Вы находитесь на странице: 1из 112

PE90460

Medium & Low Voltage Distribution


Modernisation of switchboards
TM

ECOFIT Green is our colour


Catalogue 2013
TM

ECOFIT

Index

How to find an ECOFIT™ solution?


1. Select the " generic family "
(MV xxx, LV xxx or protection relay).
2. Select the " Panel type ".
3. Select the " Original device type ".

1
Original Brand MV CB or MV Panel LV CB or LV Drawer Protection Panel type Original New device Page
Contactor or Contactor relay device type type
Disconnector
Nuova Magrini  NA B Control Masterpact NW
A-2
Galileo
Merlin Gerin  NA Compact Compact NS
A-3
C801-C1251
Merlin Gerin  NA DA Masterpact NW
A-4

Square D  NA DS Masterpact NW
A-5

Federal Pioneer  NA H series Masterpact NT


A-6
- NW
Merlin Gerin  NA Masterpact M Masterpact NW
A-7

Square D,  NA SE Masterpact NW
A-8
Westinghouse
Merlin Gerin  NA Selpact Masterpact NT
A-9
- NW
Unelec-Areva  Normabloc 660 Unelec CNP Masterpact NW
A-10

Merlin Gerin  NA Visucompact Masterpact NW


A-11
CM
Merlin Gerin  MB400 MB400 MB400 drawers
A-13
drawers
Merlin Gerin  T140 T140 drawers T140 drawers
A-14

Square D  5-15 kV MC VAD2-3 Magnum CB


B-2
switchgear
Concordia  All AEG TG TG
B-3
Sprecher cubicles
Merlin Gerin  Belledonne DSE22 to LF2 - LF3 - SF1
B-4
B200-B400 DSE78 - Evolis
Merlin Gerin  Belledonne DSE22K- LF1 - Evolis
B-5
B200G DSE23K
Merlin Gerin  Belledonne DIS LF1 - R400 -
B-6
B650 R400D - Evolis
Merlin Gerin  Belledonne DIS SF1
B-7
B900
AEI,  BVP 17 BVP 17 VMX
B-8
GEC Alsthom
CEM  CEMABLOC- CB FP
B-9
C23mc 15 & 27
CEM  CEMABLOC- CB HVX
B-10
C23mc 15 & 27
CEM  CEMAFLUOR- CS FPR
B-11
C26.0
Merlin Gerin  Chamrousse DIS LF2 - R400 -
B-12
R400D
Nuova Magrini  Composit MG SF1
B-13
Galileo
VEB  CSIM 1-12 SCI-4 VEIVACUUM F
B-14
Otto Buchwitz
VEB “Otto  CSIM 3-12 SCI-4 VEIVACUUM F,
B-15
Buchwitz” VA10031
AEG  D-12 BAL, VAA, VA VAA, VA
B-16

AEG  D-24 BAL, VAA VAA


B-17

Alsthom  DNF4-2E FP, GFA FP, HVX, CVX


B-18

Alsthom  DNF4 MI&FI FP FP, HVX


B-19

Alsthom  DNF5/DNF5- FP FP, HVX


B-20
2B
Alsthom  DNF6 FP FP, HVX
B-21

Alsthom  DNF7 FP FP, HVX-O2


B-22

Nuova Magrini  Epoclad DHF-F LF1 - LF2 - LF3


B-23
Galileo - SF1
Merlin Gerin  Fluair FG1-FG2 LF2 - LF3 -
B-24
F100-F200 Evolis
Merlin Gerin  Fluair F100C R400-R400D R400 - R400D
B-25

Merlin Gerin  Fluair F400C FC4 SF2


B-26

Merlin Gerin  Fluair F400G FG4 SF1 - SF2


B-27

Delle Alsthom  FLUOMATIC FR62 FP62


B-28
F540
Delle Alsthom  FLUOMATIC FR62 BLV
B-29
F943
AEG  GS-10 GE VA - VAA
B-30

GEC Alstom  HMC 400 & HMC 400 - HMC 400 -


B-31
HMC 410 HMC 410 HMC 410

2
Original Brand MV CB or MV Panel LV CB or LV Drawer Protection Panel type Original New device Page
Contactor or Contactor relay device type type
Disconnector
GEC Alstom  HMC 1072 HMC 1072 HMC 1072
B-32

GEC Alstom  HMC 1172 HMC 1172 HMC 1172


B-33

GEC Alstom  HMX 36 HMX 36 HMX 36


B-34

CEM  KIT 25-PGDt CC FP


B-35

CEM  KIT 27.2-PGHt HF4K FP


B-36

AEG  L D-E HVX


B-37

Federal Pioneer  Metalclad DST 2 & 5 DST 2V & 5V


B-38
switchgear
Merlin Gerin  Motorstart KA-KDA R400 - R400D
P12D-P30D B-39

Merlin Gerin  Motorstart C-CD R400 - R400D -


B-40
P50D CTV1
Merlin Gerin  Motorstart C1-CD1 R400 - R400D -
B-41
P500D CTV1
GEC Alstom  MX 51 & MX MX 51 - MX MX 51 - MX 81
B-42
81 81
Delle Alsthom  NORMABLOC HL HVX - FPX
B-43
N1347
Delle Alsthom  NORMASEPT HL FP
B-44
N743
Concordia  PA, SC, SD HP T/W/Z HVX
B-45
Sprecher
AEG  R E-M VA - VAA
B-46

Ansaldo  Siclad MAG II LF2


B-47

Square D  Solenarc DSE DSE Magnum CB


Metal-Clad B-48
switchgear
Merlin Gerin  Taillefer DST LF3
B-49
T900-T1080
Nuova Magrini  Venus GI-GL LF1-LF3
B-50
Galileo
Merlin Gerin  VM6 DM12 FB4 SF1
B-51

Merlin Gerin  VM6 DM22- FB4 SF1


B-52
DM23
GEC, GEC  VMX VMX VMX
B-53
Alstom, Alstom
AEG  WAK D-E HVX
B-54

AEG  WBA VA, VAA, VA, VAA


B-55
ECA, BAL
AEG  WBB VA, VAA, ECA VA, VAA
B-56

AEG  WKC VA, VAA, MC, FPX, VA, VAA


B-57
BAL
Yorkshire  YSF6 YSF6 YSF6 Evolis
B-58
Switchgear
AEG  D-12 D-12 panel D-12 panel
B-60

AEG  D-24 D-24 panel D-24 panel


B-61

Merlin Gerin  F100/200 F100/200 F100/200 panel


B-62
panel
Merlin Gerin  F100C F100C panel F100C panel
B-63

Alstom  PX 12-24 PX 12-24 PX 12-24 panel


B-64
panel
AEG  R R panel R panel
B-65

GEC, GEC  VMX VMX panel VMX panel


B-66
Alstom, Alstom
AEG  WBA WBA panel WBA panel
B-67

AEG  WBB WBB panel WBB panel


B-68

AEG  WKC WKC panel WKC panel


B-69

All  All All MiCOM -


C-2
Sepam
GEC Alstom,  All KCGG 122 MiCOM P123R
C-3
Areva & 142
Merlin Gerin  All Sepam 2000 ECOFIT™
C-4
Sepam 2000
+
Merlin Gerin  RM6 VIP11R & ECOFIT™
C-5
VIP12R VIP11-12R
* Not current ECOFIT™ reference centre

3
PE90457

4
TM

ECOFIT

Contents
ECOFITTM
Contents

Low Voltage Distribution A-1

Medium Voltage Distribution B-1

Protection relays C-1

5
TM

ECOFIT

What does
that mean?

6
Schneider Electric is helping
you get the most of your
equipment and installations
Installation Services
Assessment Maintenance
contract

Installation &
Commissioning
End-of-life

Technical Training

Modernisation

On-demand
Maintenance

ECOFITTM is the economical


complement to maintenance
operations
It prolongs your switchgear’s lifetime.

"Green is our colour" - ECOFIT TM


is the most economical means of reducing your network’s environmental
footprint without buying a whole new system
7
Presentation of the offer
Introduction

Today, the productivity, operating safety, continuity of service and availability requirements of installations
are such that at all levels of a company, the quest for high performance is a major consideration.

Taillefer, Fluair and Vercors cubicles and more than 3000 low-voltage retrofits on T140, T12 and
Masterbloc switchboards has enabled the Center to acquire the expertise and know-how required
to help you secure the loyalty of your customers.

p Supplying spare parts,


p Modifying cubicles,
p Replacing protective devices,
p Replacing original devices with latest-generation devices.

There are various ways of replacing old devices. The most usual methods are:

Retrofit: the original circuit breaker and its truck are replaced
p The connection interfaces (power and low voltage) are adapted for use on the original cubicle.
p The new circuit breaker is fitted with the new interfaces.
p The solution is tested mechanically with the mounting jig.

Retrofil: the original truck is retained and fitted with a new circuit breaker
p The original truck is renovated.
p The power interfaces are either retained and renovated or they are recreated.
p The new circuit breaker is adapted for mounting on the original truck.
p The solution is tested mechanically with the mounting jig.

solutions in order to provide you with constant support and help in ensuring customer satisfaction.
We pay particular attention to quality, which is our major consideration.

8
Presentation of the offer
Renovation solutions

Scope of the offer


Switchboard renovation
p Progressive replacement without modification of customers’ equipment:
renovation of medium and low voltage switchgear,
kits for improving equipment.
p Complete replacement or addition of cubicles by extension:
insertion of cubicles into the switchboard with connection ducts,
addition at the end of the switchboard of cubicles identical to the initial cubicle,
in accordance with floor space constraints.
Switchgear renovation
Replacement of old medium and low voltage switchgear and protection devices
by retrofit/retrofil solutions.
Supply of spare parts
Ensure the supply of spare parts for equipment that is no longer commercialized
by the equipment-producing departments.

Cost-effective solutions to fit your needs


p No break in continuity of service,
p No added civil engineering work,
p No modification of your equipment,
p Operating constraints taken into account,
p Progressive renovation to fit your budget.

Validated and tested solutions


p Manufacturer’s warranty on renovated equipment,
p Factory-validated and tested equipment.

New solutions
p Compliant with the standards in effect,
p Integration of new-generation products,
p Evolving device technology.

9
Presentation of the offer
Product life cycle

There are four major phases in the product life cycle:

Commercialization period
The product is launched on the market and is included in the Schneider Electric catalogue.
The supply of spare parts is guaranteed.

Guaranteed spare parts supply period


The product is withdrawn from the market.
Schneider Electric continues to supply spare parts for a limited period of time.
Generally speaking, the average guaranteed spare part supply period
after the end of commercialization is :
p medium voltage: 12 years
p low voltage power: 10 years
p compact (accessories - devices): 3 years
p electronic equipment: according to the range
When the end of the guarantee period is reached, the product is considered to be expired.

Non-guaranteed spare parts supply period


As of the expiry date, the product is considered to be expired.
Spare part stock and supply are no longer guaranteed after the expiry date.
This period ends on the date on which the spare part offer is ended.
On that date, the stocks are entirely destroyed as well as the manufacturing tools.

Predicted end of
spare part offer

Expiry

Start of End of
commercialization commercialization

Prices and
delivery times

Spare parts Spare parts


End of supply supply
commercialization guaranteed not guaranteed Time

Switchgear retrofit

Device retrofit period


Commercialization of a retrofit offer for the replacement of old switchgear and protection devices.
The supply of retrofits will stop at the end of the commercialization of the new devices used.
The spare parts for these retrofits will therefore be handled as described above.

10
TM

COFIT EOL

EOL,
the complementary
offer

12
12 11
End-of-life:
environment in mind!

In complement to ECOFIT™, EOL proposal:


recovery and recycling for re-use of all
medium-voltage equipment, including SF6 gas
if applicable, metallic parts and accessories.

