(MACHINE-ROOM-LESS SYSTEM)
Series-IP Version2
Speed
1.75m/sec
Capacity
Travel
2500kg 80m
30floors
Making Positive Contributions to the Earth and
its People through Technology and Action
Design
Basic Specifications
Milestones of Energy-Saving Technologies Our elevators stay a step ahead with even more advanced energy conservation technology:
in Elevator Development Introducing the Regenerative Converter (Optional)
Compared to the same type of elevator without a Regenerative Converter:
Energy-saving effect: Up to 35%
CO2 emissions: -1,400 kg/year
(The elevator is operated under different conditions from those in the table, “Milestones
of Energy-Saving Technologies in Elevator Development” on page 1.)
The Regenerative Converter is applicable to the elevators with the rated capacity of 630kg to 1600kg.
Please refer to page 5 for details.
Approx.
Notes:
*1: Alternative Current, Variable Voltage
*2: Variable Voltage, Variable Frequency
–70%
*3: CO2 emissions in this table are from elevator
operation and do not include emissions from Approx.
manufacturing, transportation and other processes.
–3770
kg/year
1 2
Our Global Standards for Machine-Room-Less Elevators
Machine-Room-Less
630 825 1050 1275 1600 2000 2500 (kg) As all equipment is installed within the hoistway, there are
far fewer restrictions on building design.
The rated capacity has been extended from 1600kg to 2500kg
for the ELENESSA Series-IP Version2. Group Control
Advanced group control systems enhance transport
efficiency and reduce passenger waiting time through
optimum car allocation.
Pleasant Design
Increased design options make elevators more pleasant and
easier to use.
3 4
Green Technology
Profile
SUSTAINABLE ENERGY USE
Mitsubishi Electric’s leading-edge technologies have made it possible for elevators to conserve energy.
Our Regenerative Converter makes the most of power generated by the traction machine. Additionally, thanks
to the Joint-Lapped Motor and energy-saving features, the elevators use energy more wisely and efficiently.
Note: *The Regenerative Converter is applicable to the elevators with the rated capacity of 630kg to 1600kg.
5 6
Variable Traveling Speed Elevator System
Profile
TIME-SAVING
With Mitsubishi Electric’s industry-first Variable Traveling Speed Elevator System, an elevator can
travel faster than its rated speed according to the number of passengers, ultimately reducing waiting
and traveling time.
The Variable Traveling Speed Elevator System allows elevators make the elevator travel at the rated speed. 1.6
to travel faster than their rated speed depending on the Thus, by utilizing the unused power of the traction machine, 1.6m/sec
1.5
number of passengers in the car (rapid mode). When the the elevator can travel faster. Its efficient transport reduces
weight is well-balanced between the car and the counter- frustratingly long waiting and traveling time. VSE is a solution
1.25
weight, the traction machine does not need its full power to for users seeking time-savings in elevator travel.
1.0
1.0m/sec (Rated speed) 1.0m/sec (Rated speed)
[ 1-2
persons ] [2-5 persons]
[ 5-6
persons ] [6-9 persons]
[ 9-10
persons ] [10-12 persons] [12-14 persons]
[Number of passengers in the car when the maximum number of passengers is 14.]
Note: *The Variable Traveling Speed Elevator System is applicable to the elevators with a rated speed of 1.0m/sec and the rated capacity of 630kg to 1600kg.
7 8
Machine-Room-Less
Profile
SPACE-SAVING
As all equipment is installed within the hoistway, there are fewer restrictions on building design
except for the actual space required for the shaft. Architects and interior designers have more design
freedom.
9 10
Group Control
Profile
EFFICIENT TRANSPORTATION
Mitsubishi Electric’s breakthrough AI Neural Network* technology in elevator control enhances transport
efficiency and reduces passenger waiting time through optimum car allocation, which allows elevators to
use energy effectively. Two basic group control systems offer a variety of innovative group control features.
Note: *Neural Network is a mathematical model that emulates the structure of the nerves and cells of the human brain and its information processing mechanism.
25 8
20
6 Destination Oriented Prediction System (DOAS-S) (Optional)
15
4
10
5
2 Allocates passengers to cars depending on destination floors
AI-2100N AI-2200C
0 0 When a passenger enters a destination floor at a hall, the hall operating panel immediately indicates which car will serve the floor.
Morning up Daytime Lunchtime Evening Morning up Daytime Lunchtime Evening
peak down peak peak down peak Because the destination floor is already registered, the passenger does not need to press a button in the car. Furthermore,
Ele. No. Ele. No. dispersing passengers by destination prevents congestion in cars and minimizes their waiting and traveling time.
11 12
Pleasant Design
Profile
PASSENGER-FRIENDLY
Mitsubishi Electric designs elevators with not only safety and a comfortable ride, but also
passenger-friendliness in mind. Its design makes elevators more pleasant and easier to use.
A sophisticated car design that suits various uses Easy-to-use design elements such as large indicators, tactile Large glass windows increase visibility at the hall area, which
creates a pleasant and comfortable impression. buttons, handrails and mirrors make elevators even more can enhance security.
passenger-friendly.
