Вы находитесь на странице: 1из 2

Seismic Analysis As per NSCP 2015 Standards

Design Base Shear - Static Force Procedure


Seismic Zone, Z 0.4 Height of Structure, hn 6.2 m
Seismic Coefficient, Cv 0.64Nv Near Source Factor, Na 1
Seismic Coefficient, Ca 0.44Na Near Source Factor, Nv 1
Resisting Structural System, R 8.5 Closest Distance To
40 km
Importance Factor, I 1 Known Seismic Source
Total Weight, W 560.75 kN
Soil Profile Type SD (Stiff Soil Profile)
Occupancy Category IV (Standard Occupancy Structures)
Ct 0.0731 (Reinforced concrete moment-resisting frames )

Weight Calculation
Roof Level
Roofing Material = 50.00 kN
Walls = 96.48 kN
Beams = 19.98 kN
Columns = 11.52 kN
Σ = 177.98 kN

2nd Floor Level


Walls = 176.88 kN
Slabs = 72.00 kN
Finishes and Ceiling = 42.00 kN
Beams = 68.85 kN
Columns = 23.04 kN
Σ = 382.77 kN

Total Weight = 560.75 kN

Base Shear Computation


CvI
V= W (208-8)
RT
T = Ct(hn)3/4 ,Structure Period in seconds (208-12)
T = 0.0731(6.2)^(3/4)= 0.2872 s
Cv = 0.64(1) = 0.64
0.64(1)(560.75)
V= = 147.01 kN
8.5(0.2872)

But total base shear shall not exceed:


2.5CaI
V= W (208-9)
R
Ca = 0.44(1) = 0.44
2.5 (0.44)(1)(560.75)
V= = 72.57 kN
8.5
But total base shear shall not be less than:
V = 0.11CaIW (208-10)
V = 0.11(0.44)(1)(560.75)= 27.14 kN

For Seismix Zone 4, the total base shear shall also not be less than:
0.8NvI
V= W (208-11)
R
0.8 (1)(1)(560.75)
V= = 52.78 kN
8.5

Therefore, adopt 72.57 kN for base shear design

Base Shear Distribution per Level


Ft = 0.07TV (208-16)
(208-17)
Ft = 0, since T ≤ 0.7 s
Level hx (m) wx (kN) wxhx Fx (kN) but not greater than 0.25V = 18.1425
Roof 6.2 177.98 1103.48 34.39
2F 3.2 382.77 1224.86 38.18
Σ 560.75 2328.34 72.57