’ 98% of a medium-voltage cubicle can be recovered

’ legal
a SF6 requirement for the , an

environmental duty

1. Recovery of medium-voltage equipment from the customer’s site.


2. Dismantling of the equipment in a Schneider Electric factory. The different
ferrous and non-ferrous materials (copper, aluminium, etc.) are separated and
sent to specialised recycling centres.

3. When applicable, the SF6 is evacuated until the residual pressure is


less than 20 mbar, in accordance with the IEC standard, using adequate
EOL's engineered tools. The gas is stored in bottles before being sent for recycling.
The epoxy enclosure is crushed for recovery purposes.
4 steps
4. A certificate of destruction compliant with the regulations is sent to
the customer.

12
Benefit from
Schneider Electric’s
image and know-how
Quality & Environment
PE56733

Schneider Electric undertakes to reduce the


energy bill and CO2 emissions of its customers
by proposing products, solutions and services
which fit in with all levels of the energy value
chain.
At the same time, Schneider Electric strives
to reduce the environmental impact of
its products throughout their entire life-cycle
(from cradle to grave), particularly through
eco-design and eco-production.

14 13
Schneider Electric’s policy has always been to provide
Our common values : its customers with very close support in their daily
activities to enable them to achieve operational
’ Quality excellence.

’ Safety
’ Professionalism a world leader in Low & Medium
The experience of

Voltage
Schneider Electric has been manufacturing LV and MV products for
5% of sales more than 50 years and its installed base amounts to thousand millions
products and devices.
devoted to R & D The Schneider Electric brand is known worldwide and recognized
by the most demanding customers.

Local support
all over the world.
There are always A long history of innovation
Schneider Electric people for a global offer
close to you: Based on this experience as world leader, Schneider Electric has
developed a large and comprehensive range of innovative devices.

6200 Services people With one of the world leaders, you take benefit of a global leader
experience and know-how in electric distribution, automation and Power
& control.
in more than All the devices included in this overview have been designed
and manufactured to incorporate the benefits of this extensive
88 countries! experience.

More than
23,000 ECOFITTM in
services/delivered Schneider Electric
in various business segments
a brand you can trust

14
15
PE90457

TM

ECOFIT

Low Voltage
Distribution
ECOFITTM Low Voltage Distribution

LV CB or Contactor
B Control A-2
Compact C801-C1251 A-3
DA A-4
DS A-5
H series A-6
Masterpact M A-7
SE A-8
Selpact A-9
Unelec CNP A-10
Visucompact CM A-11
Associated offers -
Energy Management A-12
Associated offers -
Source-changeover systems A-12

LV Drawer
MB400 A-13
T140 A-14
Offer Extension -
Drawer components A-15

A-1
Low Voltage Distribution LV CB or Contactor
B Control
To give a new life to your installations
Original brand:
Nuova Magrini B Control Masterpact NT/NW
Galileo
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

Main technical characteristics


Rated Voltage Un (50/60 Hz)

220 V - 660 V
800 A to B1-35 / B1-50 B2-50 B3-50 / B3-75 / B4-100
PE90573
4000 A (35 - 52 kA*) (40 - 55 kA*) B3-90 (50 - 90 kA*) (50 - 100 kA*)
PE90573
Rated Current (Ir)
* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)

220 V - 660 V
800 A to Masterpact Masterpact NT / NW
4000 A NT/ NW (42 - 150 kA*)
(42 - 50 kA*)
PE90574
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1972 1990 2008

2009 ECOFIT Ongoing


Masterpact NT/NW

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
’C][[c\WQObW]\

A-2
Low Voltage Distribution LV CB or Contactor
Compact C801-C1251
To give a new life to your installations
Original brand:
Merlin Gerin C801 to C1251N/H Compact NS
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

Main technical characteristics


C801 to C1251N/H
Rated Voltage Un (50/60 Hz)
220 V 240 V 380 V 415 V 440 V 500 V 525 V 660 V 690 V
800 A to 42 to 40 to 25 to
1250 A 85 to 100 kA* 50 to 70 kA*
65 kA* 50 kA* 40 kA*
PE90430 PE90430 PE90572
Rated Current (Ir)
* Intensity short circuit (Isc)

Compact NS
Rated Voltage Un (50/60 Hz)
220 V 240 V 380 V 415 V 440 V 500 V 525 V 660 V 690 V
800 A to 50 to
1250 A 50 to 70 kA* 40 to 50 kA* 30 to 42 kA*
65 kA*
PE90431 059782N
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1993 2007 2009

2009 ECOFIT Ongoing


Compact NS

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
’C][[c\WQObW]\

A-3
Low Voltage Distribution LV CB or Contactor
DA
To give a new life to your installations
Original brand:
Merlin Gerin DSA1 / DNA1 / DSA2 / DNA2 / DRA / DNAH Masterpact NW
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

Main technical characteristics


DSA1 / DNA1 / DSA2 / DNA2 / DRA / DNAH
Rated Voltage Un (50/60 Hz)
220 V 415 V 440 V 500 V 525 V 600 V 660 V 690 V
630 A to 42 to 42 to
42 to 100 kA*
6300 A 100 kA* 85 kA*
PE90424
Rated Current (Ir) PE90424

* Intensity short circuit (Isc)

Masterpact NW
Rated Voltage Un (50/60 Hz)
220 V 415 V 440 V 500 V 525 V 600 V 660 V 690 V
800 A to 42 to 42 to
42 to 150 kA*
6300 A 130 kA* 100 kA*
630 A PE90427

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1968 1986 2009

1997 ECOFIT Ongoing


Masterpact NW

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wba;SOacrS[SntaO\R^rotSQbW]\a p. A-12
’C][[c\WQObW]\

Source-changeover systems p. A-12

A-4
Low Voltage Distribution LV CB or Contactor
DS
To give a new life to your installations
Original brand:
Square D, DS Masterpact NW
Westinghouse
Version type:
draw-out or fixed

PE90536 Main technical characteristics


DS-206

PE90537
Rated Voltage Un (50/60 Hz)
690 V
800 A 42 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

Masterpact NW

PE90429
Rated Voltage Un (50/60 Hz)
690 V
800 A 42 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1983 1998 2013

2007 ECOFIT Ongoing


Masterpact NW

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wba;SOacrS[SntaO\R^rotSQbW]\a p. A-12
’C][[c\WQObW]\

A-5
Low Voltage Distribution LV CB or Contactor
H series circuit breaker
To give a new life to your installations
Original brand:
Federal Pioneer H series Masterpact NT/NW
Version type:
draw-out

Main technical characteristics


H series H-3 HL-3 H-2 HL-2 100HF-1
Rated Voltage Un (50/60 Hz)
600 V
5000-6000 A 85 kA*
4000 A 85 kA* 85 kA* (1) 85 kA* 85 kA* (1)
3200 A 75 kA* 75 kA* (1)
3000 A 50 - 75 kA* 65 kA* (1) 65 - 75 kA* 65 kA* (1) 100 W -
2000 A 50 - 65 kA* 50 kA* (1) 50 - 65 kA* 65 kA* (1) Fuses
1600 A 42 - 50 - 65 kA* 50 kA* (1) 50 kA* 50 kA* (1) 50 kA* (1)
PE90615
(1) (1)
800 A 30 - 42 - 50 kA* 30 kA* 42 kA* 42 kA*
600 A 30 - 42 - 50 kA* 30 kA* (1) 42 kA* 42 kA* (1) 42 kA* (1) PE90615

Rated Current (Ir)


* Intensity short circuit (Isc) - (1) 200 kA with fuse

Masterpact NT Masterpact NW
Rated Voltage Un (50/60 Hz)
600 V
2500 A to 6000 A 200 kA*
N/A 42 kA* - 50 kA* -
1600 A to 2000 A with fuse
85 kA* - 130 kA*
800 A to 1200 A 35 to 50 kA* (Cradle & Cradle only)
PE90616

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1960 2003 2013

2001 ECOFIT Ongoing


Masterpact NT-NW

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
’C][[c\WQObW]\

A-6
Low Voltage Distribution LV CB or Contactor
Masterpact M
To give a new life to your installations
Original brand:
Merlin Gerin M08 to M63 Masterpact NW
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

Main technical characteristics


M08 to M63
Rated Voltage Un (50/60 Hz)
220 V 415 V 440 V 500 V 525 V 600 V 660 V 690 V
800 A to
40 to 150 kA* 40 to 85 kA*
035928 6300 A
Rated Current (Ir) 035928

* Intensity short circuit (Isc)

Masterpact NW
Rated Voltage Un (50/60 Hz)
220 V 415 V 440 V 500 V 525 V 600 V 660 V 690 V
800 A to 42 to 42 to
42 to 150 kA*
6300 A 130 kA* 100 kA*
PE90429
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1986 2003 2006

2004 ECOFIT Ongoing


Masterpact NW

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wba;SOacrS[SntaO\R^rotSQbW]\a p. A-12
’C][[c\WQObW]\

Source-changeover systems p. A-12

A-7
Low Voltage Distribution LV CB or Contactor
SE
To give a new life to your installations
Original brand:
Square D SE Masterpact NW
Version type:
draw-out or fixed

Main technical characteristics


SE
PE90538
Rated Voltage Un (50/60 Hz)
240 V 480 V 600 V
3000 A
800 A to 200 kA* 150 kA* 100 kA*
PE90538
1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

Masterpact NW
Rated Voltage Un (50/60 Hz)
240 V 480 V 600 V
3000 A
800 A to 100 kA* 85 kA*
PE90435
1250 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1983 2003 2011

2010 ECOFIT Ongoing


Masterpact NW

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
’C][[c\WQObW]\

A-8
Low Voltage Distribution LV CB or Contactor
Selpact
To give a new life to your installations
Original brand:
Merlin Gerin DN2 / DS2 / DR2 / DRS2 Masterpact NW
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

Main technical characteristics


DN2 / DS2 / DR2 / DRS2
Rated Voltage Un (50/60 Hz)
220 V 415 V 440 V 500 V 525 V 600 V 660 V 690 V
630 A to 42 to 42 to
PE90424 42 to 100 kA*
6300 A 100 kA* 85 kA*
Rated Current (Ir) PE90428

* Intensity short circuit (Isc)

Masterpact NT / NW
Rated Voltage Un (50/60 Hz)
220 V 415 V 440 V 500 V 525 V 600 V 660 V 690 V
630 A to 42 to 42 to
42 to 150 kA*
6300 A 130 kA* 100 kA*
PE90426
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1973 1989 2009

1997 ECOFIT Ongoing


Masterpact NT / NW

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
’C][[c\WQObW]\

Source-changeover systems p. A-12

A-9
Low Voltage Distribution LV CB or Contactor
Unelec CNP
To give a new life to your installations
Original brand:
Unelec - Areva CNP Masterpact NW
Version type:
fixed device.
Only for
Normabloc 660
switchboard

Main technical characteristics


CNP

PE90432
Rated Voltage Un (50/60 Hz)
660 V
PE90432
1250 A to 2000 A 36 to 100 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

Masterpact NW

PE90433
Rated Voltage Un (50/60 Hz)
690 V
1250 A to 2000 A 42 to 100 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1968 1986 2009

2007 ECOFIT Ongoing


Masterpact NW

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
’C][[c\WQObW]\

A-10
Low Voltage Distribution LV CB or Contactor
Visucompact CM
To give a new life to your installations
Original brand:
Merlin Gerin Visucompact CM Masterpact NW
Version
type: fixed and
withdrawable
device compatible
with all LV
switchboard

Main technical characteristics


Visucompact CM
Rated Voltage Un (50/60 Hz)
220 V 240 V 380 V 415 V 440 V

PE90434
1250 A to
85 kA* 70 kA* 65 kA*
2500 A
Rated Current (Ir) PE90434

* Intensity short circuit (Isc)

Masterpact NW
Rated Voltage Un (50/60 Hz)
220 V 240 V 380 V 415 V 440 V
1250 A to
42 to 100 kA*
2500 A
PE90435
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1985 2001 2005

2010 ECOFIT Ongoing


Masterpact NW

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-12
’C][[c\WQObW]\

A-11
Low Voltage Distribution LV CB or Contactor
Associated offers
Energy Management - Micrologic control units - Measurements and protections

Available
for ECOFIT™
solutions using
Masterpact
NT/NW and
Compact NS
Micrologic 2 5 6 7
Type A-E A-E-P-H A-E-P-H A-P-H
Functions Long time Long time Long time Long time
+ instantaneous + short time + short time + short time
+ instantaneous + instantaneous + instantaneous
+ earth fault + earth leakage up to 3200A

A: Current measurements, fault indications, display and current maximeter.