LCD Position Indicator (Universal Design: Copyright 1997 N.C. State University,
Various graphic indication patterns increase The Center for Universal Design.)
visibility.
<Indication examples>
Normal
operation
Rapid mode
in Variable Traveling
Speed Elevator
System
Emergency
operation
Swing-type Car Operating Higher Ceiling
Panel A higher ceiling provides a
Incorporated in the front spacious atmosphere in the car.
Tactile Button return panel, the car operating The ceiling can be as high as
Popular stainless steel matte buttons panel adds stylish accents. 2700mm depending on the
are available. ceiling type. Items introduced on this page may be available as options.
13 14
Car Design
S00 Standard Ceiling N10 N20 N90 Painted Steel Sheet
Milky white globe (Plastic cover made of resin)
Downlights Central indirect downlights Indirect full lighting
( Only S00, N10, N20,
N40, N90 and N110 )
Y031
Y055
Y074
Design
Standard Design Image Car Finishes Walls Standard Stainless steel hairline Entrance
columns
Standard CO doors: Integrated with front return panel
Optional Pattern-printed steel sheet 2S doors: Stainless steel hairline
Ceiling - Color Y033 (Ceiling height: 2200mm*) Painted steel sheet Optional Stainless steel mirror
Walls - SUS-HL Transom Standard Stainless steel hairline Kickplate Standard Aluminum
panel Optional Pattern-printed steel sheet Optional Painted steel sheet
Transom panel - SUS-HL Painted steel sheet Stainless steel hairline
Doors - SUS-HL Stainless steel mirror Flooring Standard Durable vinyl tile (2mm thick)
Front return panels - SUS-HL Doors Standard Stainless steel hairline Optional Durable rubber tile (3mm or 6mm thick)
Optional Pattern-printed steel sheet Carpet (Supplied by customer)
Kickplate - Aluminum Painted steel sheet Marble/granite (Supplied by customer)
Flooring - PR18 Stainless steel mirror Sill Standard Extruded hard aluminum
Car operating panel - CBE-N211 Glass windows Optional Stainless steel
See-through doors
Note: *The higher ceiling type is available up to 2700mm as an option. Front return Standard Stainless steel hairline This table may not be applicable to the elevators with the rated capacity
panel Optional Stainless steel mirror of over 1600kg; please consult our local agents.
Flooring
Durable vinyl tiles (Standard)
Walls, Doors, Transom Panel and Front Return Panel
Stainless Steel Hairline (Standard) Pattern-Printed Steel Sheet (Optional)
PR45 Not applicable to front return panel
PR13
Painted Steel Sheet (Optional)
Not applicable to front return panel
PR86
PR40 Y016 Y017 Y033 Y051 Y054 Y055 Y071 Y116 CP101 CP111 CP141
N10S
Ceiling - SUS-HL
Walls - Pattern CP141
Transom panel - Pattern CP141
Doors - Pattern CP141
Design
Front return panels - SUS-HL
N10W N30
Lighting - Downlights Lighting - Indirect full lighting
Ceiling - Color Y033 Ceiling - Arched milky white resin
Walls - Pattern CP101 board
Transom panel - Pattern CP101 Ceiling trim - Black alumite
Doors - Pattern CP101 Walls - Pattern CP111
Front return panels - SUS-HL Transom panel - Pattern CP111
Kickplate - SUS-HL Doors - Pattern CP111
Flooring - PR18 Front return panels - SUS-HL
Car operating panel - CBE-N211 Kickplate - SUS-HL
Flooring - PR18
Car operating panel - CBE-N221
Note: Please refer to page 17 and 18 for specifications of car finishes. Actual elevator color may differ slightly from those shown.
17 18
Design Images
N40 N100
Lighting - Half mirror and downlights Lighting - Indirect full lighting
Ceiling (both sides) - Color Y055 Ceiling - Arched milky white resin board
Ceiling trim - Black alumite Ceiling trim - Black alumite
Walls - Pattern CP53 Walls - Pattern CP23
Transom panel - Pattern CP53 Transom panel - Pattern CP23
Doors - Pattern CP53 Doors - Pattern CP23
Front return panels - SUS-HL Front return panels - SUS-HL
Kickplate - SUS-HL Kickplate - Color Y055
Flooring - PR86 Flooring - PR40
Car operating panel - CBE-N221 Car operating panel - CBE-C251
Design
N90 N110
Lighting - Indirect full lighting Lighting - Indirect full lighting
Ceiling - Acrylic blocks and milky white Ceiling - Color Y055
resin board Ceiling trim - Black alumite
Ceiling trim - Black alumite Walls - Pattern CP101
Walls - Pattern CP141 Transom panel - Pattern CP101
Transom panel - Pattern CP141 Doors - Pattern CP101
Doors - Pattern CP141 Front return panels - SUS-HL
Front return panels - SUS-HL Kickplate - Color Y055
Kickplate - SUS-HL Flooring - PR13
Flooring - PR45 Car operating panel - CBE-C240
Car operating panel - CBV-N211
Note: Please refer to page 17 and 18 for specifications of car finishes. Actual elevator color may differ slightly from those shown.
19 20
Observation Car (NY-30)
Natural light gives the car a spacious atmosphere.
