3 (40 kA*)
630 A to LF2 (40 kA*)
1250 A
LF1 (31.5 kA*) SF1 (25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90577
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-23
Medium Voltage Distribution MV CB or Contactor or Disconnector
Fluair F100-F200
To give a new life to your installations
Original brand:
Merlin Gerin FG1 LF2 (SF6), LF3 (SF6)
Version type: FG2 Evolis (Vacuum)
withdrawable
device
compatible with
Fluair F100/200
cubicles
Main technical characteristics
PE90409
FG1 / FG2
PE90410
Rated Voltage Un (50/60 Hz)
7.2 kV 12 kV 17.5 kV
630 A to 3150 A 25 to 50 kA* 25 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90411
7.2 kV 12 kV 17.5 kV
630 A to 3150 A LF2/LF3 (25 to 50 kA*) LF2/LF3
(29 to 31.5 kA*)
Evolis (40 kA* - 2500 A max)
Rated Current (Ir)
Offer extension
PE90409
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-24
Medium Voltage Distribution MV CB or Contactor or Disconnector
Fluair F100C
To give a new life to your installations
Original brand:
Merlin Gerin R400 R400 (SF6)
Version type:
R400D R400D (SF6)
withdrawable
device
compatible with
Fluair F100C
cubicles
Main technical characteristics
R400 / R400D
PE90413
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90412
R400 / R400D
PE90413
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)
1980 1988
(always available)
ECOFIT Ongoing
R400 / R400D
Offer extension
PE90409
PE90437
MiCOM P
series 10 - 20 - 30 - 40
PE90488
Sepam
series 10 - 20 - 40 - 60 - 80
B-25
Medium Voltage Distribution MV CB or Contactor or Disconnector
Fluair F400C
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: FC4 SF2 (SF6)
withdrawable
device
compatible with
Fluair F400C
cubicles
PE90415
FC4
Rated Voltage Un (50/60 Hz)
36 kV
1250 A to 2500 A 31.5 to 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
SF2
PE90416
Rated Voltage Un (50/60 Hz)
36 kV
1250 A to 2500 A 31.5 to 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90415
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-26
Medium Voltage Distribution MV CB or Contactor or Disconnector
Fluair F400G
To give a new life to your installations
Original brand:
Merlin Gerin SF1 (SF6)
Version type: FG4
SF2 (SF6)
withdrawable
device
compatible with
Fluair F400G
cubicles
FG4
Rated Voltage Un (50/60 Hz)
PE90418
24 kV 36 kV
1250 A to 2500 A 40 kA* 25 to 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
SF1 / SF2
PE90450
Rated Voltage Un (50/60 Hz)
24 kV 36 kV
1250 A to 2500 A 40 kA* 25 to 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90406
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-27
Medium Voltage Distribution MV CB or Contactor or Disconnector
FLUOMATIC F540
To give a new life to your installations
Original brand:
Delle Alsthom
Version type: FR62 FP62 (SF6)
fixed device
compatible with
FLUOMATIC
F540 cubicles
PE90470
FR62
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 16/25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90471
PE90469 FP62
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 16/25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90487
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-28
Medium Voltage Distribution MV CB or Contactor or Disconnector
FLUOMATIC F943
To give a new life to your installations
Original brand:
Delle Alsthom
Version type: FR62 BLV (SF6)
fixed device
compatible with
FLUOMATIC
F943
cubicles
PE90470
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 1250 A 16 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90472
PE90474
BLV
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 1250 A 16 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90487
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-29
Medium Voltage Distribution MV CB or Contactor or Disconnector
GS-10
To give a new life to your installations
Original brand:
AEG
Version type: GE VA/VAA (Vacuum)
withdrawable
device
compatible with
GS-10 cubicles
PE90540
PE90550
VA/VAA
PE90541
Rated Voltage Un (50/60 Hz)
up to 12 kV
630 A to 3000 A 16 to 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90539
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-30
Medium Voltage Distribution MV CB or Contactor or Disconnector
HMC 400 & HMC 410
To give a new life to your installations
Original brand:
GEC Industrial HMC 400 (Vacuum) HMC 400 (Vacuum)
Controls,
HMC 410 (Vacuum) HMC 410 (Vacuum)
GEC, GEC
Alstom, Alstom
Version type:
withdrawable
vacuum motor
starter
PE90594
Rated Voltage Un (50/60 Hz)
3.3 kV 6.6 kV
PE90594 400 A 43.8 kA* 26.3 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90595
Rated Voltage Un (50/60 Hz)
3.3 kV 6.6 kV Motors up to 13.8 kV / 400 A.
