C.4. The vehicle must have reinforced and raised suspension for rough terrain access
C.9. The vehicle must have a minimum urban traffic of at least 500 km
C.10. The vehicle must be provided with metallic protection under the powertrain
C.13. The electrical system must contain at least 4 separates power subsystems :
C.14. The warning system must work even when the engine is stopped
C.16. Must have a handle for the driver’s attendant, located near the lower corner of
the windscreen or above the entry door
C.20. Must have video system with connection to the acoustic and lighting system,
with the possibility of image, sound and data recording of the speed,
acceleration and GPS position. Will be provided with the soft for data analyze
C.21. Must have console with studs for command of the acoustic and visual warning
system
C.22. Must have remote control for warning system that includes a microphone
C.23. Must have navigation system with GPS that run a navigation map soft for entire
Romania
Patient compartment
C.24. Must be designed that one or several persons can work in a vertical position
under comfortable conditions
C.25. The roof, interior walls and doors of the compartment must be coated with
washable materials
C.29. Must have one or several handle above the stretcher , on longitudinal axis
C.30. The left wall (on driver side) must be used to secure the medical equipment or
the batteries of the portable medical equipment , such as: secretion suction,
oxygen transport system
C.31. The vehicle must allow the transportation of one patient on the stretcher and
three on the seats
C.33. On the wall, near the patient, must be one cabinet for medicines, fixed , with
locking system
C.34. The stretcher support will be located in the left side of the compartment
C.35. The storage space of the above mentioned equipment must be as small as
possible in the medical compartment so as not to become an impediment to
staff moving around the patient, according European standard EN 1789
C.37. The parts of the wall located outside the windows, above the stretcher level
(included the cabinets and drawers) must absorb shocks and made of washable
materials.
a. 2 rear doors for patient access and one right side door for access of the
specialized personnel
b. Sliding window on the side door of the patient compartment
c. 2 windows on the rear doors of the patient compartment
C.44. The noise level in interior , depending the on the running speed, will be
according with HG nr.674/2007
C.45. Must be provided with at least 2 sockets -12 V for medical devices
C.46. All the circuits from the inside patient compartment will have separate fuses or
switches provided by the building
C.48. The medical part will have at least 2 circuits so in case of a malfunction of one
circuit not to disturb the lighting and medical devices
C.49. The cables and pipes must withstand vibrations. The cables will not cross the
area where gaseous substances are used
C.50. The Ambulance will be provided with optical and acoustic warning system
composed of:
a. Blue light bar with 2 stroboscopic xenon lamps, fixed above dividing
wall
b. 2 blue signaling lamps – stroboscopic , integrated in the front grille
c. 2 blue beacons with xenon lamps located on the roof, in the rear of
ambulance, visible from all directions; the beacons will be homologated
according R 65 CEE-ONU and will be placed according 74/483 CEE
d. The general switcher, that connect the warning system to the vehicle
electrical system
C.52. Mobile radio broadcast station MTM 800 series, purchased and installed by
MApN
C.53. Portable radio broadcast station MTP 850 series, purchased and installed by
MApN
C.54. The provider will anticipate and assure the technical conditions for electrical
installation and supply of the mobile radio broadcast station MTM 800 series in
the driver’s cabin
C.55. Interphone that assure the duplex voice communication between driver’s
compartment and patient compartment
C.56. The essential devices for an intervention outside of the vehicle must be easy
accessible through the ambulances doors
C.57. The medical devices must allow their use both in travel conditions and
stationary
C.62. Stationary oxygen - at least 2 bottles x 10l each equipped with NTP, flow rate /
valve meter, flow capacity of at least 15 l / min and control valve; fast
connection, humidifier and facial mask
C.63. Portable oxygen - at least 5 l ,equipped with NTP, flow rate / valve meter, flow
capacity of at least 15 l / min and control valve; fast connection, humidifier and
facial mask
C.64. Ventilation balloon adult/child with different sizes and additional oxygen tank
C.71. Stethoscope
C.76. Thermometer
Sanitary materials:
C.86. Portable container for replanting while keeping the internal temperature at 4 ±
2° C for at least 2 hours
C.97. Blankets
C.104. Flashlight with batteries, with the possibility of charging the batteries on the
vehicle
C.105. Fire extinguisher
C.108. An infusion support that will ensure the possibility of sustaining three infusions,
vertically fixed in such a manner that the height of the vehicle above the whole
assembly can be used
C.109. The support system will have a capacity of at least 5 kg and will be able to
support three liquid bags, independent of each other
Reliability requirements
C.110. The uninterrupted operating time will be at least 8 hours for all equipment
Maintenance requirements
C.115. The hardware and software structure will be conceived in a modular system
that facilitates access to troubleshoot and, at the same time, allow separate
testing of each module
C.119. The medical equipment should not be influenced by the sudden temperature
changes
Transport
C.122. The ambulance will be able to circulate on all land transport routes arranged for
public car traffic
Electromagnetic compatibility
C.123. From the point of view of electromagnetic compatibility, the product must
comply with the requirements of IEC 60601-1 Ed.3.1 Medical electrical
equipment – Part 1-2: General requirements for basic safety and essential
performance – Collateral standard: Electromagnetic disturbances –
Requirements and test.
C.125. The details on the inscriptions will be settle after with the company that wins
the Tender
Interchangeability
Safety in exploitation
C.127. The ambulance, equipment and devices will function according to the labor
protection rules and will have the following safety systems:
a. ABS
b. Emergency braking assistance
c. ESP
d. Front airbags
e. Pretension safety belts
f. Central locking
Storage