E: A + Instantaneous measurement of power and energy without earth leakage protection.


P: A + Calculation of power and energy value, voltage measurement, and programmable protection
H: P + Harmonics

Energy Management - Communication


Ɣ,GHQWLI\WKHGHYLFH 1
Ɣ,QGLFDWHVWDWXVFRQGLWLRQV
Available Ɣ&RQWUROWKHGHYLFH 24 V DC
for ECOFIT™ ZLWKWKHFRPPXQLFDWLQJDX[LOLDLULHV 
solutions using Ɣ6HWWLQJRIWKHSURWHFWLRQDQGDODUPVIXQFWLRQV
7
Masterpact
NT/NW and 1 Modbus network
Compact NS 2 &&0&KDVVLV
&RPPXQLFDWLRQ0RGXOH
2
8

3 %UHDNHU8QLYHUVDO/RJLF 3
Plug (ULP) cord
4 Breaker &RPPXQLFDWLRQ
0RGXOH %&0

5 Prefabricated wiring &RPSDFW16


5
6 Micrologic trip unit or Masterpact
1TRU1:
7 )'0GLVSOD\ 4 depending on
WKHGHYLFH

8 Line terminator
6

Source-changeover systems
Mechanical interlocking (2 types) Automatic controllers

Available for Using connecting rods or using IVE: Electrical interlocking BA or UA automatic controllers
cables
DA, Selpact and
Masterpact M
ECOFIT™
solutions using
Masterpact
NT/NW

A-12
Low Voltage Distribution LV Drawer
MB400
To give a new life to your installations
Original brand:
Merlin Gerin MB400 drawers MB400 drawers
Version type: for distribution for distribution
withdrawable & motor feeders & motor feeders
drawers
compatible
with MB400 LV
switchboards

Main technical characteristics


MB400 drawers
Rated Voltage Un (50/60 Hz)
440 VAC
625 A
PE90689
500 A
From 1 to 6 modules manually or electrically operated
250 A
125 A PE90685

Rated Current (Ir)

MB400 drawers
Rated Voltage Un (50/60 Hz)
440 VAC
625 A
500 A
From 1 to 6 modules manually or electrically operated
250 A
125 A
Rated Current (Ir)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1991 2003 2013

2003 ECOFIT Ongoing MB400 drawers


by Services

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-15
’C][[c\WQObW]\

A-13
Low Voltage Distribution LV Drawer
T140
To give a new life to your installations
Original brand:
Merlin Gerin T140 drawers T140 drawers
Version type: for distribution for distribution
withdrawable & motor feeders & motor feeders
drawers
compatible with
T140
LV switchboards

Main technical characteristics


T140 drawers
Rated Voltage Un (50/60 Hz)
440 VAC
625 A
PE90687
500 A
From 1 to 6 modules manually or electrically operated
250 A
125 A PE90685

Rated Current (Ir)

T140 drawers
Rated Voltage Un (50/60 Hz)
440 VAC
625 A
500 A
From 1 to 6 modules manually or electrically operated
250 A
125 A PE90685

Rated Current (Ir)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1975 1990 1998

1998 ECOFIT Ongoing T140 drawers


by Services

Associated offers
Energy Management
’;WQr]Z]UWQQ]ntr]Zc\Wta;SOacrS[SntaO\R^rotSQbW]\a p. A-15
’C][[c\WQObW]\

A-14
Low Voltage Distribution LV Drawer
Associated offers
Specific spare parts:

Available
for ECOFIT™
solutions using Drawer components
Masterpact
NT/NW and ’3ZSQb`WQOZRWab`WPcbW]\ºFc\QbW]\OZc\Wba<SX rO\US
Compact NS

Micrologic 2.2 or 2.3 5.2 or 5.3 6.2 or 6.3


Type A-E A-E
Functions LSI protection LSI protection LSI protection
Ammeter Ammeter
Energy meter Energy meter
A: Current measurements, fault indications, display and current maximeter
(residual or Source Ground Return); 7.0 provides earth leakage protection.
E: A + Instantaneous measurement of power and energy without earth leakage protection.

’;otor co\tr]ZQ][[O\RO\R^rotSQbW]\aºFc\QbW]\OZc\Wba
1 component motor feeder 2 components motor feeder 3 components motor feeder

Circuit breaker - Thermomagnetic circuit breaker + Thermomagnetic circuit breaker


Contactor combination Contactor or switch-disconnector fuse +
Contactor + Thermal protection

’Co\tr]ZQ][[O\ROcfWZWO`WSaf]`OZZtg^Saof drawers
Miniature circuit-breaker
Auxiliary relays
Protection auxiliary circuit

Ground fault protection Push buttons and lights

A-15
PE90457

TM

ECOFIT
Medium
Voltage
Distribution
ECOFITTM Medium Voltage Distribution

MV CB or Contactor or Disconnector
5-15 kV MC switchgear B-2
All AEG cubicles B-3
Belledonne B200-B400 B-4
Belledonne B200G B-5
Belledonne B650 B-6
Belledonne B900 B-7
BVP 17 B-8
CEMABLOC-C23mc 15 & 27 B-9
CEMABLOC-C23mc 15 & 27 B-10
CEMAFLUOR-C26.0 B-11
Chamrousse B-12
Composit B-13
CSIM 1-12 B-14
CSIM 3-12 B-15
D-12 B-16
D-24 B-17
DNF4-2E B-18
DNF4 MI&FI B-19
DNF5/DNF5-2B B-20
DNF6 B-21
DNF7 B-22
Epoclad B-23
Fluair F100-F200 B-24
Fluair F100C B-25
Fluair F400C B-26
Fluair F400G B-27
FLUOMATIC F540 B-28
FLUOMATIC F943 B-29
GS-10 B-30
HMC 400 & HMC 410 B-31
HMC 1072 B-32
HMC 1172 B-33
HMX 36 B-34
KIT 25-PGDt B-35
KIT 27.2-PGHt B-36
L B-37
Metalclad switchgear B-38
Motorstart P12D-P30D B-39
Motorstart P50D B-40
Motorstart P500D B-41
MX 51 & MX 81 B-42
NORMABLOC N1347 B-43
NORMASEPT N743 B-44
PA, SC, SD B-45
R B-46
Siclad B-47
Solenarc DSE Metal-Clad switchgear B-48
Taillefer T900-T1080 B-49
Venus B-50
VM6 DM12 B-51
VM6 DM22-DM23 B-52
VMX B-53
WAK B-54
WBA B-55
WBB B-56
WKC B-57
YSF6 B-58
MV Panel
D-12 B-60
D-24 B-61
F100/200 B-62
F100C B-63
PX 12-24 B-64
R B-65
VMX B-66
WBA B-67
WBB B-68
WKC B-69

B-1
Medium Voltage Distribution MV CB or Contactor or Disconnector
5-15 kV Metal-Clad Switchgear
To give a new life to your installations
Original brand:
Square D
Version type: VAD2
Magnum CB (Vacuum)
draw-out VAD3

Main technical characteristics


Rated Voltage Un (50/60 Hz)

PE90543
5 kV 15 kV
3000 A
2000 A VAD2 (29 kA*) VAD2 (18 - 28 kA*)
VAD3 (41 kA*) VAD3 (37 kA*)
1200 A

Rated Current (Ir)


PE90542
* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)

PE90544
5 kV 15 kV
3000 A
2000 A 5SSB (29 - 41 kA*) 15SSB (18 - 28 kA*)
15SSB (37 kA*)
1200 A

Rated Current (Ir)

* Intensity short circuit (Isc)

Magnum CB main
characteristics A true extended life time
Built with totally new Commercialisation End of End of End
components and tested to commercialisation spare parts of life
ANSI standards,
Magnum circuit breakers
< 1985 1995 2006
correctly interface with
the existing breaker
compartment components
and maintain safety 2004 ECOFIT Ongoing
Magnum CB
interlocks inherent
in the original equipment
design.
s New circuit breakers
are installed in existing
switchgear.
s Original footprint is left
intact, saving time and Offer extension
money.
s Installation expense is
a fraction of new
PE90461

equipment costs.
PE90437

- Less down time for


installation.
- Enhanced equipment
reliability.
s Manufactured with new MiCOM P series 10 - 20 - 30 - 40
components.
s Undergoes complete
factory testing.
PE90488

s Backed by our standard


equipment warranty.
s New, easy-to-maintain
operating mechanism.
s No bulky arc chutes
to handle and maintain. Sepam series 10 - 20 - 40 - 60 - 80
s Reduced need for difficult
to obtain spare parts.

B-2
Medium Voltage Distribution MV CB or Contactor or Disconnector
All AEG cubicles
To give a new life to your installations
Original brand:
Concordia
Sprecher TG TG
Version type:
disconnector
compatible with
all AEG cubicles
PE90656

Main technical characteristics


TG
Rated Voltage Un (50/60 Hz)

PE90656
12 kV 24 kV 36 kV
2500 A to 6300 A
15 to 63 kA* 16 to 31.5 kA*
630 A to 2500 A 19 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

TG
Rated Voltage Un (50/60 Hz)

PE90656
12 kV 24 kV 36 kV
2500 A to 6300 A
15 to 63 kA* 16 to 31.5 kA*
630 A to 2500 A 19 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1975 2006 Ongoing

2006 ECOFIT Ongoing


TG by Services

B-3
Medium Voltage Distribution MV CB or Contactor or Disconnector
Belledonne B200-B400
To give a new life to your installations
Original brand:
Merlin Gerin DSE22 LF2 (SF6), LF3 (SF6)
Version type: to SF1 (SF6)
withdrawable
DSE78 Evolis (Vacuum)
device
compatible with
Belledonne B200/ Main technical characteristics
B400 cubicles
DSE22 to DSE78
Rated Voltage Un (50/60 Hz)

PE90402
PE90400

7.2 kV 12 kV 17.5 kV 24 kV
3500 A
3150 A
3000 A 29 to 50 kA*
1250 A 24 to 48 kA* 15 to 46 kA* 10 to 29 kA*
630 A
Rated Current (Ir)
* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)

PE90401
7.2 kV 12 kV 17.5 kV 24 kV
3500 A
3150 A
LF2/LF3 LF2/LF3
3000 A (29 to 40 kA*)
(29 to 50 kA*)
Evolis Evolis
1250 A (40 kA*, SF1
(40 kA* - 2500 A max) (10 to 25 kA*)
630 A 2500 A max)
Rated Current (Ir)

* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1972 1986 2001

1988 ECOFIT Ongoing LF2, LF3 or SF1


Evolis

Offer extension
PE90400

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-4
Medium Voltage Distribution MV CB or Contactor or Disconnector
Belledonne B200G
To give a new life to your installations
Original brand:
Merlin Gerin DSE22K LF1 (SF6)
Version type: DSE23K Evolis (Vacuum)
withdrawable
device
compatible with
Belledonne
B200G
cubicles
Main technical characteristics
DSE22K to DSE23K