(self selecting).
400 A 43.8 kA* 26.3 kA* Multi-Voltage Inputs from 24 V
to 256 V AC or DC.
Rated Current (Ir)
* Intensity short circuit (Isc)
ECOFIT Ongoing
refurbishment,
using Gemstart unit
Refurbishment
PE90599
HMC 1072
PE90599
HMC 1072
Rated Voltage Un (50/60 Hz)
7.2 kV
400 A 63 kA* r.m.s./1s - 50 kA* r.m.s./3s
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90599
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-32
Medium Voltage Distribution MV CB or Contactor or Disconnector
HMC 1172
To give a new life to your installations
Original brand:
GEC Industrial
Controls, GEC, HMC 1172 (Vacuum) HMC 1172 (Vacuum)
GEC Alstom,
Alstom
Version type:
withdrawable
vacuum motor Main technical characteristics
starter
HMC 1172
PE90600
Rated Voltage Un (50/60 Hz)
7.2 kV
400 A 63 kA* r.m.s./1s - 50 kA* r.m.s./3s
Rated Current (Ir)
* Intensity short circuit (Isc)
HMC 1172
PE90600 Rated Voltage Un (50/60 Hz)
7.2 kV
400 A 63 kA* r.m.s./1s - 50 kA* r.m.s./3s
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90601
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-33
Medium Voltage Distribution MV CB or Contactor or Disconnector
HMX 36
To give a new life to your installations
Original brand:
GEC, GEC
Alstom, Alstom HMX 36 (Vacuum) HMX 36 (Vacuum)
Version type:
withdrawable
vacuum
switchgear
Main technical characteristics
HMX 36
PE90602
PE90602
400 A 25 kA* r.m.s./1s - 31.5 kA* r.m.s./3s
Rated Current (Ir)
* Intensity short circuit (Isc)
HMX 36
Rated Voltage Un (50/60 Hz)
36 kV
400 A 25 kA* r.m.s./1s - 31.5 kA* r.m.s./3s
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90602
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-34
Medium Voltage Distribution MV CB or Contactor or Disconnector
KIT25-PGDT
To give a new life to your installations
Original brand:
CEM
Version type: CC FP (SF6)
fixed device
compatible
with KIT 25 -
PGDt cubicles
PE90476
CC
Rated Voltage Un (50/60 Hz)
24 kV
400 A 12.5 & 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90477
PE90475 FP
Rated Voltage Un (50/60 Hz)
24 kV
400 A 12.5 & 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90487
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-35
Medium Voltage Distribution MV CB or Contactor or Disconnector
KIT 27.2-PGHT
To give a new life to your installations
Original brand:
CEM
Version type: HF4K FP (SF6)
fixed device
compatible
with KIT 27.2 -
PGHt cubicles
Main technical characteristics
HF4K
PE90479
Rated Voltage Un (50/60 Hz)
24 kV
400 A 14.5 & 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90480
PE90478 FP
Rated Voltage Un (50/60 Hz)
24 kV
400 A 14.5 & 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90478
PE90437
MiCOM P
series 10 - 20 - 30 - 40
PE90488
Sepam
series 10 - 20 - 40 - 60 - 80
B-36
Medium Voltage Distribution MV CB or Contactor or Disconnector
L
To give a new life to your installations
Original brand:
AEG
Version type: Type D HVX (Vacuum)
withdrawable and E
device
compatible with
L cubicles
D, E
PE90558
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV
400 A to 2500 A 20 to 50 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
HVX
PE90559
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV
400 A to 2500 A 20 to 50 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90549
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-37
