According to the normative P100/1-2013 it has the ground acceleration ag = 0.25g The
importance class of the building and III (𝛾=1.0)
According to the normative CR 1-1-4-2012 the reffence value for dynamic pressure of the
wind qb = 0.7 [kPa]
According to the normative CR 1-1-3-2012 the characteristic value for the snow load:
Sk = 2,5 [kN/m2] and zone ’C’ from the actions point of view given by the snow.
The deep freeze according to STAS 6054/77 is 90 [cm] from terrain surface.
- Geotechnical conditions
The exterior walls will be realized by B.C.A masonry and the mortar will be M5, they will
be insulated with a layer of extruded polystyrene with thickness of 10 cm.
The interior walls will be realized by gypsum board plates isolated with mineral wool with
thickness of 10 or 15 [cm]
The columns and the girder which are situated at the exterior will be plated with extruded
polystyrene of 10 cm to avoid the formation of the condensation in the zone of thermal bridges.
The materials used in the execution of the structure are : concrete with class C20/25
and the reinforcement PC52 and OB37.
Staircase will be realized by monolith concrete C20/25.
The slab over the ground floor and floors will be realized with monolith concrete C20/25
with thickness of 13 cm and it will be reinforced with PC52 and OB37.
2.1.4 Description of infrastructure
Taking into account the nature of the terrain where the building is located, described by
the geotechnical study, the system of foundation is
- isolated foundations with reinforcement concrete block layered having the height 1.0 [m];
- orthogonal reinforced concrete frames;
- monolith reinforced concrete floors;