Referring to item 33 of our latest MOM dated 13&14/03/2010 with BCA, please find the following the following items for you clarification for
B/P and Hyper Compressors.
Most of the following comments have been already raised and agreed during previous technical clarification meetings, however not properly
incorporated in your final proposal. Hence they are repeated here to be reconfirmed/clarified by BCA.
Sheet 1 of 4
PROJECT: KORDESTAN 300 KTA LDPE PLANT
INQUIRY REFERENCE: ME-MRQ-001 (BOOSTER / PRIMARY)
ME-MRQ-002 (HYPER)
VENDOR: BURCKHARDT COMPRESSION AG (BCA)
PROPOSAL REFERENCE: 2010.151 - DATE: 11.02.2010 (HYPER)
2010.152 – DATE: 1.02.2010 (BOOSTER / PRIMARY)
ATTACHMENT: NONE
As agreed in item 57 of MoM dated Confirmed, except for 1st stage where the water design pressure (shell side) is
27/01/2009, protection of gas coolers should
7. be accomplished by means of 2 rupture discs higher than required process gas design pressure (tube side), thus rupture disc
on the shell of each gas cooler concerned. does not bring anything for this position.
B HYPER COMPRESSOR:
1. Referring to clause 2.4 of proposal, Correct values for PSHH, Rupture Discs (Safety Relief Pressure) and the Main
compressor/cylinder main data, for both stages
setting of PSHH and rupture disk are exactly Motor rating will be provided in the official issue of the document ‘Operating Range’.
Sheet 2 of 4
PROJECT: KORDESTAN 300 KTA LDPE PLANT
INQUIRY REFERENCE: ME-MRQ-001 (BOOSTER / PRIMARY)
ME-MRQ-002 (HYPER)
VENDOR: BURCKHARDT COMPRESSION AG (BCA)
PROPOSAL REFERENCE: 2010.151 - DATE: 11.02.2010 (HYPER)
2010.152 – DATE: 1.02.2010 (BOOSTER / PRIMARY)
ATTACHMENT: NONE
Sheet 3 of 4
PROJECT: KORDESTAN 300 KTA LDPE PLANT
INQUIRY REFERENCE: ME-MRQ-001 (BOOSTER / PRIMARY)
ME-MRQ-002 (HYPER)
VENDOR: BURCKHARDT COMPRESSION AG (BCA)
PROPOSAL REFERENCE: 2010.151 - DATE: 11.02.2010 (HYPER)
2010.152 – DATE: 1.02.2010 (BOOSTER / PRIMARY)
ATTACHMENT: NONE
Sheet 4 of 4