Medium Voltage Distribution MV CB or Contactor or Disconnector
Metalclad switchgear
To give a new life to your installations
Original brand:
Federal Pioneer
DST 2 & 5 DST 2V (Vacuum)
Version type:
withdrawable
(Air Magnetic Breakers)) DST 5V (Vacuum)
device compatible
with metalclad
switchgear
PE90618
Rated Voltage Un (50/60 Hz)
5 kV 15 kV
3000 A
2000 A DST 2 & 5 (250 - 350 MVA) DST 2 (500 - 750 MVA)
PE90618-2
1200 A
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90619
Rated Voltage Un (50/60 Hz)
5 kV 15 kV
3000 A
2000 A DST 2V (350 MVA) DST 5V (500 - 750 MVA)
1200 A
Rated Current (Ir)
* Intensity short circuit (Isc)
Rack mechanism
1999 ECOFIT added
DST 2V & 5V (Vacuum)
Main characteristics
Magnum circuit breakers correctly interface with Optional capabilities
the existing breaker compartment components
Ŷ,QFUHDVHGIDXOWFXUUHQWLQWHUUXSWLRQUDWLQJ
and maintain safety interlocks inherent in the
Ŷ5HOD\XSJUDGHLPSURYHGDFFXUDF\DQG
original equipment design.
repeatabilityDQGSHUIRUPDQFH
Ŷ1HZFLUFXLWEUHDNHUVDUHLQVWDOOHGLQH[LVWLQJ ŶPower meteringmonitoring and
switchgear. communication.
Ŷ2ULJLQDOIRRWSULQWLVOHIWLQWDFWVDYLQJWLPHDQG Ŷ*URXQGDQGWHVWGHYLFHVDYDLODEOHIRUYDULRXV
PE90619
KA / KDA
PE90388
Rated Voltage Un (50/60 Hz)
7.2 kV
90 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)
R400 / R400D
PE90389
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90387
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-39
Medium Voltage Distribution MV CB or Contactor or Disconnector
Motorstart P50D
To give a new life to your installations
Original brand:
Merlin Gerin R400 (SF6)
Version type: C, CD R400D (SF6)
withdrawable CTV1 (Vacuum)
device
compatible with
Motorstart P50D
cubicles
C / CD
PE90391
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 200 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)
R400 / R400D
PE90392
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90387
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-40
Medium Voltage Distribution MV CB or Contactor or Disconnector
Motorstart P500D
To give a new life to your installations
Original brand:
Merlin Gerin R400 (SF6)
Version type: C1, CD1 R400D (SF6)
withdrawable CTV1 (Vacuum)
device
compatible with
Motorstart P500D
cubicles
PE90393
PE90394
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)
R400 / R400D
PE90395
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90393
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-41
Medium Voltage Distribution MV CB or Contactor or Disconnector
MX51 & MX81
To give a new life to your installations
Original brand:
GEC, GEC Alstom
MX 51 (Vacuum) MX 51 (Vacuum)
Version type:
fixed pattern MX 81 (Vacuum) MX 81 (Vacuum)
vacuum
switchgear
3.6 kV 17.5 kV
2000 A MX51 (31.5 kA*) MX51 (31.5 kA*)
1250 A MX81 (12.5 kA*) MX81 (12.5 kA*)
MX51 (25 kA*) MX51 (25 kA*)
PE90603 630 A MX81 (20 kA*) MX81 (20 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90603
Rated Voltage Un (50/60 Hz)
3.6 kV 17.5 kV
2000 A MX51 (31.5 kA*) MX51 (31.5 kA*)
1250 A MX81 (12.5 kA*) MX81 (12.5 kA*)
MX51 (25 kA*) MX51 (25 kA*)
630 A MX81 (20 kA*) MX81 (20 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90437
PE90603
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-42
Medium Voltage Distribution MV CB or Contactor or Disconnector
Normabloc N1347
To give a new life to your installations
Original brand:
Delle Alsthom
Version type:
HVX (Vacuum)
HL
withdrawable FPX (Vacuum)
device
compatible with
NORMABLOC
N1347 cubicles
PE90482
HL
Rated Voltage Un (50/60 Hz)
17.5 kV
630 A to 1250 A 25 & 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90475
PE90483
HVX / FPX
Rated Voltage Un (50/60 Hz)
17.5 kV
630 A to 1250 A 25 & 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90481
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-43
Medium Voltage Distribution MV CB or Contactor or Disconnector
Normasept N743
To give a new life to your installations
Original brand:
Delle Alsthom
Version type: HL FP (SF6)
fixed device
compatible with
NORMASEPT
N743 cubicles
PE90485
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90484
PE90486
FP
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90487
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-44
Medium Voltage Distribution MV CB or Contactor or Disconnector
PA, SC, SD
To give a new life to your installations
Original brand:
Concordia
Sprecher HP T/W/Z HVX (Vacuum)
Version type:
withdrawable
device compatible
with PA, SC and
SD panels
Main technical characteristics
HP 300 - 500
PE90653
Rated Voltage Un (50/60 Hz)
7.2 kV to 12 kV 24 kV
1250 A to 3150 A 12.5 to 40 kA*
800 A to 1250 A 8.4 to 21.7 kA*
Rated Current (Ir)
HVX
PE90652
PE90653
Offer extension
PE90654
PE90437
MiCOM P
series 10 - 20 - 30 - 40
PE90488
Sepam
series 10 - 20 - 40 - 60 - 80
B-45
Medium Voltage Distribution MV CB or Contactor or Disconnector
R
To give a new life to your installations
Original brand:
AEG
Version type:
E-Breaker
VA/VAA (Vacuum)
withdrawable M-Breaker
device
compatible with
R cubicles
Main technical characteristics
E/M
PE9055
Rated Voltage Un (50/60 Hz)
12 kV 17 - 24 kV 36 kV
4000 A
2500 A 25 to 50 kA*
16 to 31.5 kA*
1250 A
PE90554
Rated Voltage Un (50/60 Hz)
PE90556
12 kV 17 kV 24 kV 36 kV
4000 A VA
VA (up to 31.5 kA*)
2500 A (up to 50 kA*) VA VA VA
(up to 40 kA*) (up to 31.5 kA*) (up to 40 kA*)
1250 A VAA VAA
(up to 25 kA*) (up to 25 kA*) VA
VA VA (up to 31.5 kA*)
(up to 50 kA*) (up to 31.5 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90554
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-46
Medium Voltage Distribution MV CB or Contactor or Disconnector
Siclad
To give a new life to your installations
Original brand:
Ansaldo
Version type: MAG II LF2 (SF6)
withdrawable
device
compatible with
Siclad cubicles
Main technical characteristics
PE90580
PE90581
6 kV 10 kV 15 kV
630 A to 2000 A MAG II - 6 - 250 MAG II - 10 - 500 MAG II - 15 - 350
MAG II - 6 - 400 MAG II - 15 - 300
(20 to 28 kA*)
(20 to 48 kA*) (12 to 30 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
LF2**
PE90582
Rated Voltage Un (50/60 Hz)
6 kV 10 kV 15 kV
2000 A LF2 (40 kA*)
630 A to 1250 A LF1 (31.5 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc) ** For Siclad panel 730 mm & 850 mm wide
1969 1997
Offer extension
PE90580
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-47
Medium Voltage Distribution MV CB or Contactor or Disconnector
Solenarc DSE Metal-Clad Switchgear
To give a new life to your installations
Original brand:
Square D
Version type: Type DSE Magnum CB (Vacuum)
Draw-out
PE90540
5 kV 15 kV
3000 A
2000 A DSE-23B (250 MVA) DSE (250 - 1000 MVA)
1200 A
PE90541
5 kV 15 kV
3000 A
2000 A 5MGSB (250 MVA) 15MGSB (250 - 1000 MVA)
1200 A
equipment costs.
