Вы находитесь на странице: 1из 113
GA Packano 43130A DEFIBRILLATOR PART NUMBER 43130-91909 MICROFICHE NUMBER 43130-90999 This manual applies to instruments beginning with serial number prefix 28124. Fifth Edition ©Copyright Hewlet-Packard Company 1985, 1986, 1987, 1988, 1989, The document contains or refers to proprietary infor "mation whichis protected by copyright, All ighs ae reserved. Copying r oer reproduction of this document is prohibited without the prior writen permission of Hewett Packard Company. McMINNVILLE DIVISION 1700 South Baker Street McMinnville, Oregon 97128 r SECTION | - GENERAL INFORMATION General Information Operating Controls And Indicators. Emergency Defibrillation Procedure Elective Cardioversion. . Checkout Procedure (43130A) Operator Service. Operational Checks SECTION II - THEORY Introduction ‘System Overview. Control Board. ...... Main Control Processor. . Control Gate Array. Clock Oscillator Memory Mapped 1/0 = Gate Array Control Registers. Analog/Digital Conversion ECGISYNC Pulse Input Butter Peak Current Detector Switch Control Logic... Speaker Circuitry Tickle/Reset Circuit HY Capacitor Charge and Discharge. Synchronized Cardioversion..... Paddles Status. : ‘System Diagnotics. Display Control and Power Supply... Marker Pulse Circuit Display Board. High Voltage Gharger Board. Power Conditioning Circuit Safety Circuit : Pulse Width Modulator. Charge Disable Circuit. RAMP Generator Circuit CHRGE Rate Threshold Generator Circuit. Low Battery Sense Circuit High Current Switch Circuit Primary Current Sense Circuit Transformer Rectifier Circuit Capacitor Current Sense Circuit Capacitor Voltage Metering Circuit High Voltage Circuitry... HV Capacitor Charge Circuit HV Capacitor Discharge Circuit Siatic Protection Board TABLE OF CONTENTS SERIES 43130A-1 TABLE OF CONTENTS Page Page Battery Charger And 1-1 Low Voltage Power Supplies... 219 Block Diagram 2419 19 V7 121 125 127 1.29 “247 217 218 218 Power InpulGround/ProtectLine Filter Circuit. 220 AC Rectifier/Fiter Circuit 220 Pulse-Width Modulator Control Circuit. 2e1 Power FET/Transformers Switching Circuit 222 Startup And Primary Circuit Power Supply. .. 222 Secondary Reciiier/Fiter Circuits 223 Low Battery Shutdown Circuit 1223 Regulated Power Supplies. . 224 Patient/Satety Relay Drive Circuit 1.225 ‘SECTION Ill - CHECKS AND ADJUSTMENTS Service Mode erg Read Battery Voltage. a) Level Il Performance Checks .... 3 Test Equipment 34 Energy Accuracy. 34 Self Testing Accuracy. 34 Defibrillator Capacitor Charge Time 34 ‘Synchronizer... 34 Safety and Maintenance Checks .. 36 Power Cord To Chassis Ground Resistance Check 35 Paddle Leakage Current (Source Leakage) To Ground 37 Paddle Leakage Current (Gink Curent) With 115 Volts Applied Adjustment Defibrilator Output Energy Calibration (A7 79) 38 Self Test Energy Accuracy Adjustment (A7 R80). . . 38 ‘Switch Settings. . . . 38 ‘Charge Done Tone Option... . 3-9 SECTION IV - SERVICE Battery Removal . 44 Disassembly, 44 Low Voltage Power Supply/ Battery charger Board (Ad). 44 Circuit Breaker Board (A3) 43 Defibrillator H.V. Board (A5) 44 Patient Relay (K1). 44 HV. Capacitor (C1). 45 Safety Relay...... : 45 TABLE OF CONTENTS SERIES 43130A-1 Control Board (A7) Display Overlay Panel... Display Digit Replacement Display Board Replacement Energy Switch Know Removal... Energy Switch (A11-51) 43100-61901 Energy Switch Circuit Board Assembly (A11) Battery Compartment Latches. Paddle Switch Replacement SECTION V - TROUBLESHOOTING Error Messages Page 45 45 46 46 48 48 48 49 49 52 LIST OF ILLUSTRATIONS Figure Title Page 24 Memory Mapped 1/0. 22 22 AID Convert... 6.000.000.0228 23 ECGISYNC Pulse Input Buffer. .2-4 24 Peak Current Detector. . 24 26 Switch Control Logic. 25 26 Speaker Circuitry 25 27 Tickle/Reset Timing Diagram. . ..2-6 28 Paddles Status......... 28 29 Marker Pulse Circuit 29 240 Display Control Circuit 240 241 Display Segment (Source) Drivers... 2-10 242 Display Digit and Discrete LED (ink) Drivers 240 2413 Power Supply Module. 2-11 214 Power Conditioning Circuit ae 245 Safety Circuit 212 246A,B Pulse Width Modulator 243 247 Charge Disable Circuit 243 218 Ramp Generator Circuit . 214 249 Charge Rate Threshold Generator Circuit 1 2N4 2:20 Low Battery Sense Circuit... 2-14 221 High Current Switch Circuit... .2-15 2:22 Primary Current Sense Circuit a. 245 2:23 Transformer/Rectifier Circuit. . .2-15 224 Capacitor Current Sense Circuit 2-16 ‘System Dead Defiritator Problems. Display Problems. ECG Sync or Marker Problems. Service Mode Problems. Battery/Battery Charger Problems. SECTION VI - REPLACEABLE PARTS: Introduction Reference Designators. Ordering Information SECTION Vil - OPTIONS..........-2.00+ Figure Title 225 Capacitor Voltage Metering Circuit nee ee eee . 226 Capacitor Discharge Circuit 227 Static Protection Board, 228 Battery Charger Biock Diagram 229 Power InpuGroundiProtect! Line Filter Circuit. 230 AC RectiierFiter Circuit... 231 Pulse-Width Modulator Control Circuit 232 Power FET/Transformer ‘Switching Circuit. 233 Startup Circuit and Primary Circuit Power Supply 234 Secondary Reciiier/Filter Circuits . . 235 Low Battery Shutdown Circuit 236 Regulated Power Supplies. . 237 Patient/Safety Relay Drive Circuits 34 Sync Cable Assembly 32 Energy Accuracy Test Setup 33 Power Cord to Chassis Ground Resistance Check 34 Paddle Leakage Current to Ground . 35A,B Paddle Leakage Current (ink Current) with 115 Volts Applied. Page 53 1513 514 515 B17 64 61 62 TA Page 247 218 2.18 249 2.20 2:20 221 2.22 2.22 2:23 2.24 2.24 2:25 34 34 35 36 37

Вам также может понравиться