Part�no. DILEM-10(110V50HZ,120V60HZ)
Article�no. 051783
Catalog�No. XTMC9A10A
Delivery�programme
Product range Contactors
Pole 3 pole
Rated�operational�current
AC-3
380 V 400 V Ie A 9
AC-1
Open
at 40 °C Ith =Ie A 22
Max.�rating�for�three-phase�motors,�50�-�60�Hz
AC-3
380 V 400 V P kW 4
660 V 690 V P kW 4
AC-4
380 V 400 V P kW 3
660 V 690 V P kW 3
Contacts
Contact sequence
Technical�data
General
Standards IEC/EN 60947, VDE 0660, CSA, UL
Ambient temperature
Enclosed °C - 25 - 40
Mounting position As required, except vertical with terminals A1/A2 at the bottom
Mounting position
Half-sinusoidal shock, 10 ms
Make g 10
Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof
Weight kg 0.2
Screw terminals
Solid mm
2 1 x (0.75 - 2.5)
2 x (0.75 - 2.5)
Breaking capacity
220 V 230 V A 90
380 V 400 V A 90
500 V A 64
660 V 690 V A 42
Open
at 40 °C Ith =Ie A 22
at 50 °C Ith =Ie A 20
at 55 °C Ith =Ie A 19
enclosed Ith A 16
open Ith A 50
enclosed Ith A 40
AC-3
220 V 230 V Ie A 9
240 V Ie A 9
380 V 400 V Ie A 9
415 V Ie A 9
440V Ie A 9
500 V Ie A 6.4
240V P kW 2.5
380 V 400 V P kW 4
415 V P kW 4.3
440 V P kW 4
500 V P kW 4
660 V 690 V P kW 4
AC-4
240 V Ie A 6.6
415 V Ie A 6.6
440 V Ie A 6.6
500 V Ie A 5
240 V P kW 1.8
380 V 400 V P kW 3
415 V P kW 3.1
440 V P kW 3
500 V P kW 3
660 V 690 V P kW 3
DC
Rated operational current open
12 V Ie A 20
24 V Ie A 20
60 V Ie A 20
110 V Ie A 20
220 V Ie A 20
DC - 3
12 V Ie A 8
24 V Ie A 8
60 V Ie A 4
110 V Ie A 3
DC - 5
12 V Ie A 2.5
24 V Ie A 2.5
60 V Ie A 2.5
110 V Ie A 1.5
220 V Ie A 0.3
to Ith W 2
at Ie to AC-3/400 V W 0.5
Magnet�systems
Voltage tolerance
AC operated
Power consumption
AC operation
Make contact ms
Closing delay ms
Opening delay ms
Reversing contactors
Auxiliary�contacts
Positive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact Yes
module
AC-15
220 V 240 V Ie A 6
380 V 415 V Ie A 3
500 V Ie A 1.5
DC L/R 15 ms
Contacts in series: A
1 24 V A 2.5
2 60 V A 2.5
3 100 V A 1.5
3 220 V A 0.5
AC-15 Operations x 10
6 0.2
DC current
Notes Switch-on and switch-off conditions based on DC-13, time constant as specified
500 V A gG/gL 6
500 V A fast 10
Design�verification�as�per�IEC/EN�61439
Technical data for design verification
10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements.
10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances Meets the product standard's requirements.
10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility.
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will
provide heat dissipation data for the devices.
10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be
observed.
10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be
observed.
10.13 Mechanical function The device meets the requirements, provided the information in the instruction
leaflet (IL) is observed.
Technical�data�ETIM�6.0
Low-voltage industrial components (EG000017) / Power contactor, AC switching (EC000066)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Power contactor, AC switching (ecl@ss8.1-27-37-10-03 [AAB718012])
Modular version No
Approvals
Product Standards IEC/EN 60947-4-1; UL 508; CSA-C22.2 No. 14-05; CE marking
1: Overload relay
2: Suppressor
3: Auxiliary contact modules
Enclosure totally insulated
Dimensions
Additional�product�information�(links)
IL03407009Z�(AWA2100-0882)�Mini�contactor�relay