PE90437
B-48
Medium Voltage Distribution MV CB or Contactor or Disconnector
Taillefer T900-T1080
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: DST LF3 (SF6)
withdrawable
device
compatible with
Taillefer
T900 / T1080
cubicles
Main technical characteristics
DST
Rated Voltage Un (50/60 Hz)
PE90408
7.2 kV 17.5 kV
1250 A to 2500 A 50 kA* 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90406
LF3
PE90407
Rated Voltage Un (50/60 Hz)
7.2 kV 17.5 kV
1250 A to 2500 A 50 kA* 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90406
PE90437
MiCOM P
series 10 - 20 - 30 - 40
PE90488
Sepam
series 10 - 20 - 40 - 60 - 80
B-49
Medium Voltage Distribution MV CB or Contactor or Disconnector
Venus
To give a new life to your installations
Original brand:
Nuova Magrini
GI LF1 (SF6)
Galileo
Version type: GL LF3 (SF6)
withdrawable
device
compatible with Main technical characteristics
Venus cubicles Rated Voltage Un (50/60 Hz)
PE90584
7 kV 12 kV 17 kV 24 kV 36 kV
PE90583
1600 A
to
GL GL GL GL
(50 kA*) (20 to 40 kA*) (25 to 40 kA*) (20 to 31.5 kA*)
3150 A
630 A to GI GI
1250 A (12.5 to 31.5 kA*) (12 to 25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90585
7 kV 12 kV 17 kV 24 kV 36 kV
3150 A LF3**
1600 A (50 kA*)
630 A to LF1***
1250 A (31.5 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc) ** For Venus panel 900 mm wide *** For Venus panel 600 mm wide
Offer extension
PE90583
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-50
Medium Voltage Distribution MV CB or Contactor or Disconnector
VM6 DM12
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: FB4 SF1 (SF6)
withdrawable
device
compatible with
VM6-DM12
cubicles
Main technical characteristics
FB4
PE90422
PE90415
SF1
PE90423
Rated Voltage Un (50/60 Hz)
7.2 kV 12 kV 17.5 kV 24 kV
400 A to 1250 A 12.5 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90400
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-51
Medium Voltage Distribution MV CB or Contactor or Disconnector
VM6 DM22-DM23
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: FB4 SF1 (SF6)
fixed device
compatible with
VM6 DM22/DM23
cubicles
PE90565
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 20 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90419
PE90566
SF1
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 20 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90419
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-52
Medium Voltage Distribution MV CB or Contactor or Disconnector
VMX
To give a new life to your installations
Original brand:
GEC, GEC
Alstom, Alstom VMX (Vacuum) VMX (Vacuum)
Version type:
withdrawable
vacuum
switchgear
VMX
Rated Voltage Un (50/60 Hz)
11 kV
630 A - 800 A - PE90692
Up to 25 kA* for 3s
1250 A - 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90692
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-53
Medium Voltage Distribution MV CB or Contactor or Disconnector
WAK
To give a new life to your installations
Original brand:
AEG
Version type: Type D
HVX (Vacuum)
withdrawable and E
device
compatible with
WAK cubicles
Main technical characteristics
PE90546
D&E
PE90547
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV 20 kV 24 kV
2500 A
1600 A 20 to 34 kA*
15 to 30 kA*
400 A
HVX
PE90548
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV 20 kV 24 kV
2500 A
1600 A 20 to 34 kA*
15 to 30 kA*
400 A
Offer extension
PE90549
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-54
