Aribex, Inc. 11727 Fruehauf Drive Charlotte, NC 28273
866.340.5522 (toll free)
800.659.4299 (fax)
Handheld X-ray System
PRO 2 TECH SPECS
Battery Lithium Polymer, 22.2V, 1.25 Ahr
Anode voltage 60kV true DC
Anode current 2.5 mA
TM Exposure time range 0.02 – 1.00 s
Focal spot 0.4 mm
Inherent filtration > 1.5mm Al equivalent
Source to skin distance 20 cm
X-ray field 60 mm round
Maximum duty cycle 1:60
Total weight 5.5 lbs. (2.5 kg)
Approximate W 6.25” L 10.75” H 10”
dimensions (W 16 cm L 27 cm H 25 cm)
Aribex, NOMAD, and NOMAD Pro 2 are
trademarks or registered trademarks of Aribex, Inc. Regulatory requirements can vary in every jurisdiction. Please check with your local authorities or Aribex for any necessary radiation authority approvals needed to operate the NOMAD Pro 2 in a particular region. For indications for use, please visit www.aribex.com/ifu
We improved the NOMAD. We made it more durable. We made it even more reliable. Handheld X-ray System We significantly improved battery performance.
For more info “You can use NOMAD
or to schedule a in the hygiene room for
re-call and in the doctor’s demo, contact room for root canals. One
your dental device takes the place of three
or four wall mounted units, making equipment it much more cost effective than the NOMAD PRO 2
specialist today! old system.”
—LARRY EMMOTT, DDS
Intra-oral X-ray has
Comparative Data for Whole Body Exposure (Annual) The NOMAD Pro 2™ Difference evolved, have you? 50mSv Occupational Dose Limit1 SAFE - Multiple third-party studies have proven—NOMAD IS AS SAFE “My assistants praise the NOMAD for AS CONVENTIONAL SYSTEMS. 5mSv Occupational Dose Limit Requiring Dosimetry1 its simplicity and say that it is quicker 3.65mSv Average Natural Background Radiation2 LIGHTWEIGHT - Weighs only 5.5 pounds! to maneuver and easier to aim than a wall-mounted X-ray unit. It has paid 2.19mSv Average Occupational Radiation Exposure for Flight Crews3 RECHARGEABLE - One charge produces hundreds of X-rays. for itself!” 1.00mSv General Public Dose Limit (excluding natural background and medical care)1 ECONOMICAL - One NOMAD Pro 2 does the work of multiple conventional —SAM J. NECHAMKIN, DDS 0.16-0.37mSv Range of Exposure for Dental Personnel Using Conventional X-rays2 X-ray systems. Improves workflow, fast, and convenient. 0.30mSv Average Exposure Using NOMAD with D-Speed Film4 { 0.12mSv Average Exposure Using NOMAD with F-Speed Film or Digital Sensor4 PRACTICAL - Handheld design allows operator to stay with the patient. Aribex™ Products SIMPLE - Easy to use, no bulky arms, backing plates for walls, special cabinets or costly electrical hookups. 1) Standards for Protection Against Radiation, 10 CFR 20 (US Federal Standards), 1994 (see also NCRP Report No. 116). 2) NCRP Report No. 160 (National Council on Radiation Protection and Measurements), p 211-212. 3) “Estimated Cosmic Radiation Doses for Flight Personnel,” Feng YJ et al, Space Medicine and Medical Engineering, 15(4) 2002, p 265-269. VERSATILE - In or out of the office, NOMAD Pro 2 goes anywhere. 4) Normalized average assumes 7,200 exposures per year, and the average length of exposure for D-speed=0.50 seconds, F-speed=0.25 seconds, digital sensor=0.20 seconds Made in the USA Perfect for use with children, sedated, and special needs patients. TM
Aribex, Inc. 11727 Fruehauf Drive Charlotte, NC 28273
866.340.5522 (toll free)
800.659.4299 (fax)
Handheld X-ray System
PRO 2 TECH SPECS
Battery Lithium Polymer, 22.2V, 1.25 Ahr
Anode voltage 60kV true DC
Anode current 2.5 mA
TM Exposure time range 0.02 – 1.00 s
Focal spot 0.4 mm
Inherent filtration > 1.5mm Al equivalent
Source to skin distance 20 cm
X-ray field 60 mm round
Maximum duty cycle 1:60
Total weight 5.5 lbs. (2.5 kg)
Approximate W 6.25” L 10.75” H 10”
dimensions (W 16 cm L 27 cm H 25 cm)
Aribex, NOMAD, and NOMAD Pro 2 are
trademarks or registered trademarks of Aribex, Inc. Regulatory requirements can vary in every jurisdiction. Please check with your local authorities or Aribex for any necessary radiation authority approvals needed to operate the NOMAD Pro 2 in a particular region. For indications for use, please visit www.aribex.com/ifu