Glass can be arranged in various positions and there are different ceiling types to choose from (S10, N10 to N40 and N90
to N110) to suit to the elevator usage.
Design
Design Image
Ceiling type - N10 Doors - SUS-HL with glass window
Lighting - Downlights Front return panel - SUS-HL
Walls (inside) - SUS-HL Kickplate - SUS-HL
Walls (outside) - Painted finish (N5.5: Gray) Flooring - PR62
Windows - Transparent flat glass Handrail - SUS-HL (YH-55S: Cylindrical type)
Glass frame - Aluminum Car operating panel - CBE-N211
Transom panel - SUS-HL
Glass Arrangement
Design
E-102 E-302 E-312
Jamb - Color Y051 Jamb - Color Y116 Jamb - SUS-HL Jamb - SUS-HL
Doors - Color Y051 Doors - Color Y116 Transom panel - SUS-HL Transom panel - SUS-HL
Hall position indicator Hall button - HBE-C260N Boxless * Doors - Stainless steel etching (EP-B-009) Doors - See-through doors
and call button - PIE-A210N Boxless * Hall position indicator - PIH-D421 Boxless * Hall position indicator - PID-D410 Hall position indicator - PID-D410
Hall button - HBE-C210N Hall button - HBE-C210N
Note: *Please refer to page 30 for the sectional image of the boxless type.
Entrance Finishes
Jambs, Doors and Transom Panel Etching Textures Metallic surface
Not applicable to front return panel Finished surface of etching Jamb Standard Painted steel sheet
Painted Steel Sheet (Standard) Optional Stainless steel hairline
Doors Standard Painted steel sheet
Optional Stainless steel hairline
Stainless steel etching
Stainless steel mirror
Glass windows
See-through doors
Y002 Y003 Y004 Y006 Y008 Y009 Y010 Y014 EP-A-004 EP-A-011 EP-A-021
Transom Optional Painted steel sheet
panel Stainless steel hairline
Stainless steel etching
Sill Standard Extruded hard aluminum
Optional Stainless steel
Y016 Y017 Y033 Y051 Y054 Y055 Y071 Y116 This table may not be applicable to the elevators with the capacity
EP-B-009 EP-D-006 EP-F-004 of over 1600kg; please consult our local agents.
Design
CBE-N211 CBE-N217 CBE-N218 CBV-N211 CBJ-N211 CBE-N221
(Standard for 2 to 30 floors) (With alarm indication for EN81-70) *2 (With alarm indication for EN81-70) *2 (LCD indicator)
Tactile button *1 Tactile button Tactile button Tactile button *3 Flat button *3 Tactile button *1
(Plastic) (Plastic) (Plastic) (Stainless steel matte) (Plastic) (Plastic)
Notes:
*1: Flat floor buttons are also available as CBF-N211 / CBF-N221.
*2: Interphone which complies with EN81-72 is required.
*3: Please note that flat (non-tactile) buttons and buttons without color contrast cannot be used in
countries where regulations such as EN81-70 mandate specific measures for physically disabled passengers. Actual elevator color may differ slightly from those shown.
25 26
Car Operating Panels
Front Return Panel
Design
CBE-C240 CBV-C240 CBJ-C240 CBE-C251 CBE-D221
(LCD indicator) (Swing type)
Tactile button *1 Tactile button *2 Flat button *2 Tactile button *1 Tactile button *1
(Plastic) (Stainless steel matte) (Plastic) (Plastic) (Plastic)
Notes:
*1: Flat floor buttons are also available as CBF-C240 / CBF-C251 / CBF-D221.
*2: Please note that flat (non-tactile) buttons and buttons without color contrast cannot be used in
countries where regulations such as EN81-70 mandate specific measures for physically disabled passengers. Actual elevator color may differ slightly from those shown.
27 28
Hall Signal Fixtures
Hall Position Indicators and Call Buttons Hall Buttons
Design
HBE-A210N Boxless HBE-C210N HBE-C260N Boxless HBV-C210N HBJ-C210N
HBE-A210B Tactile button *1 Tactile button *1 Tactile button *2 Flat button *2
PIE-A210N Boxless PIE-A220N Boxless PIE-C210N PIE-C220N Tactile button *1 (Plastic) (Plastic) (Stainless steel matte) (Plastic)
(Standard) (Standard) Tactile button *1 Tactile button *1 (Plastic)
(Plastic) (Plastic)
PIE-A210B PIE-A220B
Tactile button *1
(Plastic)
Tactile button *1
(Plastic) Hall Position Indicators Hall Lanterns
PIH-D410
HLH-A10
PIH-D421 Boxless
HLV-A10
PID-D410
(Built into transom panel)
PIV-C210N PIV-C220N PIJ-C210N PIJ-C220N of Boxless Type Actual dimensions and positions of the faceplate,
Tactile button *2 Tactile button *2 Flat button *2 Flat button *2 the box and the wiring hole may differ depending
(Stainless steel matte) (Stainless steel matte) (Plastic) (Plastic) on the type.
Wiring hole
HBE-A210 and HBE-C260 are not applicable to the top floor.
Please consult our local agents for details.