Medium Voltage Distribution MV CB or Contactor or Disconnector
WBA
To give a new life to your installations
Original brand:
AEG VA (Vacuum)
Version type:
withdrawable
VAA (Vacuum) VA (Vacuum)
device compatible ECA (Vacuum) VAA (Vacuum)
with WBA cubicles BAL (Vacuum)
PE90665
PE90657
Rated Voltage Un (50/60 Hz)
12 to 24 kV 12 to 24 kV 12 to 38 kV
1250 A to 2500 A
ECA (20 to 50 kA*) VA (20 to 50 kA*)
630 A to 1250 A VAA (16 to 25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90664
Rated Voltage Un (50/60 Hz)
12 to 24 kV 12 to 38 kV
1600 A to 2500 A
VA (20 to 50 kA*)
630 A to 1600 A VAA (16 to 25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90657
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-55
Medium Voltage Distribution MV CB or Contactor or Disconnector
WBB
To give a new life to your installations
Original brand:
AEG VA (Vacuum)
Version type: VA (Vacuum)
VAA (Vacuum)
withdrawable VAA (Vacuum)
device compatible ECA (Vacuum)
with WBB cubicles
PE90663
12 to 24 kV 12 to 24 kV 12 to 38 kV
1250 A to 2500 A
ECA (20 to 50 kA*) VA (20 to 50 kA*)
630 A to 1250 A VAA (16 to 25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90663
PE90664
Rated Voltage Un (50/60 Hz)
12 to 24 kV 12 to 38 kV
1200 A to 2500 A
VA (20 to 50 kA*)
630 A to 1200 A VAA (16 to 30 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90660
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-56
Medium Voltage Distribution MV CB or Contactor or Disconnector
WKC
To give a new life to your installations
Original brand:
AEG VA (Vacuum)
Version type: FPX (SF6)
VAA (Vacuum)
withdrawable VA (Vacuum)
device compatible MC (Vacuum)
VAA (Vacuum)
with WKC cubicles BAL (Vacuum)
PE90661
12 to 24 kV 12 to 38 kV
1250 A to 2500 A
VA (20 to 50 kA*)
630 A to 1250 A VAA (16 to 25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90661
PE90650
3.6 to 7.2 kV 7.2 to 24 kV 12 to 24 kV 12 to 38 kV
2500 A to 4000 A
FPX (31.5
1600 A to 2500 A to 40 kA*)
1250 A to 1600 A VA
630 A to 1250 A VAA (20 to 50 kA*)
(16 to 25 kA*)
400 A Contactor
Vacuum
(16 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90662
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-57
Medium Voltage Distribution MV CB or Contactor or Disconnector
YSF6
To give a new life to your installations
Original
brand: Yorkshire
YSF6 (SF6) YSF6 Evolis (Vacuum)
Switchgear /
Merlin Gerin
Version type:
withdrawable
device compatible
with YSF6 cubicle
PE90608
YSF6
Rated Voltage Un (50/60 Hz)
12 kV
630 A to 1250 A Up to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
YSF6 Evolis
PE90609
Rated Voltage Un (50/60 Hz)
12 kV
630 A to 1250 A Up to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
1981 2001
Offer extension
PE90419
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-58
B-59
Medium Voltage Distribution MV Panel
D-12
To give a new life to your installations
Original brand:
AEG
Version type: D-12 D-12
Air Insulated
Switchgear
PE90648
D-12
Rated Voltage Un (50/60 Hz)
12 kV
1600 A 25 to 31.5 kA*
630 A to 1250 A 20 to 25 kA*
Rated Current (Ir) PE90648
1994 2004
Offer extension
PE90648
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-60
Medium Voltage Distribution MV Panel
D-24
To give a new life to your installations
Original brand:
AEG
Version type: D-24 D-24
Air Insulated
Switchgear
PE90649 D-24
Rated Voltage Un (50/60 Hz)
24 kV
630 A to 1250 A 10 to 25 kA*
Rated Current (Ir) PE90651
1994 2004
