Вы находитесь на странице: 1из 1
Blow By Sensor Installation Tips ‘The Blow By Sensor lets you measure the CFM flow from your crankcase. To be accurate you Mount with Ball “plugs” on top should seal up the crankcase, valve covers, ete. You should eliminate any type of PCV valve, or routing of the crankcase vapors out of the engine, ‘Typically you will have the breather of one rocker ‘cover as being the only outlet of blow by gasses. Figure 1 ‘Sensor with a large diameter, non restrictive hose. date romseancve mses oasete wel | non ‘The Blow By sensor should be mounted This side is upstream side approximately level, with the side with the 2 ball plugs on top. The round section with the notch for the sensor lead is the upstream side of the sensor, See Figure 1 ‘The sensor may collect liquid from condensation and oll vapors. You should periodically check by removing hoses and letting hoses drain, and tipping condensation out of both sides of sensor. When moving sensor which has accumulated liquid, be careful to keep the ball “plugs” up, so liquid can not get to this top side of the channel inside the meter. Beets Cab Exe Tae GTO TTI Sopsel aieben Table: alts Data Volts Data In the DataMite software, pick Blowby Sensor for your range of sensor as the Type (Fig 2). Figure 2 also shows the Analog Sencot Spece 4 fis 0 F fees [940 caliration for older DataMite | type [euton (use swnfey ably. +] 8 [32] & [aes 10.56 Sofware o for other dyno Footer tes vig) SII ees tae] lee Aer computers. The output is non- ate ae ie ie CEM Dios |¢.co | (ass 25 linear and requires you to Figure 2 E psa] J [s —]133 select the Type as “Custom (user supplies table)" as shown, This will open up the right side of the screen called “Sensor Calibration Table”. 125 ‘Analog Sensor Specs You can choose any Data Name you want. Then set the “Signal Based On’ to "0-5 Volts". Fillin he table with the| Signa Based On ots Rl 10 pairs of values shown. 0 Later versions of 1.05 Voks 455 ‘The Blow By Sensor does _ | software list aE neal @Hea DOES puta small restriction on the |Blowby Sensor in|, and ft inthe Cation blowby flow, and therefore _|the list of “Types”. film Fam factory Clear Row Insert Row does put a small pressure on | Be sure to pick the ed vith senso) The Relate nese TES ANEGSS the crankcase. A signal of 2 | correct range for _feant for an adiustmeni alter volts (about 6.7 CFM) will | your particular plete, For enamel, afer produce 0.16 psi pressure. |Blowby Sensor. |ramrtnadearins toread At full scale of 5 Volts (about ake ide height 13,3 CFM), the pressure will Keep Specs | Helo| Cancel | Print be about 06 psi (©) 2007 Performance Trends Inc, Box 630164, Livonia MI, 48163 249-473-9230 feedback@performancetrends.com, www.performancetrends.com Performance Trende reserves the right to change or discontinue any product at any time

Вам также может понравиться