Notes:
*1: Flat floor buttons are also available as PIF-A210 / PIF-A220 / PIF-C210 / PIF-C220 / HBF-A210 / HBF-C210 / HBF-C260.
*2: Please note that flat (non-tactile) buttons and buttons without color contrast cannot be used in
countries where regulations such as EN81-70 mandate specific measures for physically disabled passengers. Actual elevator color may differ slightly from those shown.
29 30
Features
Feature Description 1C- 2C- 3C to 4C 3C to 8C Feature Description 1C- 2C- 3C to 4C 3C to 8C
2BC 2BC ΣAI-22 ΣAI-2200C 2BC 2BC ΣAI-22 ΣAI-2200C
■ OPERATIONAL AND SERVICE FEATURES ■ GROUP CONTROL FEATURES
Safe Landing (SFL) If a car has stopped between floors due to some equipment malfunction, Expert System and Fuzzy Logic Artificial expert knowledge, which has been programmed using “expert
the controller checks the cause, and if it is considered safe to move the car, system” and “fuzzy logic”, is applied to select the ideal operational rule
the car will move to the nearest floor at a low speed and the doors will which maximizes the efficiency of group control operations.
open. Psychological Waiting Time Cars are allocated according to the predicted psychological waiting time
Next Landing (NXL) If the elevator doors do not open fully at a destination floor, the doors Evaluation for each hall call. The rules evaluating psychological waiting time are
close, and the car automatically moves to the next or nearest floor where automatically changed in a timely manner in response to actual service
the doors will open. conditions.
Cooperative Optimization The system predicts a potential hall call, which could cause longer waiting
Continuity of Service (COS) A car which is experiencing trouble is automatically withdrawn from group Assignment time. Car assignment is performed considering not only current and new
control operation to maintain overall group performance. calls but also near-future calls. Please refer to page 11.
Automatic Bypass (ABP) A fully-loaded car bypasses hall calls in order to maintain maximum Car Travel Time Evaluation Cars are allocated to hall calls by considering the number of car calls that will
operational efficiency. reduce passenger waiting time in each hall and the travel time of each car.
Distinction of Traffic Flow with Traffic flows in a building are constantly monitored using neural network
Overload Holding Stop (OLH) A buzzer sounds to alert the passengers that the car is overloaded. The Neural Networks (NN) technology, and the optimum operational pattern, such as Lunchtime
doors remain open and the car will not leave that floor until enough Service or Up Peak Service, is selected or canceled accordingly at the
passengers exit the car. appropriate time.
Automatic Hall Call If one car cannot carry all waiting passengers because it is full, another car Car Allocation Tuning (CAT) The number of cars allocated or parked on crowded floors are controlled not
Registration (FSAT) will automatically be assigned for the remaining passengers. just according to the conditions on those crowded floors but also the operational
status of each car and the traffic on each floor.
Car Call Canceling (CCC) When a car has responded to the final car call in one direction, the system
regards remaining calls in the other direction as mistakes and clears them Dynamic Rule-Set Optimizer Traffic flows in a building are constantly predicted using neural network
from the memory. (DRO) technology, and an optimum rule-set for group control operations is
selected through real-time simulations based on prediction results.
False Call Canceling If the number of registered car calls does not correspond to the car load, all #1 #1 #1 Please refer to page 12.
— Automatic (FCC-A) calls are canceled to avoid unnecessary stops. Destination Oriented When a passenger enters a destination floor at a hall, the hall operating
Prediction System (DOAS-S) panel indicates which car will serve the floor. The passenger does not #5
False Call Canceling If the wrong car button is pressed, it can be canceled by quickly pressing #1 #1 #1 #1 need to press a button in the car. Dispersing passengers by destination
— Car Button Type (FCC-P) the same button again twice. prevents congestion in the cars and minimizes their waiting and traveling
Features
time. (Cannot be combined with IUP.) Please refer to page 12.
Car Fan Shut Off If there are no calls for a specified period, the car ventilation fan will
— Automatic (CFO-A) automatically turn off to conserve energy. Please refer to page 6. Peak Traffic Control (PTC) A floor which temporarily has the heaviest traffic will be served with higher
priority over other floors, but not to the extent that it interferes with the
Car Light Shut Off If there are no calls for a specified period, the car lighting will automatically service to other floors.
— Automatic (CLO-A) be turned off to conserve energy. Please refer to page 6. Strategic Overall Spotting To reduce passenger waiting time, cars which have finished service are
(SOHS) automatically directed to positions where they can respond to predicted
Backup Operation for Group An operation by car controllers which automatically starts to maintain hall calls as quickly as possible.
Control Microprocessor elevator operation in the event that a microprocessor or transmission line
(GCBK) in the group controller has failed. Intense Up Peak (IUP) To maximize transport efficiency, an elevator bank is divided into two
groups of cars to serve upper and lower floors separately during up peak.
Out-of-Service-Remote (RCS) With a key switch on the supervisory panel, etc., a car can be called to a In addition, the number of cars to be allocated, the timing of car allocation
specified floor after responding to all car calls, and then automatically be to the lobby floor, the timing of door closing, etc. are controlled based on
taken out of service. predicted traffic data.