Offer extension
PE90649
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-61
Medium Voltage Distribution MV Panel
F100/200
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: F100/200 F100/200
Air Insulated
Switchgear
7.2 kV 12 kV 17.5 kV
630 A to 3150 A F100 F200
(25 to 50 kA*) (25 to 50 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90645
F100/200
Incomer / Feeder / Coupling (arc proof in option)
Rated Voltage Un (50/60 Hz)
7.2 kV 12 kV 17.5 kV
630 A to 3150 A 25 to 50 kA*
PE90644
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90645
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-62
Medium Voltage Distribution MV Panel
F100C
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: F100C F100C
Air Insulated
Switchgear
PE90645
F100C
Rated Voltage Un (50/60 Hz)
7.2 kV
630 A to 2500 A 8 to 50 kA* (with fuses)
PE90644
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90645
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-63
Medium Voltage Distribution MV Panel
PX12-24
To give a new life to your installations
Original brand:
Alstom
Version type: PX 12-24 PX 12-24
Air Insulated
Switchgear
12 kV 24 kV
2500 A to 3150 A
PX 12 (25 to 40 kA*)
400 A to 2500 A PX 24 (16 - 25 - 31.5 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
12 kV 24 kV
2500 A to 3150 A
PX 12 (25 to 40 kA*)
400 A to 2500 A PX 24 (16 - 25 - 31.5 kA*)
PE90677
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90677
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-64
Medium Voltage Distribution MV Panel
R
To give a new life to your installations
Original brand:
AEG
Version type: R R
Air Insulated
Switchgear
PE90655
R
Rated Voltage Un (50/60 Hz)
12 kV 24 kV
400 A to 2500 A 20 to 40 kA* 16 to 25 kA*
PE90655
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90655
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-65
Medium Voltage Distribution MV Panel
VMX
To give a new life to your installations
Original brand:
GEC, GEC
Alstom, Alstom VMX (Vacuum) VMX (Vacuum)
Version type:
Air Insulated
Switchgear.
Withdrawable
vacuum
switchgear Main technical characteristics
VMX
PE90692
VMX
Rated Voltage Un (50/60 Hz)
11 kV
630 A - 800 A -
Up to 25 kA* for 3s
1250 A - 2000 A
PE90692
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90692
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-66
Medium Voltage Distribution MV Panel
WBA
To give a new life to your installations
Original brand:
AEG
Version type: WBA WBA
Air Insulated
Switchgear
PE90657
PE90657 * Intensity short circuit (Isc)
WBA
Rated Voltage Un (50/60 Hz)
12 to 24 kV 12 to 38 kV
1600 A to 2500 A
20 to 50 kA*
630 A to 1600 A 16 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90657
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-67
Medium Voltage Distribution MV Panel
WBB
To give a new life to your installations
Original brand:
AEG
Version type: WBB WBB
Air Insulated
Switchgear
PE90660
PE90659
12 to 24 kV 12 to 38 kV
1250 A to 2500 A 20 to 50 kA*
20 to 50 kA*
630 A to 1250 A 16 to 25 kA* & 20 to 50 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
WBB
Rated Voltage Un (50/60 Hz)
12 to 24 kV 12 to 38 kV
1200 A to 2500 A
20 to 50 kA*
630 A to 1200 A 16 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
Offer extension
PE90660
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-68
Medium Voltage Distribution MV Panel
WKC
To give a new life to your installations
Original brand:
AEG