PE90405
PE90403

Rated Voltage Un (50/60 Hz)


7.2 kV
630 A to 1250 A 25 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

LF1 & Evolis

PE90404
Rated Voltage Un (50/60 Hz)
7.2 kV
630 A to 1250 A 25 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1971 1988 1992

1988 ECOFIT Ongoing LF1


Evolis

Offer extension
PE90393

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-5
Medium Voltage Distribution MV CB or Contactor or Disconnector
Belledonne B650
To give a new life to your installations
Original brand:
Merlin Gerin LF1 (SF6)
Version type: DIS R400 & R400D (SF6)
withdrawable Evolis (Vacuum)
device
compatible with
Belledonne B650
cubicles
Main technical characteristics

PE90398
DIS
PE90396

Rated Voltage Un (50/60 Hz)


7.2 kV
400 A to 1250 A 25 to 31.5 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)

R400 / R400D LF1 / Evolis

PE90398
Rated Voltage Un (50/60 Hz)
7.2 kV
630 A to 1250 A 31.5 kA
400 A to 630 A
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1958 1976 1992

1988 ECOFIT Ongoing LF1 / R400 / R400D /


Evolis

Offer extension
PE90393

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-6
Medium Voltage Distribution MV CB or Contactor or Disconnector
Belledonne B900
To give a new life to your installations
Original brand:
Merlin Gerin DIS SF1 (SF6)
Version type:
withdrawable
device
compatible with
Belledonne B900
cubicles
Main technical characteristics
DIS

PE90397
PE90396

Rated Voltage Un (50/60 Hz)


23 kV
400 A to 1250 A 12.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

SF1

PE90399
Rated Voltage Un (50/60 Hz)
24 kV
630 A to 1250 A 25 kA*
400 A to 630 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1961 1978 1992

1988 ECOFIT Ongoing


SF1

Offer extension
PE90393

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-7
Medium Voltage Distribution MV CB or Contactor or Disconnector
BVP 17
To give a new life to your installations
Original brand:
AEI, GEC, GEC
ALSTHOM BVP 17 (Oil) VMX (Vacuum)
Version type:
withdrawable
device compatible
with BVP 17
cubicles
Main technical characteristics

PE90605
BVP 17
PE90396

Rated Voltage Un (50/60 Hz)


11 kV
1250 A
800 A Up to 25 kA*
400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90606
VMX
Rated Voltage Un (50/60 Hz)
11 kV
1250 A
800 A Up to 25 kA*
400 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1965 1984 2006

2001 ECOFIT Ongoing


VMX

Offer extension
PE90604

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-8
Medium Voltage Distribution MV CB or Contactor or Disconnector
Cemabloc-C23mc 15 & 27
To give a new life to your installations
Original brand:
CEM
Version type: CB FP (SF6)
withdrawable
device
compatible with
CEMABLOC-
C23mc 15 et 27
cubicles
Main technical characteristics
CB

PE90462
Rated Voltage Un (50/60 Hz)
23 kV
400 A to 1250 A 12.5 - 16/25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90419

PE90463
FP
Rated Voltage Un (50/60 Hz)
23 kV
400 A to 1250 A 12.5 - 16/25kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1963 1984 1994

2010 ECOFIT Ongoing


FP

Offer extension
PE90461

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-9
Medium Voltage Distribution MV CB or Contactor or Disconnector
Cemabloc-C23mc 15 & 27
To give a new life to your installations
Original brand:
CEM
Version type: CB 6 poles HVX (Vacuum) 6 poles
withdrawable
device
compatible with
CEMABLOC-
C23mc 15 et 27
cubicles
Main technical characteristics

PE90464
CB
Rated Voltage Un (50/60 Hz)
23 kV
2500 A 12.5 - 16/25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90419

PE90465
HVX
Rated Voltage Un (50/60 Hz)
23 kV
2500 A 12.5 - 16/25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1963 1984 1994

2010 ECOFIT Ongoing


HVX

Offer extension
PE90461

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-10
Medium Voltage Distribution MV CB or Contactor or Disconnector
Cemafluor - C26.0
To give a new life to your installations
Original brand:
CEM
Version type: CS FPR (SF6)
withdrawable
device
compatible with
CEMAFLUOR
C26.0
cubicles
Main technical characteristics
CS

PE90467
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 1250 A 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90466

PE90468
FPR
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 1250 A 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1976 1982 1991

1985 ECOFIT Ongoing


FPR

Offer extension
PE90466

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-11
Medium Voltage Distribution MV CB or Contactor or Disconnector
Chamrousse
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
LF2 (SF6)
withdrawable DIS R400 (SF6)
device R400D (SF6)
compatible with
Chamrousse
cubicles

Main technical characteristics


DIS
Rated Voltage Un (50/60 Hz)

PE90447
7.2 kV 12 kV
630 A to 1250 A 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90446

Rated Voltage Un (50/60 Hz)

PE90448
7.2 kV 12 kV
630 A to 1250 A LF2 (25 kA*)
80 A to 250 A R400/R400D (10 kA*)
Rated Current (Ir)

* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1968 1974 1992

1989 ECOFIT Ongoing


LF2 / R400 / R400D

Offer extension
PE90446

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-12
Medium Voltage Distribution MV CB or Contactor or Disconnector
Composit 15-24 kV
To give a new life to your installations
Original brand:
Nuova Magrini
Galileo MG SF1 (SF6)
Version type:
withdrawable
device
compatible
with Composit Main technical characteristics
cubicles
MG

PE90576
PE90575

150-500 150-750 350-750 150-750 350-750

PE90576
Rated Voltage Un (50/60 Hz)
10 kV 15 kV 17 kV 20 kV 24 kV
630 to 1250 A 8.7 to 5 to 12.5 to 3.6 to 6.3 to
28.9 kA* 29 kA* 29 kA* 24 kA* 21.7 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

SF1**

PE90232
Rated Voltage Un (50/60 Hz)
10 kV 15 kV 17.5 kV 20 kV 24 kV
630 to 1250 A 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc) ** For Composit panel 860 mm wide

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1966 1993 2015

2000 ECOFIT Ongoing


SF1

Offer extension
PE90575

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-13
Medium Voltage Distribution MV CB or Contactor or Disconnector
CSIM 1-12
To give a new life to your installations
Original
brand: VEB “Otto
Buchwitz” SCI-4 VEIVACUUM F (Vacuum)
Starkstroman-
lagenbau Dresden
Version type:
withdrawable Main technical characteristics
device compatible

PE90561
with CSIM 1-12 SCI-4
cubicles Rated Voltage Un (50/60 Hz)
12 kV
PE90560

630 A to 1250 A 16 to 31.5 kA*


Rated Current (Ir)
* Intensity short circuit (Isc)

PE90562
VEIVACUUM F
Rated Voltage Un (50/60 Hz)
12 kV
630 A to 1250 A 16 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1975 1991

2009 ECOFIT Ongoing


VEIVACUUM F

Offer extension
PE90563

PE90643
PE90437

MiCOM P
series 10 - 20 - 30 - 40
PE90488

Sepam
series 10 - 20 - 40 - 60 - 80

B-14
Medium Voltage Distribution MV CB or Contactor or Disconnector
CSIM 3-12
To give a new life to your installations
Original
brand: VEB “Otto
Buchwitz”
VEIVACUUM F (Vacuum)
SCI-4
Starkstroman- VA 10031 (Vacuum)
lagenbau Dresden
Version type:
withdrawable Main technical characteristics
device compatible

PE90640
with CSIM 3-12 SCI-4
cubicles Rated Voltage Un (50/60 Hz)
12 kV
PE90640

630 A to 2500 A 16 to 31.5 kA*


Rated Current (Ir)
* Intensity short circuit (Isc)

PE90641
Rated Voltage Un (50/60 Hz)

12 kV
1600 A to 2500 A VA (16 to 31.5 kA*)
630 A to 1250 A VEIVACUUM F
(16 to 31.5 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1975 1981 1991

2012 ECOFIT Ongoing


VEIVACUUM F - VA

Offer extension
PE90563

PE90643
PE90437

MiCOM P
series 10 - 20 - 30 - 40
PE90488

Sepam
series 10 - 20 - 40 - 60 - 80

B-15
Medium Voltage Distribution MV CB or Contactor or Disconnector
D-12
To give a new life to your installations
Original brand:
AEG BAL
Version type: VAA (Vacuum)
VAA
withdrawable VA (Vacuum)
device compatible
VA
with D-12 cubicles
PE90648

Main technical characteristics

PE90648
Rated Voltage Un (50/60 Hz)

12 kV
1600 A VA (25 to 31.5 kA*)
200 A to 1250 A VAA (20 to 25 kA*) BAL (10 to 20 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)

PE90650
12 kV
1600 A VA (25 to 31.5 kA*)
630 A to 1250 A VAA (20 to 25 kA*)
Rated Current (Ir)

* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1994 2004 Ongoing

2004 ECOFIT Ongoing


VAA, VA

Offer extension
PE90649

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-16
Medium Voltage Distribution MV CB or Contactor or Disconnector
D-24
To give a new life to your installations
Original brand:
AEG BAL
Version type: VAA (Vacuum)
withdrawable
VAA
device compatible
with D-24 cubicles
PE90651

Main technical characteristics

PE90651
Rated Voltage Un (50/60 Hz)

24 kV
630 A to 1250 A VAA (16 to 25 kA*)
100 A to 630 A BAL (10 to 16 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90650
VAA
Rated Voltage Un (50/60 Hz)
24 kV
630 A to 1250 A 10 to 25 kA*
Rated Current (Ir)

* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1994 2004 Ongoing

2004 ECOFIT Ongoing


VAA, VA

Offer extension
PE90649

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-17
Medium Voltage Distribution MV CB or Contactor or Disconnector
DNF4-2E
To give a new life to your installations
Original brand:
Alsthom
FP (SF6)
Version type: FP (SF6)
withdrawable HVX (Vacuum)
GFA (SF6)
device compatible CVX (Vacuum)
with DNF4-2E
cubicles
PE90667

Main technical characteristics

PE90668
FP - GFA
Rated Voltage Un (50/60 Hz)
12 kV
400 A to 2000 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

FP - HVX - CVX

PE90669
Rated Voltage Un (50/60 Hz)
12 kV
400 A to 2000 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1983 1997 2007

2009 ECOFIT Ongoing FP


HVX - CVX

Offer extension
PE90670

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

PE90671

Sepam series 10 - 20 - 40 - 60 - 80

B-18
Medium Voltage Distribution MV CB or Contactor or Disconnector
DNF4 MI&FI
To give a new life to your installations
Original brand:
Alsthom
FP (SF6)
Version type: FP (SF6)
withdrawable HVX (Vacuum)
device compatible
with DNF4 MI&FI
cubicles
PE90671

Main technical characteristics


FP

PE90672
Rated Voltage Un (50/60 Hz)
12 kV
400 A to 2500 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

FP - HVX

PE90673
Rated Voltage Un (50/60 Hz)
12 kV
400 A to 2500 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1983 1997 2007

2010 ECOFIT Ongoing FP


HVX

Offer extension
PE90671

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-19
Medium Voltage Distribution MV CB or Contactor or Disconnector
DNF5/DNF5-2B
To give a new life to your installations
Original brand:
Alsthom
FP (SF6)
Version type: FP (SF6)
withdrawable HVX (Vacuum)
device compatible
with DNF5 /
DNF5-2B cubicles
PE90678

Main technical characteristics


FP

PE90672
Rated Voltage Un (50/60 Hz)
17.5 kV
630 A to 2000 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

FP - HVX

PE90673
Rated Voltage Un (50/60 Hz)
17.5 kV
630 A to 2000 A 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1983 1997 2007