Secret Call Service (SCS-B) To enhance security, car calls for desired floors can be registered only by Up Peak Service (UPS) Controls the number of cars to be allocated to the lobby floor, as well as
entering secret codes using the car buttons on the car operating panel. the car allocation timing, in order to meet increased demands for upward
This function is automatically deactivated during emergency operation. travel from the lobby floor during office starting time, hotel check-in time,
etc., and minimize passenger waiting time.
Non-Service to Specific Floors To enhance security, service to specific floors can be disabled using the car
— Car Button Type (NS-CB) operating panel. This function is automatically deactivated during Down Peak Service (DPS) Controls the number of cars to be allocated and the timing of car
emergency operation. allocation in order to meet increased demands for downward travel
during office leaving time, hotel check-out time etc. to minimize
Non-Service to Specific Floors To enhance security, service to specific floors can be disabled using a passenger waiting time.
#2
— Switch/Timer Type manual or timer switch. This function is automatically deactivated during Forced Floor Stop (FFS) All cars in a bank automatically make a stop at a predetermined floor on
(NS/NS-T) emergency operation. every trip without being called.
Out-of-Service by Hall Key For maintenance or energy-saving measures, a car can be taken out of Main Floor Parking (MFP) An available car always parks on the main (lobby) floor with the doors open
Switch (HOS/HOS-T) service temporarily with a key switch (with or without a timer) mounted in to reduce passenger waiting time.
a specified hall.
Energy-Saving Operation To save energy, the number of service cars is automatically reduced to
Return Operation (RET) Using a key switch on the supervisory panel, a car can be withdrawn from — Number of Cars (ESO-N) some extent, but not so much that it adversely affects passenger waiting
group control operation and called to a specified floor. The car will park on time. Please refer to page 6.
that floor with the doors open, and not accept any calls until independent Energy-Saving Operation When a call is registered, the system controls car assignment, considering near-future
operations begin. — Allocation Control (ESO-W) traveling distance of all elevators to conserve energy. Please refer to page 6.
Attendant Service (AS) Exclusive operation where an elevator can be operated using the buttons Special Floor Priority Service Special floors, such as floors with VIP rooms or executive rooms, are given
and switches located in the car operating panel, allowing smooth boarding #2
(SFPS) higher priority for car allocation when a call is made on those floors.
of passengers or loading of baggage. (Cannot be combined with hall position indicators.)
Independent Service (IND) Exclusive operation where a car is withdrawn from group control operation Notes: • 1C-2BC (1-car selective collective) - Standard, 2C-2BC (2-car selective collective) - Optional
for independent use, such as maintenance or repair, and responds only to ΣAI-22 (3 to 4-car group control system) - Optional, ΣAI-2200C (3 to 8-car group control system) - Optional
car calls. • = Standard = Optional = Not applicable
• #1: Standard feature when the rated capacity is from 1600kg to 2500kg.
Variable Traveling Speed NEW According to the number of passengers in the car, the car travels faster #3 #3 #3 #3
• #2: Please consult our local agents for the production terms, etc.
Elevator System (VSE) than the rated speed. Please refer to page 7 and 8. • #3: The Variable Traveling Speed Elevator System (VSE) is applicable to the elevators with a rated speed of 1.0m/sec and the rated capacity of 630kg to 1600kg.
• #4: The Regenerative Converter (PCNV) is applicable to the elevators with the capacity of 630kg to 1600kg.
Regenerative Converter NEW For energy conservation, power regenerated by a traction machine can be #4 #4 #4 #4
• #5: When DOAS-S is applied, SR or Multi-Beam Door Sensor should be installed.
(PCNV) used by other electrical systems in the building. Please refer to page 5. Please consult our local agents when DOAS-S hall operating panels are installed on all floors.
31 32
Features
Feature Description 1C- 2C- 3C to 4C 3C to 8C Feature Description 1C- 2C- 3C to 4C 3C to 8C
2BC 2BC ΣAI-22 ΣAI-2200C 2BC 2BC ΣAI-22 ΣAI-2200C
Closest-Car Priority Service A function to give priority allocation to the car closest to the floor where a ■ SIGNAL AND DISPLAY FEATURES
(CNPS) hall call button has been pressed, or to reverse the closing doors of the car #1
Sonic Car Button — Click A click-type car button which emits electronic beep sounds when pressed
closest to the pressed hall call button on that floor. (Cannot be combined
Type (ACB) to indicate that the call has been registered.
with hall position indicators.)
Light-Load Car Priority Service When traffic is light, empty or lightly-loaded cars are given higher priority Car Arrival Chime — Car or Electronic chimes sound to indicate that a car will soon arrive. (The chimes
#1 Hall (AECC/AECH) are mounted either on the top and bottom of the car, or in each hall.) (Each floor)
(UCPS) to respond to hall calls in order to minimize passenger travel time. (Cannot
be combined with hall position indicators.) Flashing Hall Lantern (FHL) A hall lantern, which corresponds to a car’s service direction, flashes to
Special Car Priority Service Special cars, such as observation elevators and elevators with basement indicate that the car will soon arrive.