Version type: WKC WKC
Air Insulated
Switchgear
12 to 24 kV 12 to 38 kV
1250 A to 2500 A
20 to 50 kA*
630 A to 1250 A 16 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90661 WKC
Rated Voltage Un (50/60 Hz)
Offer extension
PE90662
PE90437
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
B-69
PE90457
TM
ECOFIT
Protection
relays
ECOFITTM Protection relays
Generic offer
All C-2
Specific offer
KCGG 122&142 C-3
SEPAM 2000 C-4
VIP11R & VIP12R C-5
Protection upgrade benefits C-6
C-1
Protection relays Generic offer
All
To give a new life to your installations
Original brand:
all brands MiCOM
Version type: Old types
Sepam
protection relays
compatible
with all MV
switchboard
PE90437
PE90487
MiCOM P series 10 - 20 - 30 - 40
PE90488
Sepam series 10 - 20 - 40 - 60 - 80
PE90449
PE90438
'LUHFWLRQDOSURWHFWLRQ
PE90488
&ODVVLFDXWRPDWLRQ*RRVH0HVVDJHV
'LfIHUHQWLDOGLVWDQFHFRPSOH[DXWRPDWLRQ
C-2
Protection relays Specific offer
KCGG122 & 142
To give a new life to your installations
Original brand:
Alstom
Version type:
KCGG 122 & 142 MiCOM P123R
draw-out
PE90634
PE90634
Case
Installation Withdrawable case
Language English
Communication KBus / Courier
Power supply 24 V / 125 VDC - 48 V / 250 VDC
Digital input supply 48 VDC only
PE90635
MiCOM P123R
Case
Installation Withdrawable case
Language Multilanguage
Communication KBus / Courier, DNP3, IEC60870-5-103
Power supply 24 V / 250 VDC - 48 V / 240 VDC
Digital input supply According to Power Supply (above)
2011 ECOFIT
Ongoing
C-3
Protection relays Specific offer
Sepam 2000
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
Sepam 2000 Sepam serie 60/80
Sepam 2000
series
PE90638
PE90638
PE90639
Sepam Sepam
Sepam 2000
serie 80 serie 60
Motor application M06, M07, M08, M14
M02 to M05, M09, M11, M15, M16,
M20 to M23
Substation S02, S03, S06 to S09
application
S01, S04, S05
Busbar application B02, B04, B07, B12
B01, B03
Transformer T01 to T03, T06, T07, T09, T10, T12 to T15,
application T17 to T19
without temp.
measurement T04, T05, T11, T16
Generator
G01 to G08, G12, G13, G15 to G18
application
Capacitor bank C02, C04, C06, C08
application
C01, C03
Transformer
D02, D22
diff. application
C-4
Protection relays Specific offer
VIP11R-12R for RM6+
To give a new life to your installations
Original brand:
Merlin Gerin VIP11R
Version type: ECOFITTM VIP11-12R
VIP11R or VIP12R
VIP12R
protection relays
compatible for
RM6 +
VIP11R
PE90568
or VIP12R
PE90570
PE90569
PE90569
ECOFIT™
VIP11-12R
C-5
Protection relays Protection upgrade benefits
Flexibility The integrated functions of the relay allow for communications and control
of the equipment either as a stand-alone unit or as part of networked systems.
All components in the protection chain are referenced and interface rapidly.
No constraints for integration in cubicles due to the compact size of the base unit.
Ease of use Settings and adjustments are entered via the device's keypad
and visually displayed.
C-6
Medium & Low Voltage Distribution
Modernisation of switchboards
TM
ECOFIT
Green is our colour
Catalogue 2013
Schneider Electric nv/sa Dieweg 3 Due to evolution of standards and equipment, the characteristics indicated in
B-1180 Bruxelles/Brussel text and images of this document do not constitute a commitment on our part
Tel.: (02) 373 75 01 without conformation.
be-aftersales.be@schneider-electric.com
www.schneider-electric.be
TVA/BTW: BE 0451.362.180
Printed on recycled paper