2011 ECOFIT Ongoing FP


HVX

Offer extension
PE90678

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-20
Medium Voltage Distribution MV CB or Contactor or Disconnector
DNF6
To give a new life to your installations
Original brand:
Alsthom
FP (SF6)
Version type: FP (SF6)
withdrawable HVX (Vacuum)
device compatible
with DNF6 cubicles
PE90679

Main technical characteristics


FP

PE90680
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 2000 A 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

FP - HVX

PE90673
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 2000 A 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1987 1997 2007

2011 ECOFIT Ongoing FP


HVX

Offer extension
PE90679

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-21
Medium Voltage Distribution MV CB or Contactor or Disconnector
DNF7
To give a new life to your installations
Original brand:
Alsthom
FP (SF6)
Version type: FP (SF6)
withdrawable HVX-O2 (Vacuum)
device compatible
with DNF7 cubicles
PE90674

Main technical characteristics


FP

PE90675
Rated Voltage Un (50/60 Hz)
36 kV
400 A to 2000 A 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

FP - HVX-O2

PE90676
Rated Voltage Un (50/60 Hz)
36 kV
400 A to 2000 A 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1987 2010 Ongoing

06/2013 ECOFIT Ongoing FP


HVX-02

Offer extension
PE90674

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-22
Medium Voltage Distribution MV CB or Contactor or Disconnector
Epoclad
To give a new life to your installations
Original brand:
Nuova Magrini LF1 (SF6)
Galileo DHF LF2 (SF6)
Version type: F LF3 (SF6)
withdrawable
device
SF1 (SF6)
compatible with
Epoclad cubicles Main technical characteristics
Rated Voltage Un (50/60 Hz)

PE90578
6 kV 7.2 kV 10 kV 12 kV 15 kV 17 kV 20 kV 24 kV
PE90577

630 A to 20DHF
3150 A 350-750
6DHF 12F
6DHF/N 7F/N 10DHF 7F 15DHF 12F/N 24DHF (8 -
250-350 250-750 350-750 350-850 350-500 18 kA*)
250-500 350-750
(20 -
(29 - (12 - (18 - (13.5 -
(12.5 -
(9.2 - 24F
34 kA*) 43 kA*) 48 kA*) 32.5 kA*) 14.5 kA*) 500-750
48 kA*) 48 kA*)
(12.5 -
18 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)

PE90579
7.2 kV 12 kV 17.5 kV 24 kV
3150 A LF3 (50 kA*)
2000 A LF2 (50 kA*) LF3 (40 kA*)
630 A to LF2 (40 kA*)
1250 A
LF1 (31.5 kA*) SF1 (25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1969 1997 2015

2005 ECOFIT Ongoing


LF1, LF2, LF3, SF1

Offer extension
PE90577

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-23
Medium Voltage Distribution MV CB or Contactor or Disconnector
Fluair F100-F200
To give a new life to your installations
Original brand:
Merlin Gerin FG1 LF2 (SF6), LF3 (SF6)
Version type: FG2 Evolis (Vacuum)
withdrawable
device
compatible with
Fluair F100/200
cubicles
Main technical characteristics
PE90409

FG1 / FG2

PE90410
Rated Voltage Un (50/60 Hz)
7.2 kV 12 kV 17.5 kV
630 A to 3150 A 25 to 50 kA* 25 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)

PE90411
7.2 kV 12 kV 17.5 kV
630 A to 3150 A LF2/LF3 (25 to 50 kA*) LF2/LF3
(29 to 31.5 kA*)
Evolis (40 kA* - 2500 A max)
Rated Current (Ir)

* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1980 1998 2011

1999 ECOFIT Ongoing LF2, LF3


Evolis

Offer extension
PE90409

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-24
Medium Voltage Distribution MV CB or Contactor or Disconnector
Fluair F100C
To give a new life to your installations
Original brand:
Merlin Gerin R400 R400 (SF6)
Version type:
R400D R400D (SF6)
withdrawable
device
compatible with
Fluair F100C
cubicles
Main technical characteristics
R400 / R400D

PE90413
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90412
R400 / R400D

PE90413
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1980 1988
(always available)

ECOFIT Ongoing
R400 / R400D

Offer extension
PE90409

PE90437

MiCOM P
series 10 - 20 - 30 - 40
PE90488

Sepam
series 10 - 20 - 40 - 60 - 80

B-25
Medium Voltage Distribution MV CB or Contactor or Disconnector
Fluair F400C
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: FC4 SF2 (SF6)
withdrawable
device
compatible with
Fluair F400C
cubicles

Main technical characteristics


PE90415

PE90415
FC4
Rated Voltage Un (50/60 Hz)
36 kV
1250 A to 2500 A 31.5 to 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

SF2

PE90416
Rated Voltage Un (50/60 Hz)
36 kV
1250 A to 2500 A 31.5 to 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1980 1987 2000

1991 ECOFIT Ongoing


SF2

Offer extension
PE90415

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-26
Medium Voltage Distribution MV CB or Contactor or Disconnector
Fluair F400G
To give a new life to your installations
Original brand:
Merlin Gerin SF1 (SF6)
Version type: FG4
SF2 (SF6)
withdrawable
device
compatible with
Fluair F400G
cubicles

Main technical characteristics


PE90406

FG4
Rated Voltage Un (50/60 Hz)

PE90418
24 kV 36 kV
1250 A to 2500 A 40 kA* 25 to 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

SF1 / SF2

PE90450
Rated Voltage Un (50/60 Hz)
24 kV 36 kV
1250 A to 2500 A 40 kA* 25 to 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1986 2002 2009

2004 ECOFIT Ongoing


SF1/SF2

Offer extension
PE90406

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-27
Medium Voltage Distribution MV CB or Contactor or Disconnector
FLUOMATIC F540
To give a new life to your installations
Original brand:
Delle Alsthom
Version type: FR62 FP62 (SF6)
fixed device
compatible with
FLUOMATIC
F540 cubicles

Main technical characteristics

PE90470
FR62
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 16/25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90471
PE90469 FP62
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 16/25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1976 1984 1994

1992 ECOFIT Ongoing


FP62

Offer extension
PE90487

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-28
Medium Voltage Distribution MV CB or Contactor or Disconnector
FLUOMATIC F943
To give a new life to your installations
Original brand:
Delle Alsthom
Version type: FR62 BLV (SF6)
fixed device
compatible with
FLUOMATIC
F943
cubicles

Main technical characteristics


FR62

PE90470
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 1250 A 16 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90472

PE90474
BLV
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 1250 A 16 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1976 1984 1994

1997 ECOFIT Ongoing


BLV

Offer extension
PE90487

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-29
Medium Voltage Distribution MV CB or Contactor or Disconnector
GS-10
To give a new life to your installations
Original brand:
AEG
Version type: GE VA/VAA (Vacuum)
withdrawable
device
compatible with
GS-10 cubicles

Main technical characteristics


GE

PE90540
PE90550

Rated Voltage Un (50/60 Hz)


up to 12 kV
630 A to 3000 A 16 to 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

VA/VAA

PE90541
Rated Voltage Un (50/60 Hz)
up to 12 kV
630 A to 3000 A 16 to 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1966 1978 2011

2004 ECOFIT Ongoing


VA / VAA

Offer extension
PE90539

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-30
Medium Voltage Distribution MV CB or Contactor or Disconnector
HMC 400 & HMC 410
To give a new life to your installations
Original brand:
GEC Industrial HMC 400 (Vacuum) HMC 400 (Vacuum)
Controls,
HMC 410 (Vacuum) HMC 410 (Vacuum)
GEC, GEC
Alstom, Alstom
Version type:
withdrawable
vacuum motor
starter

Main technical characteristics


HMC 400 & HMC 410

PE90594
Rated Voltage Un (50/60 Hz)
3.3 kV 6.6 kV
PE90594 400 A 43.8 kA* 26.3 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

HMC 400 & HMC 410 Gemstart

PE90595
Rated Voltage Un (50/60 Hz)
3.3 kV 6.6 kV Motors up to 13.8 kV / 400 A.

(self selecting).
400 A 43.8 kA* 26.3 kA* Multi-Voltage Inputs from 24 V
to 256 V AC or DC.
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1960 1970 Ongoing

ECOFIT Ongoing
refurbishment,
using Gemstart unit

Refurbishment

In-house refurbishment, including vacuum contactors and


control scheme utlilising Gemstart unit, on site maintenance
B-31
Medium Voltage Distribution MV CB or Contactor or Disconnector
HMC 1072
To give a new life to your installations
Original brand:
GEC Industrial
Controls, GEC, HMC 1072 (Vacuum) HMC 1072 (Vacuum)
GEC Alstom,
Alstom
Version type:
withdrawable
vacuum motor Main technical characteristics
starter

PE90599
HMC 1072
PE90599

Rated Voltage Un (50/60 Hz)


7.2 kV
400 A 63 kA* r.m.s./1s - 50 kA* r.m.s./3s
Rated Current (Ir)
* Intensity short circuit (Isc)

HMC 1072
Rated Voltage Un (50/60 Hz)
7.2 kV
400 A 63 kA* r.m.s./1s - 50 kA* r.m.s./3s
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1968 1983 Ongoing

1992 ECOFIT Ongoing using OEM* designed


adapter, in-house
refurbishment,
on-site maintenance

Offer extension
PE90599

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-32
Medium Voltage Distribution MV CB or Contactor or Disconnector
HMC 1172
To give a new life to your installations
Original brand:
GEC Industrial
Controls, GEC, HMC 1172 (Vacuum) HMC 1172 (Vacuum)
GEC Alstom,
Alstom
Version type:
withdrawable
vacuum motor Main technical characteristics
starter
HMC 1172

PE90600
Rated Voltage Un (50/60 Hz)
7.2 kV
400 A 63 kA* r.m.s./1s - 50 kA* r.m.s./3s
Rated Current (Ir)
* Intensity short circuit (Isc)

HMC 1172
PE90600 Rated Voltage Un (50/60 Hz)
7.2 kV
400 A 63 kA* r.m.s./1s - 50 kA* r.m.s./3s
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1980 2006 Ongoing

2008 ECOFIT Ongoing using cubicles and


trucks still under
manufacture,
refurbishment,
on-site maintenance

Offer extension
PE90601

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-33
Medium Voltage Distribution MV CB or Contactor or Disconnector
HMX 36
To give a new life to your installations
Original brand:
GEC, GEC
Alstom, Alstom HMX 36 (Vacuum) HMX 36 (Vacuum)
Version type:
withdrawable
vacuum
switchgear
Main technical characteristics
HMX 36
PE90602

Rated Voltage Un (50/60 Hz)


36 kV

PE90602
400 A 25 kA* r.m.s./1s - 31.5 kA* r.m.s./3s
Rated Current (Ir)
* Intensity short circuit (Isc)

HMX 36
Rated Voltage Un (50/60 Hz)
36 kV
400 A 25 kA* r.m.s./1s - 31.5 kA* r.m.s./3s
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1980 2003 Ongoing

ECOFIT Ongoing using cubicles and


trucks still under
manufacture,
refurbishment,
on-site maintenance

Offer extension
PE90602

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-34
Medium Voltage Distribution MV CB or Contactor or Disconnector
KIT25-PGDT
To give a new life to your installations
Original brand:
CEM
Version type: CC FP (SF6)
fixed device
compatible
with KIT 25 -
PGDt cubicles

Main technical characteristics

PE90476
CC
Rated Voltage Un (50/60 Hz)
24 kV
400 A 12.5 & 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90477
PE90475 FP
Rated Voltage Un (50/60 Hz)
24 kV
400 A 12.5 & 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1969 1978 1988

1993 ECOFIT Ongoing


FP

Offer extension
PE90487

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-35
Medium Voltage Distribution MV CB or Contactor or Disconnector
KIT 27.2-PGHT
To give a new life to your installations
Original brand:
CEM
Version type: HF4K FP (SF6)
fixed device
compatible
with KIT 27.2 -
PGHt cubicles
Main technical characteristics
HF4K