#1
(SCPS) service, are given higher priority to respond to hall calls. (Cannot be Immediate Prediction When a passenger has registered a hall call, the best car to respond to that
combined with hall position indicators.) Indication (AIL) call is immediately selected, the corresponding hall lantern lights up and a
Congested-Floor Service The timing of car allocation and the number of cars to be allocated to chime sounds once to indicate which doors will open.
(CFS) floors where meeting rooms or ballrooms exist and the traffic intensifies for Second Car Prediction (TCP) When a hall is crowded to the extent that one car cannot accommodate all
short periods of time are controlled according to the detected traffic waiting passengers, the hall lantern will light up to indicate the next car to
density data for those floors. serve the hall.
Bank-Separation Operation Hall buttons and the cars called by each button can be divided into several #1 Basic Announcement (AAN-B) A synthetic voice (and/or buzzer) alerts passengers inside a car that elevator #2 #2 #2
(BSO) groups for independent group control operation to serve special needs or operation has been temporarily interrupted by overloading or a similar
different floors. cause. (Voice available only in English.)
VIP Operation (VIP-S) A specified car is withdrawn from group control operation for VIP service
#1 Voice Guidance System Information on elevator service such as the current floor or service direction
operation. When activated, the car responds only to existing car calls,
(AAN-G) is given to the passengers inside a car. (Voice guidance available only in
moves to a specified floor and parks there with the doors open. The car
English.)
will then respond only to car calls.
Lunchtime Service (LTS) During the first half of lunchtime, calls for a restaurant floor are served with Auxiliary Car Operating Panel An additional car control panel which can be installed for large-capacity
higher priority, and during the latter half, the number of cars allocated to (ACS) elevators, heavy-traffic elevators, etc.
the restaurant floor, the allocation timing for each car and the door Inter Communication System A system which allows communication between passengers inside a car
opening and closing timing are all controlled based on predicted data. (ITP) and the building personnel.
Main Floor Changeover This feature is effective for buildings with two main (lobby) floors. The floor LCD Position Indicator (CID-S) LCD information display mounted inside a car on the car operating panel
Operation (TFS) designated as the “Main floor” in a group control operation can be changed that indicates the date and time, current car position and travel direction.
as necessary using a manual switch.
■ EMERGENCY OPERATIONS AND FEATURES
Features
■ DOOR OPERATION FEATURES
Mitsubishi Emergency Landing Upon power failure, a car equipped with this function automatically moves
Door Sensor Self-Diagnosis Failure of non-contact door sensors is checked automatically, and if a Device (MELD) and stops at the nearest floor using a rechargeable battery, and the doors
(DODA) problem is diagnosed, the door close timing is delayed and the closing open to facilitate the safe evacuation of passengers. (Maximum allowable
speed is reduced to maintain elevator service and ensure passenger safety. floor-to-floor distance is 10 meters.)
Automatic Door Speed Control Door load on each floor, which can depend on the type of hall door, is
Operation by Emergency Power Upon power failure, predetermined car(s) uses the building’s emergency
(DSAC) monitored to adjust the door speed, thereby making the door speed Source — Automatic/Manual power supply to move to a specified floor, where the doors then open to
consistent throughout all floors. (OEPS) facilitate the safe evacuation of passengers. After all predetermined car(s)
Automatic Door-Open Time The time doors are open will automatically be adjusted, depending on have arrived at the floor, normal operation will be available with only
Adjustment (DOT) whether the stop was called from the hall or the car, to allow smooth predetermined car(s).
boarding of passengers or loading of baggage.
Fire Emergency Return (FER) Upon activation of a key switch or a building’s fire sensors, all calls are
Reopen with Hall Button Closing doors can be reopened by pressing the hall button corresponding canceled, all cars immediately return to a specified evacuation floor and the
(ROHB) to the traveling direction of the car. doors open to facilitate the safe evacuation of passengers.
Repeated Door-Close (RDC) Should an obstacle prevent the doors from closing, the doors will repeatedly Firefighters’ Emergency During a fire, when the fire operation switch is activated, the car calls of a
open and close until the obstacle is cleared from the doorway. Operation (FE) specified car and all hall calls are canceled and the car immediately returns
Extended Door-Open Button When the button inside a car is pressed, the doors will remain open longer to a predetermined floor. The car then responds only to car calls which
(DKO-TB) to allow loading and unloading of a stretcher, baggage, etc. facilitate fire-fighting and rescue operations.
Door Nudging Feature A buzzer sounds and the doors slowly close when they have remained Earthquake Emergency Return Upon activation of primary and/or secondary wave seismic sensors, all cars
— With Buzzer (NDG) open for longer than the preset period. With AAN-B or AAN-G, a beep and (EER-P/EER-S) stop at the nearest floor, and park there with the doors open to facilitate
voice guidance sound instead of the buzzer. the safe evacuation of passengers.
Door Load Detector (DLD) When excessive door load has been detected while opening or closing, the Supervisory Panel (WP) Each elevator’s status and operation can be remotely monitored and #1 #1
doors immediately reverse. controlled through a panel installed in a building’s supervisory room, etc.