PE90479
Rated Voltage Un (50/60 Hz)
24 kV
400 A 14.5 & 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90480
PE90478 FP
Rated Voltage Un (50/60 Hz)
24 kV
400 A 14.5 & 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1985 1987 1997

1993 ECOFIT Ongoing


FP

Offer extension
PE90478

PE90437

MiCOM P
series 10 - 20 - 30 - 40
PE90488

Sepam
series 10 - 20 - 40 - 60 - 80

B-36
Medium Voltage Distribution MV CB or Contactor or Disconnector
L
To give a new life to your installations
Original brand:
AEG
Version type: Type D HVX (Vacuum)
withdrawable and E
device
compatible with
L cubicles

Main technical characteristics


PE90557

D, E

PE90558
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV
400 A to 2500 A 20 to 50 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

HVX

PE90559
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV
400 A to 2500 A 20 to 50 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1965 1972 2003

2004 ECOFIT Ongoing


HVX

Offer extension
PE90549

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-37
Medium Voltage Distribution MV CB or Contactor or Disconnector
Metalclad switchgear
To give a new life to your installations
Original brand:
Federal Pioneer
DST 2 & 5 DST 2V (Vacuum)
Version type:
withdrawable
(Air Magnetic Breakers)) DST 5V (Vacuum)
device compatible
with metalclad
switchgear

Main technical characteristics

PE90618
Rated Voltage Un (50/60 Hz)

5 kV 15 kV
3000 A
2000 A DST 2 & 5 (250 - 350 MVA) DST 2 (500 - 750 MVA)
PE90618-2
1200 A
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90619
Rated Voltage Un (50/60 Hz)

5 kV 15 kV
3000 A
2000 A DST 2V (350 MVA) DST 5V (500 - 750 MVA)
1200 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1970 1985 2000 2011

Rack mechanism
1999 ECOFIT added
DST 2V & 5V (Vacuum)

Main characteristics
Magnum circuit breakers correctly interface with Optional capabilities
the existing breaker compartment components
Ŷ,QFUHDVHGIDXOWFXUUHQWLQWHUUXSWLRQUDWLQJ
and maintain safety interlocks inherent in the
Ŷ5HOD\XSJUDGHLPSURYHGDFFXUDF\DQG
original equipment design.
repeatabilityDQGSHUIRUPDQFH
Ŷ1HZFLUFXLWEUHDNHUVDUHLQVWDOOHGLQH[LVWLQJ ŶPower meteringmonitoring and
switchgear. communication.
Ŷ2ULJLQDOIRRWSULQWLVOHIWLQWDFWVDYLQJWLPHDQG Ŷ*URXQGDQGWHVWGHYLFHVDYDLODEOHIRUYDULRXV
PE90619

money. types of switchgear.


Ŷ,QVWDOODWLRQH[SHQVHLVDIUDFWLRQRIQHZ
equipment costs.
Less down time for installation.
Enhanced equipment reliability. Closed Door Electric Racking Mechanism:
Ŷ0DQXIDFWXUHGZLWKQHZFRPSRQHQWV
Ŷ8QGHUJRHVFRPSOHWHIDFWRU\WHVWLQJ
Ŷ%DFNHGE\RXUVWDQGDUGHTXLSPHQWZDUUDQWy. Ŷ1RVWRUDJHVSDFHLVUHTXLUHGIRUWKHHOHFWULFDO
Ŷ1HwHDV\WRPDLQWDLQRSHUDWLQJPHFKDQLVP racking system
PE90619

Ŷ1REXON\DUFFKXWHVWRKDQGOHDQGPDLQWDLQ Ŷ5HTXLUHMXVWDFRPPRQV$&A outlet for


power up.
B-38
Medium Voltage Distribution MV CB or Contactor or Disconnector
Motorstart P12D/P30D
To give a new life to your installations
Original brand:
Merlin Gerin R400 (SF6)
KA, KDA
Version type: R400D (SF6)
withdrawable
device
compatible with
Motorstart P12D/
P30D cubicles
Main technical characteristics
PE90387

KA / KDA

PE90388
Rated Voltage Un (50/60 Hz)
7.2 kV
90 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)

R400 / R400D

PE90389
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1960 1980 1992

1988 ECOFIT Ongoing


R400 / R400D

Offer extension
PE90387

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-39
Medium Voltage Distribution MV CB or Contactor or Disconnector
Motorstart P50D
To give a new life to your installations
Original brand:
Merlin Gerin R400 (SF6)
Version type: C, CD R400D (SF6)
withdrawable CTV1 (Vacuum)
device
compatible with
Motorstart P50D
cubicles

Main technical characteristics


PE90390

C / CD

PE90391
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 200 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)

R400 / R400D

PE90392
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1960 1980 1992

1988 ECOFIT Ongoing


R400 / R400D / CTV1

Offer extension
PE90387

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-40
Medium Voltage Distribution MV CB or Contactor or Disconnector
Motorstart P500D
To give a new life to your installations
Original brand:
Merlin Gerin R400 (SF6)
Version type: C1, CD1 R400D (SF6)
withdrawable CTV1 (Vacuum)
device
compatible with
Motorstart P500D
cubicles
PE90393

Main technical characteristics


C1 / CD1

PE90394
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)

R400 / R400D

PE90395
Rated Voltage Un (50/60 Hz)
7.2 kV
80 A to 250 A 50 kA* with fuses
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1971 1988 1998

1988 ECOFIT Ongoing


R400 / R400D / CTV1

Offer extension
PE90393

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-41
Medium Voltage Distribution MV CB or Contactor or Disconnector
MX51 & MX81
To give a new life to your installations
Original brand:
GEC, GEC Alstom
MX 51 (Vacuum) MX 51 (Vacuum)
Version type:
fixed pattern MX 81 (Vacuum) MX 81 (Vacuum)
vacuum
switchgear

Main technical characteristics


Rated Voltage Un (50/60 Hz)

3.6 kV 17.5 kV
2000 A MX51 (31.5 kA*) MX51 (31.5 kA*)
1250 A MX81 (12.5 kA*) MX81 (12.5 kA*)
MX51 (25 kA*) MX51 (25 kA*)
PE90603 630 A MX81 (20 kA*) MX81 (20 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90603
Rated Voltage Un (50/60 Hz)

3.6 kV 17.5 kV
2000 A MX51 (31.5 kA*) MX51 (31.5 kA*)
1250 A MX81 (12.5 kA*) MX81 (12.5 kA*)
MX51 (25 kA*) MX51 (25 kA*)
630 A MX81 (20 kA*) MX81 (20 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1974 1981 Ongoing

ECOFIT Ongoing refurbishment,


on-site maintenance,
replacement of
vacuum
circuit breakers

Offer extension
PE90437
PE90603

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-42
Medium Voltage Distribution MV CB or Contactor or Disconnector
Normabloc N1347
To give a new life to your installations
Original brand:
Delle Alsthom
Version type:
HVX (Vacuum)
HL
withdrawable FPX (Vacuum)
device
compatible with
NORMABLOC
N1347 cubicles

Main technical characteristics

PE90482
HL
Rated Voltage Un (50/60 Hz)
17.5 kV
630 A to 1250 A 25 & 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90475

PE90483
HVX / FPX
Rated Voltage Un (50/60 Hz)
17.5 kV
630 A to 1250 A 25 & 40 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1975 1981 1991

2009 ECOFIT Ongoing


HVX/FPX

Offer extension
PE90481

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-43
Medium Voltage Distribution MV CB or Contactor or Disconnector
Normasept N743
To give a new life to your installations
Original brand:
Delle Alsthom
Version type: HL FP (SF6)
fixed device
compatible with
NORMASEPT
N743 cubicles

Main technical characteristics


HL

PE90485
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90484

PE90486
FP
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 14.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1971 1981 1991

1990 ECOFIT Ongoing


FP

Offer extension
PE90487

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-44
Medium Voltage Distribution MV CB or Contactor or Disconnector
PA, SC, SD
To give a new life to your installations
Original brand:
Concordia
Sprecher HP T/W/Z HVX (Vacuum)
Version type:
withdrawable
device compatible
with PA, SC and
SD panels
Main technical characteristics
HP 300 - 500

PE90653
Rated Voltage Un (50/60 Hz)
7.2 kV to 12 kV 24 kV
1250 A to 3150 A 12.5 to 40 kA*
800 A to 1250 A 8.4 to 21.7 kA*
Rated Current (Ir)

* Intensity short circuit (Isc)

HVX

PE90652
PE90653

Rated Voltage Un (50/60 Hz)


7.2 kV to 12 kV 20/24 kV
2500 A to 3150 A
16 to 50 kA*
630 A to 2500 A 16 to 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1976 2002 Ongoing

2007 ECOFIT Ongoing


HVX

Offer extension
PE90654

PE90437

MiCOM P
series 10 - 20 - 30 - 40
PE90488

Sepam
series 10 - 20 - 40 - 60 - 80

B-45
Medium Voltage Distribution MV CB or Contactor or Disconnector
R
To give a new life to your installations
Original brand:
AEG
Version type:
E-Breaker
VA/VAA (Vacuum)
withdrawable M-Breaker
device
compatible with
R cubicles
Main technical characteristics
E/M

PE9055
Rated Voltage Un (50/60 Hz)
12 kV 17 - 24 kV 36 kV
4000 A

2500 A 25 to 50 kA*
16 to 31.5 kA*
1250 A

Rated Current (Ir)


* Intensity short circuit (Isc)

PE90554
Rated Voltage Un (50/60 Hz)

PE90556
12 kV 17 kV 24 kV 36 kV
4000 A VA
VA (up to 31.5 kA*)
2500 A (up to 50 kA*) VA VA VA
(up to 40 kA*) (up to 31.5 kA*) (up to 40 kA*)
1250 A VAA VAA
(up to 25 kA*) (up to 25 kA*) VA
VA VA (up to 31.5 kA*)
(up to 50 kA*) (up to 31.5 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1973 1990 2003

1999 ECOFIT Ongoing


VA / VAA

Offer extension
PE90554

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-46
Medium Voltage Distribution MV CB or Contactor or Disconnector
Siclad
To give a new life to your installations
Original brand:
Ansaldo
Version type: MAG II LF2 (SF6)
withdrawable
device
compatible with
Siclad cubicles
Main technical characteristics
PE90580

Rated Voltage Un (50/60 Hz)

PE90581
6 kV 10 kV 15 kV
630 A to 2000 A MAG II - 6 - 250 MAG II - 10 - 500 MAG II - 15 - 350
MAG II - 6 - 400 MAG II - 15 - 300
(20 to 28 kA*)
(20 to 48 kA*) (12 to 30 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

LF2**

PE90582
Rated Voltage Un (50/60 Hz)
6 kV 10 kV 15 kV
2000 A LF2 (40 kA*)
630 A to 1250 A LF1 (31.5 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc) ** For Siclad panel 730 mm & 850 mm wide

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1969 1997

2009 ECOFIT Ongoing


LF2

Offer extension
PE90580

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-47
Medium Voltage Distribution MV CB or Contactor or Disconnector
Solenarc DSE Metal-Clad Switchgear
To give a new life to your installations
Original brand:
Square D
Version type: Type DSE Magnum CB (Vacuum)
Draw-out

Main technical characteristics


Rated Voltage Un (50/60 Hz)

PE90540
5 kV 15 kV
3000 A
2000 A DSE-23B (250 MVA) DSE (250 - 1000 MVA)
1200 A

Rated Current (Ir)


PE90461

Rated Voltage Un (50/60 Hz)

PE90541
5 kV 15 kV
3000 A
2000 A 5MGSB (250 MVA) 15MGSB (250 - 1000 MVA)
1200 A

Rated Current (Ir)

Magnum CB main A true extended life time


characteristics
Built with totally new Commercialisation End of End of End
components and tested to commercialisation spare parts of life
ANSI standards,
Magnum circuit breakers < 1975 1988 2005
correctly interface with
the existing breaker
compartment components 1999 ECOFIT Ongoing
and maintain safety Magnum CB
interlocks inherent
in the original equipment
design.
s New circuit breakers
are installed in existing
switchgear.
s Original footprint is left
intact, saving time and Offer extension
money.
s Installation expense is
a fraction of new
PE90539

equipment costs.
PE90437

- Less down time for


installation.
- Enhanced equipment
reliability.
s Manufactured with new MiCOM P series 10 - 20 - 30 - 40
components.
s Undergoes complete
factory testing.
PE90488

s Backed by our standard


equipment warranty.
s New, easy-to-maintain
operating mechanism.
s No bulky arc chutes
to handle and maintain. Sepam series 10 - 20 - 40 - 60 - 80
s Reduced need for difficult
to obtain spare parts.