Safety Door One side #2 #2 #2 #2 MelEye (WP-W) Each elevator’s status and operations can be monitored and controlled
Edge (SDE) (CO, 2S doors) Sensitive door edge(s) detects passengers or objects during door closing. Mitsubishi Elevators & using an advanced Web-based technology which provides an interface
Both sides (Cannot be combined with the MBSS feature.) #2 #2 #2 #2 Escalators Monitoring and through personal computers. Special optional features such as preparation
(CO doors only) Control System of traffic statistics and analysis are also available.
#3 #3 #3 #3 Emergency Car Lighting (ECL) Car lighting which turns on immediately when power fails, providing a
Safety Ray 1-Beam One or two infrared-light beams cover the full width of the doors as they minimum level of lighting within the car. (Choice of dry-cell battery or
(SR) open or close to detect passengers or objects. (Cannot be combined with trickle-charge battery.)
2-Beam the multi-beam door sensor or MBSS feature.)
Electronic Doorman (EDM) Door open time is minimized using safety ray(s) or multi-beam door Notes: • 1C-2BC (1-car selective collective) - Standard, 2C-2BC (2-car selective collective) - Optional
sensors that detect passengers boarding or exiting. ΣAI-22 (3 to 4-car group control system) - Optional, ΣAI-2200C (3 to 8-car group control system) - Optional
• = Standard = Optional = Not applicable
Multi-Beam Door Sensor Multiple infrared-light beams cover a door height of approximately • #1: Please consult our local agents for the production terms, etc.
1800mm to detect passengers or objects as the doors close. (Cannot be • #2: Standard feature when the rated capacity is from 1600kg to 2500kg.
combined with the SR or MBSS feature.) • #3: Optional feature when the rated capacity is from 1600kg to 2500kg.
Multi-Beam Door Sensor Multiple infrared-light beams cover a door height of approximately • #4: Not available when the rated capacity is from 1600kg to 2500kg.
— Signal Type (MBSS) 1800mm to detect passengers or objects as the doors close. Additionally, #4 #4 #4 #4
LED lights on the door edge will light up to indicate door opening or
closing as well as detection of passengers. (Cannot be combined with any
of the following features: SDE, SR or multi-beam door sensor.)
Hall Motion Sensor (HMS) Infrared-light is used to scan a 3D area near the open doors to detect
passengers or objects.
33 34
Basic Specifications
Horizontal Dimensions <1-Door 1-Gate (1D1G)> Please refer to page 37 for the horizontal dimensions for 1-Door 2-Gate. Specifications for Variable Traveling
Code number Number of Rated
capacity Door type
Counter-
weight
Car internal
dimensions (mm)
Entrance
width (mm)
Minimum hoistway
dimensions (mm)
Speed Elevator System (Optional)
persons <1-Door 1-Gate (1D1G) & 1-Door 2-Gate (1D2G)>
(kg) position AAxBB JJ XxY
900: Standard 1950x1720
CO Minimum Minimum pit
800: Optional 1800x1720 Rated speed Speeds Rated capacity
P8 8 630 1100x1400 overhead (mm) depth (mm)
900: Standard (m/sec) (m/sec) (kg)
2S 1650x1800 OH PD
800: Optional ~1050 3750 1400
900: Standard 2025x1720 1.0 1.0/1.25/1.5/1.6
CO ~1600 4250 1650
800: Optional 1925x1720
P11 11 825 1350x1400
900: Standard 1900x1800 [ Terms of the table]
2S • The Variable Traveling Speed Elevator System (VSE) is applicable to the elevators with a rated speed of 1.0m/sec and
1100: Optional 1950x1800
Side the rated capacity of 630kg to 1600kg.
1100: Standard 2415x1720
P14 CO • Except minimum overhead and pit depth dimensions (OH and PD), specifications shown in tables, “Horizontal
1600x1400 900: Optional 2215x1720
Wide type Dimensions” and “Vertical Dimensions”, on the page 35 and 37 are applicable to the Variable Traveling Speed System.
2S 1100 2215x1800
14 1050 900: Standard 1965x2420
CO
P14 800: Optional 1865x2420
1100x2100
Deep type 900: Standard
2S 1715x2500
800: Optional
P17 17 1275
CO
2S
Rear
Side
2000x1400
1200x2300 1100
2490x1960
2065x2670 Hoistway Plan Hoistway Section
CO Rear 2100x1600 2590x2160
P21 21 1600
1400x2400 1200 2215x2770
Hoistway width: X X
P27 27 2025 2S Side 1500x2700 2520x3160
1300
P33 33 2500 1800x2700 2820x3160
Hoistway depth: Y
[ Terms of the table] Car internal
width: AA AA
Overhead: OH
• The contents of this table are applied to standard specification only. Please consult our local agents for other specifications.
Car internal
Y
depth: BB
• Rated capacity is calculated at 75kg per person, as required by the EN81-1.
BB
Entrance height: HH
2200 (standard)
2100 (standard)
• CO: 2-panel center opening doors, 2S: 2-panel side sliding doors.
Basic Specifications
Ceiling height
• Minimum hoistway dimensions (X and Y) are after waterproofing of pit and do not include plumb tolerance.