B-48
Medium Voltage Distribution MV CB or Contactor or Disconnector
Taillefer T900-T1080
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: DST LF3 (SF6)
withdrawable
device
compatible with
Taillefer
T900 / T1080
cubicles
Main technical characteristics
DST
Rated Voltage Un (50/60 Hz)

PE90408
7.2 kV 17.5 kV
1250 A to 2500 A 50 kA* 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90406

LF3

PE90407
Rated Voltage Un (50/60 Hz)
7.2 kV 17.5 kV
1250 A to 2500 A 50 kA* 31.5 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1965 1974 1986

1989 ECOFIT Ongoing


LF3

Offer extension
PE90406

PE90437

MiCOM P
series 10 - 20 - 30 - 40
PE90488

Sepam
series 10 - 20 - 40 - 60 - 80

B-49
Medium Voltage Distribution MV CB or Contactor or Disconnector
Venus
To give a new life to your installations
Original brand:
Nuova Magrini
GI LF1 (SF6)
Galileo
Version type: GL LF3 (SF6)
withdrawable
device
compatible with Main technical characteristics
Venus cubicles Rated Voltage Un (50/60 Hz)

PE90584
7 kV 12 kV 17 kV 24 kV 36 kV
PE90583

1600 A
to
GL GL GL GL
(50 kA*) (20 to 40 kA*) (25 to 40 kA*) (20 to 31.5 kA*)
3150 A
630 A to GI GI
1250 A (12.5 to 31.5 kA*) (12 to 25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)

PE90585
7 kV 12 kV 17 kV 24 kV 36 kV
3150 A LF3**
1600 A (50 kA*)

630 A to LF1***
1250 A (31.5 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc) ** For Venus panel 900 mm wide *** For Venus panel 600 mm wide

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1989 2000 2015

2008 ECOFIT Ongoing


LF1, LF3

Offer extension
PE90583

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-50
Medium Voltage Distribution MV CB or Contactor or Disconnector
VM6 DM12
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: FB4 SF1 (SF6)
withdrawable
device
compatible with
VM6-DM12
cubicles
Main technical characteristics
FB4

PE90422
PE90415

Rated Voltage Un (50/60 Hz)


7.2 kV 12 kV 17.5 kV 24 kV
400 A to 1250 A 12.5 to 31.5 kA* 12.5 to 25 kA* 12.5 to 20 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

SF1

PE90423
Rated Voltage Un (50/60 Hz)
7.2 kV 12 kV 17.5 kV 24 kV
400 A to 1250 A 12.5 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1975 1993 2009

2010 ECOFIT Ongoing


SF1

Offer extension
PE90400

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-51
Medium Voltage Distribution MV CB or Contactor or Disconnector
VM6 DM22-DM23
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: FB4 SF1 (SF6)
fixed device
compatible with
VM6 DM22/DM23
cubicles

Main technical characteristics


FB4

PE90565
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 20 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90419

PE90566
SF1
Rated Voltage Un (50/60 Hz)
24 kV
400 A to 630 A 12.5 to 20 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1975 1993 2009

2009 ECOFIT Ongoing


SF1

Offer extension
PE90419

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-52
Medium Voltage Distribution MV CB or Contactor or Disconnector
VMX
To give a new life to your installations
Original brand:
GEC, GEC
Alstom, Alstom VMX (Vacuum) VMX (Vacuum)
Version type:
withdrawable
vacuum
switchgear

Main technical characteristics


VMX
PE90692

Rated Voltage Un (50/60 Hz)


11 kV
630 A - 800 A -
Up to 25 kA* for 3s
1250 A - 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

VMX
Rated Voltage Un (50/60 Hz)
11 kV
630 A - 800 A - PE90692
Up to 25 kA* for 3s
1250 A - 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1987 2004 Ongoing

VMX circuit breaker


ECOFIT Ongoing ongoing by Services
2004
can also replace
BV17.
A variant can be
replaced by C variant

Offer extension
PE90692

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-53
Medium Voltage Distribution MV CB or Contactor or Disconnector
WAK
To give a new life to your installations
Original brand:
AEG
Version type: Type D
HVX (Vacuum)
withdrawable and E
device
compatible with
WAK cubicles
Main technical characteristics
PE90546

D&E

PE90547
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV 20 kV 24 kV
2500 A

1600 A 20 to 34 kA*
15 to 30 kA*
400 A

Rated Current (Ir)


* Intensity short circuit (Isc)

HVX

PE90548
Rated Voltage Un (50/60 Hz)
7.2 to 12 kV 20 kV 24 kV
2500 A

1600 A 20 to 34 kA*
15 to 30 kA*
400 A

Rated Current (Ir)


* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1965 1972 2003

2004 ECOFIT Ongoing


HVX

Offer extension
PE90549

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-54
Medium Voltage Distribution MV CB or Contactor or Disconnector
WBA
To give a new life to your installations
Original brand:
AEG VA (Vacuum)
Version type:
withdrawable
VAA (Vacuum) VA (Vacuum)
device compatible ECA (Vacuum) VAA (Vacuum)
with WBA cubicles BAL (Vacuum)
PE90665

Main technical characteristics

PE90657
Rated Voltage Un (50/60 Hz)

12 to 24 kV 12 to 24 kV 12 to 38 kV
1250 A to 2500 A
ECA (20 to 50 kA*) VA (20 to 50 kA*)
630 A to 1250 A VAA (16 to 25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90664
Rated Voltage Un (50/60 Hz)

12 to 24 kV 12 to 38 kV
1600 A to 2500 A
VA (20 to 50 kA*)
630 A to 1600 A VAA (16 to 25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1989 2006 Ongoing

2006 ECOFIT Ongoing


VA/VAA

Offer extension
PE90657

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-55
Medium Voltage Distribution MV CB or Contactor or Disconnector
WBB
To give a new life to your installations
Original brand:
AEG VA (Vacuum)
Version type: VA (Vacuum)
VAA (Vacuum)
withdrawable VAA (Vacuum)
device compatible ECA (Vacuum)
with WBB cubicles

Main technical characteristics


Rated Voltage Un (50/60 Hz)

PE90663
12 to 24 kV 12 to 24 kV 12 to 38 kV
1250 A to 2500 A
ECA (20 to 50 kA*) VA (20 to 50 kA*)
630 A to 1250 A VAA (16 to 25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90663

PE90664
Rated Voltage Un (50/60 Hz)

12 to 24 kV 12 to 38 kV
1200 A to 2500 A
VA (20 to 50 kA*)
630 A to 1200 A VAA (16 to 30 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1989 2006 Ongoing

2006 ECOFIT Ongoing


VA/VAA

Offer extension
PE90660

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-56
Medium Voltage Distribution MV CB or Contactor or Disconnector
WKC
To give a new life to your installations
Original brand:
AEG VA (Vacuum)
Version type: FPX (SF6)
VAA (Vacuum)
withdrawable VA (Vacuum)
device compatible MC (Vacuum)
VAA (Vacuum)
with WKC cubicles BAL (Vacuum)

Main technical characteristics


Rated Voltage Un (50/60 Hz)

PE90661
12 to 24 kV 12 to 38 kV
1250 A to 2500 A
VA (20 to 50 kA*)
630 A to 1250 A VAA (16 to 25 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90661

Rated Voltage Un (50/60 Hz)

PE90650
3.6 to 7.2 kV 7.2 to 24 kV 12 to 24 kV 12 to 38 kV
2500 A to 4000 A
FPX (31.5
1600 A to 2500 A to 40 kA*)

1250 A to 1600 A VA
630 A to 1250 A VAA (20 to 50 kA*)
(16 to 25 kA*)
400 A Contactor
Vacuum
(16 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1987 2003 Ongoing

2004 ECOFIT Ongoing


FPX
VA/VAA

Offer extension
PE90662

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-57
Medium Voltage Distribution MV CB or Contactor or Disconnector
YSF6
To give a new life to your installations
Original
brand: Yorkshire
YSF6 (SF6) YSF6 Evolis (Vacuum)
Switchgear /
Merlin Gerin
Version type:
withdrawable
device compatible
with YSF6 cubicle

Main technical characteristics


PE90607

PE90608
YSF6
Rated Voltage Un (50/60 Hz)
12 kV
630 A to 1250 A Up to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

YSF6 Evolis

PE90609
Rated Voltage Un (50/60 Hz)
12 kV
630 A to 1250 A Up to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1981 2001

2004 ECOFIT Ongoing YSF6


YSF6 Evolis

Offer extension
PE90419

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-58
B-59
Medium Voltage Distribution MV Panel
D-12
To give a new life to your installations
Original brand:
AEG
Version type: D-12 D-12
Air Insulated
Switchgear
PE90648

Main technical characteristics


D-12
Rated Voltage Un (50/60 Hz)
12 kV
1600 A 25 to 31.5 kA*
200 A to 1250 A 10 to 20 kA* - 20 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

D-12
Rated Voltage Un (50/60 Hz)
12 kV
1600 A 25 to 31.5 kA*
630 A to 1250 A 20 to 25 kA*
Rated Current (Ir) PE90648

* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1994 2004

2004 ECOFIT Ongoing Complete D-12


panels by Services

Offer extension
PE90648

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-60
Medium Voltage Distribution MV Panel
D-24
To give a new life to your installations
Original brand:
AEG
Version type: D-24 D-24
Air Insulated
Switchgear

Main technical characteristics


D-24
Rated Voltage Un (50/60 Hz)
24 kV
630 A to 2150 A 16 to 25 kA*
100 A to 630 A 10 to 16 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90649 D-24
Rated Voltage Un (50/60 Hz)
24 kV
630 A to 1250 A 10 to 25 kA*
Rated Current (Ir) PE90651

* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1994 2004

2004 ECOFIT Ongoing Complete D-24


panels by Services

Offer extension
PE90649

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-61
Medium Voltage Distribution MV Panel
F100/200
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: F100/200 F100/200
Air Insulated
Switchgear

Main technical characteristics


Rated Voltage Un (50/60 Hz)

7.2 kV 12 kV 17.5 kV
630 A to 3150 A F100 F200
(25 to 50 kA*) (25 to 50 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)
PE90645

F100/200
Incomer / Feeder / Coupling (arc proof in option)
Rated Voltage Un (50/60 Hz)
7.2 kV 12 kV 17.5 kV
630 A to 3150 A 25 to 50 kA*
PE90644
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1980 1998 Ongoing

1998 ECOFIT Ongoing Complete F100/200


panels by Services

Offer extension
PE90645

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-62
Medium Voltage Distribution MV Panel
F100C
To give a new life to your installations
Original brand:
Merlin Gerin
Version type: F100C F100C
Air Insulated
Switchgear
PE90645

Main technical characteristics


F100C
Rated Voltage Un (50/60 Hz)
7.2 kV
630 A to 2500 A 8 to 50 kA* (with fuses)
Rated Current (Ir)
* Intensity short circuit (Isc)

F100C
Rated Voltage Un (50/60 Hz)
7.2 kV
630 A to 2500 A 8 to 50 kA* (with fuses)
PE90644
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1980 1998 Ongoing

1998 ECOFIT Ongoing Complete F100C


panels by Services

Offer extension
PE90645

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-63
Medium Voltage Distribution MV Panel
PX12-24
To give a new life to your installations
Original brand:
Alstom
Version type: PX 12-24 PX 12-24
Air Insulated
Switchgear

Main technical characteristics


PE90677

Rated Voltage Un (50/60 Hz)

12 kV 24 kV
2500 A to 3150 A
PX 12 (25 to 40 kA*)
400 A to 2500 A PX 24 (16 - 25 - 31.5 kA*)
Rated Current (Ir)
* Intensity short circuit (Isc)

Rated Voltage Un (50/60 Hz)

12 kV 24 kV
2500 A to 3150 A
PX 12 (25 to 40 kA*)
400 A to 2500 A PX 24 (16 - 25 - 31.5 kA*)
PE90677
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1993 1997 Ongoing

1997 ECOFIT Ongoing Complete PX panels


by Services

Offer extension
PE90677

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-64
Medium Voltage Distribution MV Panel
R
To give a new life to your installations
Original brand:
AEG
Version type: R R
Air Insulated
Switchgear
PE90655

Main technical characteristics


R
Rated Voltage Un (50/60 Hz)
12 kV 24 kV
400 A to 2500 A 31.5 to 40 kA* 16 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

R
Rated Voltage Un (50/60 Hz)
12 kV 24 kV
400 A to 2500 A 20 to 40 kA* 16 to 25 kA*
PE90655
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1973 1990 Ongoing

1990 ECOFIT Ongoing Complete R panels


by Services

Offer extension
PE90655

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-65
Medium Voltage Distribution MV Panel
VMX
To give a new life to your installations
Original brand:
GEC, GEC
Alstom, Alstom VMX (Vacuum) VMX (Vacuum)
Version type:
Air Insulated
Switchgear.
Withdrawable
vacuum
switchgear Main technical characteristics
VMX
PE90692

Rated Voltage Un (50/60 Hz)


11 kV
630 A - 800 A -
Up to 25 kA* for 3s
1250 A - 2000 A
Rated Current (Ir)
* Intensity short circuit (Isc)

VMX
Rated Voltage Un (50/60 Hz)
11 kV
630 A - 800 A -
Up to 25 kA* for 3s
1250 A - 2000 A
PE90692
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1987 2004 Ongoing

2004 ECOFIT Ongoing Complete VMX panels


ongoing by Services
or BV17 extension

Offer extension
PE90692

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-66
Medium Voltage Distribution MV Panel
WBA
To give a new life to your installations
Original brand:
AEG
Version type: WBA WBA
Air Insulated
Switchgear

Main technical characteristics


WBA
Rated Voltage Un (50/60 Hz)
12 to 24 kV 12 to 38 kV
1250 A to 2500 A 20 to 50 kA*
20 to 50 kA*
630 A to 1250 A 16 to 25 kA* & 20 to 50 kA*
Rated Current (Ir)

PE90657
PE90657 * Intensity short circuit (Isc)

WBA
Rated Voltage Un (50/60 Hz)
12 to 24 kV 12 to 38 kV
1600 A to 2500 A
20 to 50 kA*
630 A to 1600 A 16 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1989 2006 Ongoing

2006 ECOFIT Ongoing Complete WBA panels


by Services

Offer extension
PE90657

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-67
Medium Voltage Distribution MV Panel
WBB
To give a new life to your installations
Original brand:
AEG
Version type: WBB WBB
Air Insulated
Switchgear
PE90660

Main technical characteristics


WBB
Rated Voltage Un (50/60 Hz)

PE90659
12 to 24 kV 12 to 38 kV
1250 A to 2500 A 20 to 50 kA*
20 to 50 kA*
630 A to 1250 A 16 to 25 kA* & 20 to 50 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

WBB
Rated Voltage Un (50/60 Hz)
12 to 24 kV 12 to 38 kV
1200 A to 2500 A
20 to 50 kA*
630 A to 1200 A 16 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1989 2006 Ongoing

2006 ECOFIT Ongoing Complete WBB panels


by Services

Offer extension
PE90660

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-68
Medium Voltage Distribution MV Panel
WKC
To give a new life to your installations
Original brand:
AEG
Version type: WKC WKC
Air Insulated
Switchgear

Main technical characteristics


WKC
Rated Voltage Un (50/60 Hz)

12 to 24 kV 12 to 38 kV
1250 A to 2500 A
20 to 50 kA*
630 A to 1250 A 16 to 25 kA*
Rated Current (Ir)
* Intensity short circuit (Isc)

PE90661 WKC
Rated Voltage Un (50/60 Hz)

3.6 to 7.2 kV 7.2 to 24 kV 12 to 24 kV 12 to 38 kV


2500 A to 4000 A
31.5 to 40 kA*
1600 A to 2500 A
1250 A to 1600 A 20 to 50 kA*
630 A to 1250 A 16 to 25 kA*
400 A 16 kA*
PE90661
Rated Current (Ir)
* Intensity short circuit (Isc)

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1987 2003 Ongoing

2003 ECOFIT Ongoing Complete WKC panels


by Services

Offer extension
PE90662

PE90437

MiCOM P series 10 - 20 - 30 - 40
PE90488

Sepam series 10 - 20 - 40 - 60 - 80

B-69
PE90457

TM

ECOFIT

Protection
relays
ECOFITTM Protection relays

Generic offer
All C-2

Specific offer
KCGG 122&142 C-3
SEPAM 2000 C-4
VIP11R & VIP12R C-5
Protection upgrade benefits C-6

C-1
Protection relays Generic offer
All
To give a new life to your installations
Original brand:
all brands MiCOM
Version type: Old types
Sepam
protection relays
compatible
with all MV
switchboard

PE90437
PE90487

MiCOM P series 10 - 20 - 30 - 40

PE90488

Sepam series 10 - 20 - 40 - 60 - 80

Intelligent Electronic Device (IED) by Schneider Electric


MiCOM Sepam
฀ ฀
฀Transport ฀Mining, Minerals & Metal
฀ ฀ ฀ ฀
Series 10 ‡6LPSOHDSSOLFDWLRQV8RU, Series 20

PE90449
PE90438

Series 20 ‡8VXDODSSOLFDWLRQV Series 40


PE90449
PE90366

‡'LUHFWLRQDOSURWHFWLRQ

Series 30 ‡'HPDQGLQJDSSOLFDWLRQV Series 60


PE90437

PE90488

‡&ODVVLFDXWRPDWLRQ*RRVH0HVVDJHV

Series 40 ‡&XVWRPDSSOLFDWLRQV Series 80


PE90449
PE90436

‡'LfIHUHQWLDOGLVWDQFHFRPSOH[DXWRPDWLRQ

C-2
Protection relays Specific offer
KCGG122 & 142
To give a new life to your installations
Original brand:
Alstom
Version type:
KCGG 122 & 142 MiCOM P123R
draw-out
PE90634

Main technical characteristics

K range relay - KCGG 122 & 142

PE90634
Case
Installation Withdrawable case
Language English
Communication KBus / Courier
Power supply 24 V / 125 VDC - 48 V / 250 VDC
Digital input supply 48 VDC only

PE90635
MiCOM P123R

Case
Installation Withdrawable case
Language Multilanguage
Communication KBus / Courier, DNP3, IEC60870-5-103
Power supply 24 V / 250 VDC - 48 V / 240 VDC
Digital input supply According to Power Supply (above)

A true extended life time


Commercialisation End of commercialisation End of support by Schneider Electric
by Schneider Electric,
under AREVA brand *
1997 2010 2012

2011 ECOFIT
Ongoing

* Since 2010 commercialisation under Alstom Grid brand

C-3
Protection relays Specific offer
Sepam 2000
To give a new life to your installations
Original brand:
Merlin Gerin
Version type:
Sepam 2000 Sepam serie 60/80
Sepam 2000
series
PE90638

Main technical characteristics

PE90638

PE90639
Sepam Sepam
Sepam 2000
serie 80 serie 60
Motor application M06, M07, M08, M14 
M02 to M05, M09, M11, M15, M16,

M20 to M23
Substation S02, S03, S06 to S09 
application
S01, S04, S05 
Busbar application B02, B04, B07, B12 
B01, B03 
Transformer T01 to T03, T06, T07, T09, T10, T12 to T15,

application T17 to T19
without temp.
measurement T04, T05, T11, T16 

Transformer T21, T22, T23, T26, T27, T29, T30,



application T32 to T35, T37 to T39
with temp.
measurement T24, T25, T31, T36 

Generator
G01 to G08, G12, G13, G15 to G18 
application
Capacitor bank C02, C04, C06, C08 
application
C01, C03 
Transformer
D02, D22 
diff. application

A true extended life time


Commercialisation End of End of End
commercialisation spare parts of life

1993 2006 2015

2012 ECOFIT Ongoing


Sepam serie 60, 80

C-4
Protection relays Specific offer
VIP11R-12R for RM6+
To give a new life to your installations
Original brand:
Merlin Gerin VIP11R
Version type: ECOFITTM VIP11-12R
VIP11R or VIP12R
VIP12R
protection relays
compatible for
RM6 +

RM6 + commercialized between 1987 and 1998


PE90567

VIP11R

PE90568
or VIP12R
PE90570

PE90569

PE90569

ECOFIT™
VIP11-12R

C-5
Protection relays Protection upgrade benefits

Improve the performance of your system Why protection upgrade?


with the latest technology in micro-processor
By replacing solid state and older type electromechanical protection relays
based integrated relays.
with technologically advanced multi-function microprocessor-based digital relays,
the performance accuracy and longevity of your system can be si
With a number of different protection functions Schneider Electric's range of relays
can provide a range of options to include metering; communication; event capture;
monitoring and control. Units are self-diagnostic to provide enhanced reliability.
It is normally possible to use the existing current and potential transformers
and auxiliary digital relay inputs.
Schneider Electric's application based approach makes it easy to select
the appropriate relay for your needs.

What are the benefits?


Accuracy System protection at the current level reduces unnecessary outages
and minimise stresses to equipment.

Increased accuracy of measurement assists in cost allocation


and understanding power demand requirements.

High reliability from advanced self supervision systems.

Flexibility The integrated functions of the relay allow for communications and control
of the equipment either as a stand-alone unit or as part of networked systems.

All components in the protection chain are referenced and interface rapidly.

No constraints for integration in cubicles due to the compact size of the base unit.

Ease of use Settings and adjustments are entered via the device's keypad
and visually displayed.

Reduced costs The amalgamation of functions into one self-diagnosing meter


reduces expenditure and saves on space.

C-6
Medium & Low Voltage Distribution
Modernisation of switchboards
TM

ECOFIT
Green is our colour
Catalogue 2013

Schneider Electric nv/sa Dieweg 3 Due to evolution of standards and equipment, the characteristics indicated in
B-1180 Bruxelles/Brussel text and images of this document do not constitute a commitment on our part
Tel.: (02) 373 75 01 without conformation.
be-aftersales.be@schneider-electric.com
www.schneider-electric.be

TVA/BTW: BE 0451.362.180
 Printed on recycled paper

RPM Bruxelles/RPR Brussel


ING: 310-1110264-88
IBAN: BE 56 3101 1102 6488
32VP297EN SWIFT BIC: BBRU BE BB Realisation & printing: DeckersSnoeck 03/13

Вам также может понравиться