• Minimum hoistway dimensions (X and Y) should be increased if fireproof landing door is required. Entrance
width: JJ JJ
Maximum travel: TR
Maximum Minimum Minimum Minimum
Rated speed Rated capacity Maximum travel number overhead (mm) pit depth (mm) floor height
(m/sec) (kg) (m) of floors OH PD (mm)
BB
BB
~2025 1630
Y
4220 AA
~2500 1730
~1050 80 30 3750 1400
~1600 70 26 4250 1650
1.6 2500
Pit depth: PD
~2025 1730
60 22 4380
~2500 1730 JJ JJ
~1050 80 30 3850 1450 Shown for 2S doors Shown for 2S doors
~1600 70 26 4350 1700 Counterweight side drop Counterweight side drop Note: Hoistway section for Capacity of 1275 ~ 1600kg is
1.75 (Capacity 630kg ~ 1050kg) (Capacity 1275kg ~ 2500kg)
~2025 1770 slightly different from this figure.
60 22 4440
~2500 1770
35 36
Basic Specifications Important Information
on Elevator Planning
Horizontal Dimensions <1-Door 2-Gate (1D2G)>
Rated Counter- Car internal Entrance Minimum hoistway
Number of
Code number capacity Door type weight dimensions (mm) width (mm) dimensions (mm)
persons (kg) position AAxBB JJ XxY Work Not Included in Elevator Contract
900: Standard 1965x1860
CO The following items are excluded from Mitsubishi Electric’s elevator installation work, and are therefore the responsibility of the
800: Optional 1865x1860
P8 8 630 1100x1400
2S
900: Standard 1715x1982 building owner or general contractor:
800: Optional
900: Standard
1650x1982
2090x1860
• Architectural finishing of the walls and floors in the vicinity of the entrance hall after installation has been completed.
P11 11 825
CO
1350x1400
800: Optional 1925x1860 • Construction of an illuminated, ventilated and waterproofed elevator hoistway.
2S
900: Standard
1100: Optional
1900x1982
1965x1982
• A ladder to the elevator pit.
P14 CO
Side 1100: Standard 2415x1860 • Provision for cutting the necessary openings and joists.
Wide type
2S
1600x1400 900: Optional
1100
2215x1860
2215x1982
• Separate beams, when the hoistway dimensions markedly exceed the specifications, and intermediate beams when two or more
14 1050 900: Standard 1965x2560
elevators are installed.
P14
CO
1100x2100
800: Optional 1865x2560 • All other work related to building construction.
Deep type 900: Standard
800: Optional
1715x2682 • The power-receiving panel and the electrical wiring for illumination, plus the power from them to the electrical room.
P17 17 1275
2S
1200x2300 1100 2065x2882 • The laying of conduits and wiring between the elevator pit and the terminating point for the devices installed outside the hoistway,
P21 21 1600 1400x2400 1200 2215x2982 such as the emergency bell, intercom, monitoring and security devices, etc.
[ Terms of the table] • The power consumed in installation work and test operations.
• The contents of this table are applied to standard specification only. Please consult our local agents for other specifications.
• Rated capacity is calculated at 75kg per person, as required by the EN81-1. • The test provision and subsequent alteration as required, and eventual removal of the scaffolding as required by the elevator
• CO: 2-panel center opening doors, 2S: 2-panel side sliding doors. contractor, and any other protection of the work as may be required during the process.
• Minimum hoistway dimensions (X and Y) are after waterproofing of pit and do not include plumb tolerance.
• Minimum hoistway dimensions (X and Y) should be increased if fireproof landing door is required. • The provision of a suitable, locked space for the storage of elevator equipment and tools during elevator installation.
• The security system, such as a card reader, connected to Mitsubishi Electric’s elevator controller, when supplied by the building
Hoistway Plan Hoistway Section owner or general contractor.
Basic Specifications
* Work responsibilities in installation and construction shall be determined according to local laws. Please consult our local agents for details.
Important Information
Elevator Site Requirements
Hoistway width: X
Entrance
width: JJ
Entrance height: HH
Car internal
2200 (standard)
2100 (standard)
width: AA
Ceiling height
a. The relative humidity shall be below 90% on a monthly average and below 95% on a daily average.
Car internal
depth: BB
b. The elevator hoistway shall be finished with mortar or other materials so as to prevent concrete dust.
• Voltage fluctuation shall be within a range of +5% to -10%.
Entrance
Ordering Information
width: JJ
• Operation system.
• Selected design and size of car.
AA
Y
BB
• Entrance design.
• Signal equipment.
Pit depth: PD
JJ • A sketch of the part of the building where the elevators are to be installed.
Shown for 2S doors
Counterweight side drop • The voltage, number of phases, and frequency of the power source for
the motor and lighting.
Applicable Standards
The ELENESSA complies with the EN81-1 code. For details of compliance with other national regulations, Mitsubishi Elevator Inazawa Works has acquired ISO 9001 certification
please consult our local agents. by the International Standards Organization (ISO) based on a review of
quality management.
The company has also acquired environmental management system
Please refer to page 36 for the vertical dimensions and the specifications for the Variable Traveling Speed System Elevator. standard ISO 14001 certification.
37 38
Inquiries and orders should be directed to the following offices. (Some products may not be available for sale in some countries.)